• Title/Summary/Keyword: APU (Auxiliary Power Unit)

Search Result 33, Processing Time 0.029 seconds

A Control Algorithm for Highly Efficient Operation of Auxiliary Power Unit in a Series Hybrid Electric Bus (직렬형 하이브리드 버스에서 보조동력장치의 고효율 작동을 위한 제어 알고리즘)

  • 함윤영;송승호;민병문;노태수;이재왕;이현동;김철수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.5
    • /
    • pp.170-175
    • /
    • 2003
  • A control algorithm is developed for highly efficient operation of auxiliary power unit (APU) that consists of a diesel engine and a directly coupled induction generator in series hybrid electric Bus (SHEB). In a series hybrid configuration the APU supplies the electric power needed for maintaining the state of charge (SOC) of the battery unit in various conditions of vehicle operation. As the rotational speed of generator does not depend on the vehicle speed, an optimized operation of engine-generator unit based on the efficiency map of each component can be achieved. The output torque of diesel engine can be controlled by the amount of fuel injection, and the power converted from mechanical to electrical energy can be adjusted by generate control unit (GCU) using the decoupling vector control of torque and flux. As for the given reference of the generating power, the multiply of speed and torque, many combinations of operating speed and torque are possible. The algorithm decides the new operating point based on the engine efficiency map and generator characteristic curve. During the transition of operating points, the speed controller saturation is avoided using variable limit and filtering of generator torque reference. A test rig and SHEB consist of a 1.5L diesel engine and a 30kw induction generator are constructed by Hyundai Motor Company.

Electromagnetic Analysis on the Torque Motor of Servo Valve for the Fuel Supply System of Auxiliary Power Unit (보조 동력 장치 연료 공급용 서보밸브의 토크모터 전자기 해석)

  • Chang, Se-Myong;Jang, Gang-Won;Jeong, Heon-Sul;Rhee, Dong-Ho
    • Journal of Aerospace System Engineering
    • /
    • v.1 no.3
    • /
    • pp.7-12
    • /
    • 2007
  • As a main part of an utility helicopter, the APU(Auxiliary Power Unit) has a solenoid valve system operated with a torque motor, which controls the flow rate in the fuel supply system. In this paper, we solved the Maxwell potential equations to analyze the electromagnetic force in the torque motor, and some additional analytic methods are used to compute the quantity of torque produced by the torque motor for the given circuit current. For the convenience, small displacement is assumed, and only magneto-static problem is considered for the two-dimensional cross section. The result will be compared with the three-dimensional analysis that will be studied in the near future.

  • PDF

A Study on Improvement of Strength Safety Factor for K55A1 APU Engine Mounts (자주포 보조동력장치 엔진 마운트 강도안전율 향상에 관한 연구)

  • Kim, Byung Hyun;Seo, Jae Hyun;Park, Young Il;Kim, Yong Wook;Kim, Byung Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.281-287
    • /
    • 2016
  • The purpose of this study is to analyze the vibration characteristics and develop a mounting which can improve the strength safety factor to replace the high failure rate APU(auxiliary power unit) imported metal mounts with rubber mount that can be domestically produced. For this study, we analyzed in 3 kinds of rubber mounts hardness for the natural frequency to avoid the average excited frequency of the APU. In addition, allowed vibration acceleration of rubber mount confirmed to 90.8 g by adding a strength safety factor. To assure the validity of the design, we measure the vibration acceleration equipped with a metal mount and rubber mount 2 species(Hs 50 and 60). As a result, the proposed design method in this study is reasonable because the rubber mounts is excellent strength safety factor and vibration transmissibility than metal mounts.

Studies on the improvement of driving gears quality at Inlet Guide Vane of aircraft auxiliary power unit (항공기 보조동력장치 입구안내익 구동기어의 품질개선에 관한 연구)

  • Park, Sungjae;Park, Sunwook;Suh, Jaekyoung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.6
    • /
    • pp.512-519
    • /
    • 2016
  • Auxiliary Power Unit of FA-50 which provides energy other than propulsion is an important element to maintain airworthiness on aircraft. Also Inlet Guide Vane of Auxiliary Power Unit is a device that supplies appropriate airflow into the Auxiliary Power Unit after adjusting influent airflow into the load compressor. This report, based on the problems occurred the driving gears of Inlet Guide Vane, deals with cause of occurrence, troubleshooting, design improvement and result of test flight verification for FA-50 aircraft Auxiliary Power Unit lifespan.

A Study on Optimization of Noise Reduction of Auxiliary Power Unit for Military Tracked Vehicle (군용 궤도장비 보조동력장치의 소음저감 최적화 연구)

  • Lee, Ju-Seung;Kim, Byeong-Ho;Kim, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.336-342
    • /
    • 2018
  • Noise reduction is an important issue in auxiliary power unit(APU) of tracking equipments for using military. In this study, we designed and tested reduction methods of structure borne noise and airborne source noise at the auxiliary power unit. From the bench test results, it is found that the effect of noise reduction is about 22 dB(A) if the silencer is redesigned, which is the rescue structure. However, the influence of noise reduction by air is insufficient. In addition, it is confirmed that the effect of noise reduction is excellent when structure borne noise reduction is applied to the vehicle. We expected that the test results of this study are used as basic data to reduce the noise of other tracking equipment developed later.

A Study on the Flow and Power Characteristics of Rotor in the APU (보조동력장치 회전자 유동 및 출력특성에 관한 연구)

  • Yi, Chung-Seob;Jeong, In-Guk;Yun, Ji-Hun;Suh, Jeong-Se;Lee, Tae-Eui
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.6
    • /
    • pp.805-810
    • /
    • 2011
  • Recently, Use of Auxiliary power unit(APU) is increasing by growing demand for improvement of insufficient electric power and installation of emergency generation devices in military tracked vehicles and civil markets. And the trend is that the units are demanded for smaller size, lighter weight and higher output power, etc to suit consumer demands. To achieve these, it is essential to develop high performance system. Therefore, in this study, it was conducted in numerical analysis to investigate flow characteristics of rotor in APU generator. Also output performance of APU applied on the rotor is analyzed by experimental method. As the result, higher rotating speed of rotor caused high air flow rate at suction and it leads to linear increase of discharging flow rate. The maximum theoretical power was achieved at 12 $m^3$/min of flow rate and, at that time, output power of generator was about 7.825 kW. Also, it can be confirmed the stabilization of output performance is achieved in about 2 seconds by experiment.

A Study on the Life Cycle Cost Evaluation of the Conventional Auxiliary Power Unit for 8200 Series Electric Locomotive (8200호대 전기기관차용 기존품 보조전원장치의 수명주기비용 평가에 관한 연구)

  • Lee, Kye-Seung;Kim, Wan-il;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.2
    • /
    • pp.331-336
    • /
    • 2018
  • In this paper, the life cycle cost of the auxiliary power unit in the conventional 8200 series electric locomotive is evaluated and an effective life cycle cost reduction method is sought. For this, a life cycle cost evaluation model was proposed using IEC 60300-3-3 standard. As a result of analysis, material cost which accounted for a large percentage of preventive maintenance cost, accounted for 64% of total cost, and breakdown maintenance cost was as high as 27%. Except for the cost of preventive maintenance, the breakdown maintenance cost ratio was the highest. In order to reduce the LCC of the auxiliary power unit(APU) of the 8200 series in the future, it is necessary to reduce the material cost in case of development and to secure the high reliability according to the parts manufacturing so as to minimize the maintenance cost.

Research on Technical Trends of IGBT Gate Driver Unit for Railway Car (철도차량용 IGBT Gate Driver Unit 기술 동향 분석 연구)

  • Cho, In-Ho;Lee, Jae-Bum;Jung, Shin-Myung;Lee, Byoung-Hee
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.3
    • /
    • pp.339-348
    • /
    • 2017
  • Power supply for railway cars can be divided into propulsion system power supply and auxiliary power units (APU). The propulsion system power supply is for propulsion of railway cars, and regenerative braking; the APU provides power for the air compressor, lighting, car control and other auxiliary parts. According to high voltage and high current specifications, generally, an insulated-gate bipolar transistor (IGBT) is adopted for the switching component. For appropriate switching operation, a gate driver unit (GDU) is essentially required. In this paper, the technical trends of GDU for railway cars are analyzed and a design consideration for IGBT GDU is described.

Performance test for the compressor of 100kW APU (100kW급 보조동력장치용 압축기 성능시험)

  • Lim, Byeung-Jun;Cha, Bong-Jun;Yang, Soo-Seok;Lee, Kyoung-Jin;Baik, Ki-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.655-660
    • /
    • 2001
  • The performance test of a centrifugal compressor for APU(Auxiliary Power Unit) which is developed by the collaborative research of KARI and Samsung TechWin has been conducted. The investigated compressor consists of a curved inlet, a centrifugal impeller, a channel diffuser and a plenum chamber. The experiments were carried out in an open-loop centrifugal compressor test rig driven by a turbine. For three different diffusers, overall performance data were obtained at 80%, 90% and 97% of design speed. For the initially designed wedge-type diffuser, test results showed that the compressor was operated at a higher mass flow rate than the design requirement. By reducing the diffuser throat area, the compressor operating range was shifted to lower mass flow rate range. The test result of redesigned wedge-type diffuser showed high pressure loss. To reduce the diffuser loss, diffuser inlet radius was increased and airfoil-type of diffuser was adopted. This airfoil-type diffuser showed reasonal results in terms of design requirement.

  • PDF

A Study on the Optimization of Heat Flux in Engine Room of Auxiliary Power Unit for Self-Propelled Artillery (자주포용 보조동력장치 엔진룸의 열유동 최적화에 관한 연구)

  • Noh, Sang Wan;Park, Young Min;Kim, Sung Hoon;Lee, Jae Dong;Kim, Byung Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.629-635
    • /
    • 2019
  • In this study, we analyzed the effect of FAN and oil cooler application on APU. MIL-STD-810 was applied to the atmospheric environment and radiation dose in order to perform thermal flow analysis. The heat flow was analyzed for the case in which the inlet / outlet fan was applied (Case 1), the case in which the inlet fan and the oil cooler were applied (Case 2), and the case in which the inlet / outlet fan and the oil cooler were applied (Case 3). As a result, it was confirmed that the cylinder head temperature of Case 3 was 21.4 times lower than that of Case 1 and 8.0 times lower than that of Case 2. Experiments were conducted under the same ambient conditions in order to examine the validity of the results. The numerical values and experimental results showed a difference of less than 7%. Through this, we were able to confirm that the APU heat flow optimization model satisfies the design conditions. The results of this study are expected to be used as basic data for optimizing heat flow of APU.