• Title/Summary/Keyword: ACI 설계법

Search Result 29, Processing Time 0.022 seconds

An Analytical Study on the Anchorage Design in Exterior R/C Beam-Column Connections (R/C조 외측 보-기둥 접합부의 정착설계에 대한 해석적 연구)

  • 최기봉
    • Computational Structural Engineering
    • /
    • v.5 no.4
    • /
    • pp.133-142
    • /
    • 1992
  • An analytical model was developed for predicting the pullout behavior of straight beam longitudinal bars anchored at exterior beam-column connections. The model incorporates a local bond constitutive simulation capable of considering the effects of anchored bar diameter, yield strength and the spacing, concrete compressive strength, and column pressure on the bond characteristics of deformed bars in confined conditions of exterior joints. The analytical techniques adopted in this study were shown to satisfactorily predict the results of pullout tests on straight bars embedded in confined concrete specimens. An evaluation of the ACI-ASCE Committee 352 development length requirements in exterior joint conditions was made using the developed analytical approach. The results of this analytical evaluation are indicative of the conservatism of the current development length requirements in the confined conditions of exterior joints.

  • PDF

A Study on the Evaluation of Design Moments of R/C Slab by the Finite Element Method (유한요소법(有限要素法)을 이용한 철근(鐵筋)콘크리트 슬래브의 설계(設計)모멘트 산정에 관한 소고(小考))

  • Lee, Sung Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.3
    • /
    • pp.21-29
    • /
    • 1988
  • Evaluation of accurate design moments in two directions is a primary concern in designing R/C Slab. For this purpose, the use of finite element method utilizing isoparametric plate element is proposed. An example of the simply supported slab shows that the results agree well wth those from elastic plate theory throughout the span. The finite element solutions are also compared with those from equivalent frame method in a flat plate example. It is indicated that the distribution of total moment through the width of design strip using the ACI coefficients is unreasonable. In contrary to this, for the same strip model, the finite element method gives accurate moments in two directions. The proposed method can be applied to any geometric configuration of the slab system, thus the approach is considered to be much advantageous and improved one compared with existing methods.

  • PDF

Analysis of Stratified Rock under Vertical Load in Pile Foundation of Wind Turbine Using Circular Foundation Analysis Method with Equivalent Effective Width (등가유효폭을 가진 원형기초해석법을 이용한 풍력발전기 말뚝기초의 연직하중에 대한 층상암반 해석)

  • Kim, Dohan;Park, Sangyeol;Moon, Kyoungtae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2411-2425
    • /
    • 2013
  • In the design of pile foundation on the rock layer in the stratified structure with sedimentary and rock layers, the structural analysis of the stratified rock layer is required to determine the failure modes (flexural failure, punching shear failure or end bearing failure) and the bearing capacity of the rock layer. However, the existing usable Elastic Plate Analysis Method (EPAM) suggested by ACI committee 436 and Korean Code Requirements for Structural Foundation Design is very complex, and engineers have many difficulties in using it. Therefore, in this research, we proposed the relatively simple Circular Foundation Analysis Method (CFAM) with the concept and the equation of the equivalent effective width (radius) instead of the complex EPM, and the related equations of bending moment and shear force to be equal to the analysis results of EPAM. As a result, the proposed CFAM using the equivalent effective width (radius) is simple and convenient to use, and the analysis results of it are very good in their accuracies comparing those of EPAM and Finite Element Method.

Shear Capacity of Composite Basement Walls (합성 지하벽의 전단성능)

  • 김성만;이성호;서수연;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.3
    • /
    • pp.321-330
    • /
    • 2002
  • This paper presents the experimental results of composite basement wall in which H-pile and reinforced concrete wall are combined using shear connector Twelve specimens are tested to evaluate the shear capacity of the wall. Main variables in the test are composite ratio, distribution of shear connector, thickness of wall, shear-span ratio, and shear reinforcement. Test results indicate that the shear capacity of test specimens varies with the foregoing variables except the composite ratio. The results are compared with strengths predicted using the equations of ACI 318-99, Zsutty, and Bazant. Based on this investigation, a method for predicting the shear strength of composite basement walls is proposed.

Flexural strength of high-strength concrete filled steel tube columns strengthened by carbon fiber sheets (탄소섬유쉬트로 보강한 고강도 콘크리트 충전강관(CFT) 기둥의 휨내력에 관한 연구)

  • Park, Jai-Woo;Hong, Young-Kyun;Hong, Gi-Soup
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.21-28
    • /
    • 2008
  • The CFT (Concrete Filled Steel Tube) columns became popular in high rise building construction due to not only its composite effect but also economic advantage. However, it has been pointed out in various previous researches that the current practice in CFT columns may lead the steel tube to probable local buckling at critical sections of the columns right after yielding. To resolve such a problem, the TR-CFT (Transversely Reinforced Concrete Filled Steel Tube) column is proposed to control or at least delay the local buckling state at the critical section by wrapping the CFT columns with carbon fiber sheet. The validity of the proposed column system is validated through the present paper by observing the experimental performance and comparing it with the analytical prediction of the TR-CFT columns with hish strength concrete. It is also shown that the current design code provisions such as ACI-318, in which the contribution of concrete confining effect filled in steel tube is not appropriately accounted for, may contain too much conservatism.

Ultimate Resisting Capacity of RC Columns Considering P-$\Delta$ Effect (P-$\Delta$ 효과를 고려한 RC 기둥의 극한저항력 산정)

  • 곽효경;김진국;김한수
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.105-116
    • /
    • 2002
  • In this paper, an analytical model to predict the resisting capacity of slender RC columns is introduced. Material and geometric nonlinearities are taken into account, and the layer approach is adopted to simulate the different material properties across the sectional depth. On the basis of the obtained numerical analysis results, an improved design equation as a function of concrete strength, slenderness ratio, steel ratio and eccentricity for slender RC columns, which can be used effectively in the preliminary design stage, is introduced. Finally, P-M interaction diagrams constructed by the introduced equation are compared with the ACI method with the objective of establishing the relative efficiencies of the introduced equation.

Effective Beam Width for Flat-Plate Systems Having Edge Beams under Lateral Loads (수평하중을 받는 테두리보가 있는 플랫플레이트 시스템의 유효보폭계수)

  • Han, Sang-Whan;Cho, Ja-Ock;Park, Young-Mi
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.213-219
    • /
    • 2008
  • The purpose of this study is to propose frame analysis method for flat plate slabs having edge beam under lateral loads. Flat plate system is defined as the system only with slab of uniform thickness and column. However, the slab system generally incorporate edge beams at exterior connection in actual design. ACI 318 (2005) allows three methods for conducting flat plate system analysis subjected to lateral loads. There are the finite element method (FEM), the equivalent frame method (EFM), and the effective beam width method (EBWM). Among methods, the EBWM enables us to analyze practically by substituting the actual slab to beam element. In this model, the beam element has a thickness equal to that of the slab, and effective beam width equal to some fraction of the slab transverse width. However, the established EBWM was generally proposed for variables of geometry or stiffness reduction factor and seldom proposed for the effect of edge beams. This study verifies that, in the case of flat plate system having edge beams at exterior connections, the lateral stiffness is considerably larger than without edge beams. Therefore it need to analysis method for considered the effect of edge beams. In this study, an analysis model is proposed for the flat plate system having edge beams under lateral loads by considering the effect of edge beams. To verify the accuracy of proposed model, this study compared results of the proposed EBWM with results of FEM of flat plate systems having edge beams under lateral loads. Also, the proposed approach is compared with experimental results of former research.

Drying Shrinkage of Concretes according to Different Volume-Surface Ratios and Aggregate Types (형상비 및 골재의 종류에 따른 콘크리트 시편의 건조수축특성 연구)

  • Yang, Sung-Chul;Ahn, Nam-Shik;Choi, Dong-Uk;Kang, Seoung-Min
    • International Journal of Highway Engineering
    • /
    • v.6 no.4 s.22
    • /
    • pp.109-121
    • /
    • 2004
  • This study was performed to investigate the characteristics of drying shrinkage for concrete slabs as a project for Korean pavement design procedure. According to the volume-surface ratios and aggregate types, the experiments have been executed for 252 days. In order to simulate the volume-surface ratio of a real concrete pavement slab, three-layer epoxy coating and wrapping were used to prevent the evaporation at the part of specimen surfaces. As a result of preliminary test, coating and wrapping method was identified as reliable for three months. According to the volume-surface ratio, the drying shrinkage of the concrete specimen using sandstone was measured 1.32 to 1.8 times higher than that of the limestone specimen. Comparing to the measured drying shrinkage strains and established ACI and CEB-FIP model equations, it turned out that those model equations were underestimated. Finally, considering the age and volume-surface ratios, the prediction equations of the drying shrinkage of concrete specimen were proposed through a multiple nonlinear regression analysis.

  • PDF

State-of-the-Art Research on the Reinforced Concrete Walls (철근콘크리트 벽체의 국내.외 연구동향)

  • Yun, Hyun-Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.875-878
    • /
    • 2008
  • This paper summarizes on the state-of-the-art research on the reinforced concrete (RC) walls for evaluating and predicting the performance of RC walls analytically and experimentally. A brief discussion of the research trends is presented to propose the further research direction of RC walls. In the paper, 102 papers published on the ACI, Engineering Structure, KCI journal, and AIK journal are collected and reviewed.

  • PDF