• Title/Summary/Keyword: Active Building Skin

Search Result 8, Processing Time 0.02 seconds

A Study on the inflow of Sunlight through the Active Building Skin - Focusing on Works of Herzog & de Meuron - (활성표피를 통한 빛의 유입에 관한 연구 - 헤르조그 & 드 뫼롱의 작품을 중심으로 -)

  • Na, Ha-Na;Park, Boo-Mee
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.4
    • /
    • pp.30-41
    • /
    • 2017
  • Sunlight is perceived by human beings first through the epidermis to space, and is a non - material medium that provides physical awareness of space, diversified expression of spaces, and plenty experience. The purpose of this study is to investigate the characteristics of active building skin based on the inflow of natural light required by humans, looked through among the works of Jacques Herzog & Pierre de Meuron, which show the characteristics of active building skin, TEA(Tenerife Espacio de las Artes, 2008), Messe Basel New Hall (2013) and Elbphilharmonie (2016). First, the interaction between Sunlight and space is divided into spatial characteristics and sensitivities according to their concepts, properties, and characteristics. The characteristics of active skin by light are classified into a physical approach and a constructive approach. Second, (El Croquis 152/153) and analyzed the images, detail drawings, and elevations, and simulated them in 3D to express the relationship between light and active building skin. Third, the changes of light intensity, light color, and distribution of light according to the time of light entering and the skin are determined from 6:00 am to 6:00 pm. Fourth, the images taken from January 30th to February 7th, 2017 on the site were compared with the computer simulated images, and the relationship between active skin and light was compared. This study is to recognize the existence and necessity of light required for human being through the activated epidermis differentiated from the limited or closed epidermis focused on information transmission, I would like to emphasize that I would like to take a step closer to the necessity and possibility of new attempts and developments so that I can feel the various experiential spaces by.

Study on the Evaluation of Regional Building Energy Efficiency Rating According to the Insulation Performance of Double Skin Window in Apartment Houses Expanded Balcony (발코니 확장형 공동주택의 이중외피 창호 열성능에 따른 지역별 건축물에너지 효율등급 평가)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon;Hong, Won-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.32-37
    • /
    • 2010
  • In order to handle the crisis about energy-environment problem, it is necessary to develop the future-oriented and innovative energy technology in architecture area. So the development of new technology for energy saving and alternative energy use has been spurred in this area. Double skin window system, which is an active covering to respond to the exterior change of the environment, is the skill that can reduce the indoor cooling and heating load and the environmental architecture can be realized. This study works out U-value of windows using the window-simulation program with the development and study of the double skin. In addition, the effect of the double skin insulation on the efficiency rating has been analyzed, applying to the certification system of the building energy efficiency rating which has implemented.

A Study of Micro-piles Method combined with the Resisting Fixture interacting the power of frictional resistance in a contrary direction (양방향 저항체를 결합한 마이크로파일공법 연구)

  • Baik, Dong-Ho;Lee, Sang-Moo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.74-75
    • /
    • 2014
  • In remodeling business or construction of both new strucures and existing structures, Case that pile foundation was set is often. Micro pile, holding compressive force and tensile force by spherical friction, is supported by skin friction rather than end bearing capacity. but, This is weak in tension. Active area of micro pile's skin friction is narrow and micro pile don't do unification behavior hence. So bearing capacity was not fully mobilized in existing researching. In this study, in order to compensate for this method, micro pile to install Resisting Fixture is proposed.

  • PDF

A study on the PAL according to thermal characteristic of building skin and perimeter zone depth (건물 외피의 열특성과 외주부 깊이에 따른 PAL에 관한 연구)

  • Kim, Ji-Hye;Kim, Hwan-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.2
    • /
    • pp.33-38
    • /
    • 2010
  • The perimeter zone is space which receives a significant effect of ambient condition, it is necessary to improve the thermal performance in order to building energy saving. For this reason, a lot of study about the active approach is being performed, such as perimeter-less air conditioning system. But the performance of the perimeter zone is necessary to improve, through the passive approach. Therefore, the purpose of this study is to provide basic materials of energy-saving design of perimeter zone, based of the PAL that simulation changing the thickness of insulation and the rate of windows.

The Indoor Environmental Quality Improving and Energy Saving Potential of Phase-Change Material Integrated Facades for High-Rise Office Buildings in Shanghai

  • Jin, Qian
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.2
    • /
    • pp.197-205
    • /
    • 2017
  • The conflict between indoor environmental quality and energy consumption has become an unneglectable problem for highrise office buildings, where occupants' productivity is highly affected by their working environment. An effective Façade, therefore, should play the role of an active building skin by adapting to the ever-changing external environment and internal requirements. This paper explores the energy-saving and indoor environment-improving potential of a phase-change material (PCM) integrated Façade. Building performance simulations, combined with parametric study and sensitivity analysis, are adopted in this research. The result quantifies the potential of a PCM-integrated Façade with different configurations and PCM properties, taking as an example a south-oriented typical office room in Shanghai. It is found that a melting temperature of around $22^{\circ}C$ for the PCM layer is optimal. Compared to a conventional Façade, a PCM-integrated Façade effectively reduces total energy use, peak heating/cooling load, and operative temperature fluctuation during the periods of May-July and November-December.

A Study on the Sustainable Characteristics of the London City Hall (런던 시청사의 지속가능적 특성에 관한 연구)

  • Chung, Tae-Yong
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.5
    • /
    • pp.3-12
    • /
    • 2011
  • The purpose of this study is to analyze the sustainable characteristics of London city hall designed by Norman Foster. The most important part of sustainable architecture might be the energy reduction including minimizing CO$_2$ emission but social and economical aspects of sustainability should not be neglected. London City Hall as a successful example of sustainable architecture depends its success on the harmony of social, environmental and economical aspects of sustainability. Social sustainability in London City Hall appears on appropriateness and public good in the facility. London City Hall act as a symbol of redevelopment and civic community. Environmental sustainability of London City Hall summarized as using unique building form, double skin and underground water cooling system for the purpose of energy saving. Computer modeling technology was introduced to save construction cost for economic aspect of sustainability. Rational configuration of mechanical system strengthen the durability of facility. In case of London City Hall, the function of building, site condition and architectural concept fulfill the every aspects of sustainability in architecture. Besides these conditions, Foster applied sustainability to London City Hall as active and concrete design concept to complete its design goals.

Design & Performance of the Solar Energy Research & Test Center (태양에너지 연구 시험센타 설계 및 효율에 관한 연구)

  • Auh, Paul Chung-Moo;Lee, Jong-Ho;Choi, Byung-Owan;Cho, Yil-Sik
    • Solar Energy
    • /
    • v.2 no.2
    • /
    • pp.29-36
    • /
    • 1982
  • The Solar Energy R&D Department of KIER under the auspice of the Korean government is pushing hard on the development of the passive solar technology with high priority for the expeditious widespread use of solar energy in Korea, since the past few years of experiences told us that the active solar technology is not yet ready for massive commercialization in Korea. KIER has completed the construction of the Solar Energy Research & Test Center in Seoul, which houses the major facilities for its all solar test programs. The Center was designed as a passive solar building with great emphasis on the energy conserving ideas. The Center is not only the largest passive building in Korea, but also the exhibit center for the effective demonstration of the passive heating and cooling technology to the Korean public. The Center was designed to satisfy the requirements based on the technical and economical criteria set by the KIER. Careful considerations, therefore, were given in depth in the following areas to meet the requirements. 1) Passive Heating Concepts The Center employed the combination of direct and indirect gain system. The shape of the Center is Balcomb House style, and it included a large built-in sunspace in front. A partition, consists of transparent and translucent glazings, separates the sunspace and the living space. Since most activities in the Center occur during the day time, direct utilization of the solar energy by the living spaces was emphasized with the limited energy storage capacity. 2) Passive Cooling Concepts(for Summer) Natural ventilation concept was utilized throughout the building. In the direct gain portion of the system, the front glazing can be openable during the cooling season. Natural convection scheme was also applied to the front sunspace for the Summer cooling. Reflective surfaces and curtains were utilized wherever needed. 3) Auxiliary Heat ing and Cooling System As an auxiliary cooling system, mechanical means(forced convection system) were adopted. Therefore forced air heating system was also used to match the duct work requirements of the auxiliary cool ing system. 4) Effect ive Insulation & Others These included the double glazed windows, the double entry doors, the night glazing insulation, the front glazing-frame insulation as well as the building skin insulation. All locally available construction materials were used, and natural lightings were provided as much as possible. The expected annual energy savings (compared to the non-insulated conventional building)of the Center was estimated to be about 80%, which accounts for both the energy conservation and the solar energy source. The Center is being instumented for the actual performance tests. The experimental results of the simplified tests are discussed in this paper.

  • PDF

Use of δ-Aminolevulinic Acid in Swine Diet: Effect on Growth Performance, Behavioral Characteristics and Hematological/Immune Status in Nursery Pigs

  • Mateo, R.D.;Morrow, J.L.;Dailey, J.W.;Ji, F.;Kim, Sung Woo
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.1
    • /
    • pp.97-101
    • /
    • 2006
  • Certain amino acids are essential precursors of a variety of important biomolecules in addition to their major function as protein building blocks. ${\delta}$-Aminolevulinic acid (ALA) is synthesized from the condensed form of succinyl-CoA with glycine after decarboxylation catalyzed by ALA synthase. The objective of the study was to determine the effects of ALA supplementation on growth performance, behavioral characteristics and hematological/immune status in nursery pigs. A total of 144 pigs weaned at 21 d of age were allotted to three dietary treatments representing (-) control (w/o antibiotics; NC), (+) control (w/carbadox at 50 mg/kg; PC), and the treatment group with ALA supplementation (0.05%; TA). Each treatment had 6 pens (replicates) with 8 pigs per pen. Pigs were fed phase 1 (21.9% CP, 1.40% Lys) and 2 (20.6% CP, 1.15% Lys) experimental diets for 3 and 2 wks, respectively. Feed intake and weight gain were measured weekly during phase 1 and at the end of phase 2. At the end of phase 2, blood samples were taken and analyzed using an automated hematology analyzer. Skin color and activity of pigs (48 h) from all pens in each treatment were measured at the second week of phase 2. Growth performance was not affected (p>0.05) by the dietary supplementation of ALA during the 5 wk nursery period. Pigs in the TA (6.46) and PC (6.68) had a higher (p<0.05) number of red blood cells ($10^6cell/{\mu}L$) than pigs in the NC (6.15). Pigs in PC (12.16) had a higher (p<0.05) hemoglobin level (g/dL) than pigs in the NC group (11.29) and the TA group (11.47). Pigs in the TA and PC had darker (p<0.05) and less (p<0.05) yellow skin color than pigs in the NC. Pigs in the PC tended (p = 0.081) to be less active than pigs in the other groups. There were no differences in behavioral characteristics between the NC and the TA. The data suggest that ALA supplementation has no adverse effects on growth performance of nursery pigs. Moreover, ALA supplementation increased red blood cell counts which may be beneficial to pigs.