• Title/Summary/Keyword: Ac

Search Result 8,884, Processing Time 0.04 seconds

Cost Analysis of Modified Asphalts using a Performance Based Fracture Criterion (공용성에 근거한 파괴기준을 이용한 개질 아스팔트 포장의 비용 효과 분석)

  • Kim, Boo-Il
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.49-56
    • /
    • 2005
  • The effect of modified asphalts is evaluated by simple comparison of a single parameter (i.e., tensile strength, stiffness, etc.) between modified asphalt mixture and unmodified mixture. The use of a single parameter to evaluate the effect of modified asphalt must be questioned. Rather, a single unified framework that accounts for changes in key mixture properties is needed to effectively evaluate the modified asphalt mixtures. This study used a new performance-based fracture parameter as a single unified framework, the Energy Ratio (ER), for quantifying the effect of modified asphalts oil the fracture resistance of mixtures. The Energy Ratio was then used as a performance criterion for calculating the construction cost of two modified asphalt pavements (SBS and Crumb Rubber) and unmodified asphalt pavement. The results showed that the Energy Ratio of SBS modified asphalt was higher than those of crumb rubber and unmodified asphalt. Cost analyses indicated that the construction cost of the AC layer would be reduced by up to 24% by SBS modification. Based on the results, the Energy Ratio is capable of evaluating the effect of modified mixtures, and may form the basis of a promising fracture criterion for performance-based thickness design in asphalt pavements.

  • PDF

Correlation Analysis of Binder Stiffness with Deformation Strength and Dynamic Creep Property of Asphalt Mixtures for Evaluation of Kim Test Applicability (바인더 Stiffness와 혼합물의 변형강도 및 동적크리프 특성과의 상관성 분석을 통한 김테스트 적용성 고찰)

  • Kim, Kwang-Woo;Doh, Young-Soo;Cho, Mun-Jin
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.91-102
    • /
    • 2005
  • This study dealt with correlation analysis of binder stiffness with deformation strength and dynamic creep property of asphalt mixtures for evaluation of applicability of deformation strength $(S_D)$. Two aggregates, with maximum size of 13mm and eight binders were used to produce 16 different mixtures. The stiffness of binder $(G^*/sin\delta)$ was measured using DSR at $64^{\circ}C$. Final deformation(FD) and dynamic stability(DS) were measured by dynamic creep (DC) test, and SD was measured by Kim test for each mixture. Results of correlation analysis between $G^*/sin\delta$, and $S_D$, m and DS showed that correlation with binder stiffness and deformation strength was the highest $(R^2>0.88)$. There was good correlation between DS, FD with $S_D$. The results indicated that rut-resistance property of mixture is better reflected in $S_D$ test than FD or DS of dynamic creep test. Therefore, it is concluded that $S_D$ can be possibly used for evaluation of rut resistance of asphalt concretes with a good reliability if the procedure is standardized.

  • PDF

Input Balun Design Method for CMOS Differential LNA (차동 저 잡음 증폭기의 입력 발룬 설계 최적화 기법)

  • Yoon, Jae-Hyuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.366-372
    • /
    • 2017
  • In this paper, the analysis of baluns that are inevitably required to design a differential low noise amplifier, The balun converts a single signal input from the antenna into a differential signal, which serves as an input to the differential amplifier. In addition, it protects the circuit from ESD(Electrostatic Discharge) coming through the antenna and helps with input matching. However, in the case of a passive balun used in general, since the AC signal is transmitted through electromagnetic coupling formed between two metal lines, it not only has loss without gain but also has the greatest influence on the total noise figure of the receiving end. Therefore, the design of a balun in a low-noise amplifier is very important, and it is important to design a balun in consideration of line width, line spacing, winding, radius, and layout symmetry that are necessary. In this paper, the factors to be considered for improving the quality factor of balun are summarized, and the tendency of variation of resistance, inductance, and capacitance of the balun according to design element change is analyzed. Based on the analysis results, it is proved that the design of input balun allows the design of low noise, high gain differential amplifier with gain of 24 dB and noise figure of 2.51 dB.

Fabrication Ba0.5Sr0.5Co0.8Fe0.2O3−δ (BSCF)/Ce0.9Gd0.1O2−δ (GDC) and La0.6Ba0.4Co0.2Fe0.8O3−δ (LBCF)/Ce0.9Gd0.1O2−δ (GDC) Composite Cathodes for Intermediate Temperature Solid Oxide Fuel Cells (중저온 SOFC용 Ba0.5Sr0.5Co0.8Fe0.2O3−δ (BSCF)/Ce0.9Gd0.1O2−δ (GDC) 및 La0.6Ba0.4Co0.2Fe0.8O3−δ (LBCF)/Ce0.9Gd0.1O2−δ (GDC) 복합체 양극 제조)

  • Lee, Seung-Hun;Yoon, Song-Seol;Cha, Young-Chul;Lee, Jun;Hwang, Hae-Jin;Moon, Ji-Woong
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.12
    • /
    • pp.740-746
    • /
    • 2007
  • The potential candidates for IT-SOFCs cathode materials, $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ (BSCF) and $La_{0.6}Ba_{0.4}Co_{0.2}Fe_{0.8}O_{3-{\delta}}$ (LBCF) powders, were synthesized by a EDTA-citrate combined method from $Sr(NO_3)_2$, $Ba(NO_3)_2$, $La(NO_3)_3{\cdot}6H_2O$, $Co(NO_3)_2{\cdot}6H_2O$, $Fe(NO_3)_3{\cdot}9H_2O$, citric acid and $EDTA-NH_3$. The cathode performance of symmetrical electrochemical cells consisting of BSCF-GDC or LBCF-GDC composite electrodes and a GDC electrolyte was investigated using by AC impedance spectroscopy at the temperature range of 500 to $700^{\circ}C$. It was found that a single phase perovskite could be successfully synthesized when the precursor is heated at $850^{\circ}C$ for 2 h. Due to thermal expansion mismatch between BSCF and GDC, the composite cathodes with lower GDC content than 45 wt% were peeled off from the GDC electrolyte and their electrode polarization resistance was estimated to be high. The thermal expansion coefficient of BSCF-GDC composites was decreased with increasing the GDC content and the electrode peeling off did not occur in BSCF-45 and 55 wt% GDC composites. BSCF-45 wt% GDC composite electrode showed the lowest area specific resistances (ASR) of 0.15 and $0.04{\Omega}{\cdot}cm^2$ at 600 and $700^{\circ}C$, respectively. On the other hand, LBCF-GDC composite cathodes showed higher ASR than the BSCF-45 and 55 wt% GDC and their cathode performance were decreased with the GDC content.

Effect of Vinyl Ethylene Carbonate on Electrochemical Characteristics for Activated Carbon/Li4Ti5O12 Capacitors (활성탄/리튬티탄산화물 커패시터의 전기화학적 특성에 미치는 비닐에틸렌카보네이트의 영향)

  • Kwon, Yong-Kab;Choi, Ho-Suk;Lee, Joong-Kee
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.190-197
    • /
    • 2012
  • We employed the vinyl ethylene carbonate (VEC) as an electrolyte additive and investigated the effect of the electrolyte additive on the electrochemical performance in hybrid capacitor. The activated carbon was adopted as cathode material, and the $Li_4Ti_5O_{12}$ oxide was used as anode material. The electrolyte was prepared with the $LiPF_6$ salt in the mixed solvent of ethylene carbonate (EC), dimethyl carbonate (DMC), and ethyl methyl carbonate(EMC). We evaluated the electrochemical performance of the hybrid capacitor with increasing the amount of the VEC electrolyte additive, which is known as the remover of oxygen functional group and the stabilizer of the electrode by reducing the surface of electrode, and obtained the superior performance data especially at the addition of the VEC electrolyte additive of around 0.7 vol%. On the contrary, the addition of the VEC more than 0.7 vol% in the electrolyte leads to the degradation in electrochemical performance of hybrid capacitor, suggesting the increase of the side reaction from the excessive VEC additive. X-ray photoelectron spectroscopy (XPS) revealed that the addition of the VEC suppressed the formation of LiF component, which is known as the insulator, on the surface of electrode. The optimized addition of VEC exhibited the improved capacity retention around 82.7% whereas the bare capacitors without VEC additive showed the 43.2% of capacity retention after 2500 cycling test.

Adaptive 1-D Transforms Order Selection Methods for Performance Improvement of SA-DCT (SA-DCT 성능 향상을 위한 적응적 1차원 변환 순서선택방법)

  • Song, Joon-Ho;Moon, Joo-Hee;Chung, Jae-Won
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.4
    • /
    • pp.442-454
    • /
    • 2002
  • It's noticed that the SA-DCT (Shape-Adaptive Discrete Cosine Transform) produces different 2-dimensional transform coefficients according as the first 1-dimensional transform is applied in horizontal or vertical direction for an arbitrarily shaped boundary block. Performing the first 1-dimensional transform in the direction, which has higher spatial correlation or smaller shifting distance, can compact the energy on the smaller number of AC coefficients around DC. This paper shows, experimentally, the compaction capability improvement by choosing the first 1-dimensional transform direction with higher spatial correlation or smaller shifting distance. Two adaptive selection methods are proposed to decide efficiently the spatial direction with higher correlation in a boundary block. One is based on the gradients between DC coefficients of neighboring and current blocks, and the other is based on the final coding efficiency that means the number of bits required for coding the block. Using the MPEG-4 video coder, the proposed method shows coding efficiency gain up to 10.87% compared to the conventional SA-DCT method.

A Case Analysis of Home Health Care for Cesarean Postpartum Women and Their Newborns (제왕절개분만 산욕부와 신생아의 가정간호 사례분석)

  • 김혜숙;최연순;전은미
    • Journal of Korean Academy of Nursing
    • /
    • v.24 no.4
    • /
    • pp.696-705
    • /
    • 1994
  • This study was done to provide a basis for home health care management for women following Cesarean delivery. Furthermore it was initiated as an possible application of home health care in the future. In this study, client selection criteria was developed by the researcher and assessment tools for home health care, recording system and problem oriented recording system were revised from Jun's(1993) methods. The selection criteria tool for home health care for women who had a Cesarean delivery was structured and consisted of five areas : physical status, functional status, psychological-emetional status, educational needs status and environmental status. The structured assessment tool consisted of general items, obstetric history, past medical history, methods of feeding, medications taken before ad-mission, laboratory results, discharge instructions, discharge medications, family tree, economic status, environmental status, a map, health assessment of women and their newborns. The visit note consisted of the date : nursing problems : nursing process including initial assessment : nursing goals : visit plan : health status of the postpartum women and their newborn : nursing diagnoses : nursing implementation evaluation : summary : next visit plan and revision. The problem oriented recording system consisted of the date, problem numbers, nursing diagnoses, problem appearance date, problem resolution date. The results of the research are as follows : The seven cases having had a Cesarean delivery were discharged on an average on the 5th day after the Cesarean birth. The total number of home visits was 13. According to Cordon's functional health patterns the total possible nursing diagnoses was 34 diagnoses for the methers and their newborns. Among the 34 diagnoses, there were 13 diagnoses in the health perception /management pattern, 7 in the psychosocial health perception / management pattern, 8 in the psychosocial self-perception, 2 in the nutrition / metabolism pattern of physical function, 2 in the knowledge deficit of newborn management, anxiety related to newborn management, knowledge deficit related to disease process of new-born, anxiety related to disease process of newborn anxiety related to prognosis of baby's condition, knowledge deficit related to newborn jaundice each appeared once. The changes in the number of nursing diagnoses was related to not the number of visits but to the number of nursing diagnoses decreasing. The con-tent of the home health care was categorized ac-cording to assessment, direct care, counseling, education, family care. The recommendation based on the results of this research are Home health care nurses for Cesarean postpartum women and their neonates requires comprehensive knowledge of pregnancy, delivery, and the postpartum period and of the neonate so that they can provide appropriate care and holistic views. Most of cases terminated after the second visit, this outcome may be related to the subjects being discharged on the 5th day after delivery. Therefore, study done with earlier discharge after delivery may have different outcome. It is very hard to assess psychological aspects that need follow-up and to develop communication channels.

  • PDF

Economic and Environmental Assessment of a Renewable Stand-Alone Energy Supply System Using Multi-objective Optimization (다목적 최적화 기법을 이용한 신재생에너지 기반 자립 에너지공급 시스템 설계 및 평가)

  • Lee, Dohyun;Han, Seulki;Kim, Jiyong
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.332-340
    • /
    • 2017
  • This study aims to propose a new optimization-based approach for design and analysis of the stand-alone hybrid energy supply system using renewable energy sources (RES). In the energy supply system, we include multiple energy production technologies such as Photovoltaics (PV), Wind turbine, and fossil-fuel-based AC generator along with different types of energy storage and conversion technologies such as battery and inverter. We then select six different regions of Korea to represent various characteristics of different RES potentials and demand profiles. We finally designed and analyzed the optimal RES stand-alone energy supply system in the selected regions using multiobjective optimization (MOOP) technique, which includes two objective functions: the minimum cost and the minimum $CO_2$ emission. In addition, we discussed the feasibility and expecting benefits of the systems by comparing to conventional systems of Korea. As a result, the region of the highest RES potential showed the possibility to remarkably reduce $CO_2$ emissions compared to the conventional system. Besides, the levelized cost of electricity (LCOE) of the RES-based energy system is identified to be slightly higher than conventional energy system: 0.35 and 0.46 $/kWh, respectively. However, the total life-cycle emission of $CO_2$ ($LCE_{CO2}$) can be reduced up to 470 g$CO_2$/kWh from 490 g$CO_2$/kWh of the conventional systems.

Interpretation of Receiver Operating Characteristics (ROC) (ROC(receiver operating characteristics) 해석)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.30 no.3
    • /
    • pp.155-158
    • /
    • 2000
  • The purpose of this paper is to explain the making procedure and the usage of receiver operating characteristic (ROC) curve for interpretation of radiographic images. The conventional radiograms obtained after the creation of the lesions in the acrylic plates and were enhanced in color. The observer were informed of which tooth to examine, the 'a priori' probability of a lesion present and the approximate diameter of the lesions. The two groups of films were interpreted separately by the same observer using the same rating scale. The following rating scale was used: A; definitely no lesion, B; probably no lesion, C; not sure, D; probably a lesion, and E; definitely a lesion. In analysis, for each observer the diagnostic results in terms of true positive (TP) and false positive (FP) decisions were plotted on a graph. The lowest point on the graph represents the TP and FP when only decisions designated as E according to the rating scale are included. The next point shows the TP and FP values when diagnoses designated as D are added and so forth. By connecting such plot points, a receiver operating characteristic (ROC) curves is obtained. The area under the curve represents the diagnostic accuracy resulting from a diagnostic performance at pure chance level and a value of 1.0 at perfect performance. This method has been known as an useful method to detect the minute difference for each radiographic technic, each observer and for the different lesion depths.

  • PDF

Paper Electrophoretic Separation of Some Long-Lived Fission Products (여과지전기영동법(濾過紙電氣泳動法)에 의한 장수명(長壽命) 핵분열(核分裂) 생성물분리(生成物分離))

  • Lee, Byung-Hun;Lee, Jong-Du
    • Journal of Radiation Protection and Research
    • /
    • v.8 no.2
    • /
    • pp.15-35
    • /
    • 1983
  • High voltage paper-electrophoresis of fission products from 24 hour neutron-irradiated and 150 days-decayed 90% highly enriched uranyl nitrate solution has been carried out by using the specially designed migration apparatus. The separation of Zr-95 and Nb-95 from the other fission products is possible under the migration condition of 0.1 $M-HClO_4$ (pH=0.85), 0.05 M-HCl+0.09M-KCl (pH=0.9), 0.1M-HCl (pH=1.1) and 0.01 M-HCl (pH=2.0). Zr-95 and Nb-95 are separated out at+1cm from the fiducial point. The separation of Zr-95 and Nb-95 from each other is possible under the migration condition of 0.1 $M-HClO_4$, 0.05 M-HCl+0.09 M-KCl, 0.1 M-HCl and 0.1 M-HAc+0.1 M-NaAc (pH=4.68) together with 2% ammonium oxalate. Nb-95 is separated out at $-6{\sim}-7cm$ from the fiducial point and Zr-95 at $+1{\sim}-lcm$. The separation of Ru-103 from the other fission products is possible under the migration condition of 0.025 $M-Na_2CO_3+0.025\;M-NaHCO_3$ (pH=10.0), 0.01M-$Na_3PO_4$ (pH=11.7) and 0.1 M-NaOH (pH=13.2). Ru-103 migrates towards the anode -6cm, -4cm and -3cm, respectively.

  • PDF