• Title/Summary/Keyword: ATPdraw

Search Result 85, Processing Time 0.021 seconds

A Study and Analysis on the Switching Surge Using EMTP/ATPDraw in Combined Distribution Systems (혼합배전계통에서 EMTP/ATPDraw를 이용한 개폐서지 해석)

  • Lee, Jang-Geun;Lee, Jong-Beom;Lee, Jae-Bong;Kim, Beong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.280-282
    • /
    • 2005
  • This paper describes switching overvoltage generated during transient state in 22.9kV combined distribution systems. For analysis, distribution overhead line, underground cable and surge arrester are modeled using EMTP/ATPDraw. Simulation results show switching overvoltage according to various kind of parameter and systems such as closing angle and cable length.

  • PDF

A Study of the Operating Characteristic for Voltage Restrained Overcurrent Relay using the ATPDraw5.7p4 Modeling Data (ATPDraw5.7p4 모델링 데이터를 이용한 전압억제 과전류계전기 동작특성에 관한 연구)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • The market of domestic Power Plant Generator Protection and Control System (GPCS) is narrow and required the high reliability, and technology. So, it is still operated as turn-key. In recent years, digital relays has evolved into IED can perform the control and monitoring functions without central monitoring based on IEC61850 international standards communications, and attention for advancement of smart grid and ECMS has been increased in South Korea. The increasing attention on multi-function IED, DGPS(digital generator protection system), for internal fault protection of large generator results in starting a national project in South Korea, the IED prototype development for next-generation power units. The voltage restrained overcurrent relay have been used as back-up overcurrent protection for generators. In this paper, voltage restrained overcurrent relay is one of the back-up protective factors in generator protection IED was presented. For evaluation performance of the voltage restrained overcurrent relay, the data of ATPDraw5.7p4 modeling was used.

Modelling and Performance Analysis of UPFC Using EMTP/ATPDraw (EMTP/ATPDraw를 이용한 UPFC구현 및 동작 분석)

  • Jang, Won-Hyeok;Lee, You-Jin;Rhee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.217-219
    • /
    • 2008
  • Among the Flexible AC Transmission Systems (FACTS) devices, Unified Power Flow Controller (UPFC) is considered as the most powerful and versatile one as it provides simultaneous, real time control of the transmission parameters, voltages, impedances, and phase angles which determine the power flow in AC transmission systems. This paper presents modelling of UPFC and describes its characteristics. The UPFC implemented in this paper is based on Sinusoidal Pulse Width Modulation (SPWM) and Electro-Magnetic Transients Program (EMTP)/ATPDraw is used to model and analyze it. The simulation results confirm advantages of UPFC in operational performance with respect to the steady state Power flow regulation and the transient stability control.

  • PDF

A Study and Analysis on the Switching Surge Using a EMTP/ATPDraw in the Combined Distribution System (혼합배전계통에서 EMTP/APTDraw를 이용한 개폐서지 해석에 관한 연구)

  • Lee, Jang-Geun;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.175-177
    • /
    • 2005
  • This paper analyzes transient behavior due to switching overvoltage in 22.9kV combined distribution systems. Computer models are consisted of distribution overhead line model, underground cable model and surge-arrester model in this paper. The computer models are made by EMTP/ATPDraw simulation and Line constants are calculated by ATP_LCC. This paper analyzes the various parameters affecting. These factors include closing angle and cable length.

  • PDF

ATPDraw Simulation for Transient Phenomena Analysis of Electrical Shock Underwater (수중 전격 과도현상 해석을 위한 ATPDraw 시뮬레이션)

  • Jung, Jong-Wook;Jung, Jin-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.48-54
    • /
    • 2007
  • This paper describes the analysis of transient phenomena on the point that a human body suffers an electrical shock. A couple of case studies were discussed by using an ATPDraw simulation tool. Two models for the case studies were constructed on the assumption that the electrical shock event takes place under water to simulate the severest condition ; the first model that the human body contacts with an energized part exposed to water ; the second model that both hands and feet simultaneously contact with the ground under water. After modeling, the transient phenomena for the models were analyzed by comparing the voltages and currents calculated at each part of the human body. As a result steep front kicks in voltage and current were observed as transient phenomena on the point that the human body contacts with the energized part exposed to water in the first model and the magnitudes of the kicks considerably increased. It was considered however, the effect of the kicks due to the commercial power source on the human body could be neglected because the product of the current through the body and the short duration is less than the safety limit. When both hands and feet simultaneously contact with the ground in the second model, the voltage generally decreased all over the body parts, while the current flowing through the chest abruptly increased. The duration of this current was very shot, as well, thus its effect on the electrical shock is considered insignificant. After all, it was confirmed through the simulation results that the electrical shock depends on the magnitude in voltage and the body impedance.

Surge Analysis Considering Variation of Line Configuration Factor in Combined Distribution Systems with Power Cables (혼합배전계통 선로구성요소 변화를 고려한 선로 서지해석)

  • Kim, Byong-Sook;Lee, Jang-Geun;Han, Byoung-Sung;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.472-480
    • /
    • 2007
  • This paper analyzes overvoltage on testing line for various parameter effect examination. Model systems consist of overhead line and underground cable. The model considered actual characteristic data of distribution lines. and will be constructed at testing yard. The simulations were performed under various line configuration such as cable kinds, cable length, lightning wave, lightning wave time, transformer and branch circuits. The simulation models are established by EMTP/ATPDraw and Line Constants are calculated by ATP_LCC. When lightning surge strikes on conductor of overhead line, EMTP/ATPDraw calculates overvoltage in many cases. Simulation results will be compared with real testing results at testing yard. The compared results will be used to establish protection methods in actual underground distribution systems.

Analysis and Reduction Methods of Sheath Circulating Current in Underground Transmission Systems (지중송전계통에서 시스순환전류 해석 및 저감방안)

  • Jeong, Chae-Gyun;Lee, Jong-Beom;Gang, Ji-Won;Jang, Tae-In
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.11
    • /
    • pp.537-545
    • /
    • 2001
  • This paper describes the analysis of sheath circulating current and various methods to reduce the large circulating current in case of operating cable system using EMTP/ATPDraw. And also, possible methods are proposed through a detailed analysis regarding cable systems by considering various electrical and environmental factors. It is evaluated that the proposed reduction methods can be effectively applied to reduce the large sheath circulating over current with the minimized electrical problems.

  • PDF

Neutral Current Calculation of the One Step Type Pole using KEPCO's Distribution System (한전 실 배전계통 모델을 이용한 1단 장주 중성선 전류 계산)

  • Seo, H.C.;Park, K.W.;Kim, C.H.;Jung, C.S.;Yoo, Y.P.;Lim, Y.H.;Seol, I.H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.35-40
    • /
    • 2007
  • The one step type and two step type pole are used in distribution line. If the three phases are not balanced, the communication line can be damaged by induced voltage. This paper calculates the neutral current using KEPCO's distribution system model which is only composed by one step type pole. The used system model is modelled by using ATPDraw and the neutral current is calculated by using EMTP/MODELS. Many cases for abstracting the neutral current characteristics in KEPCO's distribution system are simulated and analyzed.

A Lightning Surge Analysis of Testing Line for Protection of Underground Distribution Systems (지중배전계통 보호를 위한 모의시험선로 서지특성 해석)

  • Kim Byoung-Sung;Lee Jang-Geun;Lee Jong-Beom;Han Byong-Sook
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.8
    • /
    • pp.313-321
    • /
    • 2006
  • This paper describes the overvoltage obtained by surge behavior analysis in testing underground distribution systems. Model systems consist of overhead distribution line and underground cable. Such model system considered various characteristics of actual distribution systems will be soon constructed at testing yard. Simulation is carried out under various states such as cable kinds, cable length, lightning wave and time, and branch circuits. Model is established by EMTP/ATPDraw. Line Constants are calculated by ATP_LCC. When the direct lightning surge strikes on conductor of overhead line, the overvoltage is calculated using EMTP/ATPDraw in many cases. Simulation results will be compared with real testing results at testing yard in the near future. The compared results will be used to establish protection methods in actual underground distribution systems.