• Title/Summary/Keyword: Acceptable Reliability Level

Search Result 116, Processing Time 0.025 seconds

Validation of the Short Form Bobath Memorial Hospital Fall Risk Assessment Scale at a Specialized Geriatric Hospital in Korea (단축형 노인 낙상위험 사정도구의 타당도)

  • Sohng, Kyeong-Yae;Park, Mi Hwa;Chaung, Seung Kyo;Park, Hye Ja
    • Journal of Korean Public Health Nursing
    • /
    • v.28 no.3
    • /
    • pp.495-508
    • /
    • 2014
  • Purpose: This study was conducted in order to evaluate the reliability, validity, sensitivity, and specificity of the Short Form of Bobath Memorial Hospital Fall Risk Assessment Scale (BMFRAS-SF). Methods: A validation study was conducted on 207 elderly patients aged over 65 who were admitted to Bobath Memorial Hospital. Fall risk scores of BMFRAS, composed of eight subscales (age, fall history, physical activity, consciousness level, communication, fall risk factors, underlying disease, and medications) were assessed from the electronic medical record. BMFRAS-SF was derived from eight subscales of the BMFRAS representing the significance between fallers and non-fallers (fall history, physical activity, fall risk factors, underlying disease, and medications). Internal consistency reliability and interrater reliability were assessed by Cronbach's alpha and kappa coefficient. Validity was assessed by Spearman correlation analysis, factor analysis. Sensitivity, specificity, positive predictive and negative predictive values, and a receiver-operating characteristic curve (ROC) were generated. Results: Fallers had significantly higher risk scores than non-fallers in fall history, physical activity, fall risk factors, underlying disease, and medication scales. The BMFRAS-SF demonstrated acceptable Cronbach's alpha (.706) and kappa coefficients of .95. The BMFRAS-SF subscales showed good convergent validity and construct validity. The BMFRAS-SF presented good sensitivity(86.7%), specificity(67.9%), positive predictive value(42.9%) and good negative predictive value(94.8%) at a cut-off score of 5. Areas under the ROC curves were .860 for the BMFRAS and .861 for the BMFRAS-SF. Conclusion: The BMFRAS-SF was proved to be reliable and valid. It could be used for time-saving assessment and evaluation of the high risks for falls in clinical practice settings.

Nursing needs assessment scale for women with infertility: development and validation (난임 여성의 간호 요구 측정 도구 개발 및 타당도 검정)

  • Park, Jummi;Shin, Nayeon;Lee, Kyungmi
    • Women's Health Nursing
    • /
    • v.26 no.2
    • /
    • pp.141-150
    • /
    • 2020
  • Purpose: High-quality nursing care must be provided for women with infertility, and their nursing needs must be identified. Although scales have been developed to assess infertility-related stress, quality of life, and psychosocial status, there is a lack of scales that assess the nursing needs of women with infertility. The purpose of this study was to develop a needs assessment scale for nursing care in women with infertility and to verify its reliability and validity. Methods: The 250 subjects in this study were women with infertility recruited from four hospitals. The scale was developed following the framework of DeVellis, through a literature review, in-depth interviews, development of preliminary items, verification of content validity, development of secondary items, verification of construct validity, and extraction of the final items. Date were analyzed using item analysis, factor analysis, confirmatory factor analysis, Pearson correlation coefficients, and Cronbach's alpha. Reliability was tested using Cronbach's alpha, and validity was evaluated using item analysis, exploratory factor analysis, and criterion validity. Results: The final version of the nursing needs assessment scale for woman with infertility consisted of 18 items. Four factors (physical and psychological nursing needs, needs for information regarding treatment, needs for infertility-related understanding and concern, and supportive needs) explained 66.0% of the total variance. Cronbach's alpha was .92 for the overall instrument and ranged from .88 to .91 for the subscales. Conclusion: These results suggest that this needs assessment scale for nursing care in women with infertility demonstrated acceptable validity and reliability and contained items suitable for assessing the level of nursing care needed by women with infertility.

Empirical Study on the Value Comparison Between Cosmic Radiation Measuring Instruments and Prediction Programs (항공기 탑재 우주방사선 측정장비와 예측프로그램의 비교값 실증연구)

  • Kyu-Wang Kim;Youn-Chul Choi
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.755-762
    • /
    • 2023
  • The reliability of measuring instruments is essential in measuring cosmic radiation. To demonstrate this importance, this study measured and compared the amount of cosmic radiation using Liulin and TEPC, operated in South Korea, on a flight between Incheon, South Korea and LA, the US. In addition, since prior analysis based on a prediction program is necessary in advance to check the dose of cosmic radiation, this study utilized KREAM developed in Korea and the CARI-6M developed by the FAA to acquire the predicted value. As a result of the verification, the reliability of the two devices falls within the acceptable level of 20%, proving the reliability. Moreover, the differences between the values acquired by each prediction program were only subtle. Nevertheless, the analysis demonstrated that the prediction value obtained by the programs and the measured value had significant differences. Therefore, additional correction of the discrepancies or continuous research for such is required to match the predicted values are similar to the actual measured values.

Case Study on Risk Assessment of Railway Infrastructure Sections Using Acceptable Risk Matrix (위험도 매트릭스를 활용한 철도시설물 구간 위험도평가의 사례연구)

  • Shin, Duck-ho;Park, Chan-woo;Chae, Eunkyung;Lee, June-Seok
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.4
    • /
    • pp.550-557
    • /
    • 2017
  • Owing to the established international standards for reliability and safety management of railways and the third-part conformity assessment implementation, quantitative risk assessment focusing on communication system related to railway safety has being implemented. The quantitative risk assessment starts from the establishment of quantitative RAMS requirements; the risk has to be maintained under an acceptable safety level. This paper introduces the risk assessment process based on international standards ; risk assessment was conducted using failure data for railway facilities for about 5.5 years. In addition, based on the results, a scientific risk management method for railway facilities is suggested.

Developing an Instrument to Evaluate Habitual Physical Activity Level of Elementary School-aged Children in Large Populations: A Preliminary Study (초등학생의 일상적 신체활동 측정 도구 개발을 위한 예비조사)

  • An, Ji-Yeon;Tak, Young-Ran
    • Korean Journal of Health Education and Promotion
    • /
    • v.27 no.5
    • /
    • pp.1-14
    • /
    • 2010
  • Objectives: This study is an explorative study for developing an instrument to measure habitual physical activity level of school-aged children. Methods: HPAQ-S consists of 41 items and a self-reported 5-day recall instrument designed to assess habitual physical activity level for school-aged children. For the validity and reliability test, a sample consisted of 28 children, aged 10-11 years old. Results: 41 question items showed an acceptable internal consistency (cronbach's alpha=.89). A significant positive correlation with the pedometer results (r=.69, p<.001) and with Borg's questionnaire (r=.76, p<.001) support the validity of HPAQ-S. Conclusion: HPAQ-S may be more useful for measuring habitual physical activity level of elementary school-aged children in large populations.

A Study of a RealTime OS Based Motor Control System for Laparoscopic Surgery Robot (실시간 운영체제 기반의 복강경 수술 로봇의 모터제어 시스템에 관한 연구)

  • Song, Seung-Joon;Kim, Yong;Choi, Jae-Soon;Bae, Jin-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.218-221
    • /
    • 2006
  • This paper reports on a Realtime OS based motor control system for laparoscopic surgery robot which enables telesurgery and overcomes shortcomings with conventional laparoscopic surgery. The system has a conventional master-slave robot configuration and the control system consists of joint controllers, host controllers, and power units. The robot features (1) a compact slave robot with 5 DOF (Degree Of Freedom) expanding the workspace of each tool and increasing the number of tools operating simultaneously, and (2) direct 1:1 correspondence in the joint of master and slave robot that simplifies control algorithm and enhances reliability. Each master, slave and GUI (Graphical User Interface) host has a dedicated RTOS (RealTime OS), RTLinux-Pro (FSMLabs Inc., U.S.A.) Each master and slave controller set pair has a dedicated CAN (Controller Area Network) channel for control and monitoring signal communication. Total 4 pairs of the master/slave manipulators as current are monitored by one host controller for operation monitoring and higher level motion control. The system showed acceptable performance in both position control precision and master-slave motion synchronization and is now under further development for better safety and control fidelity for clinically applicable prototype.

  • PDF

Reliability and Accuracy of Infrared Temperature: A Systematic Review (적외선 체온의 진단 정확도 평가 연구: 체계적 문헌고찰)

  • Park, Seong-Hi
    • Korean Journal of Adult Nursing
    • /
    • v.26 no.6
    • /
    • pp.668-680
    • /
    • 2014
  • Purpose: The aim of this study was to investigate the accuracy of infrared temperature measurements compared to axillary temperature in order to detect fever in patients. Methods: Studies published between 1946 and 2012 from periodicals indexed in Ovid Medline, Embase, CINAHL, Cochrane, KoreaMed, NDSL, KERIS and other databases were selected using the following key words: "infrared thermometer". QUADAS-II was utilized to assess the internal validity of the diagnostic studies. Selected studies were analyzed through a meta-analysis using MetaDisc 1.4. Results: Twenty-one diagnostic studies with high methodological quality were included representing 3,623 subjects in total. Results of the meta-analysis showed that the pooled sensitivity, specificity, and area under the curve (AUC) of infrared tympanic thermometers were 0.73 (95% CI 0.70~0.75), 0.92 (95% CI 0.91~0.92), and 0.90, respectively. For axillary temperature readings, the pooled sensitivity was 0.67 (95% CI 0.62~0.73), the pooled specificity was 0.87 (95% CI 0.85~0.90), and the AUC was 0.80. Conclusion: Infrared tympanic temperature can predict axillary temperature in normothermic and in febrile patients with an acceptable level of diagnostic accuracy. However, further research is necessary to substantiate this finding in patients with hyperthermia.

Numerical determination of crack width for reinforced concrete deep beams

  • Demir, Aydin;Caglar, Naci
    • Computers and Concrete
    • /
    • v.25 no.3
    • /
    • pp.193-204
    • /
    • 2020
  • In the study, a new, simple and alternative formula is proposed to calculate numerically crack widths of concrete on a finite element (FE) model. By considering more general tension softening behavior of concrete, the proposed expression is derived irrespective of any tension softening model given in the literature or design codes. The test results of six reinforced concrete (RC) deep beams having different geometrical and material properties selected from a recent existing experimental study of the authors are used to verify the accuracy and reliability of the proposed formula and the created numerical FE models of the specimens. Moreover, the crack width results obtained from the FE models are compared with the test results to see the performance of the proposed formula. The results of the study demonstrate that the proposed formula gives very accurate results in a comparison with the test results. The ratios of errors on the results stay commonly at an acceptable level as well. Consequently, the proposed formula is quite simple, unique, and robust to determine crack widths of RC deep beams on an FE model.

공직 적격성 검사의 개발

  • 김청택;김명소;이순묵
    • Proceedings of the Korean Association for Survey Research Conference
    • /
    • 2001.11a
    • /
    • pp.89-109
    • /
    • 2001
  • The purpose of this research was to develop Public Service Aptitude Test(PSAT) in order to select high performer in the public sector of the government. Based on both literature review and job analysis using the interview with job incumbents, the test which measured verbal ability, situational judgment ability, data interpretation ability, and knowledge on common sense was prepared. The items was administered in undergraduate students, job incumbents, and trainees of public service officers to obtain information about the goodness and appropriateness of items. Base on the results of the item analysis, new items were made and administered in another undergraduate students, job incumbents, and trainees of public service officers to select the final test items. The reliability and validity of the developed PSAT were acceptable level. Finally, the impact of the PSAT on potential applicants and future suggestions were discussed.

  • PDF

Generation of synthetic accelerograms using a probabilistic critical excitation method based on energy constraint

  • Bazrafshan, Arsalan;Khaji, Naser
    • Earthquakes and Structures
    • /
    • v.18 no.1
    • /
    • pp.45-56
    • /
    • 2020
  • The application of critical excitation method with displacement-based objective function for multi degree of freedom (MDOF) systems is investigated. To this end, a new critical excitation method is developed to find the critical input motion of a MDOF system as a synthetic accelerogram. The upper bound of earthquake input energy per unit mass is considered as a new constraint for the problem, and its advantages are discussed. Considering this constraint, the critical excitation method is then used to generate synthetic accelerograms for MDOF models corresponding to three shear buildings of 10, 16, and 22 stories. In order to demonstrate the reliability of generated accelerograms to estimate dynamic response of the structures, three target ground motions with considerable level of energy contents are selected to represent "real critical excitation" of each model, and the method is used to re-generate these ground motions. Afterwards, linear dynamic analyses are conducted using these accelerograms along with the generated critical excitations, to investigate the key parameters of response including maximum displacement, maximum interstory drift, and maximum absolute acceleration of stories. The results show that the generated critical excitations can make an acceptable estimate of the structural behavior compared to the target ground motions. Therefore, the method can be reliably implemented to generate critical excitation of the structure when real one is not available.