• Title/Summary/Keyword: Activation loss

Search Result 528, Processing Time 0.023 seconds

Measurement of Activation and Ohmic Losses using a Current Interruption Technique in a Microbial Fuel Cell (미생물연료전지(MFC)에서 전류차단법(current interrupt technique)을 이용한 활성화전압손실(activation loss)과 저항전압손실(Ohmic loss)의 측정)

  • Park, Kyung-Won;Oh, Sang-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.357-362
    • /
    • 2010
  • Electricity can be directly generated from organic matter even wastewaters using a microbial fuel cell. To achieve high power in MFCs, finding factors decreasing activation and Ohmic losses is very important. In this study we determined activation loss at the anode and cathode and Ohmic loss using the current interruption technique in a H-type MFC. Activation loss at the cathode was four times higher that that of anode activation loss even if pt-coated carbon (0.5 $mg/cm^2$;10%Pt) was used as the cathode. Ohmic loss determined using current interruption technique (1146 ${\Omega}$) was almost same as the internal resistance (1167 ${\Omega}$) measured using AC impedance. The sum of activation losses at the anode and cathode was the same as the value of activation loss of the cell.

Comparison of Electromyography Muscle in Lower Extremity from Isometric Trunk Exercise for 12weeks of Elderly Hansen's disease in Facility-Dwelled and Foot Sensory Loss (12주간 정적체간운동을 통한 시설거주 발감각 소실 한센노인의 하지 근전도 비교)

  • Jun, Soon-Mi
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.1
    • /
    • pp.93-101
    • /
    • 2011
  • Purpose : The purpose of this study was to investigate the effects of maximum muscle activation of lower extremity of facility dwelled elderly Hansen's disease after isometric trunk exercise for 12weeks. Methods:18 elderly Hansen's disease who isometric trunk exercise for 12weeks were recruited for this study. They were instructed to perform maximum muscle activation of lower extremity after exercise. and the subjects were divided into normal sensory group, sensory loss in left foot group, sensory loss in right foot group and sensory loss in both feet group, according to the sensory condition ability on their soles. Results : After exercise, Hamstring muscle increased significantly (p<.05), and activation of the rectus femoris muscle decreased with a significance (p<05). In terms of Post-hoc test for examining the difference in MVIC according to sensory condition, there was significant difference in the normal sensory group, sensory loss in right and left foot group of left hamstring muscle before the exercise(p=.01) and the normal sensory group, sensory loss in both feet group of right hamstring muscle before the exercise(p=.04). Conclusion : These results indicate that the maximum muscle activation was changed after isometric trunk exercise. it could be improved maximum muscle activation of lower extremity muscle after the exercise although there was sensory loss.

Performance Improvement Method of Deep Neural Network Using Parametric Activation Functions (파라메트릭 활성함수를 이용한 심층신경망의 성능향상 방법)

  • Kong, Nayoung;Ko, Sunwoo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.3
    • /
    • pp.616-625
    • /
    • 2021
  • Deep neural networks are an approximation method that approximates an arbitrary function to a linear model and then repeats additional approximation using a nonlinear active function. In this process, the method of evaluating the performance of approximation uses the loss function. Existing in-depth learning methods implement approximation that takes into account loss functions in the linear approximation process, but non-linear approximation phases that use active functions use non-linear transformation that is not related to reduction of loss functions of loss. This study proposes parametric activation functions that introduce scale parameters that can change the scale of activation functions and location parameters that can change the location of activation functions. By introducing parametric activation functions based on scale and location parameters, the performance of nonlinear approximation using activation functions can be improved. The scale and location parameters in each hidden layer can improve the performance of the deep neural network by determining parameters that minimize the loss function value through the learning process using the primary differential coefficient of the loss function for the parameters in the backpropagation. Through MNIST classification problems and XOR problems, parametric activation functions have been found to have superior performance over existing activation functions.

Radiation Effects on ${\gamma}$-Ray Irradiated Ethylene Propylene Rubber using Dielectric Analysis

  • Kim, Ki-Yup;Ryu, Boo-Hyung;Lee, Chung;Lim, Kee-Joe
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.2
    • /
    • pp.48-54
    • /
    • 2003
  • To evaluate the radiation degradation of ethylene propylene rubber (EPR), radiation effects on EPR were investigated by using dielectric analysis and thermal-gravimetric analysis. Permittivity, loss factor, tan$\delta$, and thermal decomposition temperature were observed for ${\gamma}$-ray irradiated EPR. As the radiation dose was increased, the peak temperature of the loss factor and tans of EPR were increased and loss factor and tan$\delta$ at peak temperature were decreased. Activation energies were calculated using loss factor and thermal decomposition for ${\gamma}$-ray irradiated EPR as well. The trends of both calculated activation energies showed the same tendencies as radiation dose was increased.

Performance Analysis of Polymer Electrolyte Membrane Fuel Cell by AC Impedance Measurement (교류 임피던스 측정법을 이용한 고분자 전해질 연료전지의 성능특성 분석)

  • Seo, Sang-Hern;Lee, Chang-Sik
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.4
    • /
    • pp.283-290
    • /
    • 2009
  • This study focuses on the performance characteristics of polymer electrolyte membrane fuel cell (PEMFC) using the AC impedance technique. The experiment was carried out to investigate the optimal operating conditions of PEMFC such as cell temperature, flow rate, humidified temperature and back-pressure. The fuel cell performance was analyzed by DC electronic-loader with constant voltage mode and expressed by voltage-current density. Additionally, AC impedance was measured to analysis of ohmic and activation loss and expressed by Nyquist plot. The results showed that the cell performance increased with increase of cell temperature, air flow rate, humidified temperature and backpressure. Also, the activation loss decreased as the increase of cell temperature, air flow rate, humidified temperature and backpressure.

Steam Activation Behaviors of Oxidatively Stabilized Petroleum-based Pitch Fibers Spun by Melt-blown Method

  • Kim, Chan;Kim, Young-Min;Yang, Kap-Seung
    • Carbon letters
    • /
    • v.3 no.2
    • /
    • pp.93-98
    • /
    • 2002
  • Short pitch fibers were prepared from petroleum based isotropic precursor pitch by melt-blown technology. The pitch fibers were stabilized in oxidizing condition, followed by steam activations at various conditions. The fiber surface and pore structures of the activated carbon fibers (ACFs) were respectively characterized by using SEM and applying BET theory from nitrogen adsorption at 77 K. The weight loss of the oxidized fiber was proportional to activation temperature and activation time, independently. The adsorption isotherms of the nitrogen on the ACFs were constructed and analyzed to be as Type I consisting of micropores mainly. The specific surface area of the ACFs proportionally increased with the weight loss at a given activation temperature. The specific surface area was ranged 850~1900 $m^2/g$ with pores of narrow distribution in sizes. The average pore size was ranged 5.8~14.1 ${\AA}$ with the larger value from the more severe activation condition.

  • PDF

Study on the Activation Energy of Charge Migration for 3D NAND Flash Memory Application (3차원 플래시 메모리의 전하 손실 원인 규명을 위한 Activation Energy 분석)

  • Yang, Hee Hun;Sung, Jae Young;Lee, Hwee Yeon;Jeong, Jun Kyo;Lee, Ga won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.2
    • /
    • pp.82-86
    • /
    • 2019
  • The reliability of 3D NAND flash memory cell is affected by the charge migration which can be divided into the vertical migration and the lateral migration. To clarify the difference of two migrations, the activation energy of the charge loss is extracted and compared in a conventional square device pattern and a new test pattern where the perimeter of the gate is exaggerated but the area is same. The charge loss is larger in the suggested test pattern and the activation energy is extracted to be 0.058 eV while the activation energy is 0.28 eV in the square pattern.

Numerical Analysis on Performance Changes of the Tubular SOFCs according to Current Collecting Method (전류집전 방법에 따른 원통형 고체산화물 연료전지의 성능 변화 수치해석)

  • Yu, Geon;Park, Seok-Joo;Lee, Jong-Won;Lee, Seung-Bok;Lim, Tak-Hyoung;Song, Rak-Hyun;Shin, Dong-Ryul;Kim, Ho-Young
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.2
    • /
    • pp.129-138
    • /
    • 2011
  • Performance changes of an anode-supported tubular SOFC including current collectors are analyzed at different current collecting methods using numerical simulation. From the two dimensional numerical model of the solid oxide fuel cell with nickel felts as anodic current collectors and silver wires as cathodic ones, the performance curves and the distributions of temperature, concentration, current density are obtained. Also, the voltage loss of the cell is divided into three parts: activation loss, concentration loss and ohmic loss. The results show that the performance change of the cell is dominantly influenced by the ohmic loss. Although the temperature and concentration distributions are different, the total activation loss and concentration loss are nearly same. And the ohmic loss is divided into each parts of the cell components. The ohmic loss of the anodic current collectorreaches about 60~80% of the cell's total ohmic loss. Therefore, the reduction of the ohmic loss of the anodic current collector is very important for stack power enhancement. It is also recommended that the load should be connected to the both ends of the anodic current collector.

Study on the cathode delamination of solid oxide fuel cell (고체산화물 연료전지의 공기극 박리 현상에 관한 연구)

  • Park, Kwang-Jin;Bae, Joong-Myeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.139-142
    • /
    • 2009
  • In this study, the performance degradation of SOFC single cell caused by the delamination between a cathode and an electrolyte is investigated. As the delamination rate increases, the voltage sharply decreases due to the decrease of reaction sites and losses increase. The current is concentrated to the intact area so that the current density is increased and the ohmic loss and the activation loss become higher. Most part of loss is due to the ohmc loss of electrolyte.

  • PDF

Study of Voltage Loss on Polymer Electrolyte Membrane Fuel Cell Using Empirical Equation (Empirical Equation을 이용한 고분자전해질 연료전지의 전압 손실에 대한 연구)

  • Kim, Kiseok;Goo, Youngmo;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.789-798
    • /
    • 2018
  • The role of empirical equation to predict the performance of polymer electrolyte membrane fuel cell is important. The activation, ohmic and mass transfer losses were separated in a polarization curve, and the curve fitting according to each region was performed using Kim's model and Hao's model. Changes of each loss were compared according to operation variables of the temperature, pressure, oxygen concentration and membrane thickness. The existing model showed a good fitting convergence, but less fitting accuracy in the separated loss region. A new model using the convergence coefficient was suggested to improve the accuracy of performance prediction of fuel cells of which results were demonstrated.