• Title/Summary/Keyword: Acoustic stimulation

Search Result 33, Processing Time 0.031 seconds

The Effects of Maternal Heart Sound on the Weight, Physiologic Responses and Behavioral States of Premature Infants (산모의 심장소리가 미숙아의 체중, 생리적 반응 및 행동상태에 미치는 효과)

  • Yeum, Mi-Kyung;Ahn, Young-Mee;Seo, Hwa-Sook;Jun, Yong-Hoon
    • Child Health Nursing Research
    • /
    • v.16 no.3
    • /
    • pp.211-219
    • /
    • 2010
  • Purpose: The study was done to measure the effects of maternal heart sound on body weight, physiologic reactions (heart rate [HR] and cortisol) and behavioral states of preterm infants. Methods: Thirty-five preterm infants were recruited from a neonatal intensive care unit at a university hospital. Institutional Review Board approval and informed consent were obtained. The infants were assigned to an experimental group (n=18) with an auditory stimulation for 7 days of life, a continuous delivery of maternal heart sound using MP3 attached inside the incubator, or to a control (n=17) without any auditory stimulation. The outcome variables, daily variations in weight, HR and behavioral states, and differences in cortisol were analyzed. Results: There were differences in variations of daily weights (F=3.431, p=.011) and in cortisol (t=3.184, p=.006) between groups, but no difference in variations of daily HR (F=0.331, p=.933) and behavioral states (F=1.842, p=.323). Conclusion: The findings support the safety of continuous maternal heart sound as no changes in HR and behavioral states occurred, and the efficacy as weight increased and cortisol decreased. This auditory simulation may lead to more efficient utilization of energy in preterm infants by consistently providing familiar sounds from intrauterine life and blocking noxious sounds from NICU environments.

A Study of the Effect of Acoustic Noise Attenuator on Auditory Functional MRI (소음 감쇠기를 이용한 청각의 뇌기능 자기공명영상)

  • Kim, S.H.;Kim, I.S.;Lee, J.J.;Park, J.A.;Lee, Y.J.;Yeo, J.R.;Bae, S.J.;Lee, S.H.;Chang, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.134-139
    • /
    • 2005
  • Purpose : To evaluate the usefulness of acoustic noise attenuator on auditory fMRI examination. Materials and methods : The acoustic noise attenuator consists of mask, earmuff and silicon earplug. The soft polyurethane sheet and polyurethane form , which has a good soundproof characteristic were used for mask and earmuff. Auditory fMRI experiments of 500 Hz pure tone stimulation were performed in three different cases; first all of mask, earmuff and earplug, secondly earmuff and earplug only and finally without attenuator in 4 normal hearing volunteers. For data acquisition, BOLD MR imaging technique was employed at a 1.5T MR scanner equipped with high performance gradient system. The raw data were analyzed using a SPM-99 analysis software and the activation maps were obtained. Results : In case of all items of acoustic attenuator used, the results revealed that activation was focused on primary auditory area. When only earmuff and earplug were used, the results showed that the activation spread over primary auditory and secondary associative areas. Last, when no device used, only weak activation was observed on the right auditory cortex. Conclusion : It is expected that the acoustic noise attenuator, which consists of earplugs, earmuffs and mask, is a very useful device in auditory fMRI study.

  • PDF

Binaural Interaction Component in Auditory Brainstem Responses with Asymmetric Simultaneous Acoustic Stimulation (비대칭 음 강도 양이 동시 자극 청성뇌간유발반응의 양이간섭치)

  • Heo, S.D.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.2
    • /
    • pp.95-99
    • /
    • 2014
  • Binaural interaction can recognize the same intensity sound by stimulating two ears alternatively, and it can be record auditory brainstem responses (ABR). However, We needs to be researched about binaural interaction in asymmetric binaural acoustic stimulation. 17 normal young hearing university students were participated. Clicks were presented at the intensity of 90 dB nHL to one ear and the click intensity was increased from 0 to 90 dB nHL with a separation of 10 dB to another ear, simultaneous. BI waveform was obtained by subtracting the sum of the asymmetrically evoked potentials from the binaurally evoked potentials; i.e. BI = B - (L + R). Latency and amplitude was measured 'peak to following trough' of IV-V complex of BI waveform. Threshold of BIC (t-BIC) was obtained using amplitude depend on stimulus intensities (paired sample t-test). Latency shifted in 4.65, 4.63, 4.57, 4.58, 4.62, 4.6, 4.48, 4.36, 4.23 ms for peak, 5.57, 5.51, 5.51, 5.59, 5.61, 5.55, 5.44, 5.28, 5.19 ms for trough, and amplitude shifted in .0.32, -0.3, -0.34, -0.32, -0.42, -0.53, -0.54, -0.61, $-0.67{\mu}V$ from 0 to 90 dB nHL in every 10 dB, respectively. t-BIC was observed 40 dB nHL(p=.001).

  • PDF

The Objective Test of Cochlear Dead Region Using Acoustic Change Complex: A Preliminary Report (Acoustic Change Complex에 기반한 와우소실영역 검사의 객관적인 방법 제시를 위한 예비 연구)

  • Kang, Soojin;Han, Juhyun;Woo, Jihwan;Park, Hee Sung;Moon, Il Joon;Choi, Kyusung;Hong, Sung Hwa
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.61 no.11
    • /
    • pp.573-579
    • /
    • 2018
  • Background and Objectives Cochlear dead region (CDR) is a region in the cochlear where hearing loss has occurred due to damage to the inner hair cells and/or neurons. Recently, a subjective test involving a pure-tone test in the presence of threshold-equalizing noise (TEN) was introduced to identify CDR. However, for uncooperative patients, such a subjective method would be unsuitable and objective methods would be needed instead to detect CDR. The acoustic change complex (ACC) is an evoked potential elicited by changes in the ongoing sound. In this study, we developed an objective method of identifying CDR by combining ACC response with a TEN test, namely the TEN-ACC test, and investigated its feasibility in normal-hearing listeners. Subjects and Method Ten normal-hearing subjects participated in this study. All subjects underwent both behavioral TEN test and electrophysiological TEN-ACC test. The stimuli for the TEN-ACC test consisted of TEN and embedded pure tones with different frequencies/signals to noise ratios (SNRs). To identify the thresholds, the range SNR of stimulation was varied from 0 to 20 dB, in stages of 4 dB. Results The ACC responses of all subjects who participated in this study were well elicited by stimuli developed for the TEN-ACC test. We confirm that the pure-tones embedded in TEN elicited the objective ACC response. Conclusion The results of this study suggest that the novel TEN-ACC test can be applied to evoke ACC in normal-hearing listeners. Future research should incorporate hearing-impaired listeners to determine the feasibility of the TEN-ACC test as an objective method to identify CDR.

The influence habituation on psychophysiological differentation of automobile horns with different psychoacoustic characteristics (자극 습관화가 자동차 경적음의 심리음향 특성에 따른 심리생리적 予분에 미치는 영향)

  • Min Yoon-Ki;Sokhadze Estate M.;Yi ImGap;Jho Moon Jae;Sohn Jin-Hun
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.263-268
    • /
    • 1999
  • Psychoacoustic characteristics of automobile hems influence subject's subjective evaluation and psychophysiological reactions on the sounds of car horns. However, differentiation of physiological responses to commercially availablenfluence subject's subjective evaluation and psychophysiological reactions on the s horns is a complicated task due to the small contrast in technical features of horns and the influence of habituation. Using 10 college students, comparative analysis of physiological reactivity was carried out in order to identify the effect of habituation on decrement of psychophysiological responsivity, assess the ability to differentiate subjectively most and least preferred/appropriate horns according to physiological manifestations. EEG and autonomic responses to 7 automobile horns were analyzed during 3 blocks of trials (each block was varied in order for presenting stimuli and acoustic parameters of horns). It was shown that electrodermal and cardiovascular responses had different reactivity patterns to repeated stimulation. Skin conductance variables (SCL, SCR) were habituated as a function of trial. Cardiac reactivity (HR, RSA) showed no signs of habituation. In contrast, sensitization was shown in the vascular component of response (pulse volume). The temporal EEG exhibited marked habituation of fast beta band power, while alpha-blocking effect did not habituate during the course of experiment. Differentiation of physiological responses of most and least preferred/appropriate horns was possible in this study. That is, some cardiovascular reactivity variables (HR, RSA, pulse volume, etc.) were differentiated between the least and the most preferred/appropriate horns during the experiment. However, EEG and electrodermal parameters showed significant differences only during first block of trials and were later affected by habituation.

  • PDF

Particle Based Discrete Element Modeling of Hydraulic Stimulation of Geothermal Reservoirs, Induced Seismicity and Fault Zone Deformation (수리자극에 의한 지열저류층에서의 유도지진과 단층대의 변형에 관한 입자기반 개별요소법 모델링 연구)

  • Yoon, Jeoung Seok;Hakimhashemi, Amir;Zang, Arno;Zimmermann, Gunter
    • Tunnel and Underground Space
    • /
    • v.23 no.6
    • /
    • pp.493-505
    • /
    • 2013
  • This numerical study investigates seismicity and fault slip induced by fluid injection in deep geothermal reservoir with pre-existing fractures and fault. Particle Flow Code 2D is used with additionally implemented hydro-mechanical coupled fluid flow algorithm and acoustic emission moment tensor inversion algorithm. The output of the model includes spatio-temporal evolution of induced seismicity (hypocenter locations and magnitudes) and fault deformation (failure and slip) in relation to fluid pressure distribution. The model is applied to a case of fluid injection with constant rates changing in three steps using different fluid characters, i.e. the viscosity, and different injection locations. In fractured reservoir, spatio-temporal distribution of the induced seismicity differs significantly depending on the viscosity of the fracturing fluid. In a fractured reservoir, injection of low viscosity fluid results in larger volume of induced seismicity cloud as the fluid can migrate easily to the reservoir and cause large number and magnitude of induced seismicity in the post-shut-in period. In a faulted reservoir, fault deformation (co-seismic failure and aseismic slip) can occur by a small perturbation of fracturing fluid (<0.1 MPa) can be induced when the injection location is set close to the fault. The presented numerical model technique can practically be used in geothermal industry to predict the induced seismicity pattern and magnitude distribution resulting from hydraulic stimulation of geothermal reservoirs prior to actual injection operation.

MR Technology to 4T

  • Vaughan, Thomas
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.103-105
    • /
    • 2003
  • After fifteen years of development, Magnetic Resonance (MR) technology for human imaging and spectroscopy is reaching a refined state with FDA approved 3T clinical products from Siemens, GE, and Philips. Broker has cleared CE approval with a 4T system. Varian supports a 4T system platform as well. Shielded magnets are standard at 3T from GE, Oxford, Magnex, and IGC. A shielded 4T whole body magnet is available from Oxford. Stronger switched gradients and dynamic shim coils, desired at any field, areespecially useful at higher static magnetic fields B0. In addition to the higher currents required for higher resolution slice or volume selection afforded by higher SNR, whole body gradient coils will be driven at increasing slew rates to meet the needs of new cardiac applications and other requirements. For example 3T and 4T systems are now being equipped with 2kV, 500A gradient coils and amplifiers capable of generating 4G/cm in 200msec, over a 67+/-cm bore diameter. High field EPI applications require oscillation rates at 1 kHz and higher. To achieve a benchmark 0.2 ppm shim over a 30cm sphere in a high field magnet, at least four stages of shimming need to be considered. 1) A good high field magnet will be built to a homogeneity spec. falling in the range of 100 to 150 ppm over this 30cm spherical "sweet spot" 2) Most modern high field magnets will also have superconducting shim coils capable of finding 1.5 ppm by their adjustment during system installation. 3) Passive ferro-magnetic shimming combined with 4) active, high order room temperature shim coils (as many as five orders are now being recommended) will accomplish 0.2 ppm over the 30cm sphere, and 0.1 ppm over a human brain in even the highest field magnets for human studies. Safety concerns for strong, fast gradients at any B0 field include acoustic noise and peripheral nerve stimulation. One or more of the mechanical decoupling methods may lead to quieter gradients. Patient positioning relative to asymmetric or short gradient coils may limit peripheral nerve stimulation at higher slew rates. Gradient designs combining a short coil for local speed and strength with a longer coil for coverage are being developed for 3T systems. Local gradients give another approach to maximizing performance over a limited region while keeping within the physiologically imposed dB0/dt performance limits.

  • PDF

Voice Changes after Thyroidectomy Without Recurrent Laryngeal Nerve Injury (반회후두신경 손상을 동반하지 않은 갑상선 절제술 후 음성 변화)

  • Choi, Jee-Sun;Jeong, Jong-In;Jang, Min-Seok;Son, Young-Ik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.21 no.1
    • /
    • pp.37-41
    • /
    • 2010
  • Background and Objectives : Transient minor voice changes after thyroidectomy are not infrequent complaints even in cases without any evidence of recurrent laryngeal nerve damage. However, clinical course, diagnosis and management of such voice changes are not fully understood. This study aimed to evaluate the clinical characteristics of minor voice changes after thyroidectomy. We also tried to assess the significance and feasibility of superior laryngeal nerve monitoring and to find out the optimal evaluation tools for such voice changes after thyroidectomy. Materials and Method : Nine adult patients who received total thyroidectomy without evidence of recurrent laryngeal nerve injury were enrolled for this prospective study. Voice evaluations were performed preoperatively and 3 months postoperatively ; acoustic analyses including voice range profile, aerodynamic study, stroboscopic evaluation and subjective voice assessment with questionnaires. The external branch of superior laryngeal nerve was monitored by nerve stimulator after ligation of superior thyroidal vessels. Results: Four of nine patients complained their voice change at 3 months after the surgery. Three of them reported complete recovery of their voice at 6 months after the surgery. Acoustic analysis revealed significant decrease in their phonatory range especially with high tone loss. Questionnaires related to singing was more sensitive than previously well-known "voice handicap index". Stimulation of the superior laryngeal nerve was feasible in most of the cases (94.4%), but it failed to show any correlation with minor voice changes after thyroidectomy. Conclusion : Minor voice changes were not rare events during the first 6 month after thyroidectomy. Decrease in phonatory range with high tone loss and therefore, discomfort in singing was the most common finding. Superior laryngeal monitoring was feasible but it was not a sensitive tool for the prediction of minor voice change after thyroidectomy.

  • PDF

A Study on the Design and Fabrication of Fat Emulsification Adapted Focused Ultrasonic Transducer (지방 조직 유화를 위한 집속형 초음파 변환기 설계 및 제작에 관한 연구)

  • Kim, Ju-Young;Kim, Jae-Young;Jung, Hyun-Du;Noh, Si-Cheol;Mun, Chang-Su;Mun, Chi-Woong;Choi, Heung-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.127-134
    • /
    • 2015
  • Tissue stimulation technique using ultrasound has been continuously studied and developed. Recently, as a increment of interests for obesity treatment and cosmetic care, a various studies on ultrasonic fat emulsification has been conducted. In this study, the fat emulsification adapted ultrasonic transducer was designed. And using designed transducer, the simulation for the shape of focal area and thermal degradation region was conducted. The dimensions were verified by the simulation results. And the effectiveness was confirmed by evaluating measured radiation characteristic and heating characteristic. In addition, we estimated the ultrasonic heating characteristics in composite structure medium. The shape of focal point and heating characteristic of the proposed transducer were determined to be sufficient to emulsify the fat. The results of this study are considered to be used as basic research in more efficient and safe ultrasonic fat removal.

Electric-Field-Induced Strain Measurement of Ferroelectric Ceramics Using a Linear Variable Differential Transducer (선형 가변 차동 변압기를 이용한 강유전 세라믹의 전기장 인가에 따른 변형 측정)

  • Hyoung-Su Han;Chang Won Ahn
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.2
    • /
    • pp.141-147
    • /
    • 2024
  • The measurement of strain under an electric field has been widely employed to comprehend the fundamental principles of electro-mechanical responses in ferroelectric, piezoelectric, and electrostrictive materials. In particular, understanding the strain properties of piezoelectric materials in response to electrical stimulation is crucial for researching and developing components such as piezoelectric actuators, acoustic devices, and ultrasonic generators. This tutorial paper introduces the components and operational principles of the linear variable differential transducer (LVDT), a widely used displacement measurement device in various industries. Additionally, we present the configuration of an experimental setup using LVDT to measure the strain characteristics of ferroelectric, piezoelectric, or electrostrictive materials under the application of an electric field. This paper includes simple measurement results and analyses obtained through the LVDT experimental setup, providing valuable information on research methods for the electro-mechanical interactions of various materials.