• 제목/요약/키워드: Acid gas removal

검색결과 123건 처리시간 0.032초

미세조류의 Methane 발효특성

  • 강창민;최명락
    • 한국미생물·생명공학회지
    • /
    • 제24권5호
    • /
    • pp.597-603
    • /
    • 1996
  • This study was carried out to examine degradation characteristics of microalgae Chlorella vulgaris in methane fermentation. We measured COD and VS reduction, gas and methane productivity, VFA (volatile fatty acid), respectively. Then we calculated material balance and hydrolysis rates in soluble and solid material. The substrate concentration was controlled from 14 gCOD$_{cr}$/l to 64 gCOD$_{cr}$/l in batch cultures, and HRT (hydraulic retention time) controlled from 2 days to 30 days in continuous experi- ments. The results were as follows. In batch culture, accumulated gas productivity increased with the increase of the substrate concentration. The SS and VSS was removed all about 30% increase of substrate concentration and the most of the degradable material removed during the first 10 days. The curve of gas and methane production rate straightly increased until substrate concentration is 26 gCOD$_{cr}$/l. In continuous culture experiments, the removal rates at HRT 10days were 20% for total COD and TOC, respectively. At longer HRT, there was no increase in the removal efficiency. At HRT 15 days, the removal rates were 30% for SS and VSS, respectively. Soluble organic materials were rapidly degraded, and so there was no accumulated. Soluble COD concentration was not increase regardless of HRT-increasing. That meaned the hydrolysis was one of the rate-limiting stage of methane fermentation. The first-order rate constants of hydrolysis were 0.23-0.28 day$^{-1}$ for VSS, and 0.07-0.08 day$^{-1}$ for COD.

  • PDF

축산폐수의 혐기성 고정법에 있어서 암모니아성 질소의 영향 (Effect of ammonium nitrogen in anaerobic biofilter using live-stock-wastewater)

  • 엄태규;임정원
    • 상하수도학회지
    • /
    • 제11권4호
    • /
    • pp.43-53
    • /
    • 1997
  • In this research, the synthetic livestock wastewater was prepared to study the characteristics of organic matter removal, the change of VFA production, and the amount of gas production with respect to the change of ammonium nitrogen concentration in the waste using anaerobic fixed bed process, which is an anaerobic biofilm process. The HRT and operation temperature were 1 day and $35{\pm}1^{\circ}C$, respectively. Also, the characteristics of organic matter removal and the inhibitory effect on microorganism in the anaerobic process were studied on the organic loading and ammonium nitrogen concentration. The results obtained were as follows: For COD loading of $10kg/m^3$-day and five levels of ammonium nitrogen concentration ranging from 1,000 to 5,000 mg/L, organic removal efficiencies were about 81, 74, 67, 58, and 51%, and gas productions were 3,860, 3,520, 3,240, 3,020, and 2,790 ml/l-day, respectively. Average methane contents in the gas produced on COD loading of $10kg/m^3$-day was about 76%. Throughout the whole period of experiment, remaining VFA (as COD base) in the effluent was over 90% of remaining COD. This result indicated the inhibitory effect of high concentration of ammonium nitrogen through the facts that accumulated VFA was almost COD and organic removal efficiency decreased also with the increase of ammonium nitrogen. Especially, that implys which high concentration of ammonium nitrogen not only inhibits methane forming bacteria, but also acid forming bacteria.

  • PDF

사워가스 처리기술 및 제거기술 (The Sour Gas Treatment and Removal Technology)

  • 김영철;조진동;오창섭
    • 에너지공학
    • /
    • 제25권1호
    • /
    • pp.171-176
    • /
    • 2016
  • 신흥 선진국들의 급격한 에너지소비 증가와 청정에너지 자원의 고갈로 인해 현재 개발 단가가 높은 미개발 오일 가스 저유지를 개발하고 있는데 이들 오일 가스전은 다량의 부식성 황 화합물($H_2S$)과 $CO_2$, 부탄, 메르캅탄(mercaptan)등을 함유하고 있다. $H_2S$ 가스는 인체에 치명적인 영향을 미치는 독성가스 중 하나이며, $CO_2$ 가스는 지구 온난화에 영향을 가장 많이 미치고 있는 온실가스 중 하나이다. 이러한 유전과 가스전 개발에는 특수 장비와 작업을 안전하게 할 수 있는 고도의 기술력이 필수적이기 때문에 선진국들은 $H_2S/CO_2$ 가스를 함유하고 있는 사워가스/산성가스 처리와 제거기술을 개발하고 있다. 가스전의 가스(raw gas) 처리기술은 저유지의 특성 및 가스에 함유된 $H_2S$의 구성요소들에 의해 좌우된다. 여기서는 많은 양의 황산을 함유하고 있는 오일과 가스에 대한 효율적인 처리 및 처리 비용 그리고 분리장치 기술 및 생산시스템에 관한 문제에 대해서 서술하고자 한다.

반응조 형태 및 슬러지층 유동화 특성에 따른 Upflow Anaerobic Sludge Blanket (UASB) 반응조의 운전효율 (Performance of Upflow Anaerobic Sludge Blanket (UASB) Reactor Depending on Reactor Configuration and Sludge Bed Fluidization)

  • 정병곤
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.179-185
    • /
    • 2006
  • Effect of organic loading rate on UASB performance was evaluated under the renditions of some surface area/reactor volume ratio and different reactor diameter. At the low leading rate of 0.4 kg $COD/m^3{\cdot}d$, reactor performance was not affected by reactor diameter. At the organic loading rate of 6 kg $COD/m^3{\cdot}d$, however, volatile acid accumulation and low COD removal efficiency is observed in reactor having 6.4 cm diameter, while volatile acid is not accumulated at all and high COD removal efficiency is observed in reactor having 3 cm diameter. Such a difference of reactor performance depending on reactor diameter can be explained that sludge bed can be fluidized by evolved gas bubble in narrow reactor, while sludge bed ran not be fluidized by evolved gas bubble only in wide reactor. At a high organic loading rate of 20 kg $COD/m^3{\cdot}d$, it can be judged that there is no relation between reactor configuration and reactor performance because all reactors showed very low COD removal efficiencies regardless of reactor diameter. Narrow and tall type reactor is favorable condition for making sludge bed fluidization at a constant surface area/reactor volume ratio. Thus, it can be judged that reactor configuration and sludge bed fluidization have great influence to reactor performance.

혐기성 고정상반응기와 슬러지 Bed반응기에서 혼합-식품폐수처리에 관한 연구 (A Study on the Mixed-Food Wastewater Treatment in an Anaerobic Packed Bed Reactor and Sludge Bed Reactor)

  • 안재동;김재우;장인용
    • 한국환경보건학회지
    • /
    • 제19권4호
    • /
    • pp.38-43
    • /
    • 1993
  • The characteristics of food wastewater treatment in an anaerobic packed bed reactor (APBR) with polyurethane as a packing material and sludge bed reactor (ASBR) was studied. The reactor of 9cm-ID, 150cm-height was fed in a continuous mode from bottom of reactor. For the purpose of constant temperature of reactor, water jacket was installed. The used packing materials was polyurethane sponge foam. Methane which was produced by decomposed organics collected at the top of the reactor for using as a fuel. The substrates used were synthetic, mixed and food wastewater. For the acclimatization of microorganisms, mixed wastewater was used. The major analyses were gas production, COD, pH and volatile acids. Based upon the completed works, the results are as follows: When food wastewater was fed the quantity of produced gas was less than that of synthetic wastewater, but food process saw higher methane content than synthetic process. As well as COD removal efficiency of food process reached at about 85%. In aspect of effluent volatile acid, food process showed low concentration of below 500 mg/l, therefore anaerobic reaction stabled. Conclusively food wastewater used can be digested by anaerobic treatment, especially anaerobic packed bed reactor showed 82% of COD removal, 75% of methane content, 10 l of gas production, and anaerobic sludge bed reactor did 79% of COD removal, 75% of methane content, 81 of gas production at 4 kgCOD/m$^3$day, 36$\circ$C.

  • PDF

배기가스 처리용 양방향 펄스 전원 (Bidirectional pulse generator for removal of flue gas)

  • 박정호;고광철;강형부
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.233-236
    • /
    • 1997
  • An investigation has been made of the various plasma chemistry reactions that occur in the corona discharge of an electrostatic precipitator operating in a typical flue gas. As the results of investigation, sulphur dioxide is removed principally by reactions with OH radicals to produce sulphuric acid, while nitrogen oxides are removed principally by reduction via the N radical to molecular nitrogen. If electrostatic precipitator\ulcorner used for flue gases are operated with positive voltages instead of negative dc voltages, there are significant reductions in the emission of the undesirable gases SO$_2$, NO, and NO$_2$. Thus, in this paper we design the bidirectional pulse generator for removal of flue gas, where the pulse width is more than 50[nsec] and the maximum output voltage is more than 100[kVl.

  • PDF

Effect of Sulfide Removal on Sulfate Reduction at pH 5 in a Hydrogen Fed Gas-Lift Bioreactor

  • Bijmans, Martijn F.M.;Dopson, Mark;Ennin, Frederick;Lens, Piet N.L.;Buisman, Cees J.N.
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권11호
    • /
    • pp.1809-1818
    • /
    • 2008
  • Biotechnological treatment of sulfate- and metal-ions-containing acidic wastewaters from mining and metallurgical activities utilizes sulfate-reducing bacteria to produce sulfide that can subsequently precipitate metal ions. Reducing sulfate at a low pH has several advantages above neutrophilic sulfate reduction. This study describes the effect of sulfide removal on the reactor performance and microbial community in a high-rate sulfidogenic gas-lift bioreactor fed with hydrogen at a controlled internal pH of 5. Under sulfide removal conditions, 99% of the sulfate was converted at a hydraulic retention time of 24 h, reaching a volumetric activity as high as 51 mmol sulfate/l/d. Under nonsulfide removal conditions, <25% of the sulfate was converted at a hydraulic retention time of 24 h reaching volumetric activities of <13 mmol sulfate/l/d. The absence of sulfide removal at a hydraulic retention time of 24 h resulted in an average $H_2S$ concentration of 18.2 mM (584 mg S/I). The incomplete sulfate removal was probably due to sulfide inhibition. Molecular phylogenetic analysis identified 11 separate 16S rRNA bands under sulfide stripping conditions, whereas under nonsulfide removal conditions only 4 separate 16S rRNA bands were found. This shows that a less diverse population was found in the presence of a high sulfide concentration.

침액식 세정설비의 마이크로버블을 이용한 철강산업 공정의 산세조 발생 염화수소 제거 (Hydrochloric Acid Gas Removal from Iron and Steel Industry Using Micro-bubbles of a Dip Injection Wet Scrubber System)

  • 김예진;정재억;정용준
    • 한국습지학회지
    • /
    • 제17권1호
    • /
    • pp.75-79
    • /
    • 2015
  • 대기오염물질인 염화수소의 배출 규제가 2ppm으로 강화됨에 따라 기존의 제철공장 습식세정 장치에 DIWS 시스템이 도입되었다. 침액식 스크러버 시스템으로 제철공정에서 발생되는 염화수소를 처리하기 위한 파일럿 연구를 수행하였다. DIWS 시스템의 운전에 따른 응축수 pH는 연돌에서 6.0으로 증가하였다. 산세 Fume 정제설비의 평균 유입 염화수소는 13.3ppm, 평균 배출가스는 0.43ppm, 평균 제거율은 96.9%로 나타났다. TMS 장치로 장기간 측정한 데이터를 비교하였을 때 DIWS 장치는 안정적인 제거율을 나타냈지만, TMS의 type별 데이터 불균일 현상이 관찰되었다.

DeSOx/DeNOx 효율 개선을 위한 펄스 코로나 방전하에서 기체미립자 전환반응의 적용 (Application of Gas to Particle Conversion Reaction to increase the DeSOx/DeNOx Efficiency under Pulsed Corona Discharge)

  • 최유리;김동주;김교선
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.249-258
    • /
    • 1998
  • In this paper, we investigated the post-combustion removal of nitrogen oxide($NO_x$) and sulfur oxide($SO_x$) which is based on the gas to particle conversion process by the pulsed corona discharge. Under normal pressure, the pulsed corona discharge produces the energetic free electrons which dissociate gas molecules to form the active radicals. These radicals cause the chemical reactions that convert $SO_x$ and $NO_x$ into acid mists and these mists react with $NH_3$ to form solid particles. Those particles can be removed from the gas stream by conventional devices such as electrostatic precipitator or bag filter. The reactor geometry was coaxial with an inner wire discharge electrode and an outer ground electrode wrapped on a glass tube. The simulated flue gas with $SO_x$ and $NO_x$ was used in the experiment. The corona discharge reactor was more efficient in removing $SO_x$ and $NO_x$ by adding $NH_3$ and $H_2O$ in the gas stream. We also measured the removal efficiency of $SO_x$ and $NO_x$ in a cylinder type corona discharge reactor and obtained more than 90 % of removal efficiency in these experimental conditions. The effects of process variables such as the inlet concentrations of $SO_x$, $NH_3$ and $H_2O$, residence time, pulse frequencies and applied voltages were investigated.

  • PDF

마이크로버블 장치를 이용한 철강산업의 산회수설비 발생 염화수소 가스 처리 (Treatment of Hydrochloric Acid Gas from the Acid Regeneration System of Iron and Steel Industry with Micro-bubble System)

  • 정재억;이광헌;정용준
    • 한국습지학회지
    • /
    • 제25권4호
    • /
    • pp.291-296
    • /
    • 2023
  • 철강산업의 산 회수설비에서 발생하는 염화수소 가스를 처리하기 위하여 마이크로버블을 발생할 수 있는 습식스크러빙 장치(DIWS)가 도입되었다. 산 회수 설비에서 발생하는 염소가스는 수소 가스와 결합하여 염화수소 가스의 농도를 50% 정도 증가시켰다. DIWS장치에 염소 제거를 위한 Na2S2O3를 투입한 이후의 유입수 염화수소 가스 농도는 13.1 ~13.4 ppm, 유출수는 1.5~1.7 ppm이었고, 제거율은 87.5~88.8%로 안정되게 유지하였다. DIWS는 대기배출기준을 안정적으로 만족함에 따라 현장 적용에 적용할 수 있는 공정으로 판단된다.