• Title/Summary/Keyword: AR Method

Search Result 1,442, Processing Time 0.029 seconds

A Study on Plasma Corrosion Resistance and Cleaning Process of Yttrium-based Materials using Atmospheric Plasma Spray Coating (Atmospheric Plasma Spray코팅을 이용한 Yttrium계 소재의 내플라즈마성 및 세정 공정에 관한 연구)

  • Kwon, Hyuksung;Kim, Minjoong;So, Jongho;Shin, Jae-Soo;Chung, Chin-Wook;Maeng, SeonJeong;Yun, Ju-Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.74-79
    • /
    • 2022
  • In this study, the plasma corrosion resistance and the change in the number of contamination particles generated using the plasma etching process and cleaning process of coating parts for semiconductor plasma etching equipment were investigated. As the coating method, atmospheric plasma spray (APS) was used, and the powder materials were Y2O3 and Y3Al5O12 (YAG). There was a clear difference in the densities of the coatings due to the difference in solubility due to the melting point of the powdered material. As a plasma environment, a mixed gas of CF4, O2, and Ar was used, and the etching process was performed at 200 W for 60 min. After the plasma etching process, a fluorinated film was formed on the surface, and it was confirmed that the plasma resistance was lowered and contaminant particles were generated. We performed a surface cleaning process using piranha solution(H2SO4(3):H2O2(1)) to remove the defect-causing surface fluorinated film. APS-Y2O3 and APS-YAG coatings commonly increased the number of defects (pores, cracks) on the coating surface by plasma etching and cleaning processes. As a result, it was confirmed that the generation of contamination particles increased and the breakdown voltage decreased. In particular, in the case of APS-YAG under the same cleaning process conditions, some of the fluorinated film remained and surface defects increased, which accelerated the increase in the number of contamination particles after cleaning. These results suggest that contaminating particles and the breakdown voltage that causes defects in semiconductor devices can be controlled through the optimization of the APS coating process and cleaning process.

A Study on the Influence of Augmented Reality Experience in Mobile Applications on Product Purchase (모바일 어플리케이션의 증강현실 이용경험이 제품구매에 미치는 영향 연구)

  • Kim, Minjung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.6
    • /
    • pp.971-978
    • /
    • 2022
  • As a marketing method in a non-face-to-face society, the purpose of this study is to test how AR experience affects purchase intention in the process of consumers recognizing product information to purchase products and to secure the basis for the effectiveness of developing and introducing augmented reality functions in future product brand applications. Literary research methods and empirical research methods were used to verify the research purpose, and to measure this, an application of domestic tableware brand 'Odense', which implements augmented reality functions, was produced and used as an experimental tool. Also, a direct causal relationship was attempted by constituting a questionnaire by deriving a measurement scale for perceived usefulness, perceived ease, perceived pleasure, and purchase, which are factors of technology acceptance theory (TAM), and empirical analysis was conducted using the SPSS 25.0 statistical package to achieve the purpose of the study. As a result of the study, significant results were derived from all factors in the effect of perceived usefulness, ease, and pleasure on purchase intention, and several significant differences were found among factors according to gender, age, and internet shopping usage time in general characteristics. In conclusion, the user experience of the medium in which the augmented reality function is introduced in the information recognition stage of the product has a positive effect on purchase compared to the user experience of existing applications.

Behavioral Change of Workers who completed Experiential Safety Training (체험식 안전교육 이수 근로자의 행동 변화 연구)

  • Choonhwan, Cho
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.161-172
    • /
    • 2023
  • Safety education delivered to construction workers in a lecture manner has limitations in concentration and immersion, so delivery power and interest are low. In order to improve unstable behavior through education and prevent safety accidents, it is necessary to change the paradigm to hands-on education. Purpose: Experiential safety education aims to contribute to preventing accidents for construction workers by quickly recognizing risks, improving emergency response skills, and verifying the effectiveness of pre- and post-learning. Method: Based on a survey of workers who experienced the same work environment as the actual construction site, an opinion survey on the pre- and post-safety experience education and a variable measurement tool were planned, and a research hypothesis was established. Results: The Bayesian theory and MC simulation analysis were used to analyze the structural equation model, and the change in construction worker behavior was confirmed through the intended safety (A), non-experiential education in the sub-area of anxiety (B), average, standard deviation, and minimum and maximum values. Conclusion: The effect of education and industrial accidents are reduced only when construction workers are motivated to participate.

Determination of Tumor Boundaries on CT Images Using Unsupervised Clustering Algorithm (비교사적 군집화 알고리즘을 이용한 전산화 단층영상의 병소부위 결정에 관한 연구)

  • Lee, Kyung-Hoo;Ji, Young-Hoon;Lee, Dong-Han;Yoo, Seoung-Yul;Cho, Chul-Koo;Kim, Mi-Sook;Yoo, Hyung-Jun;Kwon, Soo-Il;Chun, Jun-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.59-66
    • /
    • 2001
  • It is a hot issue to determine the spatial location and shape of tumor boundary in fractionated stereotactic radiotherapy (FSRT). We could get consecutive transaxial plane images from the phantom (paraffin) and 4 patients with brain tumor using helical computed tomography(HCT). K-means classification algorithm was adjusted to change raw data pixel value in CT images into classified average pixel value. The classified images consists of 5 regions that ate tumor region (TR), normal region (NR), combination region (CR), uncommitted region (UR) and artifact region (AR). The major concern was how to separate the normal region from tumor region in the combination area. Relative average deviation analysis was adjusted to alter average pixel values of 5 regions into 2 regions of normal and tumor region to define maximum point among average deviation pixel values. And then we drawn gross tumor volume (GTV) boundary by connecting maximum points in images using semi-automatic contour method by IDL(Interactive Data Language) program. The error limit of the ROI boundary in homogeneous phantom is estimated within ${\pm}1%$. In case of 4 patients, we could confirm that the tumor lesions described by physician and the lesions described automatically by the K-mean classification algorithm and relative average deviation analyses were similar. These methods can make uncertain boundary between normal and tumor region into clear boundary. Therefore it will be useful in the CT images-based treatment planning especially to use above procedure apply prescribed method when CT images intermittently fail to visualize tumor volume comparing to MRI images.

  • PDF

A study on a flow of the technological convergence in webtoon - Focused on the interactiontoon of webtoon (기술 융합형 웹툰의 몰입도 연구 -인터랙션 툰 <마주쳤다>를 중심으로)

  • Baek, Eun-Ji;Son, Ki-Hwan
    • Cartoon and Animation Studies
    • /
    • s.50
    • /
    • pp.101-130
    • /
    • 2018
  • Since the advent of the Smart Devices, the smartphone has become a popular tool to view Webtoon. This phenomenon has caused the convergence of cutting-edge technologies and Webtoons in diverse forms, creating unique versions of Webtoons including, but not limited to Smart-toon, Effect-toon, Cut-toon, Dubbing-toon, Moving-toon, AR-toon, VR-toon, and Interaction-toon. By comparison to these rich diversities of Webtoons in the online industry, there is a lack of academic research on this topic. There are some papers which talk about the different types of multimedia technology conversion and its case presentation or the effectiveness and problems of visual effect, but the effects of these convergence technologies on comic readers' concentration and reading effectiveness have never been investigated so far. Therefore, this paper will discuss the unique method of immersive storytelling that is often used in comics and analyze each aspects of immersive method in technology-converged Webtoons along with its problems. Furthermore, this paper will analyze different aspects of "immersion" and interaction elements that can be found in the popular Interaction-toon, (Encountered). Through this, this paper discusses the positive influence of the interaction elements on comic readers' immersion level and its limitation. To classify the technology-converged Webtoons in terms of the immersion level, the Effect-toon sometimes interferes viewer's flow by using excessive use of multimedia effect, creating information overload. The Smart-toon which applied motions to each frame under horizontal mode of smartphones was a good try, but it hindered the readers' activeness and made it hard for the readers to be fully absorbed in the story. The VR-toon, which utilizes virtual reality gadgets to allow viewers to explore the world of Webtoon was also a nice try to overcome the limitation of vertical screens. However, it often caused dispersion of user's attention and reduced the users' immersion level. The Moving-toon which only emphasized the reading convenience also invaded readers' activeness and disturb users' concentration. On the other hand, the cartoonist Il-Kwon Ha applied high technologies such as face recognition technology, augmented reality techniques, 360-degree panorama technology, and haptic technology to his cartoon (Encountered). This allowed the readers to form a sense of closeness towards the cartoon characters which let the readers to identify themselves with the characters and interact with them. By this way, the readers can be fully immersed in the story. However, technology abuse, impractical production and hackneyed storylining often showed later in the story remains as its limitations.

$Ca^{++}$ Polls in Isolated Rabbit and Turtle Heart (적출된 토끼와 자라심장에서의 $Ca^{++}$ Pool)

  • Kim, In-Kyo;Lee, Joong-Woo;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.9 no.1
    • /
    • pp.13-22
    • /
    • 1975
  • From the study of movements of $Ca^{++}$ in frog cardiac muscle, Niedergerke (1963) postulated that $Ca^{++}$ necessary for the cardiac contraction is stored in a specific pool. Langer et al (1967) and DeCaro (1967) also found a close relationship between the change of $Ca^{++}$ flux kinetics and the change of contractile force. According to the studies of several investigators, Ca II (Bailey and Dressel 1968) or phase I and II (Langer 1965, Langer et al 1967, 1971) in the $Ca^{++}$ washout curve was associated with cardiac contractility. This investigation was aimed to elucidate the anatomical region of the contractile active $Ca^{++}$ pool. At the same time, it was assumed in this study that $Ca^{++}$ in the sarcoplasmic reticulumn represents one of the major intracellular $Ca^{++}$ pool and cardiac contractility was also dependent on the intracellular $Ca^{++}$ concentration. Consequently, this experiment was performed at different temperatures to activate to activate inhibit the deactivating process of activated $Ca^{++}$ in the intracellular space to see if changes in the contractility decay curve existed at different temperatures. The isolated hearts of rabbits and turtles (Amyda maackii) were attached to the perfusion apparatus according to the method employed by Bailey and Dressel (1968). The isolated hearts were initally perfused with a full Ringer solution containing 2 mg/ml of inulin for 1 hr, and then $Ca^{++}$ and inulin-free Ringer solution was perfused while the isometric tension was recorded and a serial sample of perfusion fluid dripping from the cardiac apex was collected for 10 sec throughout experimental period. The above procedure was performed at $23^{\circ}C$, $30^{\circ}C$ and $38^{\circ}C$ on the rabbit heart and $10{\sim}13^{\circ}C$, $10^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$ on the turtle heart. After determination of $Ca^{++}$ and inulin concentration of the samples, the $Ca^{++}$, inulin washout curve and the contractile tensin decay curve were analysed according to the method of Riggs (1963). The results were summarized as follows; 1. In the rabbit heart, there are 2 inulin compartments, 3 $Ca^{++}$ compartments and sing1e exponential decay of contractile tension. In the turtle heart, there are $1{\sim}2$ inulin compartments, $1{\sim}2$ $Ca^{++}$ compartments and $1{\sim}2$ phases of contractile tension decay. The fact that the inulin space was divided into 3 compartments in the washout curve in these hearts indicates the presence of heterogeneity in cardiac perfusion, i.e., overfused and underperfused area. 2. Ca I a9d Ca II in these hearts were found to have $Ca^{++}$ in the ECF compartments because their half times in the washout curves were far smaller than those of the inulin washout curves in the rabbit heart and similar to those of the inulin washout curves in the turtle heart. Ca III in the rabbit heart may have originated from the intracellular $Ca^{++}$ store. But no Ca III in the turtle heart was found. This may be due to the fact that the iutracellular $Ca^{++}$ pool in the turtle heart was too small to detect using this experimental procedure since sarcoplasmic reticulumn in the turtle heart is poorly developed. 3. In the rabbit heart, there were no chages in the half time of Ca I, Ca II, inulin I and inulin II at different temperatures, but the half time of Ca III was significantly prolonged at lower temperatures, and the half time of the contractile tension decay tended to be prolonged at lower temperatures but this was not significant. In the turtle heart, there were no changes in the half time of Ca I, Ca II, inulin 1, inulin II and phase I of the contractile tension decay at different temperatures, but the half time of phase II of the contractile tension decay was significantly prolonged at lower temperatures. This finding indicates that intracellu!ar $Ca^{++}$ in these hearts was also responsible particulary for maintaining the cardiac contractility at the lower temperatures. 4. The half times of contractile tension decay were shorter than those of Ca II in the $Ca^{++}$ washout curves in both animal hearts. According to the above results it was shown that $Ca^{++}$ in ECF is primarily and $Ca^{++}$ in the intracellular space is partially associated with the cardic contractility.

  • PDF

Importance of Strain Improvement and Control of Fungal cells Morphology for Enhanced Production of Protein-bound Polysaccharides(β-D-glucan) in Suspended Cultures of Phellinus linteus Mycelia (Phellinus linteus의 균사체 액상배양에서 단백다당체(β-D-glucan)의 생산성 향상을 위한 균주 개량과 배양형태 조절의 중요성)

  • Shin, Woo-Shik;Kwon, Yong Jung;Jeong, Yong-Seob;Chun, Gie-Taek
    • Korean Chemical Engineering Research
    • /
    • v.47 no.2
    • /
    • pp.220-229
    • /
    • 2009
  • Strain improvement and morphology investigation in bioreactor cultures were undertaken in suspended cultures of Phellinus linteus mycelia for mass production of protein-bound polysaccharides(soluble ${\beta}$-D-glucan), a powerful immuno-stimulating agent. Phellineus sp. screened for this research was identified as Phellinus linteues through ITS rDNA sequencing method and blast search, demonstrating 99.7% similarity to other Phellinus linteus strains. Intensive strain improvement program was carried out by obtaining large amounts of protoplasts for the isolation of single cell colonies. Rapid and large screening of high-yielding producers was possible because large numbers of protoplasts ($1{\times}10^5{\sim}10^6\;protoplasts/ml$) formed using the banding filtration method with the cell wall-disrupting enzymes could be regenerated in relatively high regeneration frequency($10^{-2}{\sim}10^{-3}$) in the newly developed regeneration medium. It was demonstrated that the strains showing high performances in the protoplast regeneration and solid growth medium were able to produce 5.8~6.4%(w/w) of ${\beta}$-D-glucan and 13~15 g/L of biomass in stable manners in suspended shake-flask cultures of P. linteus mycelia. In addition, cell mass increase was observed to be the most important in order to enhance ${\beta}$-D-glucan productivity during the course of strain improvement program, since the amount of ${\beta}$-D-glucan extracted from the cell wall of P. linteus mycelia was almost constant on the unit biomass basis. Therefore we fully investigated the fungal cell morphology, generally known as one of the key factors affecting cell growth extent in the bioreactor cultures of mycelial fungal cells. It was found that, in order to obtain as high cell mass as possible in the final production bioreactor cultures, the producing cells should be proliferated in condensed filamentous forms in the growth cultures, and optimum amounts of these filamentous cells should be transferred as active inoculums to the production bioreactor. In this case, ideal morphologies consisting of compacted pellets less than 0.5mm in diameter were successfully induced in the production cultures, resulting in shorter period of lag phase, 1.5 fold higher specific cell growth rate and 3.3 fold increase in the final biomass production as compared to the parallel bioreactor cultures of different morphological forms. It was concluded that not only the high-yielding but also the good morphological characteristics led to the significantly higher biomass production and ${\beta}$-D-glucan productivity in the final production cultures.

Growth and Opto-electric Characterization of ZnSe Thin Film by Chemical Bath Deposition (CBD(Chemical Bath Deposition)방법에 의한 ZnSe 박막성장과 광전기적 특성)

  • Hong, K.J.;You, S.H.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.62-70
    • /
    • 2001
  • The ZnSe sample grown by chemical bath deposition (CBD) method were annealed in Ar gas at $45^{\circ}C$. Using extrapolation method of X-ray diffraction pattern, it was found to have zinc blend structure whose lattice parameter $a_o$ was $5.6687\;{\AA}$. From Hall effect, the mobility was likely to be decreased by impurity scattering at temperature range from 10 K to 150 K and by lattice scattering at temperature range from 150 K to 293 K. The band gap given by the transmission edge changed from $2.700{\underline{5}}\;eV$ at 293 K to $2.873{\underline{9}}\;eV$ at 10 K. Comparing photocurrent peak position with transmission edge, we could find that photocurrent peaks due to excition electrons from valence band, ${\Gamma}_8$ and ${\Gamma}_7$ and to conduction band ${\Gamma}_6$ were observed at photocurrent spectrum. From the photocurrent spectra by illumination of polarized light on the ZnSe thin film, we have found that values of spin orbit coupling splitting ${\Delta}so$ is $0.098{\underline{1}}\;eV$. From the PL spectra at 10K, the peaks corresponding to free bound excitons and D-A pair and a broad emission band due to SA is identified. The binding energy of the free excitons are determined to be $0.061{\underline{2}}\;eV$ and the dissipation energy of the donor -bound exciton and acceptor-bound exciton to be $0.017{\underline{2}}\;eV$, $0.031{\underline{0}}\;eV$, respectively.

  • PDF

Regression of Left Ventricular Mass after Aortic Valve Replacement in Isolated Aortic Regurgitation (단독 대동맥판막 폐쇄부전 환자에서 대동맥판막 치환술 후 좌심실 질량의 변화)

  • Jung, Tae-Eun;Lee, Dong-Hyup;Lee, Seok-Soo
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.614-618
    • /
    • 2010
  • Background: The aim of our study was to assess the extent of regression of left ventricular mass after aortic valve replacement in isolated aortic regurgitation. Material and Method: Retrospective analysis of echocardiographic data was collected preoperative and postoperative 1 year. There were 20 patients (12 males, 8 females, mean age $55.8{\pm}11.8$ years, mean body surface area $1.64{\pm}0.19m^2$) with aortic regurgitation from 2002 through 2007. We studied the change of left ventricular ejection fraction, ventricular septum and left ventricular posterior wall thickness, and left vemtricular muscle index (LVMI). The control group was age matched with normal echocardiographic study results. Patients with combined surgery or infective endocarditis were excluded. Result: Seven cases of tissue valves and thirteen cases of mechanical valve were used. The valve sizes were 21 mm (3 cases), 23 mm (13 cases) and 25 mm (4 cases). The postoperative ($125.5{\pm}42g/m^2$) LVMI has decreased than preoperative LVMI ($212.3{\pm}80g/m^2$, p=0.000) but higher than that of control group ($80.5{\pm}15.9g/m^2$, p=0.000). Postoperative septal wall (systolic/diastolic: $13.5{\pm}3.4mm/17.1{\pm}4.1mm$) and left ventricular posterior wall (systolic/diastolic: $12.9{\pm}3.4mm/16.7{\pm}3.4mm$) thickness were slightly decreased after the valve replacement but was not significantly different than preoperative levels. And postoperative interventricular septal wall and left ventricular posterior wall thickness (systolic/diastolic: $8.6{\pm}1.4mm/12.1{\pm}1.7mm$, systolic/diastolic: $8.4{\pm}1.4mm/13.2{\pm}1.9mm$) were higher than that of the control group (p<0.001). Conclusion: The significant regression of LVMI after aortic valve replacement developed at postoperative one year but the level was higher than control group. The main cause of decreased LVMI is decreased in left ventricular dimension.

A Study of Mo Back Electrode for CIGSe2 Thin Film Solar Cell (CIGSe2 박막태양전지용 Mo 하부전극의 물리·전기적 특성 연구)

  • Choi, Seung-Hoon;Park, Joong-Jin;Yun, Jeong-Oh;Hong, Young-Ho;Kim, In-Soo
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.3
    • /
    • pp.142-150
    • /
    • 2012
  • In this Study, Mo back electrode were deposited as the functions of various working pressure, deposition time and plasma per-treatment on sodalime glass (SLG) for application to CIGS thin film solar cell using by DC sputtering method, and were analyzed Mo change to $MoSe_2$ layer through selenization processes. And finally Mo back electrode characteristics were evaluated as application to CIGS device after Al/AZO/ZnO/CdS/CIGS/Mo/SLG fabrication. Mo films fabricated as a function of the working pressure from 1.3 to 4.9mTorr are that physical thickness changed to increase from 1.24 to 1.27 ${\mu}m$ and electrical characteristics of sheet resistance changed to increase from 0.195 to 0.242 ${\Omega}/sq$ as according to the higher working pressure. We could find out that Mo film have more dense in lower working pressure because positive Ar ions have higher energy in lower pressure when ions impact to Mo target, and have dominated (100) columnar structure without working pressure. Also Mo films fabricated as a function of the deposition time are that physical thickness changed to increase from 0.15 to 1.24 ${\mu}m$ and electrical characteristics of sheet resistance changed to decrease from 2.75 to 0.195 ${\Omega}/sq$ as according to the increasing of deposition time. This is reasonable because more thick metal film have better electrical characteristics. We investigated Mo change to $MoSe_2$ layer through selenization processes after Se/Mo/SLG fabrication as a function of the selenization time from 5 to 40 minutes. $MoSe_2$ thickness were changed to increase as according to the increasing of selenization time. We could find out that we have to control $MoSe_2$ thickness to get ohmic contact characteristics as controlling of proper selenization time. And we fabricated and evaluated CIGS thin film solar cell device as Al/AZO/ZnO/CdS/CIGS/Mo/SLG structures depend on Mo thickness 1.2 ${\mu}m$ and 0.6 ${\mu}m$. The efficiency of CIGS device with 0.6 ${\mu}m$ Mo thickness is batter as 9.46% because Na ion of SLG can move to CIGS layer more faster through thin Mo layer. The adhesion characteristics of Mo back electrode on SLG were improved better as plasma pre-treatment on SLG substrate before Mo deposition. And we could expect better efficiency of CIGS thin film solar cell as controlling of Mo thickness and $MoSe_2$ thickness depend on Na effect and selenization time.