• 제목/요약/키워드: ALARP(As Low As Reasonably Practicable)

검색결과 8건 처리시간 0.025초

열차제어시스템의 안전입증에 관한 연구 (A Study on the Safety Demonstration of Train Control System)

  • 신덕호;이재호;이강미;황종규;정의진;왕종배;박영수
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.412-418
    • /
    • 2006
  • In this paper we deal with the APARP theory which has been applied for UK railway system and risk assessment method which has been using in the domestic railway system for the safety demonstration. Both techniques are applied to the ATP wayside equipment for interface. Also, fur the applications of each techniques a analysis of the safety activity and a possibility of the application of ALARP theory are evaluated. Finally, we generate requirements of the safety demonstration for the future domestic railway system by way of the analysis of some assumptions and requirement data which can be applied to the risk assessment of ALARP.

반도체/LCD 제조공정에서의 Silane에 대한 ALARP개념의 화재 폭발 위험성평가에 관한 연구 (A Study on the As Low As Reasonably Practicable (ALARP)-Concept Risk Assessment of Silane in Semiconductor and LCD Process)

  • 이중희;황성민;우인성
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.93-98
    • /
    • 2010
  • 본 연구에서는, 반도체, LCD 공정에서 금속막을 증착하기 위하여 PECVD장비에 화재, 폭발 위험성과 독성을 가진 Silane가스를 사용하게 되는 장비인 gas cabinet, pipeline, VMB(Valve manifold box), MFC(mass flow controller)장비 등, 전반적인 시스템에 대하여 영국 HES의 ALARP개념을 도입하여 위험성 평가를 실시하여 문제점을 도출하고 대책을 강구 하는데 목적이 있고, 여러 가지 문제점중 절대적으로 수용 할 수 없는 Critical Risk로는 Gas Cylinder를 사용하여 Silane을 공급하고자 할 때에는 필히 Gas Cabinet을 사용하여 공급하여야 하고, Tube Trailer를 사용하여 공급하고자 할 때에는 필수적으로 Purge System을 갖추어 공급하여야 한다. 선택적으로 수용할 수 있는 High, Medium Risk로는 Gas Cylinder 또는 Tube Trailer를 사용하여 Silane을 공급하고자 할 때는 Inlet 부분에 RFO(Resticted Flow Orifice)를 설치하여 사용하고 Gas Supply Room에는 CO2소화설비를 적용하지 말고 Water Mist등 물 분무설비를 적용하여야한다.

수소-LPG 복합충전소 정량적 위험성평가에 관한 연구 (A Study on the Quantitative Risk Assessment of Hydrogen-LPG Combined Refueling Station)

  • 강승규
    • 에너지공학
    • /
    • 제28권4호
    • /
    • pp.29-34
    • /
    • 2019
  • 본 연구에서는 수소 복합충전소에 대하여 정량적 위험성 평가를 실시하였다. 평가대상의 복합충전소는 수소-LPG이며 각 충전소의 설비 구성을 분석하고 위험도를 평가하였다. 최종 위험도는 피해영향과 사고빈도를 고려한 개인적 위험성과 사회적 위험성으로 평가한다. 본 연구의 대상이 된 수소-LPG 충전소에 대한 개인적 위험도 산출 결과, 수소-LPG 형태의 복합충전소는 HSE에서 제안하고 있는 허용 불가수준의 위험지역(> 1×10E-3)은 나타나고 있지 않으며, 작업자와 일반인에 대한 개인적 위험수준이 모두 허용범위 내에 분포하고 있다. 그리고 사회적 위험도 평가에서는 해석대상 모델이 허용 가능한 범위(ALARP, As Low As Reasonably Practicable)의 위험도 분포를 보이고 있다. 보다 향상된 안전성 확보를 위해 위험도 순위화 결과에서 높은 위험도를 보이고 있는 수소 저장용기, 디스펜서, 튜브트레일러 누출 및 LPG의 Vapour 회수 라인 등에 대한 정기적인 점검 및 확인을 권장한다.

고정식 수소충전소에서의 Dispenser Module 내 구역별 위험성 평가 (Risk Assessment of Stationary Hydrogen Refueling Station by Section in Dispenser Module)

  • 임상진;김민기;김수;이윤호
    • 해양환경안전학회지
    • /
    • 제29권1호
    • /
    • pp.76-85
    • /
    • 2023
  • 신재생에너지로서 수소에 대한 수요가 증가하고 있으나 기존의 화석 연료와 달리 수소는 연료 공급을 위한 전용 충전소가 필요하며, 이러한 인프라 확보를 위해서 수소충전소의 위험성 평가가 선행되어야 한다. 따라서 본 연구에서는 정성적 위험성평가와 정량적 위험성 평가로 구분하여 수소충전소에 대한 위험성평가를 수행하였다. 정성적 평가는 Hazard and Operability Analysis(HAZOP) 기법을 사용하여 Dispenser Module을 두 개의 Node로 평가하였으며, Criticality Estimation Matrix에 따라 Filter의 막힘으로 인한 사고와 고압 사고의 위험도가 High Level로 평가되었다. 정량적 위험성 평가는 Hydrogen Korea Risk Assessment Module(Hy-KoRAM)을 사용하여 화재의 형상과 피해영향범위를 나타냈고, 개인적 위험도와 사회적 위험도에 대한 평가를 수행하였다. 개인적 위험도는 수소충전소로부터 약 100m 떨어진 공공시설 부근까지 추가적인 안전조치가 고려되는 As Low As Reasonably Practicable(ALARP) 구간의 위험도를 보였고, 사회적 위험도 역시 약 10명의 사망자가 발생할 사고빈도가 1E-04/year로 도출되며 ALARP 구간 내에 나타났다. 정성적·정량적 위험성 평가 결과, 공정 단계의 추가적인 안전 조치와 수소충전소 부근의 제한구역 설정을 통하여 안전성 향상 방안을 제시하였다.

정량적 위험성 평가를 통한 고속도로 휴게소 수소 충전소 안전 가이드라인 연구 (A Study on Safety Guidelines for Hydrogen Refueling Stations at Expressway Service Area using Quantitative Risk Assessment)

  • 김희진;장경민;김수현;김기범;정은상
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.551-564
    • /
    • 2021
  • The use of clean energy based on the hydrogen economy is increasing rapidly due to the greenhouse gas reduction policies and the increase in the need for hydrogen. Currently, South Korea government have been considering a plan to construct hydrogen refueling stations at expressway service area for the purpose of supplying hydrogen vehicles. In the case of a hydrogen refueling stations, a quantitative risk assessment (QRA) must be performed because it includs and uses a high pressurized hydrogen storage tank. In this study, QRA was conducted using societal risk and F-N curve by the consequence assessment (CA) of jet fire and explosion according to the population density, capacity of the high pressurized hydrogen storage tank and frequency assessment (FA) data to the general hydrogen refueling stations systems in expressway service area. In the cases of jet with a leak diameter of 7.16 mm, regardless of expressway service area location, the societal risk was over 1E-04 that was acceptable for as Low As reasonably practicable (ALARP) region (workforce), but unacceptable for ALARP region (public). In the cases of gas explosion, all expressway service area satisfy ALARP region. In the case of the population density is over 0.0727, QRA for constructing the hydrogen refueling stations, must be conducted.

Assessment of London underground tube tunnels - investigation, monitoring and analysis

  • Wright, Peter
    • Smart Structures and Systems
    • /
    • 제6권3호
    • /
    • pp.239-262
    • /
    • 2010
  • Tube Lines has carried out a "knowledge and investigation programme" on the deep tube tunnels comprising the Jubilee, Northern and Piccadilly lines, as required by the PPP contract with London Underground. Many of the tunnels have been in use for over 100 years, so this assessment was considered essential to the future safe functioning of the system. This programme has involved a number of generic investigations which guide the assessment methodology and the analysis of some 5,000 individual structures. A significant amount of investigation has been carried out, including ultrasonic thickness measurement, detection of brickwork laminations using radar, stress measurement using magnetic techniques, determination of soil parameters using CPT, pressuremeter and laboratory testing, installation of piezometers, material and tunnel segment testing, and trialling of remote photographic techniques for inspection of large tunnels and shafts. Vibrating wire, potentiometer, electro level, optical and fibre-optic monitoring has been used, and laser measurement and laser scanning has been employed to measure tunnel circularity. It is considered that there is scope for considerable improvements in non-destructive testing technology for structural assessment in particular, and some ideas are offered as a "wish-list". Assessment reports have now been produced for all assets forming Tube Lines' deep tube tunnel network. For assets which are non-compliant with London Underground standards, the risk to the operating railway has to be maintained as low as reasonably practicable (ALARP) using enhanced inspection and monitoring, or repair where required. Monitoring techniques have developed greatly during recent years and further advances will continue to support the economic whole life asset management of infrastructure networks.

냉동제조 시설의 암모니아 누출사고 위험 분석 (Risk Analysis of Ammonia Leak in the Refrigeration Manufacturing Facilities)

  • 강수진?;이익모;문진영;천영우
    • 한국가스학회지
    • /
    • 제21권1호
    • /
    • pp.43-51
    • /
    • 2017
  • 국내 냉동제조시설에서 암모니아 누출사고가 여전히 발생하고 있음을 볼 수가 있다. 암모니아는 가연성가스 및 독성가스이므로 사고 발생할 때 인체와 생태계에 큰 피해를 일으킬 수 있다. 국내 냉동제조시설의 암모니아 사고유형을 파악한 후 사고시나리오를 선정하여 피해범위를 산정하고 사고 빈도와 위험도를 분석하여 사고 피해를 최소화하는 대책 수립이 필요하다. 본 연구에서는 정량적 위험성 평가(QRA: quantitative risk assessment)의 분석 방법에 따라 암모니아 냉동시스템의 리시버 탱크에 대한 위험도를 분석하였다. 시나리오 분석 조건은 화학물질관리법에서 정하는 '사고시나리오 선정에 관한 기술지침' 및 미국 화학공정안전센터(CCPS: center for chemical process safety)의 가이드라인에 따라 정하였다. DVN사의 SAFETI 프로그램을 활용하여 시나리오에서 선정된 모든 사고 영향범위를 산정하고 빈도 분석을 통하여 리시버 탱크에 대한 위험도를 도출하였다. 빈도 값은 사건수 분석(ETA: event tree analysis)기법과 Part count 기법을 활용하였다. 연구 결과 암모니아 냉동시스템의 개인적 위험도는 7.71E-04/yr으로 도출되었으며, 사회적 위험도 1.17E-03/yr으로 도출되었다. 도출된 위험도는 국제 화재방지협회 (NFPA: national fire protection association)의 ALARP (as low as reasonably practicable) 범위를 적용하여 위험도의 적합성을 확인하였으며, 본 연구에서 제안한 위험도 산정 방법이 사고 피해 최소화 방안을 모색하는데 활용된다면 보다 좋은 결과가 도출될 것으로 판단된다.

정량적 위험성 평가를 활용한 도로터널 화재시 물분무 소화설비의 피난 안전 효과 연구 (A study on use of quantitative risk analysis on life safety performance for the effect of fixed fire fighting system at road tunnel fires)

  • 박경환;유지오
    • 한국터널지하공간학회 논문집
    • /
    • 제14권1호
    • /
    • pp.1-22
    • /
    • 2012
  • 본 논문은 도로터널에 설치하는 물분무소화설비가 피난성능을 개선시키는지를 검증하는 연구이다. 검증의 절차와 방법은 '도로터널 방재시설 설치 및 관리지침'에 따라 수행되었다. 3종류의 화재크기와 27개의 화재시나리오에 대한 화재 평가와 피난 평가를 실시하였다. 결과는 물분무소화설비가 설치된 경우와 설치되지 않은 경우로 구분하여 제시하였다. 물분무소화설비는 27개 시나리오 중에서 26개에서 물분무소화설비가 없는 경우에 비해 사망자가 감소하였다. 물분무소화 설비가 설치되지 않은 경우의 사회적 위험도는 홍콩과 네델란드 기준에서는 수용할 수 없는 범위였다. 반면 물분무소화설비가 있는 경우에는 사회적위험도가 ALARP 범위였다. 결과적으로 물분무소화설비가 있는 경우에는 없는 경우와 비교해서 1명, 10명, 100명 이상의 사망 빈도가 각각 50배, 100배 및 4배로 감소하였다. 결과적으로 물분무소화설비는 도로터널 화재 시 고온기류의 냉각작용과 독성가스의 세척효과를 통해 피난에 유리한 환경을 조성한다는 것을 확인하였다.