• Title/Summary/Keyword: Acrylic Fiber

Search Result 127, Processing Time 0.064 seconds

Gold Recovery Using Inherently Conducting Polymer Coated Textiles

  • Tsekouras, George;Ralph, Stephen F.;Price, William E.;Wallace, Gordon G.
    • Fibers and Polymers
    • /
    • v.5 no.1
    • /
    • pp.1-5
    • /
    • 2004
  • The ability of inherently conducting polymer (ICP) coated textiles to recover gold metal from aqueous solutions containing $[AuCl_4]^-$ was investigated. Nylon-lycra, nylon, acrylic, polyester and cotton were coated with a layer of polypyrrole (PPy) doped with 1,5-naphthalenedisulfonic acid (NDSA), 2-anthraquinonesulfonic acid (AQSA) or p-toluenesulfonic acid (pTS). Textiles coated with polyaniline (PAn) doped with chloride were also used. The highest gold capacity was displayed by PPy/NDSA/nylon-lycra, which exhibited a capacity of 115 mgAu/g coated textile, or 9700 mgAu/g polymer. Varying the underlying textile substrate or the ICP coating had a major effect on the gold capacity of the composites. Several ICP coated textiles recovered more than 90 % of the gold initially present in solutions containing 10 ppm $[AuCl_4]^-$ and 0.1 M HCl in less than 1 min. Both PPy/NDSA/nylon-lycra and PAn/Cl/nylon-lycra recovered approximately 60 % of the gold and none of the iron present in a solution containing 1 ppm $[AuCl_4]^-$, 1000 ppm $Fe^{3+}$ and 0.1 M HCl. The spontaneous and sustained recovery of gold metal from aqueous solutions containing $[AuCl_4]^-$ using ICP coated textiles has good prospects as a potential future technology.

Properties of St/BA Modified Cellular Lightweight Concrete as Sandwich Panel Core (샌드위치패널심재로 활용한 St/BA 개질 다공성 경량 콘크리트의 특성)

  • 강내민;노정식;도정윤;문경주;소양섭
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.31-34
    • /
    • 2003
  • Sandwich panel is composed of the facing sheets which support the external load, the cellular core with the low thermal conductivity and the adhesive agent to bond them. The cellular core was produced by binding lightweight cellular aggregates with cement and two types of acrylic base St/BA emulsion were added with a view to improving the workability ion due to high absorption of light weight aggregate and to develope more strength, respectively. This investigation is to comprehend the effect of the addition of two types of St/BA on thermal conductivity, calorific value and exhaustion content of noxious gas in addition re compressive and flexural strength. Flexural strength of the specimen made with St/BA-2 ranged 20kgf/cm2 to 25kgf/cm2 and was about 50% to 100% as high as that of the non-fiber specimen. Thermal conductivity was recorded from 2.0 to 3.0 kcal/mh$^{\circ}C$ and calorific value of St/BA modified specimen was much lower than that of commercial sandwich panel core of EPS and urethane. Careful caution has to be taken because generation of noxious gas such as CO, NO and SO2 tend to increase with addition of polymer cement ratio.

  • PDF

Studies on Electrostatic Propensity of Fabrics (직물대전성에 관한 연구)

  • 최병희;배도규
    • Journal of Sericultural and Entomological Science
    • /
    • v.27 no.2
    • /
    • pp.54-63
    • /
    • 1985
  • This studies has been carried out how to effect on electrostafic propensity of synthetic fabrics by coating with 0.5% acrylic polymer solution which was previously developed by the author to improve anticrease nature of silk. The work conditions are: (A) Applied synthetic polymer was acrylic polymer 525, developed by the author. (B) Electrostatic voltage for various fabrics were carried out by Korea standard abrasion partner with Korea standard (KS K 0905) cotton, nylon, polyester and the self sample fabric. (C) Applied fabrics for the investigations were carried out by using abrasion partner with Korea standard (KS K 0905) cotton, nylon, polyester and the self sample fabric. (D) Electrostatic propensity investigations were carried out by use of sample as silk, nylon, polyester and acrylic fabrics, seperating before finish or after finish. (E) Washing after the finish or the original fabric was carried out by Korea standard method, KS K 0465. Through the investigations, he happened to find many interesting matters and the obtained results are as followings. 1. Electrostatic voltage for the finished fabrics increased more than their original silk, nylon, acrylic fabrics except polyester fabric. (See Table 5) 2. Electrostatic voltage for the finished polyester against K.S. polyester decreased remarkably than the original fabric test. 3. In spite of no problem on electrostatic propensity of silk, it showed high electrostatic voltage between the same nature fabric abrasion, because silk is very weak against abrasion and because the test method had been developed to be useful for only synthetic fabrics. 4. Electrostatic voltage increased more in case of abrasion between different nature of fabrics than the same nature of fabrics. 5. Electrostatic voltage of each fabric increased by repeat of wash. 6. Many investigation data were followed with Contact Electrification Series Principle, another word, the farther each other located fabric on the series abrasion was, the higher electrostatic voltage. (See Fig. 6) 7. Such investigation gives warning of use on the mix fiber spinning service as far as concern with electrification. 8. It may also call attention for such increase of electrification in case any finishing of silk textile.

  • PDF

MACRO-SHEAR BOND STRENGTH AND MICRO-SHEAR BOND STRENGTH OF CEROMER BONDED TO METAL ALLOY AND FIBER REINFORCED COMPOSITE

  • Park Hyung-Yoon;Cho Lee-Ra;Cho Kyung-Mo;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.654-663
    • /
    • 2004
  • Statement of problem. According to the fracture pattern in several reports, fractures most frequently occur in the interface between the ceromer and the substructure. Purpose. The aim of this in vitro study was to compare the macro shear bond strength and microshear bond strength of a ceromer bonded to a fiber reinforced composite (FRC) as well as metal alloys. Material and methods. Ten of the following substructures, type II gold alloy, Co-Cr alloy, Ni-Cr alloy, and FRC (Vectris) substructures with a 12 mm in diameter, were imbedded in acrylic resin and ground with 400, and 1, 000-grit sandpaper. The metal primer and wetting agent were applied to the sandblasted bonding area of the metal specimens and the FRC specimens, respectively. The ceromer was placed onto a 6 mm diameter and 3 mm height mold in the macro-shear test and 1 mm diameter and 2 mm height mold in the micro-shear test, and then polymerized. The macro- and micro-shear bond strength were measured using a universal testing machine and a micro-shear tester, respectively. The macro- and micro-shear strength were analyzed with ANOVA and a post-hoc Scheffe adjustment ($\alpha$ = .05). The fracture surfaces of the crowns were then examined by scanning electron microscopy to determine the mode of failure. Chi-square test was used to identify the differences in the failure mode. Results. The macro-shear strength and the micro-shear strength differed significantly with the types of substructure (P<.001). Although the ceromer/FRC group showed the highest macroand micro-shear strength, the micro-shear strength was not significantly different from that of the base metal alloy groups. The base metal alloy substructure groups showed the lowest mean macro-shear strength. However, the gold alloy substructure group exhibited the least micro-shear strength. The micro-shear strength was higher than the macro-shear strength excluding the gold alloy substructure group. Adhesive failure was most frequent type of fracture in the ceromer specimens bonded to the gold alloys. Cohesive failure at the ceromer layer was more common in the base metals and FRC substructures. Conclusion. The Vectris substructure had higher shear strength than the other substructures. Although the shear strength of the ceromer bonded to the base metals was lower than that of the gold alloy, the micro-shear strength of the base metals were superior to that of the gold alloy.

IMMOBILIZATION OF LOWER MANDIBULAR ALVEOLAR BONE FRACTURE USING RESIN-WIRE OPEN CAP SPLINT (하악 유전치부 치조골 골절시 resin-wire open cap splint를 이용한 고정)

  • Kwon, Joung-Hyun;Choi, Byung-Jai;Choi, Hyung-Jun;Kim, Seong-Oh;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.175-180
    • /
    • 2008
  • Traumatic injuries to the primary dentition are commonly encountered problems in dental practice. It is found that 30% of the children had injuries to the primary dentition and 22% to the permanent dentition. The greatest incidence of trauma to the primary dentition occurs at the ages of 2 and 3 as children start to learn motor coordination. Because teeth and alveolar bone are traumatized simultaneously, alveolar bone fractures are likely to occur when multiple teeth are involved in injuries. Dental splints are indicated for the management of maxillofacial fractures. They enable anatomic reduction of fractured segments and help immobilization and maintenance of the fragments after reduction. They also act as a stabilizer during rehabilitation. Various types of dental splints are available. In this case, routine resin-wire splint technique could not be applied because of the child's uncooperative behavior. Oral sedation was not indicated because N.P.O. had not been preceded. Therefore, we decided to use open-cap acrylic splint instead. Stabilization using open cap acrylic splint requires minimum chair time with reduced discomfort to both patient and dentist. It is an effective means of splint for uncooperative children and especially useful when other means of fixation have been failed. Because trauma on the primary dentition can affect the underlying permanent tooth germ, it is important to monitor eruption process of the permanent dentition.

  • PDF

Printing Technology of Nano fiber under 900nm (900nm 이하급 나노섬유의 현장적용 날염기술)

  • Yong, Kwang-Joong;Lee, Beom-Soo;Lee, Hee-Jun;Hwang, Tea-Yeon
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.83-83
    • /
    • 2011
  • 나노섬유는 마이크로 섬유에 비해 $10^3$배 정도의 넓은 표면적을 가지며, 다른 섬유와 비교하여 유연성, 투습성과 같은 특성이 우수하다. 나노섬유의 제조방법은 여러 가지가 있으나, 상용화의 가능성, 적용 고분자의 다양성, 제조공정의 단순성, 다양한 제품기술에의 응용성 등을 고려하여 선택하여야 한다. 나노섬유의 제조기술은 방법에 따라 전기방사, 복합방사, 멜트블로운 공정, 에어레이드 공정, 습식 공정 등으로 나눌 수 있다. 전기방사 등 나노섬유를 대량생산하여 상용화하려는 노력을 지속적으로 하고 있으나 나노섬유의 염색가공에 관련되어 기술적 한계로 제품전개에 많은 어려움을 겪고 있다. 그리하여 본 연구에서는 나노섬유 단독으로 제품화하기에는 강도 등의 문제로 PET에 워터펀칭한 복합소재로 개발하여 900nm 이하의 나노섬유에 대한 최적의 날염조건과 현장적용 생산기술을 개발하고자 하였다. 나노섬유 복합소재에 대하여 Brown, Red, Blue, Black 색상의 안료와 Urethane, Rubber, Acrylic, Eco Binder를 사용하여 날염 실험하였으며, 최적의 조건으로 현장생산에 적용하여 생산하였다. 안료의 고착성을 높여 날염성과 염색견뢰도를 증진시키기 위하여 원적외선 열처리기를 개발하여 현장생산에 접목시켰다. 원적외선 열처리기는 벙커C유 또는 가스 등을 사용하는 텐터나 증열기와는 다르게 전기를 에너지원으로 하여 원적외선 램프를 이용한 건열시스템의 형태로 저공해 및 그린 형태의 열처리기 시스템으로, 섬유에 대한 원적외선의 조사거리, 원적외선 램프의 간격, 적용 온도, 원단이송 속도 등에 따른 최적의 원적외선 열처리기 날염조건을 설정하였다. 바인더에 따른 날염성은 우레탄계 바인더를 사용하였을 경우에 가장 선명하고 깊은 색상을 보였으며, 아크릴계 바인더의 경우가 가장 낮은 색상을 보였으며 염색견뢰도는 대체적으로 양호한 결과를 얻었다. 그리고, 최근 환경적인 추세에 맞추어 에코 바인더를 사용하여 날염한 결과 염색성과 내구성 등은 우레탄계와 아크릴계 바인더의 중간 정도의 결과를 보였다.

  • PDF

A Study on the Preparation of Durable Softening Water Repellents by Blends of Fatty Carbamide/Wax/Acrylic Copolymer(III);Water Repelling Treatment of Nylon Fabrics (지방산 카르바미드/왁스/아크릴 공중합체의 블렌드에 의한 내구유연발수제의 제조에 관한 연구(III);나일론 직물에의 발수처리)

  • Kim, Seung-Jin;Im, Wan-Bin;Ahn, Chong-Il;Park, Hong-Soo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.69-74
    • /
    • 1994
  • Durable softening water repellents for nylon fiber were synthesized, using two compounds: quaternized octadecyl methacrylate-2-diethylaminoethyl methacrylate copolymer as a mother resin of water repellent and quaternized fatty carbamide for improving softness and hydrostatic pressure, of which syntheses were studied in the previous papers. They were blended with waxes and emulsifiers in a variety of ratios and synthesized into water repellent PADWC, and it was nylon taffeta treated with and without textile finishing resin. The synthesized water repellents can be used either or without resin. The optimum curing temperature was 150 to 160$^{\circ}C$ and the optimum concentration was 3 to 5wt%. In the independent and conjunct treatment, the water repellency of nylon taffeta samples have no remarkable changes between initial value and that after three times washing, so these prove that the synthesized compounds are durable water repellent. The water repellency of PADWC-3 and -4 were around 90. Also, comparison of crease recovery and tear strength after repelling treatment showed that the synthesized water repellents have a very high softening effect.

A Study on the Synthesis of ACF/PP-g-AAc Hybrid Fibrous Adsorbent by Irradiation and Their Separation Properties of Heavy Metals (방사선 중합법에 의한 ACF/PP-g-AAc 혼성섬유 흡착제의 합성 및 중금속 분리 특성에 관한 연구)

  • 황택성;황대성;박정기
    • Polymer(Korea)
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • The ACF/PP-g-AAc copolymers were synthesized by the irradiational grafting of acrylic acid onto ACF/PP fabric. The synthesis of copolymer was evidenced by the bands at 1720, 3600~3100 $cm^{-1}$ / on FT-IR spectrum. After the adsorption of metal ions on ACF/PP-g-AAc copolymers, the morphology with the small deposits on the fiber surface were observed by SEM. The optimal time for the metal ion adsorption equilibrium on ACF/PP-g-AAc copolymers was 24 hrs and their adsorption capacities increased in the order of Mn$^{2+}$>Cu$^{2+}$>Co$^{2+}$>Ni$^{2+}$. The adsorption capacities of ACF/PP-g-AAc copolymers were invariable after more than 10 times of regeneration.eration.

  • PDF

Studies on the Durable Softners (I) -Synthesis of Alkyl Imidazoline Derivatives- (내구성유연제에 관한 연구 (I) -알킬이미다졸린 유도체의 합성-)

  • Park, Hong-Soo;Kim, Young-Geun;Pyoun, Moo-Sil
    • Applied Chemistry for Engineering
    • /
    • v.1 no.2
    • /
    • pp.197-206
    • /
    • 1990
  • 1, 2-Disubstituted imidazolines, such as 1-behenoyl-aminoethyl-2-heneicosylimidazoline(BHI), 1-behenoylbis(aminoethyl)-2-heneicosylimidazoline(BBI), and 1-behenoyltris(aminoethyl)-2-henoicosylimidazoline(BTI) were synthesized by reacting 3 kinds of polyalkylene polyamines with behenic acid to provide the softness to imidazoline ring.1, 2-Disubstituted imidazolinium chlorides, such as 1-behenoyl-aminoethyl-1-glycidyl-2-heneicosylimidazolinium chloride(BHIC), 1-behenoylbis(aminoethyl)-1-glycidyl-2-henoicosylimidazolinium chloride(BBIC), and 1-behenoyltris(aminoethyl)-1-glycidyl-2-henoicosylimidazolinium chloride(BTIC) were prepared by quaternizing 1, 2-disubstituted imidazoline compounds. The optimum condition for the preparation of BHI, BBI, and BTI was 8 hrs at $210^{\circ}C$. In the synthesis of BHIC, the completely quaternized product was obtained by reacting BHI-epichlorohydrin with 1:1.3 mole ratio, and mole ratios higher than 1:1.5 were required in the preparation of BBIC and BTIC, BHICS, BBICS, and BTICS softners form BHIC, BBIC, and BTIC was treated to acrylic fiber. It was found that were good softners as the softening property was measured.

  • PDF

Studies on the Durable Softners (II) -Applications of Alkyl Imidazoline Derivatives as the Durable Softners- (내구성유연제에 관한 연구 (II) -알킬이미다졸린 유도체의 내구성유연제로서의 응용-)

  • Kim, Young-Geun;Park, Hong-Soo;Song, Kab Jun
    • Applied Chemistry for Engineering
    • /
    • v.1 no.2
    • /
    • pp.168-175
    • /
    • 1990
  • Softners-BHICS, BBICS, and BTICS were prepared from 1, 2-disubstituted imidazoline compounds, such as 1-behenoylaminoethyl-1-glycidyl-2-heneicosylimidazolinium chloride(BHIC), 1-behenoylbis(aminoethyl)-1-glycidyl-2-heneicosylimidazolinium chloride (BBIC), and 1-behenoyltris(aminoethyl)-1-glycidyl-2-heneicosylimidazolinium chloride(BTIC), and treated to acrylic fiber. The measurements of softness, lubricating and antistatic properties showed that they have not only good softness and lubricating property but also a little antistatic property. Furthermore, the initial bending resistance for BBICS and BTICS was 5 grade, and remained 3~4 grade after 5 times washing. As results of these tests, they showed good softner effects having durability. The prepared softners were proved to be durable softner through a series of experimental results for washable properties of feeling by varying treating temperature and pH change.

  • PDF