Ultra Miniature Eddy Current Sensor with 3 Axes for On-Machine-Measurement (기상측정용 3축 구조의 초소형 와전류 센서 개발 및 평가)

  • Kim, Sun-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.3
    • /
    • pp.27-32
    • /
    • 2010
  • The OMM(On-Machine-Measurement) system has many advantages compare to conventional measurement in the way the time and cost. But, the sensor suitable to OMM system is restrictive use. Touch trigger probe sensor has long time for measurement and non-contact sensor has directional demerit. Because the long mechanical parts such as gear and lead screw for pump, injector and machine tools has big and heavy, unclamp and transferring for measurement in machining process is very difficult. This paper presents a development of ultra miniature eddy current displacement sensor with 3 axes for On-Machine-Measurement system. The accuracy of the sensor is experimentally proved in the grinding machine. In experimental results, the accuracy has under ${\pm}5\;{\mu}m$.

The Phase Difference Measurement Module Development for Amplitude Modulated Range Measurement System (진폭 변조 거리 측정 시스템을 위한 정밀 위상차 측정부 개발)

  • Noh, Hyoung-Woo;Park, Jeong-Ho;Kang, Il-Heung;Choi, Mun-Gak;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.182-190
    • /
    • 2011
  • A amplitude modulation(AM) range measuring system utilizes the phase difference of the modulated envelope of the reflected signal to measure the distance. It is known that the AM system has a problem in accuracy due to antenna leakage signals and spurious reflection signals, but an AM range measurement system using an active reflector, which shifts the frequency bands, has been proposed in order to minimize the measurement errors due to spurious signals. In this paper, a new phase measurement module for the AM range measurement system, which enables to measure long distance with good accuracy, is proposed. The modulation frequency is alternatively selected between 8 and 1 MHz, and the measured distance range with this module is up to 150 m within 2 cm accuracy. A JK flip-flop circuit is used for higher phase accuracy, and an XOR circuit is used to cover long distance.

Enhancement of Tracking Performance of Laser Tracking System for Measuring Position Accuracy of Robots

  • Hwang, Sung-Ho;Choi, Gyeong-Rak;Lee, Ho-Gil;Shon, Woong-Hee;Kim, Jin-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.61.5-61
    • /
    • 2001
  • The laser tracking system(LTS) presents the most promising technique for dynamic position measurement of industrial robots. This system combine the advantage of high accuracy with a contactless measurement technique. It is the measurement system of position in three dimensions using distance data obtained by laser interferometer and real time angle by tracking mirror assembly. After measuring the tracking error of the beam projected on the center of retroreflector in robot end effector, this system tracks the end effector continuously by adjusting tracking mirror angle to minimize this error ...

  • PDF

The Exact Position Measurement of Radio Telescope by Multi-photo Analysis (다중영상해석에 의한 전파망원경의 3차원 정밀측정)

  • 강준묵;한승희;엄대용;이주대
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.3
    • /
    • pp.243-253
    • /
    • 2002
  • These days, the application range of digital photogrammetry is being extended actively, so the great variety of research is being progressed about improvement of measurement accuracy. This method can acquisite a high analysis accuracy and can acquisite easily image. But, So this method require a much processing time and effort by increasing a data amount, as the automation of processing must be completed for efficiency improvement of processing. In this study, the automation of image processing stage is established for multi-image aquisition and analysis about a radio telescope. Also, the precise measurement and the accuracy on object were intended to be improved. As a result of this study, the accuracy on the object which demands precise measurement was enhanced from multi image analysis, and also the assembly accuracy of the object could be checked by precise measurement and curve fitting.

A review on the accuracy assessment methods of 3-dimensional digital dental models (디지털 치과모형의 정확도 평가 방법에 대한 고찰)

  • Park, Ji-Su;Lim, Young-Jun;Lee, Jungwon;Kim, Bongju
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.2
    • /
    • pp.55-63
    • /
    • 2019
  • The aim of this article was to review various methods used to evaluate the accuracy of digital dental models. When evaluating the accuracy of digital models, the errors can be reduced by educating examiners and using artificial landmarks. The accuracy evaluation methods of digital dental models are divided into linear measurement, 2-dimensional cross-sectional analysis, and 3-dimensional best fit measurement. As the technology of scanners develops, many studies have been conducted to compare the accuracy of digital impression and conventional impression. According to improvement of scan technologies and development of 3-dimensional model analysis software, the ability to evaluate the accuracy of digital models is becoming more efficient. In this article, we describe the methods for evaluating the accuracy of a digital model and investigate effective accuracy analysis methods for each situation.

Measurement of Coastal Waves using Marine Radar (선박용 레이더를 이용한 연안파 계측)

  • Park, Jun Soo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.1
    • /
    • pp.83-91
    • /
    • 2018
  • In this paper, usefulness of marine radar for water waves measurement in coastal waters is presented. We installed a marine radar to acquire radar images of water wave around light beacon at Jujeon in Ulsan. Also, a series of analysis procedures for obtaining the wave information from the acquired image is described with a schematic diagram. We compared analysis results of radar images with measurement values using wave height gauge at light beacon. In order to improve accuracy of analysis results, detailed water depth information is essential. In conclusion, in case of the use of radar for water waves measurement, it is shown that it is very necessary to increase the accuracy of measurement by consideration of the water depth in the dispersion relation of water waves.

Development and Evaluation of High Speed weigh-in-motion system (고속축하중측정시스템의 개발과 평가)

  • Kim, Ju-Hyun
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.17-26
    • /
    • 2010
  • Maintenance of the roads and bridges is a major issue for all road administrators around the world, and various initiatives are being implemented in each region for the purpose of controlling the ever increasing road maintenance cost while ensuring the safety of the vehicles driving. Efforts for such initiatives have also been made in Asia and initiatives for managing heavy-weight vehicles have recently gained momentum in Korea and Japan. We have developed a technology for unevenly installing bar-shaped sensors (piezo quartz sensors) to enable dynamic axle load measurement at a highly accurate level, and have estimated our measurement accuracy of axle load/gross weight, etc. on an actual road. The measurement accuracy of the axle load/gross weight varies significantly depending on the number of sensors installed. In our implementation, the target accuracy was set to below ${\pm}5%$ for gross weight measurement so that automatic regulation can be applied. We have achieved our target by installing 8-point measurement system. However, to have this technology widely accepted, it was necessary to reduce the system size so that it can be easily implemented. Therefore, we have estimated the relationship between the measurement accuracy and the system size (number of measurement points), and have come up with the proposal of 3-point measurement as an optimum number of measurement points, and have estimated its performance on an actual road. Additionally, we evaluated the relationship between the measurement accuracy and vehicle velocity.

Selection and Verification of Press Forming Pipe Model using Pipefitting (피팅용 프레스 포밍 파이프 성형 모델 선정 및 검증)

  • Kim, TaeGual;Kim, TaeHo;Park, JoonHong;Park, YoungChul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.3
    • /
    • pp.43-49
    • /
    • 2015
  • This paper describes the design of a forged fitting form to acquire a method of product design measurement by target measurement standards. The pipefitting connects each pipe and combines seals and nipples with the pipes normally. Therefore, the section combined with the fitting pipe was measured by a 3D scanner, and the acquired measurement and the design measurement were obtained after modification of the forged fitting pipe by that standard. Moreover, the accuracy of the model was verified through leakage testing of the oil and verification of the design measurement for accuracy decisions on the design measurement after modification of the product.

Measurement of Radial Error Motions of a Rotating Spindle by Moire Topography (모아레 원리를 이용한 스핀들의 반경방향 회전정도 측정)

  • 박윤창;김승우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.11
    • /
    • pp.2723-2729
    • /
    • 1993
  • Moire principles are applied to the measurement of the spindle radial error motion. As opposed to conventional techniques, no master cylinder or ball is needed in the measurement so that the offset and out-of-roundness errors of the master can be inherently eliminated. Two periodic circular gratings are used, one is made on the spindle and the other is held stationary on the reference frame. When the two gratings are seen superimposed during spindle rotation, an interference fringe pattern is observed from which the information on the eccentricity between the two gratings can be extracted with high precision. The optical design and fringe analysis techniques of a prototype measurement system are described in detail with exemplary measurement results.

Point Cloud Measurement Using Improved Variance Focus Measure Operator

  • Yeni Li;Liang Hou;Yun Chen;Shaoqi Huang
    • Current Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.170-182
    • /
    • 2024
  • The dimensional accuracy and consistency of a dual oil circuit centrifugal fuel nozzle are important for fuel distribution and combustion efficiency in an engine combustion chamber. A point cloud measurement method was proposed to solve the geometric accuracy detection problem for the fuel nozzle. An improved variance focus measure operator was used to extract the depth point cloud. Compared with other traditional sharpness evaluation functions, the improved operator can generate the best evaluation curve, and has the least noise and the shortest calculation time. The experimental results of point cloud slicing measurement show that the best window size is 24 × 24 pixels. In the height measurement experiment of the standard sample block, the relative error is 2.32%, and in the fuel nozzle cone angle measurement experiment, the relative error is 2.46%, which can meet the high precision requirements of a dual oil circuit centrifugal fuel nozzle.