• Title/Summary/Keyword: Abutments

Search Result 423, Processing Time 0.021 seconds

A Study on Provenance of the Stone Relics of WoljungGyo Bridge built in Silla Kingdom based on Geological Properties (신라시대 교량 월정교에 사용된 석재 유구의 지질공학적 특성에 근거한 산지 추정 연구)

  • Lee, Kwnag-wu;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.4
    • /
    • pp.79-88
    • /
    • 2016
  • A derelict bridge called WoljungGyo is being restored in Gyeongju, the capital city of ancient Silla. WoljungGyo was originally built in 760AD, and later rebuilt in 1280AD during the Goryeo Kingdom. The bridge lasted in working condition for at least 520 years. The bridge was uncovered to the remains of both abutments and four piers, with only one or two steps remaining. The provenance of the WoljungGyo stone relics was investigated to decide the type of stone for the restoration works. Field survey were carried out in the whole area of Gyeongju-Si with petrological investigation for the stone relics. Results of the study present that Namsan granite was used in those days for building of the WoljungGyo. It is seems that the used stones were obtained from tor or core stone around the Tongil-jeon and Tap-gok area in the east side of Mt. Namsan.

THE ACCURACY ACCORDING TO THE VARIOUS DOWEL PINS OF WORKING CAST WITH REMOVABLE DIES (가철성 다이를 가진 작업모형에서 다우엘 핀의 종류에 따른 정확도에 관한 연구)

  • Lim, Ju-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.373-384
    • /
    • 1997
  • In this study, 4 types of dowel pin were used to fabricate removable dies using the Pindex system. The comparison of interabutment distances between before and after sawing were conducted in each type of dowel pin, and the horizontal discrepancies in the interabutment distance according to the abutment location and the type of dowel pin were comparatively analyzed. Abutments LM(left molar), LP(left premolar), A(anterior), RP(right premolar), and RM (right molar) were used for measurement. The interabutment distances were measured between each abutment : LM-LP, LM-A, LM-RP, and LM-RM. The slide scanned image of each model was magnified on the computer screen and the measurements were conducted using the meeting point of the cross on the occlusal surface of each abutment. The results were as follows : 1. In the comparison of interabutment distances between before and after sawing in each type of dowel pin, there was no significant difference in World dowel pin(double), Bi-pin(double), Maxcel dowel pin(single). In the World dowel pin(single) there was no significant difference between LM-LPs, but in the other measurements (LM-As, LM-RPs, and LM-RMs) there was significant difference between before and after sawing(p<0.05). 2. In comparison of horizontal discrepancies of the measurement according to the abutment location, there was significant difference between measurement LM-LP($0.27{\pm}0.19mm$) and the others : LM-A($0.46{\pm}0.20mm$), LM-RP($0.38{\pm}0.25mm$), LM-RM($0.45{\pm}0.22mm$) (p<0.05). 3. In comparison of horizontal discrepancies of the measurement according to the type of dowel, there was no significant difference between each dowel. As a result when fabricating a removable die using the previously mentioned 4 types of dowel pins, it is thought that the horizontal discrepancy increased in proportion to the interabutment span length and does not depend on the type of dowel pin.

  • PDF

THE EFFECT OF SCREW HOLE SEALING METHOD ON ABUTMENT SCREW LOOSENING IN DENIAL IMPLANT (임플랜트 보철물의 나사구멍 봉쇄방법이 지대나사 풀림에 미치는 영향에 관한 연구)

  • Lim, Jae-Bin;Yim, Soon-Ho;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.767-780
    • /
    • 1997
  • One of the most common problems of implant prosthesis is the screw loosening of abutment screws. This brings on discomfort in mastication, inflammation in the peri-implant tissue due to poor oral hygiene and fracture of prosthesis or loss of osseointegration. To prevent screw loosening, appropriate implantation to direct the occlusal force to the long axis of the implant, accurate design of the superstructure, decrease of the occlusal table, and adequate torque on the abutment screw are necessary. In this study the screw loosening torque was evaluated in implants with dimples or flutes in the internal surface of abutment screw holes. The abutments were fastened with slot type and hexagonal type abutment screws and were sealed with vinyl poly siloxane impression and bite registration material respectively. The screw loosening torque was evaluated after 1,800 and 12,600 times loading under a loading machine. The results were as follows. 1. The flute form group showed significantly higher loosening torque compared to the dimple form group and the group with no inner surface treatment (p<0.05). 2. There was no statistical difference in loosening torque according to the sealing materials. 3. The loosening torque according to the types of abutment screw showed no significant difference. 4. The loosening torque was significantly higher after 1800 times loading compared to 12600 times loading(p<0.05). From the above results. it is thought that formation of a flute in the internal surface of the screw hole decreases the chance of screw loosening, but the sealing materials and types of abutment screw did not show significant difference in prevention of screw loosening.

  • PDF

A STUDY OF THE STRESS DISTRIBUTION ACCORDING TO THE SLOPES OF THE CHIDING PLANES OF THE ABUTMENTS (지대치 유도면의 기울기에 따른 응력 분포에 대한 연구)

  • Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.293-301
    • /
    • 1998
  • The purpose of this study was to investigate the effects of load on root that was applied to edentulous area in three simulated situation, in each case the guiding planes of abutment were right vertical, 95 degrees, or 100 degrees to residual ridge. The 2-dimensional finite element method was used and the finite element model was prepared as fellows. Right mandibular 1st and 2nd molar was lost and the 2nd premolar with distal rest was used as primary abutment which had three different degrees of guiding plane. Then 150N of compressive force was applied to central fossae of the 1st and 2nd molars and von Mises stress and displacement was measured. The results were as follows; 1. Irrespective of slopes of guiding planes, the stress was concentrated on mesial side of root apex and distal side of coronal portion of root, in particular on junction with distal alveolar bone. As slopes of guiding planes were increased. stress on root and compact bone surrounding abutment was increased but no considerable effect was seen on compact bone of residual ridge. 2. Distal side of coronal portion of root limited by periodontal ligament was displaced distally and mesial side of apical portion was mesially. With slope of guiding plane increasing, the pattern of displacement was similar with one another but the quantity was increased. 3. Both abutment & alveolar bone were displaced downward and root of abutment, especially distal side of coronal portion, was displaced severely. As the guiding plane was tiffed more mesially over $90^{\circ}$, the degree of displacement was also increased.

  • PDF

An Experimental Study on Local Scour around Abutment (교대주변의 국부세굴에 관한 실험적 연구)

  • An, Sang-Jin;Hwang, Bo-Yeon
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.3
    • /
    • pp.255-263
    • /
    • 1999
  • The laboratory datas are for local scour depth measurement at vertical-wall abutment. These include the data to demonstrate the effects of local scour depth of abutment nose shape, alignment angle, flow depth and flume slope. The pattern of local scour were measured and analyzed the abutments which are rectangular, sharp, chamfered rectangular and ablong nose shapes. The experiments were carried out with varing the flume slope and alignment algle increasing flow depth every step in 1cm for four abutment types on the live-bed scour conditions. The flume slope and alignment angle were varied in five cases : for latter 30 $^{\circ}$, 60 $^{\circ}$, 90 $^{\circ}$, 120 $^{\circ}$ and 150 $^{\circ}$, for former 0.01%, 0.03%, 0.05%, 0.1% and 0.2%. The maximum scour depths were analyzed for the shaped of abutment nose with rectangular, ablong, chamfered rectangular and sharp in order. The results of the experiments show that the scour depth varies not only with abutment nose shapes and alignment angle but also with the flow depth and flume slope.

  • PDF

A Study on the Lateral Movement of Bridge Abutment Using Centrifuge Test and Numerical Analysis (원심모형시험과 수치해석을 이용한 교대 측방유동에 관한 연구)

  • Yoo, Wan-Kyu;Kim, Ki-Il;Kim, Byoung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1799-1804
    • /
    • 2010
  • In regard to fill loading structures such as bridge abutments and retaining walls on soft ground, the soft ground undergoes excessive deformation, which causes the lateral movement of the ground, resulting in increased risk of much damage. In this study, a centrifuge model test was conducted to check the possibility of lateral movement of a bridge abutment during back filling in a field, and a numerical analysis considering the lateral movement of the bridge abutment under the influence of the counterweight fill method applied during construction was carried out by using MIDAS/GTS as the FEM(Finite Element Method) program. The results of this study showed that the lateral movement of the abutment can exceed the allowable lateral movement value(15mm), and that the counterweight fill method was effective for the stability of the lateral movement.

A Study on the Design Method of the Reinforced Earth Structures Considering Compaction Induced Stresses (다짐 유발응력을 고려한 보강토 설계방법에 관한 연구)

  • 임철웅;백영식
    • Geotechnical Engineering
    • /
    • v.8 no.4
    • /
    • pp.5-16
    • /
    • 1992
  • The main purpose of this the sutdy is to develop the reinforced earth structure design method considering induced stresses and deflections resulting from placement and compaction of soil. In this paper, the new reinforcement Geolog developed by the author is also introduced which is being used as one of the effective earth reinforcing structure against compaction induced stresses. This study adopted the Seed's bilinear model in the estimation of the com paction induced stresses and compute the peak lateral stresses during compaction by doubled Boussinessq's elastic solution of mirror image theory, thereafter, calculate the residual compaction induced lateral stresses from the above peak lateral stress by the residual fraction. It is considered to be reasonable that the compaction induced stresses be added to the lateral earth pressures estimated from conventional gravity analysis considering the actual stresses during service life of the structures. "GEOLOG", a composite of steel bar and attached concrete stopper is found to be effective against tension and pull - out failure. In this paper, the design method considering the compaction induced stresses and the effect of Geolog reinforcement is suggested for the remforced earth structures where backkfill settlement on displacements are not allowed as in the cases of the bridge abutments or double faced reinforcement earth structures.tructures.

  • PDF

Histomorphometric analysis of an immediate non-functional loaded implant in dogs

  • Ha, Jeong-Wan;Kim, Su-Gwan;Kim, Hak-Hyun;Moon, Seong-Yong;Lim, Sung-Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.1
    • /
    • pp.90-94
    • /
    • 2008
  • The purpose of this study was to investigate the effects of immediate non-functional loading by analyzing histomorphology around the implant tissues in dogs. Five eight- to nine-month-old full-grown dogs weighing around 12 kg were used in the study. Group I (control group) comprised those in which delayed loading was applied to the right side of the mandible, and Group II (experimental group) consisted of dogs in which immediate loading was performed on the left side of the mandible. Resorbable blast media (RBM)-treated double-threaded US III implants measuring 3.5 mm in diameter and 11 mm long were used in the study. Each animal received four implants in each group, for a total of 40 implants. Cemented type abutments were used after implantation. An 8-week period was allowed for bone healing and an abutment was placed after exposing the periosteum for loading. An implant sample was obtained from bone blocks taken when the dogs were killed at 16 weeks after loading. A Mann-Whitney U-test was performed to evaluate statistical significance. Student's t-test was used for the histological evaluation. The bone formation ratio in Groups 1 and 2 was 88.23 and 86.41%, respectively. No significant difference in new bone formation was observed in the two groups. As no significant difference was seen in new bone formation between the delayed and immediate loading groups, early loading might be possible after implant placement.

INFLUENCE OF INDIVIDUAL TOOTH TRAY ON THE TEETH WITH UNDERCUT IN IMPRESSION TAKING (언더컷이 있는 치아에서 개별 치아 트레이가 인상채득에 미치는 영향)

  • Seo Kowang-Won;Shin Sang-Wan;Lee Jeong-Yeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.11-20
    • /
    • 2004
  • Problem : The several studies were reported to the effects of individual tooth tray with the parallel tooth, but not reported to the effect of individual tooth tray with severe undercut in impression making. Purpose : The purpose of this study is to examine the effect of individual tooth tray; 1) the accuracy of impression in terms of distance. 2) reproducibility of pocket. Material and methods : In this study, a metal model with 3 teeth including tooth prepared 30-degree undercut and gingival crevice of the depth 5mm, width 0.4mm was cast. Impressions of the metal model were taken in 5 times used 4 kinds of impression materials with individual tooth tray and another impression taking were made with conventional method without individual tooth, used same materials, procedure. The stone models were made. Distances between abutments were measured with a Micromeasurescoup-mm. Result : The following results were obtained ; 1. In the comparisonof inter-abutment distance between parallel tooth without individual tooth tray, 4elastomeric materials have not significant difference to the metal model(p>0.05). 2. In the comparisonof inter-abutment distance with undercut tooth without individual tooth tray, 4elastomeric materials have a significant difference to the metal model(p<0.05), especially polyether's dimensional change is large. 3. If individual tooth tray was used to take impression in abutment teeth with severe undercut, more stable results was achieved easily than conventional method. (p>0.05). 4. It is not true that the pressure of impression material with individual tooth tray increased to gingival sulcus. Conclusion : By the results, I knew the fact that individual tooth tray was useful impression method on the teeth with severe undercut for the dimensional stability. Also, I could not confirm the fact that individual tooth tray would increase the penetrating pressure into cervice.

Peri-implant bone length changes and survival rates of implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height

  • Kim, Hae-Young;Yang, Jin-Yong;Chung, Bo-Yoon;Kim, Jeong Chan;Yeo, In-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.2
    • /
    • pp.58-63
    • /
    • 2013
  • Purpose: The aim of this study was to measure the peri-implant bone length surrounding implants that penetrate the sinus membrane at the posterior maxilla and to evaluate the survival rate of these implants. Methods: Treatment records and orthopantomographs of 39 patients were reviewed and analyzed. The patients had partial edentulism at the posterior maxilla and limited vertical bone height below the maxillary sinus. Implants were inserted into the posterior maxilla, penetrating the sinus membrane. Four months after implant insertion, provisional resin restorations were temporarily cemented to the abutments and used for one month. Then, a final impression was taken at the abutment level, and final cement-retained restorations were delivered with mutually protected occlusion. The complications from the implant surgery were examined, the number of failed implants was counted, and the survival rate was calculated. The periimplant bone lengths were measured using radiographs. The changes in initial and final peri-implant bone lengths were statistically analyzed. Results: Nasal bleeding occurred after implant surgery in three patients. No other complications were found. There were no failures of the investigated implants, resulting in a survival rate of 100%. Significantly more bone gain around the implants (estimated difference=-0.6 mm, P=0.025) occurred when the initial residual bone height was less than 5 mm compared to the >5 mm groups. No significant change in peri-implant bone length was detected when the initial residual bone height was 5 mm or larger. Conclusions: This study suggests that implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height may be safe and functional.