• Title/Summary/Keyword: Ablation treatment

Search Result 245, Processing Time 0.028 seconds

Treatment of glabellar frown lines using selective nerve block with radiofrequency ablation (고주파절제술을 통한 선택적 신경차단법을 이용한 미간주름의 개선)

  • Hwang, Yong Seok;Kim, Young Seok;Roh, Tai Suk;Tark, Kwan Chul;Lee, Kun Chang
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.205-210
    • /
    • 2009
  • Purpose: Corrugator supercilii muscle pulls eyebrow to inferomedial direction and produces the vertical component of the glabellar line formation. Current techniques for eliminating of glabellar frown include direct resection of corrugators and botulinum toxin injection. Muscle resection in endoscopic face lift procedure is relatively complex and has many disadvantages ranging from possible nerve injury, postoperative edema, pain and a long recovery period. The Botox treatment on the other hand is much more simple in technique but has a short duration of action. The authors have attempted new ways of finding improved treatment of the glabellar frown by selectively blocking of motor nerves innervating the corrugator supercili muscle by using radiofrequency ablation technique. Methods: A total of 80 patients were recruited in our study during the period between Feb. 2007 to June 2008. A probe was introduced from the supraorbital ridge and advanced to the corrugator supercilii muscle. Nerve stimulator was then used to locate the nerve innervating the corrugator and radiofrequency ablation of the nerve was done. Results: In all patients, there were marked improvement in glabellar frown after treatment. There were no reported cases of any relapses during the follow up period. No complication was noted such as facial nerve injury. No patient complained of any adverse symptoms other than slight discomfort due to swelling of the operation site. Conclusion: The treatment of glabellar frown lines using selective nerve block with radiofrequency ablation was not only less invasive but also excellent in surgical outcomes.

Nonpharmacological treatment of arrhythmia (소아 부정맥의 비약물적 치료)

  • Bae, Eun-Jung
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.9
    • /
    • pp.930-936
    • /
    • 2006
  • Although antiarrhythmic medication has been the main treatment modality for arrhythmia in children, in recent decades technological development and computerization have made great advances in nonpharmacological therapy. This article reviews the transcatheter radiofrequency ablation for tachycardia in children, recent advances of device therapy for bradycardia, antitachycardia pacing, implantable cardioverter defibrillator. As a new field of device therapy, cardiac resynchronization therapy for congestive heart failure is also mentioned.

Ablation Characteristics of Bovine Liver According to Cool-Tip Temperature of RFA Equipment (고주파 열치료 장비의 Cool-Tip 온도에 따른 소간의 소작 특성)

  • Choi, Young-Jae;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.155-161
    • /
    • 2015
  • This study confirmed the correlation between the change of the cooling water in internal cooling system and the size of the ablation site of bovine liver in RF heat treatment equipment. The bovine liver was resection with $4{\times}4{\times}4cm^3$ in 2cm cool-tip and with $6{\times}6{\times}6cm^3$ in 3cm cool-tip for the experiments. Area and perimeter of the ablation site for bovine liver were measured by Freehand techniques of MRI. It showed area and perimeter decreased during cool-tip temperature rises 6 and 12 minutes ablation using a 2cm and 3cm cool-tip. The correlation of cool-tip temperature and area and perimeter was statistically significant the result are shown(p=.000). The measurements of area and perimeter were more accurate with MRI in actual measurements and MRI for ablation range. The statistical results using Paired sample T-test was also significant(p=.038). The ablation range of bovine liver decreased according as cooling water temperature increases in RF heat treatment equipment for reason of carbonization occurred due to does not accurately pass the RF energy. Therefore, it is considered the effect of RF heat treatment would be increased if the temperature of the cooling water consistently maintain the low temperature in order to reduce the generation of carbide at RF heat treatment and RF energy is delivered accurately.

Radiofrequency catheter ablation of atrioventricular nodal reentry tachycardia in children and adolescents: a single center experience

  • Hyun, Myung Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.12
    • /
    • pp.390-394
    • /
    • 2017
  • Purpose: Atrioventricular nodal reentry tachycardia (AVNRT) is less common in pediatric patients than in adult patients. Thus, data for pediatric AVNRT patients are insufficient. Hence, we aimed to analyze the patient characteristics, treatment, and any recurrences in pediatric AVNRT patients. Methods: We reviewed the records of 50 pediatric AVNRT patients who had undergone radiofrequency catheter ablation (RFCA) between January 1998 and December 2016 at a single regional center. The patients were aged ${\leq}18years$. Results: Among 190 pediatric patients who underwent RFCA for tachyarrhythmia, 50 (26.3%; mean age, $13.4{\pm}2.6years$) were diagnosed as having AVNRT by electrophysiological study. Twenty-five patients (25 of 50, 50%) were male. Twenty patients (20 of 50, 40%) used beta-blockers before RFCA. All patients had no structural heart disease except 1 patient with valvular aortic stenosis and coarctation of the aorta. RFCA was performed using the anatomic approach under fluoroscopic guidance. The most common successfully ablated region was the midseptal region (25 of 50, 50%). Slow pathway (SP) ablation and SP modulation were performed in 43 and 6 patients, respectively. Complication occurred in 1 patient with complete atrioventricular block. During follow-up, 6 patients had recurrence of supraventricular tachycardia, as confirmed by electrocardiography. Among them, 5 underwent successful ablation at the first procedure. In 1 patient, induction failed during the first procedure. Conclusion: RFCA is safe and effective in pediatric AVNRT patients. However, further research is needed for establishing the endpoints of ablation in pediatric AVNRT patients and for identifying risk factors by evaluating data on AVNRT recurrence after RFCA.

Radiofrequency Ablation and Excision of Multiple Cutaneous Lesions in Neurofibromatosis Type 1

  • Kim, Seong-Hun;Roh, Si-Gyun;Lee, Nae-Ho;Yang, Kyung-Moo
    • Archives of Plastic Surgery
    • /
    • v.40 no.1
    • /
    • pp.57-61
    • /
    • 2013
  • Background Von Recklinghausen disease or neurofibromatosis type 1 is an autosomal dominant genetic disorder of chromosome 17q11.2. The most common characteristic findings of NF 1 include multiple and recurrent cutaneous neurofibromas associated with psychosocial distress. Methods Sixteen patients (9 female, 7 male; average age, 31 years; range, 16 to 67 years) with multiple cutaneous neurofibromas between March 2010 and February 2012 were included in the study. All patients were treated with radiosurgical ablation and excision under general anesthesia. Results All 16 patients were satisfied with the results, when questioned directly during the outpatient department follow-up. The only complaint from a few patients was minimal scarring, but acceptable results were obtained in the end. Conclusions The radiofrequency procedure is almost bloodless and quick, creating a smaller necrotizing zone. Therefore, instead of employing the time consuming traditional surgery, such as laser therapy and electrosurgical excision, that produces uncertain results and can affect normal adjacent tissue, treatment of neurofibromas with radiofrequency ablation and excision can be an alternative choice of treatment for patients with a large number of neurofibromas.

Cooled radiofrequency ablation of genicular nerves for knee osteoarthritis

  • Myong-Hwan Karm;Hyun-Jung Kwon;Chan-Sik Kim;Doo-Hwan Kim;Jin-Woo Shin;Seong-Soo Choi
    • The Korean Journal of Pain
    • /
    • v.37 no.1
    • /
    • pp.13-25
    • /
    • 2024
  • Knee osteoarthritis (OA) is a prevalent and debilitating musculoskeletal condition that significantly affects the quality of life of millions of individuals worldwide. In recent years, cooled radiofrequency ablation (CRFA) has become a viable treatment option for knee OA. This review thoroughly evaluated the existing literature on CRFA therapy for knee OA. It delved into the mechanisms behind CRFA, evaluated its clinical efficacy, and investigated potential avenues for future research and application. The insights gained from this review are crucial for healthcare professionals, researchers, and policymakers, offering an updated perspective on CRFA's role as a viable therapeutic option for knee OA.

Relation between Ablation Execution Time and Radiation Exposure Effect in the Treatment of Atrial-fibrillation using Cryo-balloon and 3D Radio-frequency Ablation (냉각 풍선 절제술과 3D 고주파 절제술을 이용한 심방세동 치료 시 절제술 시행 시간과 방사선 피폭 영향과의 연관성)

  • Seo, Young-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.427-434
    • /
    • 2022
  • Atrial fibrillation treatment includes 3D RFCA and Cryo-balloon ablation. Both procedures have in common that they enter after understanding the structure of the heart using angiography equipment. Therefore, there is a disadvantage that the effect of exposure according to the procedure time can be a threat to both the patient and the operator, so this study aims to confirm the relationship between the total ablation time and the effect of radiation exposure. We used follow-up data (retrospective) from 41 patients who underwent coronary angiography and arrhythmia at the same time from March 2019 to July 2022. The range for total ablation time was based on the recorded data from the start to the end of the total ablation. The end point of 3D RFCA was when the ablation was completed for 4 pulmonary veins, and in the case of Cryo-balloon ablation, the data that succeeded in electrical insulation were included. As a result of analyzing the total ablation time, the time taken for Cryo-balloon ablation was 1037.29±103.66 s, which was 2448.61 s faster than 3D RFCA using 3485.9±405.71 s, and was statistically significant. (p<0.05) As a result of analyzing the total fluoroscopy time, the exposure time for 3D RFCA was 2573.75±239.08 s, which was less by 1717.15 s than the exposure time for Cryo-balloon ablation, 4290.9±420.42 s, and was statistically significant. In the case of total area dose product, 3D RFCA was 59.04±13.1 uGy/m2, which was lower than Cryo-balloon ablation 980.6±658.07 uGy/m2 by 921.56 uGy/m2, which was statistically significant. As the insulation time of the Cryo-balloon ablation is shorter than that of the 3D RFCA, the method using the Cryo-balloon ablation is considered to be effective when the patient's condition is not good and a quick procedure is required. However, in patients with permanent Atrial fibrillation, there is a high probability of structural changes in the heart, so it is considered that 3D RFCA is better than Cryo-balloon ablation, which is difficult to manipulate.

Role of radiofrequency ablation in advanced malignant hilar biliary obstruction

  • Mamoru Takenaka;Tae Hoon Lee
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.155-163
    • /
    • 2023
  • Malignant hilar biliary obstruction (MHO), an aggressive perihilar biliary obstruction caused by cholangiocarcinoma, gallbladder cancer, or other metastatic malignancies, has a poor prognosis. Surgical resection is the only curative treatment for biliary malignancies. However, the majority of patients with MHO cannot undergo surgery on presentation because of an advanced inoperable state or a poor performance state due to old age or comorbid diseases. Therefore, palliative biliary drainage is mandatory to improve symptomatic jaundice and the quality of life. Among the drainage methods, endoscopic biliary drainage is the current standard for palliation of unresectable advanced MHO. In addition, combined with endoscopic drainage, additional local ablation therapies, such as photodynamic therapy or radiofrequency ablation (RFA), have been introduced to prolong stent patency and survival. Currently, RFA is commonly used as palliative therapy, even for advanced MHO. This literature review summarizes recent studies on RFA for advanced MHO.