• 제목/요약/키워드: Accelerated tests

검색결과 551건 처리시간 0.028초

차기 적외선 섬광제 저장수명 예측 (Storage Life Estimation of Next Infrared Flare Material)

  • 백승준;손영갑;김남진;권태수
    • 한국군사과학기술학회지
    • /
    • 제19권3호
    • /
    • pp.311-318
    • /
    • 2016
  • This paper shows storage life estimation of next IR(infrared) flare material through accelerated degradation tests. Three temperature conditions for the accelerated degradation tests are 55, 65 and $75^{\circ}C$. Six performances of IR flare material are burning time, IR peak/continuous Intensity, total energy of near/mid-IR and color ratio, and they were measured after the tests. Storage life of the IR flare material was estimated through both analyzing the degradation data of those performances and applying distribution-based degradation models to the data. Over 30 years of storage life at $20^{\circ}C$ is estimated in terms of IR peak intensity with reliability 0.99 and confidence level 99 %. Additionally, 10 years of storage period at $21^{\circ}C$ would be equivalent to 68 days of accelerated test at $65^{\circ}C$ from the activation energy in Arrhenius model.

Improving the Reliability of a Reciprocating Compressor for Applications in a Refrigerator

  • Woo, Seong-Woo;Chu, Yong-Ho;Ahn, Haeng-Keun
    • 한국재료학회지
    • /
    • 제17권11호
    • /
    • pp.580-586
    • /
    • 2007
  • To enhance the reliability of a newly designed reciprocating compressor applied in a domestic compressor, accelerated life tests were developed using new definitions of the sample size and the $B_1$ life index. In $1^{st}$ accelerated life testing, the compressor was locked due to the fracture of the suction reed valve. The failure modes and mechanisms of the suction reed valve in the accelerated tests were found to be similar to that of the failed product in the field. The root cause of the failure was the overlap between the suction reed valve and the valve plate in the suction port. The missing parameters in the design phase were modified by expanding the trespan size, introducing tumbling process, changing the material and thickness for the valve, introducing a ball peening and brushing process for the valve plate. In $2^{nd}$ accelerated life testing, the compressor was locked due to the interference between the crank shaft and thrust washer. The corrective plan was to heat treat the crank shaft. The $B_1$ life of the compressor improved from 1.5 to 12.9 years.

Study on Properties and Accelerated Life-time Test of Rubber O-ring by Temperature Stress

  • Shin, Young-Ju;Kang, Bong-Sung;Chung, Yu-Kyung;Choi, Kil-Yeong;Shin, Sei-Moon
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2006년도 학술발표대회 논문집
    • /
    • pp.48-54
    • /
    • 2006
  • In this thesis, accelerated life test (ALT) method and procedure for rubber O-ring are applied to assure specified reliability of the products at guaranteeing the life of the products. Rubber O-ring is parts that keep intensity or make machine operation smoothly on attrition portion of machine and is used to prevent that oil is leaked. Usually. Rubber O-ring used NBR that is copolymer of acrylonitrile and butadiene. this are superior oil resistance, heat resistance, durability of abrasion, cold resistance, chemical resistance etc. The accelerated life test model for rubber O-ring are developed using the relationship between stresses and life characteristics of products. Using the accelerated life test method and the acceleration life test equipment which is developed, we performed life test, collected life data and analyzed the results of tests. The proposed accelerated life test method and procedure may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably.

  • PDF

산업용 인버터의 가속 피로수명 평가에 관한 연구 (A Study on Accelerated Fatigue Life Testing for Industrial Inverter)

  • 이상훈;김원진
    • 한국기계가공학회지
    • /
    • 제21권6호
    • /
    • pp.67-73
    • /
    • 2022
  • Industrial inverters are used in a variety of fields for electric power supply. They may be exposed to vibration and heat once they are installed. This study focused on a framework of accelerated life testing of an industrial inverter considering fatigue damage as the primary source of deterioration. Instead of analyzing detailed failure mechanisms and the product's vulnerability to them, the potential of fatigue failure is considered using the fatigue damage spectrum calculated from the environmental vibration signals. The acceleration and temperature data were gathered using field measurement and spectral analysis was conducted to calculate the vibration signal's power spectral density (PSD). The fatigue damage spectrum is then calculated from the input PSD data and is used to design an accelerated fatigue life testing. The PSD for the shaker table test is derived that has the equivalent fatigue damage to the original input signal. The tests were performed considering the combined effect of random vibration and elevated temperature, and the product passed all the planned tests. It was successfully demonstrated that the inverter used in this study could survive environmental vibration up to its guarantee period. The fatigue damage spectrum can effectively be used to design accelerated fatigue life testing.

Optimum Design of Accelerated Degradation Tests for Lognormal Distribution

  • Lee, Nak-Young
    • 품질경영학회지
    • /
    • 제23권1호
    • /
    • pp.29-40
    • /
    • 1995
  • This paper considers the problem of optimally designing accelerated degradation tests in which the performance value of a specimen is measured only at one of three test conditions for a given exposure time. For the product having lognormally distributed performance, the optimum plan-low stress level and sample proportion allocated to each test condition - is obtained, which minimize the asymptotic variance of maximum likelihood estimator of a stated quantile at design stress. An illustrative example for the optimum plan is given.

  • PDF

Optimal Plan for Fully Accelerated Life Tests with Three-Step Stress Under Type I Censoring

  • Moon, Kyoung-Ae;Shin, Im-Hee
    • Journal of the Korean Data and Information Science Society
    • /
    • 제7권2호
    • /
    • pp.295-299
    • /
    • 1996
  • In this paper, optimal change times are determined for fully three-step stress accelerated life tests, which minimize the asymptotic variance for maximum likelihood estimator of logarithm of the failure rate at the usual condition and exponential distribution is given for life time data.

  • PDF

Optimal Designs for Constant Stress Partially Accelerated Life Tests under Type I Censoring

  • Moon, Gyoung-Ae
    • Journal of the Korean Data and Information Science Society
    • /
    • 제6권2호
    • /
    • pp.77-83
    • /
    • 1995
  • The inferences on a series system under the usual condition using data from constant stress partially accelerated life tests and type I censoring is studied. Two optimal designs to determine the sample proportion allocated each stress level model are also presented, which minimize the sum of the generalized asymptotic variances of maximum likelihood estimators of the failure rate and the acceleration factors and the sum of the asymptotic variances of maximum likelihood estimators of the acceleration factors for each component. Each component of a system is assumed to follow an exponenial distribution.

  • PDF

스트레스함수가 균등분포인 가속수명시험 (Accelerated Life Tests under Uniform Stress Distribution)

  • 원영철
    • 대한안전경영과학회지
    • /
    • 제2권2호
    • /
    • pp.71-83
    • /
    • 2000
  • This paper presents accelerated life tests for Type I censoring data under probabilistic stresses. Probabilistic stress, $S_j$, is the random variable for stress influenced by test environments, test equipments, sampling devices and use conditions. The hazard rate, ,$theta_j$, is the random variable of environments and the function of probabilistic stress. Also it is assumed that the general stress distribution is uniform, the life distribution for the given hazard rate, $\theta$, is exponential and inverse power law model holds. In this paper, we obtained maximum likelihood estimators of model parameters and the mean life in use stress condition.

  • PDF

성능특성치의 열화가 대수정규분포를 따를 때의 가속열화시험 모형 개발 (Planning of Accelerated Degradation Tests: In the Case Where the Performance Degradation Characteristic Follows the Lognormal Distribution)

  • 임헌상;성시일
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제18권1호
    • /
    • pp.80-86
    • /
    • 2018
  • Purpose: This article provides a mathematical model for the accelerated degradation test when the performance degradation characteristic follows the lognormal distribution. Method: For developing test plans, the total number of test units and the test time are determined based on the minimization of the asymptotic variance of the q-th quantile of the lifetime distribution at the use condition. Results: The mathematical model for the accelerated degradation test is provided. Conclusion: Accelerated degradation test method is widely used to evaluate the product lifetime within a resonable amount of cost and time. In this article. a mathematical model for the accelerated degradation test method is newly developed for this purposes.

국산 고체 알루미늄 전해 커패시터의 가속수명시험 개발 및 국외 선진업체 제품과의 특성 비교 (Development of Accelerated Life Tests for Solid Aluminum Electrolyte Capacitor Made by Domestic Manufacturing Company and Comparison of Characteristics between Domestic Products and Foreign Advanced Products)

  • 박정원;이중휘
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제2권1호
    • /
    • pp.1-14
    • /
    • 2002
  • High temperature operating test, temperature humidity test and temperature cycling were performed at various test levels for solid aluminum electrolyte capacitors made by domestic manufacturing company and foreign advanced manufacturing company. It was found that main failure mode of solid aluminum electrolyte capacitors was the decrease of their capacitances. The decrease of their capacitances has the same pattern in these tests. Test result for comparison of characteristics between domestic products and foreign advanced products shows that domestic products have the shorter lifetime and their capacitances decrease more rapidly in high temperature operating test and temperature humidity test. Also in these tests, accelerated tests for high temperature operating test and temperature humidity test were developed.

  • PDF