• Title/Summary/Keyword: Active & reactive power

Search Result 460, Processing Time 0.022 seconds

Control Strategy and Characteristic Analysis of Hybrid Active Power Filters with the Resonant Impedance Principle

  • Fang, Lu;Xu, Xian-Yong;Luo, An;Li, Yan;Tu, Chun-Ming;Fang, Hou-Hui
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.935-946
    • /
    • 2012
  • A new kind of resonant impedance type hybrid active filter (RITHAF) is proposed for dynamic harmonic current suppression and high capacity reactive compensation in medium and high voltage systems. This paper analyzed the different performance of the RITHAF when the active part of the RITHAF is controlled as a current source and as a voltage source, respectively. The harmonic suppression function is defined in this paper. The influences of the changes caused by the grid impedance and the detuning of the passive power filter on the compensating characteristics of the RITHAF are studied by analyzing the suppression function. Simulation and industrial application results show that the RITHAF has excellent performances in harmonic suppression and reactive compensation, which is suitable for medium and high voltage systems.

HVDC System Design for AC Network Reactive Power Control (AC 계통 무효전력 제어를 위한 HVDC 시스템 설계)

  • Choi, Soon-Ho;Choi, Jang-Hum;Kim, Chan-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.8-20
    • /
    • 2013
  • This paper deals with the concept design of HVDC system for controlling AC network reactive power. HVDC system can control active power and reactive power and the control concept of reactive power is similar to SVC(Static Var Compensator). Reactive power is controlled by adjusting firing angle of HVDC system under the condition that AC filters are switched. Reactive power depends on AC voltage condition, considering the steady-state and transient state to maintain the stable operation of AC network in the viewpoint of voltage stability. Therefore, in the design stage of HVDC, the reactive power required in the AC network must be considered. For the calculation of operation angle in HVDC system, the expected reactive power demand and supply status is examined at each AC system bus. The required reactive power affects the determination of the operation angle of HVDC. That is, the range of "control deadband" of operation angle should have the capability supplying the required reactive power. Finally, the reactive power control concepts is applied to 1GW BTB Pyeongtaek-Dangjin HVDC system.

Coordination of UPFC and Reactive Power Sources for Steady-state Voltage Control (정상상태 전압제어를 위한 UPFC와 조상설비의 협조)

  • Park, Ji-Ho;Lee, Sang-Duk;Jyung, Tae-Young;Jeong, Ki-Seok;Baek, Young-Sik;Seo, Gyu-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.921-928
    • /
    • 2011
  • This paper presents a new method of local voltage control to achieve coordinative control among UPFC(Unified Power Flow Controller) and conventional reactive compensation equipments, such as switched-shunt and ULTC(Under-Load Tap Changing) transformer. Reactive power control has various difficult aspects to control because of difficulty of system analysis. Recently, the progress of power electronics technologies has lead to commercial availability of several FACTS(Flexible AC Transmission System) devices. The UPFC(Unified Power Flow Controller) simultaneously allows the independent control of active and reactive power flows as well as control of the voltage profile. When conventional reactive power sources and UPFC are used to control system voltage, the UPFC reacts to the voltage deviation faster than the conventional reactive power sources. Keeping reactive power reserve in an UPFC during steady-state operation is always needed to provide reactive power requirements during emergencies. Therefore, coordination control among UPFC and conventional reactive power sources is needed. This paper describe the method to keep or control the voltage of power system of local area and to manege reactive power reserve using PSS/E with Python. The result of simulation shows that the proposed method can control the local bus voltage within the given voltage limit and manege reactive power reserve.

Current-Fed Reactive Power Compensator Using Delta Modulation Technique (델터 변조 방식을 이용한 전류형 무효전력 보상장치)

  • 백형래;김한성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.3
    • /
    • pp.244-252
    • /
    • 1992
  • This paper describes a reactive power compensator using current-source delta modulation converter, which compensates the reactive power in the ac sides of 3-phase rectifier. In the conventional current control methods for the current-type reactive power compensators, it is usual to compare the reactive reference current signal with the triangular wave and hence to generate the ON-OFF signals for the reactive power compensator. To improve the response as well as the control capability, the delta modulated current control technique is used in this paper. As a result, the input power factor is improved close to unity and both simulation and experimental results show good compensating performances.

  • PDF

The Harmonics and Reactive Power Compensation with Series Active Power filter in 3-phase 4-wire System (3상 4선식 전력시스템에서 직렬형 능동필터에 의한 고조파전류와 무효전력 보상에 관한 연구)

  • Kim, Jin-Sun;Kim, Young-Jo;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1072-1074
    • /
    • 2003
  • In this paper, a new control strategy of a series active power filter using direct compensating voltage extraction method is proposed. This control algorithm compensates harmonics, reactive power and neutral line currents which are generated by balanced or unbalanced nonlinear loads. The advantage of this method is that the compensating voltage of the series active power filter can be extracted without phase transformation. Therefore, calculation time is shorten and the control method is simple compared with conventional method as the p-q theory In addition, this control strategy was applied for the series active power filter in 3-phase 4-wire system which is widely employed in distributing electric energy to several office building and manufacturing plants. Some results obtained from the experimental model using the proposed method are presented to demonstrate and confirm its validity.

  • PDF

A Study on the Single Phase Voltage-Controlled Active Power Filter for Power Quality Improvement (전력품질 개선을 위한 단상 전압제어형 능동전력필터 시스템에 관한 연구)

  • 손진근
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.238-245
    • /
    • 2003
  • In this paper, a single Phase voltage source voltage-controlled active power filter(APF) for power quality improvement was proposed. The proposed APF has the performance of harmonic suppression and unity power factor correction. The performance of harmonic suppression can be obtained by controlling the waveshape of the APF output voltage to be sine wave. And, unity power factor is controlled by the reactive power control loop of the APF output. Simulation and experimental results using diode rectifier showed that the voltage-controlled APF, unlike the current-controlled APF, can reduce the voltage harmonics as well as current harmonics. Also the results showed that the input dover factor and power quality were greatly improved.

Transient Stability Enhancement of Power System by Using Energy Storage System (풍력터빈 발전기가 연계된 전력계통에서 에너지저장시스템이 과도안정도에 미치는 영향)

  • Seo, Gyu-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.592-597
    • /
    • 2019
  • A conventional method to improve transient stability in power system is the use of reactive power compensation devices such as STATCOM and SVC. However, this traditional method cannot prevent a rapid voltage collapse brought on by motors stalling due to system fault. On the other hand, ESS(Energy Storage System) provides fast-acting, flexible reactive and active power control. The fast active power compensation with energy storage system plays a significant role in transient stability enhancement after a major fault of power system. In this paper, transient stability enhancement method by using energy storage system is proposed for the power system including a dynamic load such as large motor. The effectiveness of energy storage system compared to conventional devices in enhancing transient stability of power system is presented. The results of simulations show that the simultaneous injection of active and reactive power can enhance more effectively transient stability.

Active and Reactive Power Control of ESS in Distribution System for Improvement of Power Smoothing Control

  • Shin, Seong-Su;Oh, Joon-Seok;Jang, Su-Hyeong;Cha, Jae-Hun;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1007-1015
    • /
    • 2017
  • This paper proposes a new control technique of energy storage system (ESS) for smoothing the active power of renewable energy sources (RES) such as photovoltaic and wind turbine generation. As the penetration of RES into grid increases, it is difficult to maintain the permissible level of power quality, that is, voltage and frequency fluctuation in power systems. To solve this problem, ESS control methods using low pass filter (LPF) have been proposed for mitigating the fluctuation of RES output. However, those have a lot of drawbacks which need to be supplemented. Hence, this paper presents the improved active power control with additional reactive power control for maintaining power quality properly. The proposed method minimizes the capacity of ESS to be required for smoothing RES output fluctuation through mitigation of phase delay problem in LPF. In addition, the voltage regulation improves by using additional reactive power control. The proposed method was verified through simulation analysis using PSCAD/EMTDC.

Instantaneous Reactive Power Compensation Theory Increasing The Control Freedom One Degree Higher (제어 자유도를 한 차원 증가시킨 순시무효전력 보상이론)

  • Kim, Hyo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2481-2483
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

Eliminating the Neutral Current by the Instantaneous Reactive Power Compensation (순시무효전력 보상에 의한 중성선 전류의 제거)

  • Kim, Hyo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.131-133
    • /
    • 1998
  • This paper, proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of the three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF