• Title/Summary/Keyword: AIR 모델

Search Result 2,267, Processing Time 0.027 seconds

A Study on the Effect of Transformation Leadership on the Job Performance of Employees by AMO Model (AMO모델에 의한 직원의 직무수행에 미치는 혁신적 리더십의 효과에 관한 연구)

  • Li, Nan;Jung, Gi-Young;Kim, Hyung-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.41-50
    • /
    • 2020
  • This paper analyzed leadership behavior and employee performance through empirical analysis method based on AMO theory. In this study, the ability of the leader (A), task motivation (M), and opportunity (O) were chosen as factors to analyze the relationship between transformative leadership and job performance of the subordinate staff, and the self-efficiency (O) and intrinsic motivation (M) were selected at the individual level and team atmosphere (O) at the organizational level to build a research model. 507 valid data were obtained from the survey and statistical analysis was conducted using SPSS23. Studies have shown that transformative leaders have a significant impact on employee performance. This study provides research results of empirical theory to understand the behavior of the leader in the performance of the employees and also suggests implications for the management of the company's human resources.

Numerical Calculation for Input Impedance of a Conductor Located in the Loss Media (손실 매질에 위치한 도체의 입력임피던스 수치계산)

  • Ahn, Chang-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.230-236
    • /
    • 2013
  • This paper presents the numerical calculation for input impedance of a conductor located in the loss media by using the program with MATLAB. The input impedances of the conductor were numerically calculated with the moment of method. To increase an accuracy of results, the Galerkin's method which both the basic function and the weight function are the triangle function was applied. And by applying the modified image method, image sources of the conductor located in air were considered. According to the comparison between the current distributions at the conductor which were calculated with the MATLAB program and the NEC program, the reliability of the self-made program with MATLAB was obtained. In case of the conductor located in soil, which length are 1 m and 2 m, the input impedance were simulated as a function of both a conductivity and a frequency. Finally, input impedances and phases of the conductor located in soil were measured, and those results were compared with simulated results which calculated under the same conditions.

Application of Inactivation Model on Phytophthora Blight Pathogen (Phytophthora capsici) using Plasma Process (플라즈마 공정을 이용한 고추역병균(Phytophthora capsici) 불활성화 모델의 적용)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1393-1404
    • /
    • 2015
  • Ten empirical disinfection models for the plasma process were used to find an optimum model. The variation of model parameters in each model according to the operating conditions (first voltage, second voltage, air flow rate, pH, incubation water concentration) were investigated in order to explain the disinfection model. In this experiment, the DBD (dielectric barrier discharge) plasma reactor was used to inactivate Phytophthora capsici which cause wilt in tomato plantation. Optimum disinfection models were chosen among ten models by the application of statistical SSE (sum of squared error), RMSE (root mean sum of squared error), $r^2$ values on the experimental data using the GInaFiT software in Microsoft Excel. The optimum models were shown as Log-linear+Tail model, Double Weibull model and Biphasic model. Three models were applied to the experimental data according to the variation of the operating conditions. In Log-linear+Tail model, $Log_{10}(N_o)$, $Log_{10}(N_{res})$ and $k_{max}$ values were examined. In Double Weibull model, $Log_{10}(N_o)$, $Log_{10}(N_{res})$, ${\alpha}$, ${\delta}_1$, ${\delta}_2$, p values were calculated and examined. In Biphasic model, $Log_{10}(N_o)$, f, $k_{max1}$ and $k_{max2}$ values were used. The appropriate model parameters for the calculation of optimum operating conditions were $k_{max}$, ${\alpha}$, $k_{max1}$ at each model, respectively.

Numerical Simulation on the Spreading and Heat Transfer of Ex-Vessel Core Melt in a Channel (전산해석을 이용한 원자로 노심 용융물의 노외 거동 및 열전달 특성 분석)

  • Ye, In-Soo;Ryu, Chang-Kook;Ha, Kwang-Soon;Song, Jin-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.425-429
    • /
    • 2011
  • In the unlikely of nuclear reactor meltdown, the leaked core melt or corium must be contained in a device called core-catcher so that the corium can be cooled and stabilized. The ex-vessel behavior of corium involves complex physical and chemical mechanisms of flow propagation, heat transfer, and reactions with sacrificial substrates. In this study, the detailed characteristics of corium flow and heat transfer were investigated by using a commercial CFD code for VULCANO VE-U7 test reported in the literature. The volume-of-fluid (VOF) model was used to predict the interfacial surface formation of corium and the surrounding air, and the discrete ordinate model was adopted to calculate radiation between corium and the surroundings. It was found that cooling via radiation through the top surface of corium had a dominant effect on the temperature and viscosity profiles at the front of the corium flow.

Verification of Computational Fluid Dynamics Model Using Observation Data in Artificial Street Canyon (인공 도로협곡 관측 자료를 활용한 전산유체역학모델 검증)

  • Kim, Do-Hyoung;Hong, Seon-Ok;Lee, Dae-Geun;Lee, Young-Gon;Kim, Baek-Jo
    • Atmosphere
    • /
    • v.26 no.3
    • /
    • pp.423-433
    • /
    • 2016
  • In this study, performance of a computational fluid dynamics (CFD) model is assessed from analysis on air flow pattern which is observed in the artificial street canyon. Field observations focusing on flows were conducted at an artificial street canyon in Magok region. For the observation of three-dimensional airflow structures, twelve three-dimensional wind anemometers (hereafter, CSAT3) were installed inside the street canyon. The street canyon was composed of two rectangular buildings with 35-m length, 4-m width, and 7-m height. The street width (distance between the buildings) is 7 m, making the street aspect ratio (defined by the ratio of building height to street width) of 1. For the observation of above-building wind, a CSAT3 was installed above the northwest-side building. Southwesterly, westerly and northwesterly were dominant in the street canyon during the observations. Because wind direction is parallel to the street canyon in the southwesterly case, westerly and northwesterly were selected as inflow directions in numerical simulations using a computational fluid dynamics model developed through the collaborative research project between National Institute of Meteorological Sciences and Seoul National University (CFD_NIMR_SNU). The observations showed that a well-structured vortex flow (skimming flow) and an evidence of a small eddy at the corner of the downwind building and ground appeared. The CFD_NIMR_SNU reproduced both the observed flow patterns reasonably well, although wind speeds inside the street canyon were underestimated.

The Influence of Natural Smoke Ventilators and Wind Velocities on the Stack effect in High-rise Buildings (배연창 및 외기풍속이 초고층 건축물의 연돌효과에 미치는 영향)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Yeo, Yong-Ju;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.20-26
    • /
    • 2008
  • The performance of natural smoke ventilators in High-rise buildings was analyzed by investigating the stack effect depending on the wind velocities using CONTAMW tool. The results showed that the opening of smoke ventilators can influence on the stack effect in the building thus moving the position of the neutral plane toward the opened smoke ventilators. The outside wind velocities can move up the neutral plane toward the top of the building thus increasing pressure differentials at the bottom of the building. The smoke ventilators can maintain its normal performance without outside wind, however, strong outside wind can prevent natural smoke exhaust due to the infiltration of outside air at the ventilators.

Evaluation of the Economics of High Speed Machining Considering Environmental Effects (환경영향을 고려한 고속절삭가공의 경제성 평가)

  • Chang, Yoonsang;Kim, Sun-Tae
    • Clean Technology
    • /
    • v.12 no.3
    • /
    • pp.182-189
    • /
    • 2006
  • In this study, high speed machining is evaluated with regard to economical and environmental effects. Considering environmental loads, machining costs are analyzed with the mathematical models of machining economics and cutting fluid loss. Data from the tool life experiments of high speed milling and turning are used for the analysis. The analysis of high speed milling shows that the machining cost decreases as increasing the cutting speed. In turning process, the cooling method using cutting fluid shows the minimum machining cost. Considering both machining and environmental costs, cooling method using cold air is superior to other methods.

  • PDF

Theoretical and Computation Analysis on the Pressure Drop in the Cyclone Dust Collector (사이클론 집진장치 내부의 압력강하에 대한 전산해석과 이론식의 결과 비교)

  • Hyun, Daegeun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.263-268
    • /
    • 2014
  • Using the CFD method, the pressure drop in 6 cyclone dust collectors of different shape were calculated. And the results were compared with results of the conventional theories. Equations of Shepherd and Lapple (1939, 1940), First (1950), Alexander (1949), Stairmand (1949), Barth (1956) were used in the theoretical calculation. In CFD calculations, we used standard k-epsilon model for analysis of turbulent flow, fluid is $25^{\circ}C$ air, the velocity at inlet is 10 m/s and the temperature is $25^{\circ}C$. In CFD analysis results, the pressure distributions along the flow showed similar patterns in different cyclone shapes. But the pressure drop distributions estimated on the conventional theories had big difference in different cyclone shapes. Only First's theory and CFD analysis showed similar results.

A Comparatibe on Selection Attributes of Airport throught traditional IPA and revised IPA -Focusing on the Gwangju and Muan Airport-

  • In, Ok-Nam;Park, Eun-Hye
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.11
    • /
    • pp.211-218
    • /
    • 2020
  • Gwangju Airport and Muan International Airport are planned to merge in 2021 while the aviation market is suffering an unprecedented prolonged crisis due to COVID-19 and therefore it is necessary to revitalize the airport to keep up with the passenger's demands. The study conducts an empirical research survey on the passengers of both airports regarding the importance, satisfaction, and overall satisfaction to derive a strategic marketing direction. The results show that to establish a strategic marketing direction, an urgent improvement is required for all "Commercial Facility and Diversity," "Rest Facility and Comfort," "Facilities for the Transportation Vulnerable," "Latest Facility" factors, and "Air Route Diversity." On the other hand, it is required to stop further investing and improving in "Publicity and Marketing" and "Flight Schedule". The results of this study demonstrate academic and practical importance through the comparison of two IPA models, based on Gwangju Airport and Muan International Airport before their integration, to provide substantive and meaningful marketing strategies.

Thermal Performance Analysis of Combined Power Plant Using Coal Gas - Development of the Steady-state Model - (석탄가스를 사용하는 복합발전 플랜트의 열성능 해석 -정상상태 성능해석 모델 개발-)

  • 김종진;박명호;안달홍;김남호;송규소;김종영
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.8-18
    • /
    • 1996
  • As a part of comprehensive IGCC process simulation, the thermal performance analysis was performed for coal gas firing combined power plant. The combined cycle analyzed consisted of il Texaco gasifier and a low temperature gas cleanup system for the gasification block and a GE 7FA gas turbine, a HRSG and steam turbine for the power block. A steady state simulator called ASPEN(Advanced System for Process Engineering) code was used to simulate IGCC processes. Composed IGCC configuration included air integration between ASU and gas turbine and steam integration between gasifier, gas clean up and steam turbine. The results showed 20% increase in terms of gas turbine power output(MWe) comparing with natural gas case based on same heat input. The results were compared with other study results which Bechtel Canada Inc. performed for Nova Scotia power plant in 1991 and the consistency was identified within two studies. As a result, the analysing method used in this study is verified as a sound tool for commercial IGCC process evaluation.

  • PDF