• 제목/요약/키워드: Ab

검색결과 3,075건 처리시간 0.024초

정상 성인의 조음밸브에 대한 내${\cdot}$외전 비율 (Fast ab/adduction Rate of Articulation Valves in Normal Adults)

  • 박희준;한지연
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2007년도 한국음성과학회 공동학술대회 발표논문집
    • /
    • pp.149-151
    • /
    • 2007
  • This study was designed to investigate fast ab/adduction rate of articulation valves in normal adults. The measurement of fast ab/aduction rate has traditionally been used for assessment, diagnosis and therapy in patients who suffered from dysarthria, functional articulation disorders or apraxia of speech. Fast ab/adduction rate shows the documented structural and physiological changes in the central nervous system and the peripheral components of oral and speech production mechanism. Fast ab/adduction rates were obtained from 20 normal subjects by producing the repetition of vocal function (/ihi/), tongue function (/t${\wedge}$/), velopharyngeal function (/m/), and labial function (/p${\wedge}$/). The Aerophone II was used for data recording. The results of finding as follows: average fast ab/adduction rates were vocal function(6.21cps), tongue function(7.42cps), velopharyngeal function(5.23cps), labial function (6.93cps). The results of this study are guidelines of normal diadochokinetic rates. In addition, they can indicate the severity of diseases and evaluation of treatment.

  • PDF

Effects of Operational Parameters on the Removal of Acid Blue 25 Dye from Aqueous Solutions by Electrocoagulation

  • Balarak, Davoud;Ganji, Fatemeh;Choi, Suk Soon;Lee, Seung Mok;Shim, Moo Joon
    • 공업화학
    • /
    • 제30권6호
    • /
    • pp.742-748
    • /
    • 2019
  • Influence of several experimental parameters (e.g., initial dye concentration, pH, distance between electrodes, applied voltage, electrical conductivity, current density, and reaction time) on the performance of electrocoagulation (EC) process for the removal of acid blue 25 (AB25) was studied. A bipolar batch reactor was used to test the impact of the parameters. The removal efficiency (RE) of AB25 dye was promoted by increasing the contact time, voltage, electrical conductivity, and applied current density. In contrast, RE of AB25 decreased with higher level of AB25 and the longer distance between electrodes. The removal efficiency increased consistently until pH 7, but decreased above pH 7. The maximum efficiency of AB25 removal above 90% was obtained at a voltage of 60 V, reaction time of 90 min, distance between electrodes of 0.5 cm, initial concentration of 25 mg/L, conductivity of 3,000 μS/cm and pH of 7. These results imply that the high RE of AB25 dye from the aqueous solution can be achieved by EC process.

경주마(競走馬) 생산(生産)을 위한 혈액형(血液型) 연구(硏究) I. 혈청(血淸) Albumin형(型)에 대(對)하여 (Studies on blood types for the reproduction of racing horses 1. Analysis of serum albumin type)

  • 임영재;엄영호
    • 대한수의학회지
    • /
    • 제29권4호
    • /
    • pp.457-460
    • /
    • 1989
  • This work was carried out to get some informations about blood types and their researches, involved blood stock and genetic identification. Horses examined were total 55 heads of sire, mare and their progeny in Korean Horse Affairs Association. 1. Albumin phenotypes of 26 mare were examined. The appearance of phenotype AA, BB, AB, was 1, 18, 7 respectively. The gene frequency of albumin A was 0.17 and albumin B was 0.76. 2. The appearance of phenotype AA, BB, AB in 29 progeny was 1, 16, 12 respectively. The gene frequency of albumin A was 0.24 and albumin B was 0.76. The gene frequency of gene A was higher than their parents. 3. Identification of the relationship between parents and their progeny was also examined. 4 of type AB between AA & BB, 4 of type BB between BB & BB, 13 of type AB between BB & AB were borned. In third case, all of progeny was type AB. This results suggest positive relationship between them.

  • PDF

Waffle-Cone Technique Using Solitaire AB Stent

  • Park, Hye-Ran;Yoon, Seok-Mann;Shim, Jai-Joon;Kim, Sung-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권4호
    • /
    • pp.222-226
    • /
    • 2012
  • The waffle-cone technique is a modified stent application technique, which involves protrusion of the distal portion of a stent into an aneurysm fundus to provide neck support for subsequent coiling. The authors report two cases of wide necked basilar bifurcation aneurysms, which were not amenable to stent assisted coiling, that were treated using the waffle-cone technique with a Solitaire AB stent. A 58-year-old woman presented with severe headache. Brain CT showed subarachnoid hemorrhage and angiography demonstrated a ruptured giant basilar bifurcation aneurysm with broad neck, which was treated with a Solitaire AB stent and coils using the waffle-cone technique. The second case involved an 81-year-old man, who presented with dizziness caused by brain stem infarction. Angiography also demonstrated a large basilar bifurcation unruptured aneurysm with broad neck. Solitaire AB stent deployment using the waffle-cone technique, followed by coiling resulted in near complete obliteration of aneurysm. The waffle-cone technique with a Solitaire AB stent can be a useful alternative to conventional stent application when it is difficult to catheterize bilateral posterior cerebral arteries in patients with a wide-necked basilar bifurcation aneurysm.

Solitaire AB Stent-Assisted Coiling of Wide-Neck Micro Aneurysms

  • Li, Xue-dong;Qin, Jun;Xiao, Zhen-yong;Feng, Yi;Chen, Jia-kang
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권4호
    • /
    • pp.341-345
    • /
    • 2016
  • Objective : Solitaire AB stent-assisted coiling facilitates the endovascular treatment of wide-necked intracranial aneurysms. We present our experience of coiling the micro-aneurysms of wide-neck with Solitaire AB stent assisting in a single center. Methods : Thirty-one Solitaire AB stents were used to treat via endovascular approach patients with 31 wide-neck micro aneurysms in a single center in China. Technical and clinical complications were recorded. Modified Rankin Scale was used to evaluate the patients' conditions via clinic and telephone follow-up. Results : The mean width of aneurysm sac was $2.30{\pm}0.42mm$, and the mean diameter of aneurysm neck was $2.83{\pm}.48mm$. Complete occlusion was achieved in 28 aneurysms (90.32%); neck remnant was seen in 3 aneurysms (9.68%). Technical and clinical complications related to the procedure were encountered in four patients (12.5%). Two patients died (6.25%). No patient had a permanent deficit. Conclusion : Solitaire AB stent was a safe and efficiency tool in assisting coiling of micro aneurysms with wide neck, but may be not suitable for a blaster-like one. Mid- and long-term follow-up will be required to elucidate the impact of the Solitaire AB stent on recanalization rate.

Validation of the correlation-based aerosol model in the ISFRA sodium-cooled fast reactor safety analysis code

  • Yoon, Churl;Kim, Sung Il;Lee, Sung Jin;Kang, Seok Hun;Paik, Chan Y.
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.3966-3978
    • /
    • 2021
  • ISFRA (Integrated SFR Analysis Program for PSA) computer program has been developed for simulating the response of the PGSFR pool design with metal fuel during a severe accident. This paper describes validation of the ISFRA aerosol model against the Aerosol Behavior Code Validation and Evaluation (ABCOVE) experiments undertaken in 1980s for radionuclide transport within a SFR containment. ABCOVE AB5, AB6, and AB7 tests are simulated using the ISFRA aerosol model and the results are compared against the measured data as well as with the simulation results of the MELCOR severe accident code. It is revealed that the ISFRA prediction of single-component aerosols inside a vessel (AB5) is in good agreement with the experimental data as well as with the results of the aerosol model in MELCOR. Moreover, the ISFRA aerosol model can predict the "washout" phenomenon due to the interaction between two aerosol species (AB6) and two-component aerosols without strong mutual interference (AB7). Based on the theory review of the aerosol correlation technique, it is concluded that the ISFRA aerosol model can provide fast, stable calculations with reasonable accuracy for most of the cases unless the aerosol size distribution is strongly deformed from log-normal distribution.

Selective laser melting 방식으로 제작된 Inconel 718 합금의 수소취성에 미치는 응고셀 조직의 영향에 관한 연구 (A Study on the Effect of Solidification Substructure on the Hydrogen Embrittlement of Inconel 718 Fabricated by Selective Laser Melting)

  • 이동현
    • 열처리공학회지
    • /
    • 제35권4호
    • /
    • pp.203-210
    • /
    • 2022
  • In this study, hydrogen embrittlement in Inconel 718 fabricated by selective laser melting (SLM) was investigated. To focus on the effect of the SLM-induced solidification substructure, hydrogen embrittlement behavior of SLM as-built (SLM-AB) sample and that of conventionally produced (Con-S) sample were systematically compared. The detailed microstructural characterization showed that the SLM-AB sample exhibited a solidification substructure including a high density of dislocations and Laves phase, while the Con-S sample showed completely recrystallized grains without any substructure. Although the intrinsic strength in the SLM-AB sample was higher than the Con-S sample, the resistance to hydrogen embrittlement was higher in the SLM-AB sample. Nevertheless, a statistical analysis of the hydrogen-assisted cracks (HACs) revealed that the predominant HAC type of SLM-AB and Con-S samples was similar, i.e., intergranular HAC. The difference in the resistance to hydrogen embrittlement between the SLM-AB and Con-S samples were discussed in terms of the relation between the microstructural feature and its effect on hydrogen accumulation.

GK2A/AMI와 GK2B/GOCI-II 자료를 융합 활용한 주간 고해상도 안개 탐지 알고리즘 개발 (Development of High-Resolution Fog Detection Algorithm for Daytime by Fusing GK2A/AMI and GK2B/GOCI-II Data)

  • 유하영;서명석
    • 대한원격탐사학회지
    • /
    • 제39권6_3호
    • /
    • pp.1779-1790
    • /
    • 2023
  • 위성 자료의 성능이 크게 개선됨에 따라 최근에는 위성을 이용하여 광범위한 영역에 대한 실시간 안개 탐지 알고리즘들이 개발되고 있다. 한반도 주변을 관측하는 기상위성 중 관측주기가 10분으로 시간해상도가 가장 우수한 GEO-KOMPSAT-2A/Advanced Meteorological Imager (GK2A/AMI)는 공간해상도가 500 m이다. 반면 GEO-KOMPSAT-2B/Geostationary Ocean Color Imager-II (GK2B/GOCI-II)는 해상도가 250 m지만, 1시간 주기로 관측하고 가시채널만 보유하고 있다. 따라서 본 연구에서는 한반도 주변에서 발생하는 안개를 10분 및 250 m 해상도로 탐지하기 위해 GK2AB 융합 안개 탐지 알고리즘(Fog Detection Algorithm, FDA)인 GK2AB FDA를 개발하였다. GK2AB FDA는 세 파트로 구성된다. 첫 번째로 현업 운용중인 GK2A 안개 탐지 알고리즘(GK2A FDA)으로 10분 및 500 m 해상도로 안개를 탐지한다. 두 번째 단계에서는 두 위성 자료 간 시공간 일치, 태양천정각과 파장역 차이를 보정한 GK2A normalized visible (NVIS)의 10분 변화량을 이용하여 GK2B NVIS를 10분 간격으로 외삽한다. 마지막 단계에서는 외삽된 GK2B NVIS, 태양천정각, GK2A FDA 산출물 등을 입력자료로 기계학습(의사결정나무)을 이용하여 개발된 GK2AB FDA로 지리적위치에 따라 안개를 탐지(250 m, 10분)한다. GK2AB FDA의 훈련에는 6개 사례, 검증에는 4개 사례가 이용되었다. GK2AB FDA의 정량적 검증에는 지상관측 시정, 풍속 그리고 상대습도 자료를 이용하였다. GK2AB FDA는 GK2A FDA에 비해 공간해상도가 4배 증가함에 따라 안개 및 비안개 화소가 보다 자세히 구분되었다. 또한 검증방법에 관계없이 GK2A FDA에 비해 probability of detection (POD)은 높고 Hanssen-Kuiper Skill score (KSS)는 높거나 비슷함을 보여 안개 탐지 수준이 개선된 것으로 보인다. 하지만 일부 사례에서는 GK2AB FDA의 false alarm ratio (FAR)와 Bias가 크게 나타나 안개를 과대탐지하는 문제를 보이고 있다.

활성탄에 의한 Acid Black과 Quinoline Yellow의 흡착특성 및 파라미터 (Adsorption Characteristics and Parameters of Acid Black and Quinoline Yellow by Activated Carbon)

  • 이경호;황은진;백우승;이종집;동종인
    • 청정기술
    • /
    • 제26권3호
    • /
    • pp.186-195
    • /
    • 2020
  • 활성탄에 의한 Acid black(AB)과 Quinoline yellow(QY)의 등온흡착과 속도실험을 염료의 초기농도, 접촉 시간, 온도 및 pH를 흡착변수로 수행하여 등온흡착과 동력학적, 열역학적 파라미터에 대해 조사하였다. 흡착평형자료는 Freundlich 등온흡착식에 잘 맞았으며, 계산된 Freundlich 분리계수 값으로부터 활성탄이 AB와 QY를 효과적으로 제거할 수 있다는 것을 알았다. 속도실험 데이터는 흡착공정은 유사 이차 반응속도식이 오차율 10% 이내로 잘 맞았다. 입자 내 확산식에 대한 결과는 두단계의 직선으로 구분되었다. 입자내 확산을 나타내는 두 번째 직선의 기울기가 경계층 확산의 기울기보다 작아서 입자 내 확산이 속도지배단계인 것을 확인하였다. 열역학 실험으로부터 AB와 QY의 활성화 에너지는 각각 19.87 kJ mol-1, 14.17 kJ mol-1였고 물리흡착공정(5 ~ 40 kJ mol-1)에 해당하였다. 활성탄에 의한 AB와 QY의 흡착반응의 자유에너지 변화는 298 ~ 318 K 범위에서 모두 음의 수치를 나타냈기 때문에 흡착반응이 자발적이었으며 온도가 증가할수록 자유에너지 값이 감소하였기 때문에 자발성이 더 높아졌다. pH 변화실험 결과, 활성탄에 의한 AB와 QY는 해리하여 발생한 음이온의 영향으로 pH 3에서 가장 높은 흡착제거율을 나타냈으며, 흡착메카니즘은 정전기적 인력이었다.

Radioimmunoimaging with Mixed Monoclonal Antibodies of Nude Mice Bearing Human Lung Adenocarcinoma Xenografts

  • Duan, Dong;Li, Shao-Lin;Zhu, Yu-Quan;Zhang, Tao;Lei, Cheng-Ming;Cheng, Xiang-Hua
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권9호
    • /
    • pp.4255-4261
    • /
    • 2012
  • The present study was conducted to evaluate radioimmunoimaging (RII) and in vivo distribution of mixed antibodies $^{99m}Tc$-EGFR-mAb and $^{99m}Tc$-CD44-mAb in nude mice bearing human lung adenocarcinoma xenografts. Single and mixed applications of the two radiolabeled monoclonal antibodies (mAbs) were compared. Direct labeling of $^{99m}Tc$ was applied to radiolabel the EGFR and CD44 mAbs. The properties of the radiolabeled antibodies were then characterized. RII and assessment of the distribution of the antibodies in nude mice bearing lung adenocarcinoma xenografts were achieved by applying separate and combined doses of $^{99m}Tc$-EGFR-mAb and $^{99m}Tc$-CD44-mAb. The labeling rates of $^{99m}Tc$ for EGFR-mAb and CD44-mAb were $91.5%{\pm}3.8%$ and $92.3%{\pm}4.1%$ respectively, with specific activities of 2.8 and $2.9MBq/{\mu}g$, respectively, and radiochemical purities (RCP) of 96.5% and 96.2%. The radioactivity uptake of the combined application of both radiolabeled antibodies was clearly higher than with a single application of either alone. The relative values of target-to-nontarget (T/NT) measured through the regional interest (ROI) technique were $5.59{\pm}0.42$ (mixed antibodies), $2.78{\pm}0.20$ ($^{99m}Tc$-EGFR-mAb), and $2.28{\pm}0.16$ ($^{99m}Tc$-CD44-mAb) in the RII. The body distribution of the radiolabeled antibodies and their imaging results were basically identical. Application of the mixed antibodies with $^{99m}Tc$-EGFR-mAb and $^{99m}Tc$-CD44-mAb can increase the radioactivity uptake of tumor tissue, leading to more ideal target-to-nontarget ratios, and therefore superior results.