Purpose: The study was done to measure the effects of maternal heart sound on body weight, physiologic reactions (heart rate [HR] and cortisol) and behavioral states of preterm infants. Methods: Thirty-five preterm infants were recruited from a neonatal intensive care unit at a university hospital. Institutional Review Board approval and informed consent were obtained. The infants were assigned to an experimental group (n=18) with an auditory stimulation for 7 days of life, a continuous delivery of maternal heart sound using MP3 attached inside the incubator, or to a control (n=17) without any auditory stimulation. The outcome variables, daily variations in weight, HR and behavioral states, and differences in cortisol were analyzed. Results: There were differences in variations of daily weights (F=3.431, p=.011) and in cortisol (t=3.184, p=.006) between groups, but no difference in variations of daily HR (F=0.331, p=.933) and behavioral states (F=1.842, p=.323). Conclusion: The findings support the safety of continuous maternal heart sound as no changes in HR and behavioral states occurred, and the efficacy as weight increased and cortisol decreased. This auditory simulation may lead to more efficient utilization of energy in preterm infants by consistently providing familiar sounds from intrauterine life and blocking noxious sounds from NICU environments.
Kim, S.H.;Kim, I.S.;Lee, J.J.;Park, J.A.;Lee, Y.J.;Yeo, J.R.;Bae, S.J.;Lee, S.H.;Chang, Y.
Investigative Magnetic Resonance Imaging
/
v.9
no.2
/
pp.134-139
/
2005
Purpose : To evaluate the usefulness of acoustic noise attenuator on auditory fMRI examination. Materials and methods : The acoustic noise attenuator consists of mask, earmuff and silicon earplug. The soft polyurethane sheet and polyurethane form , which has a good soundproof characteristic were used for mask and earmuff. Auditory fMRI experiments of 500 Hz pure tone stimulation were performed in three different cases; first all of mask, earmuff and earplug, secondly earmuff and earplug only and finally without attenuator in 4 normal hearing volunteers. For data acquisition, BOLD MR imaging technique was employed at a 1.5T MR scanner equipped with high performance gradient system. The raw data were analyzed using a SPM-99 analysis software and the activation maps were obtained. Results : In case of all items of acoustic attenuator used, the results revealed that activation was focused on primary auditory area. When only earmuff and earplug were used, the results showed that the activation spread over primary auditory and secondary associative areas. Last, when no device used, only weak activation was observed on the right auditory cortex. Conclusion : It is expected that the acoustic noise attenuator, which consists of earplugs, earmuffs and mask, is a very useful device in auditory fMRI study.
Journal of rehabilitation welfare engineering & assistive technology
/
v.8
no.2
/
pp.95-99
/
2014
Binaural interaction can recognize the same intensity sound by stimulating two ears alternatively, and it can be record auditory brainstem responses (ABR). However, We needs to be researched about binaural interaction in asymmetric binaural acoustic stimulation. 17 normal young hearing university students were participated. Clicks were presented at the intensity of 90 dB nHL to one ear and the click intensity was increased from 0 to 90 dB nHL with a separation of 10 dB to another ear, simultaneous. BI waveform was obtained by subtracting the sum of the asymmetrically evoked potentials from the binaurally evoked potentials; i.e. BI = B - (L + R). Latency and amplitude was measured 'peak to following trough' of IV-V complex of BI waveform. Threshold of BIC (t-BIC) was obtained using amplitude depend on stimulus intensities (paired sample t-test). Latency shifted in 4.65, 4.63, 4.57, 4.58, 4.62, 4.6, 4.48, 4.36, 4.23 ms for peak, 5.57, 5.51, 5.51, 5.59, 5.61, 5.55, 5.44, 5.28, 5.19 ms for trough, and amplitude shifted in .0.32, -0.3, -0.34, -0.32, -0.42, -0.53, -0.54, -0.61, $-0.67{\mu}V$ from 0 to 90 dB nHL in every 10 dB, respectively. t-BIC was observed 40 dB nHL(p=.001).
Korean Journal of Otorhinolaryngology-Head and Neck Surgery
/
v.61
no.11
/
pp.573-579
/
2018
Background and Objectives Cochlear dead region (CDR) is a region in the cochlear where hearing loss has occurred due to damage to the inner hair cells and/or neurons. Recently, a subjective test involving a pure-tone test in the presence of threshold-equalizing noise (TEN) was introduced to identify CDR. However, for uncooperative patients, such a subjective method would be unsuitable and objective methods would be needed instead to detect CDR. The acoustic change complex (ACC) is an evoked potential elicited by changes in the ongoing sound. In this study, we developed an objective method of identifying CDR by combining ACC response with a TEN test, namely the TEN-ACC test, and investigated its feasibility in normal-hearing listeners. Subjects and Method Ten normal-hearing subjects participated in this study. All subjects underwent both behavioral TEN test and electrophysiological TEN-ACC test. The stimuli for the TEN-ACC test consisted of TEN and embedded pure tones with different frequencies/signals to noise ratios (SNRs). To identify the thresholds, the range SNR of stimulation was varied from 0 to 20 dB, in stages of 4 dB. Results The ACC responses of all subjects who participated in this study were well elicited by stimuli developed for the TEN-ACC test. We confirm that the pure-tones embedded in TEN elicited the objective ACC response. Conclusion The results of this study suggest that the novel TEN-ACC test can be applied to evoke ACC in normal-hearing listeners. Future research should incorporate hearing-impaired listeners to determine the feasibility of the TEN-ACC test as an objective method to identify CDR.
Min Yoon-Ki;Sokhadze Estate M.;Yi ImGap;Jho Moon Jae;Sohn Jin-Hun
Proceedings of the Acoustical Society of Korea Conference
/
spring
/
pp.263-268
/
1999
Psychoacoustic characteristics of automobile hems influence subject's subjective evaluation and psychophysiological reactions on the sounds of car horns. However, differentiation of physiological responses to commercially availablenfluence subject's subjective evaluation and psychophysiological reactions on the s horns is a complicated task due to the small contrast in technical features of horns and the influence of habituation. Using 10 college students, comparative analysis of physiological reactivity was carried out in order to identify the effect of habituation on decrement of psychophysiological responsivity, assess the ability to differentiate subjectively most and least preferred/appropriate horns according to physiological manifestations. EEG and autonomic responses to 7 automobile horns were analyzed during 3 blocks of trials (each block was varied in order for presenting stimuli and acoustic parameters of horns). It was shown that electrodermal and cardiovascular responses had different reactivity patterns to repeated stimulation. Skin conductance variables (SCL, SCR) were habituated as a function of trial. Cardiac reactivity (HR, RSA) showed no signs of habituation. In contrast, sensitization was shown in the vascular component of response (pulse volume). The temporal EEG exhibited marked habituation of fast beta band power, while alpha-blocking effect did not habituate during the course of experiment. Differentiation of physiological responses of most and least preferred/appropriate horns was possible in this study. That is, some cardiovascular reactivity variables (HR, RSA, pulse volume, etc.) were differentiated between the least and the most preferred/appropriate horns during the experiment. However, EEG and electrodermal parameters showed significant differences only during first block of trials and were later affected by habituation.
This numerical study investigates seismicity and fault slip induced by fluid injection in deep geothermal reservoir with pre-existing fractures and fault. Particle Flow Code 2D is used with additionally implemented hydro-mechanical coupled fluid flow algorithm and acoustic emission moment tensor inversion algorithm. The output of the model includes spatio-temporal evolution of induced seismicity (hypocenter locations and magnitudes) and fault deformation (failure and slip) in relation to fluid pressure distribution. The model is applied to a case of fluid injection with constant rates changing in three steps using different fluid characters, i.e. the viscosity, and different injection locations. In fractured reservoir, spatio-temporal distribution of the induced seismicity differs significantly depending on the viscosity of the fracturing fluid. In a fractured reservoir, injection of low viscosity fluid results in larger volume of induced seismicity cloud as the fluid can migrate easily to the reservoir and cause large number and magnitude of induced seismicity in the post-shut-in period. In a faulted reservoir, fault deformation (co-seismic failure and aseismic slip) can occur by a small perturbation of fracturing fluid (<0.1 MPa) can be induced when the injection location is set close to the fault. The presented numerical model technique can practically be used in geothermal industry to predict the induced seismicity pattern and magnitude distribution resulting from hydraulic stimulation of geothermal reservoirs prior to actual injection operation.
After fifteen years of development, Magnetic Resonance (MR) technology for human imaging and spectroscopy is reaching a refined state with FDA approved 3T clinical products from Siemens, GE, and Philips. Broker has cleared CE approval with a 4T system. Varian supports a 4T system platform as well. Shielded magnets are standard at 3T from GE, Oxford, Magnex, and IGC. A shielded 4T whole body magnet is available from Oxford. Stronger switched gradients and dynamic shim coils, desired at any field, areespecially useful at higher static magnetic fields B0. In addition to the higher currents required for higher resolution slice or volume selection afforded by higher SNR, whole body gradient coils will be driven at increasing slew rates to meet the needs of new cardiac applications and other requirements. For example 3T and 4T systems are now being equipped with 2kV, 500A gradient coils and amplifiers capable of generating 4G/cm in 200msec, over a 67+/-cm bore diameter. High field EPI applications require oscillation rates at 1 kHz and higher. To achieve a benchmark 0.2 ppm shim over a 30cm sphere in a high field magnet, at least four stages of shimming need to be considered. 1) A good high field magnet will be built to a homogeneity spec. falling in the range of 100 to 150 ppm over this 30cm spherical "sweet spot" 2) Most modern high field magnets will also have superconducting shim coils capable of finding 1.5 ppm by their adjustment during system installation. 3) Passive ferro-magnetic shimming combined with 4) active, high order room temperature shim coils (as many as five orders are now being recommended) will accomplish 0.2 ppm over the 30cm sphere, and 0.1 ppm over a human brain in even the highest field magnets for human studies. Safety concerns for strong, fast gradients at any B0 field include acoustic noise and peripheral nerve stimulation. One or more of the mechanical decoupling methods may lead to quieter gradients. Patient positioning relative to asymmetric or short gradient coils may limit peripheral nerve stimulation at higher slew rates. Gradient designs combining a short coil for local speed and strength with a longer coil for coverage are being developed for 3T systems. Local gradients give another approach to maximizing performance over a limited region while keeping within the physiologically imposed dB0/dt performance limits.
Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
/
v.21
no.1
/
pp.37-41
/
2010
Background and Objectives : Transient minor voice changes after thyroidectomy are not infrequent complaints even in cases without any evidence of recurrent laryngeal nerve damage. However, clinical course, diagnosis and management of such voice changes are not fully understood. This study aimed to evaluate the clinical characteristics of minor voice changes after thyroidectomy. We also tried to assess the significance and feasibility of superior laryngeal nerve monitoring and to find out the optimal evaluation tools for such voice changes after thyroidectomy. Materials and Method : Nine adult patients who received total thyroidectomy without evidence of recurrent laryngeal nerve injury were enrolled for this prospective study. Voice evaluations were performed preoperatively and 3 months postoperatively ; acoustic analyses including voice range profile, aerodynamic study, stroboscopic evaluation and subjective voice assessment with questionnaires. The external branch of superior laryngeal nerve was monitored by nerve stimulator after ligation of superior thyroidal vessels. Results: Four of nine patients complained their voice change at 3 months after the surgery. Three of them reported complete recovery of their voice at 6 months after the surgery. Acoustic analysis revealed significant decrease in their phonatory range especially with high tone loss. Questionnaires related to singing was more sensitive than previously well-known "voice handicap index". Stimulation of the superior laryngeal nerve was feasible in most of the cases (94.4%), but it failed to show any correlation with minor voice changes after thyroidectomy. Conclusion : Minor voice changes were not rare events during the first 6 month after thyroidectomy. Decrease in phonatory range with high tone loss and therefore, discomfort in singing was the most common finding. Superior laryngeal monitoring was feasible but it was not a sensitive tool for the prediction of minor voice change after thyroidectomy.
Kim, Ju-Young;Kim, Jae-Young;Jung, Hyun-Du;Noh, Si-Cheol;Mun, Chang-Su;Mun, Chi-Woong;Choi, Heung-Ho
Journal of the Institute of Electronics and Information Engineers
/
v.52
no.11
/
pp.127-134
/
2015
Tissue stimulation technique using ultrasound has been continuously studied and developed. Recently, as a increment of interests for obesity treatment and cosmetic care, a various studies on ultrasonic fat emulsification has been conducted. In this study, the fat emulsification adapted ultrasonic transducer was designed. And using designed transducer, the simulation for the shape of focal area and thermal degradation region was conducted. The dimensions were verified by the simulation results. And the effectiveness was confirmed by evaluating measured radiation characteristic and heating characteristic. In addition, we estimated the ultrasonic heating characteristics in composite structure medium. The shape of focal point and heating characteristic of the proposed transducer were determined to be sufficient to emulsify the fat. The results of this study are considered to be used as basic research in more efficient and safe ultrasonic fat removal.
Journal of the Korean Institute of Electrical and Electronic Material Engineers
/
v.37
no.2
/
pp.141-147
/
2024
The measurement of strain under an electric field has been widely employed to comprehend the fundamental principles of electro-mechanical responses in ferroelectric, piezoelectric, and electrostrictive materials. In particular, understanding the strain properties of piezoelectric materials in response to electrical stimulation is crucial for researching and developing components such as piezoelectric actuators, acoustic devices, and ultrasonic generators. This tutorial paper introduces the components and operational principles of the linear variable differential transducer (LVDT), a widely used displacement measurement device in various industries. Additionally, we present the configuration of an experimental setup using LVDT to measure the strain characteristics of ferroelectric, piezoelectric, or electrostrictive materials under the application of an electric field. This paper includes simple measurement results and analyses obtained through the LVDT experimental setup, providing valuable information on research methods for the electro-mechanical interactions of various materials.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.