• Title/Summary/Keyword: Accelerated tests

Search Result 553, Processing Time 0.022 seconds

Study on the Fatigue Test and the Accelerated Life Test for Dental Implant using Universal-Joint Test Type (유니버설조인트 시험방식을 이용한 치과용 임플란트의 피로시험 및 가속수명시험에 관한 연구)

  • Do, Gyeong Hun;Lee, Seok Jin;Kim, Jong Mi;Kim, Sung Min
    • Journal of Applied Reliability
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • Purpose : This paper is a comparative analysis results of the fatigue test for dental implants and accelerated life test by using a static type loading device commonly used in Korea and a dynamic type loading device (universal-joint) recommended by FDA. Methods : Fatigue tests of dental implant is based on ISO 14801 and classified into static load test and dynamic load test. The tests were carried out on three test specimens by four load stress steps under each loading device. For analysis on failure mode such as crack, fracture and permanent deformation of test specimens, we used X-ray three-dimensional computed tomography on test specimens before and after the fatigue tests. The design of the accelerated life test was based on the analysis results of the fatigue life data obtained from the dynamic load test and the statistical analysis software (Minitab ver.15) was used to analyze the appropriate life distribution. Results : As a result of the fatigue tests and the accelerated life tests at same acceleration condition under each test method, the fatigue life under the dynamic type loading device (universal-joint) was shorter than when static type loading device was applied. Conclusion : This paper can be used as a reference when the universal-joint type loading device for implants fatigue test is applied as ISO 14801.

Application of Accelerated Degradation Testing for VFD (Vacuum Fluorescent Display) (VFD(Vacuum Fluorescent Display) 가속열화시험 응용사례)

  • Bae, Suk-Joo
    • Journal of Applied Reliability
    • /
    • v.5 no.4
    • /
    • pp.413-425
    • /
    • 2005
  • As an alternative to traditional life testing, degradation tests can be effective in assessing product reliability when measurements of degradation leading to failure can be observed. This article presents an accelerated degradation testing for vacuum fluorescent displays (VFDs). The accelerated degradation model is based on Arrhenius-lifetime relationship for cathode temperatures. We compare the results between accelerated degradation test and test at normal use condition. Accelerated degradation test for display devices is observed as an efficient method to warrantee product reliability to customers, as well as a tool to save time and costs.

  • PDF

Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts (염해 및 복합열화에 의한 부식촉진시험과 장기폭로 시험의 상관성에 관한 연구)

  • Park, Sang Soon;Lee, Min Woo
    • Corrosion Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.214-223
    • /
    • 2014
  • Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were inuestigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition.

A Study on Goodness of Fit Test in Accelerated Life Tests (가속수명시험에 대한 적합도 검정에 관한 연구)

  • Lee, Woo-Dong;Cho, Geon-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.7 no.1
    • /
    • pp.37-46
    • /
    • 1996
  • In this paper, we introduce the goodness of fit test procedure for lifetime distribution using step stress accelerated lifetime data. Using the nonpapametric estimate of acceleration factor, we prove the strong consistence of empirical distribution function under null hypothesis. The critical vailues of Kolmogorov-Smirnov, Anderson-Darling, Cramer-von Mises statistics are computed when the lifetime distibution is assumed to be exponential and Weibull. The power of test statistics are compared through Monte-Cairo simulation study.

  • PDF

Optimal three step-stress accelerated life tests for Type-I hybrid censored data

  • Moon, Gyoung Ae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.1
    • /
    • pp.271-280
    • /
    • 2015
  • In this paper, the maximum likelihood estimators for parameters are derived under three step-stress accelerated life tests for Type-I hybrid censored data. The exponential distribution and the cumulative exposure model are considered based on the assumption that a log quadratic relationship exits between stress and the mean lifetime ${\theta}$. The test plan to search optimal stress change times minimizing the asymptotic variance of maximum likelihood estimators are presented. A numerical example to illustrate the proposed inferential procedures and some simulation results to investigate the sensitivity of the optimal stress change times by the guessed parameters are given.

Analyses of Accelerated Life Tests Data from General Limited Failure Population (GLFP 모형하에서의 가속수명시험 데이터 분석)

  • Kim, Chong-Man
    • Journal of Korean Society for Quality Management
    • /
    • v.36 no.1
    • /
    • pp.31-39
    • /
    • 2008
  • This paper proposes a method of estimating the lifetime distribution at use condition for constant stress accelerated life tests when an infant-mortality failure mode as well as wear-out one exists. General limited failure population model is introduced to describe these failure modes. It is assumed that the log lifetime of each failure mode follows a location-scale distribution and a linear relation exists between the location parameter and the stress. An estimation procedure using the expectation and maximization algorithm is proposed. Specific formulas for Weibull distribution are obtained. An illustrative example and the simulation results are given.

Analysis on Weathering Characteristics of Rocks in Dokdo by Accelerated Weathering Test (풍화가속실험을 통한 독도 암체의 풍화특성 분석)

  • Song, Won-Kyong;Woo, Ik;Kim, Bok-Chul
    • Tunnel and Underground Space
    • /
    • v.19 no.4
    • /
    • pp.318-327
    • /
    • 2009
  • Accelerated weathering tests was executed to understand the physical characteristics of rocks in Dokdo. For the tests rock samples including trachytic andestes, andesite dyke and ash tuff were taken in place. Double soxhlet extractor and peristatic pump were used for accelerating the weathering processes. After the tests for 4 months, the variations of superficial structure, microscopic structure and strength of rock samples were observed.

Characteristics of Accelerated Aging in Generator Stator Windings (발전기 고정자 권선의 가속열화 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.279-280
    • /
    • 2008
  • Accelerated aging tests were conducted under laboratory conditions on two generator stator bars. Electrical stress is applied in No. 1 model stator bar. Electrical and thermal stresses are applied in No. 2 model stator bar. As aging times increased from 0 to 4780h, diagnostic tests were performed on No. 1 and No. 2 model stator bars. Diagnostic tests included AC current, dissipation factor(tan$\delta$) and partial discharge magnitude. The ${\Delta}tan{\delta}$ and $\Deta$I of No. 1 and No. 2 model stator bars increased with increased in aging time.

  • PDF

Optimal Design of Accelerated Degradation Tests with Two Stress Variables in the Case that the Degradation Characteristic Follows Weibull Distribution (열화특성치가 와이블분포를 따르는 경우 두 가지 스트레스 변수를 고려한 가속열화시험의 최적 설계)

  • Lim, Heonsang;Kim, Yong Soo
    • Journal of Applied Reliability
    • /
    • v.13 no.2
    • /
    • pp.87-98
    • /
    • 2013
  • Accelerated degradation tests (ADTs) measuring failure-related degradation characteristic at the accelerated condition are widely used to assess the reliability of highly reliable products. Often, however, little degradation could be observed even in single-stress ADTs due to the high reliability of test unit, and as a result poor estimate of the reliability may be obtained. ADTs with multiple stress variables can be employed to overcome such difficulties. In this paper, optimal ADT plans with two stress variables are developed assuming that the degradation characteristic follows Weibull distribution by determining the stress levels, the proportion of test units allocated to each stress level such that the asymptotic variance of the maximum likelihood estimator of the q-th quantile of the lifetime distribution at the use condition is minimized.

Influence of natural and accelerated weathering of polycarbonate (폴리카보네이트 소재의 자연폭로와 실내촉진 내후성 영향)

  • Moon, Jung-mi;Jang, Ho-Jin;Kim, Chang-Hwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.6
    • /
    • pp.383-389
    • /
    • 2022
  • Natural(outdoor) and accelerated(artificial) weathering tests were performed to investigate their influence on polycarbonate. The polycarbonate materials were prepared of various formulations divided into three batches, with existing, development materials1, development materials2, containing mixture of UV additives. Weathering tests were carried out as outdoor weathering(Seosan, South Korea) and accelerated weathering(xenon-arc), and the results analysis were evaluated based on yellow-index(YI), scanning electron microscope(SEM/EDS), energy dispersive x-ray spectroscopy(XRD), and gel permeation chromatography(GPC). Among the three materials, processing method development materials1 with UV stabilizer was excellent in weathering. This study can provide basic data for standardization of development and performance evaluation on livestock barn roof.