• Title/Summary/Keyword: Absorption power

Search Result 849, Processing Time 0.027 seconds

ChlorophyII and suspended sediment specific absorption coefficient in the sea.

  • Ahn, Yu-Hwan;Moon, Jeong-Eon
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.399-403
    • /
    • 1998
  • Absorption coefficient per mass unit of particles, specific absorption coefficient, is one of main parameters in developing algorithms for ocean color remote sensing. Specific absorption coefficient of chlorophyll (a$^*_{ph}$) and suspended sediment (SS) were analyzed by "wet filter technique" and "Kishino method" for data sets observed in the Yellow and Mediterranean Seas. A new data-recovering method for the filter technique was also developed using spectrum slopes. This method recovered the baseline of spectrum that was often missed in the Kishino method. High a$^*_{ph}$($\lambda$) values in the oligotrophic Mediterranean Sea and low values in the Yellow Sea were observed, spanning over the range of 0.02 to 0.12 $m^2$/mg, at the chlorophyll maximum absorption wavelength 440nm. The empirical relationship between a$^*_{ph}$ and chlorophyll concentration was found to fit a power function, which was slightly different from that proposed by Bricaud et ai. (1995). Absorption specific coefficients for suspended sediment (a$^*_{SS}$) didn't show any relationship with concentrations of suspended sediment. However, the average value of a$^*_{SS}$ at 440nm was close to the specific absorption coefficient of soil (loess) measured by Ahn (1990). The more-pronounced variability of a$^*_{SS}$ than a$^*_{ph}$ perhaps can explain more wide range of size-distribution for SS, which were determined by their specific gravity and agitation of water mass in the sea surface.

  • PDF

Performance Prediction & Analysis of MGT Co-generation System

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu;Kim, Jae-Hoon
    • New & Renewable Energy
    • /
    • v.2 no.3
    • /
    • pp.15-22
    • /
    • 2006
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new market penetration using the distributed generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection standards. KEPCO, a government company in Korea, has performed the project to identify and evaluate the performance of Micro Gas Turbine(MGT) technologies focused on 30, 60kW-class grid-connected optimization and combined Heat & Power performance. This paper describes the results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of Exhaust-gas Absorption Chiller was developed, so that it will be able to analyze or propose new distributed generation system using MGT. In addition, KEPCO carried out the field testing of the MGT Cogeneration system at the R&D Center Building, KEPCO. The field test was conducted in order to respond to a wide variety of needs for heat recovery and utilization. The suggested method and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

Numerical studied on consequenses of the ion pumping effect in helicon plasmas (헬리콘 플라즈마에서 이온 펌핑 효과의 영향에 대한 수치적 해석 연구)

  • 조수원;박인호;최성을;권명회
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.3B
    • /
    • pp.353-360
    • /
    • 1999
  • The global balance model is applied to investigate the transient behavior of the electron density and temperature in helicon plasmas. The power absorption calculated from the solutions of the Maxwell equations is used in solving the power balance equation. A balance model for the neutral gas is also considered to fins its density self-consistently. It is turned out that the numerical results reasonably explain consequences of the ion pumping effect including the occurrence of two distinct modes of pulsed helicon discharge which have been observed experimentally. The behavior of the discharge parameters are fond to be primarily dependent on the power absorption and the gas flow rate, but the pressure controls the electron density and temperature of the final steady state as well as the transient state even with the same flow rate. Finally, it is shown that the electron density virtually the linear relationship between the density and the magnetic field is retained for a higher pressure when the effect of the ion pumping is negligible.

  • PDF

The Mortar Properties of Portland Cements Blended with Modified Coal Ashes (가공된 석탄재를 사용한 석탄재혼합시멘트의 모르터 특성)

  • 홍원표;노재성;조헌영;정수영;김무한
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.7
    • /
    • pp.833-840
    • /
    • 1990
  • For the development of multi-functional materials which has water reducing power, air entraining power and waterproofing power as well as blending additive in cement mortar the coal ash was modified with asphalt-stearic acid or asphalt-boiled oil mixtures by mechanical treatment. And the physical properties of cement mortar blended with modified coal ashes were compared with those of the water-tightness-cement mortar and the ordinary-portland-cement mortar added with AE.water reducing agent. The mortar of coalash-blend-cement modified with asphalt-stearic mixture was increased acid about 20% in initial strengths and decreased about 20% in water absorption ratio than those of ordinary coalash-blend-cement. The mortar of coalash-blend-cement modified with asphalt-bolied oil mixture was similar to the cement mortar added with AE.water reducing agent in water reduction ratio, air entraining conents and the initial strengths, also was similar to the water-tightness-cement mortar in water absorption and water permeability ratios.

  • PDF

Performance Test of MGT Combined Heat & Power System (마이크로 가스터빈 열병합 발전시스템 성능평가)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.313-316
    • /
    • 2006
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. Korea Electric Power Corporation (KEPCO) has researched performance characteristics of the 60k W class 1) basic start-up & shutdown operation analysis 2) interconnection test 3) MGT -absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

The Characteristics of Ductile Cast Iron Heat-treated by $CO_2$Laser (구상흑연주철의 $CO_2$레이저 표면경화 특성)

  • 정원기;전병철;김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.998-1002
    • /
    • 1997
  • This study has been performed to predict beam absorption with analysis of temperature field by using a FEM in co /sab 2/ laser hardening and to invesrigate into some effects of power density and travel speed of laser beam on the microstructure and hardness of ductile cast iron treated by laser surface hardening technique. Optical micrograph has shown that large martensite and small amount of retained austenite appear in inside hardened zone. Hardness measurement has revealed that the range of maximum hardness value is Hv=415 .+-. 10. The power density increases and the travel speed decreases, the depth of hardened zone increases due to increase of input power density.

  • PDF

A Study on the Heat Transfer in boiler through the performance test in thermal power plant (화력발전소 보일러내의 열전달에 관한 연구)

  • Kwon, Y.S.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2064-2069
    • /
    • 2004
  • The main reason to analyze heat transfer in boiler inside through the performance test in fossil power plant is to increase plant high efficiency and energy saving movement in the government. Tins study intends to have trend and analyze the boiler heat transfer through the performance test, so it may give us the heat distribution in boiler inside in super-critical and sub-critica1 pressure type power plant

  • PDF

A study on the characteristics of high frequency road noise transmission at the rear seat of a hatch back compact car using PBNR (Power Based Noise Reduction) method (파워기반 소음감소 기법을 이용한 준중형 해치백 후석 고주파성 로드노이즈 전달특성 연구)

  • Lee, Jonghyun;Cho, Sehyun;Yi, Juwan;Lee, Chulhyun;Yang, Jungmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.248-255
    • /
    • 2018
  • It is known that the road noise on the rear seat of a hatchback type car is worse than that of a sedan type car because of the weakness on sealing structure. Therefore, a sound sealing system and sufficient absorption/insulation performance are required. In the case of a compact segment car, however, the application of the sufficient absorption and insulation materials is limited, because of the restriction on the production cost and weight of the car. In this study, we estimate the noise transmission path on the vehicle's body structure from tires and ground using the PBNR (Power Based Noise Reduction) method which is useful in quantitative measurement. Based on these results, we suggest an alternative absorption/insulation method for the better performance of rear seat road noise reduction in a compact hatchback car.

Effect of the Exhaust Heat from Micro Gas Turbine on the Performance Characteristics of the Absorption Chiller (마이크로가스터빈 배열부하가 배가스흡수식 냉온수기의 성능에 미치는 영향)

  • Choi Kyoung-Shik;Sohn Wha-Seung;Kim HyoungSik;Rhim Sang-Kyu;Hur Kwang-Beom
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.158-162
    • /
    • 2006
  • Micro gas turbine (MGT) has received attention recently as a small-scale distributed power source. Due to many advantages such as their small size, low maintenance cost and minimal vibrations during operation, they are expected to become widespread in a wide range of applications. The exhaust heat emitted by the MGT is in the form of an exhaust gas that is about $270^{\circ}C$ which is an extremely clean gas. Korea Gas Corporation (KOGAS) has researched performance characteristics of a cogeneration system combining 28kW class MGT and 13 USRT class absorption hot and chilled water generator in the local condition. The present results of this study can be summarized as follows: (1) in heating mode, the total efficiency of cogen. system is about $65\%$ and heating capacity is 33kW at 25kW MGP power (2) in cooling mode, COP is about 0.6 at 22kW MGT power.

Comparison of Carbon Dioxide Absorption in Aqueous MEA, DEA, TEA, and AMP Solutions

  • Kim, Young Eun;Lim, Jin Ah;Jeong, Soon Kwan;Yoon, Yeo Il;Bae, Shin Tae;Nam, Sung Chan
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.783-787
    • /
    • 2013
  • The separation and capture process of carbon dioxide from power plants is garnering interest as a method to reduce greenhouse gas emissions. In this study, aqueous alkanolamine solutions were studied as absorbents for $CO_2$ capture. The solubility of $CO_2$ in aqueous alkanolamine solutions was investigated with a continuous stirred reactor at 313, 333 and 353 K. Also, the heat of absorption ($-{\Delta}H_{abs}$) between the absorbent and $CO_2$ molecules was measured with a differential reaction calorimeter (DRC) at 298 K. The solubility and heat of absorption were determined at slightly higher than atmospheric pressure. The enthalpies of $CO_2$ absorption in monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA), and 2-amino-2-methyl-1-propanol (AMP) were 88.91, 70.44, 44.72, and 63.95, respectively. This investigation showed that the heat of absorption is directly related to the quantity of heat for absorbent regeneration, and is dependent on amine type and $CO_2$ loading.