• Title/Summary/Keyword: ACI 모델

Search Result 127, Processing Time 0.026 seconds

A Evaluation on the Field Application of High Strength Concrete for CFT Column (고강도 CFT용 콘크리트의 현장적용성 평가 및 장기거동 예측)

  • Park, Je Young;Chung, Kyung Soo;Kim, Woo Jae;Lee, Jong In;Kim, Yong Min
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.707-714
    • /
    • 2014
  • CFT (Concrete-Filled Tube) is a type of steel column comprised of steel tube and concrete. Steel tube holds concrete and the concrete inside tube takes charge of compressive load. This study presents structural performance of the CFT column which has 73~100 MPa high strength concrete inside. Fluidity, mechanical compression, pump pressure test in flexible pipe were conducted for understanding properties of the high strength concrete. Material properties were achieved by various experimental tests, such as slump, slump flow, air content, U-box, O-Lot, L-flow. In addition, mock-up tests were conducted to monitor concrete filling, hydration heat, compressive strength. From construction sites in Sang-am dong and University of Seo-kang, long-term behaviors could be effectively predicted in terms of ACI 209 material model considering elastic deformation, shrinkage and creep.

Study on the Quality Characteristics of High-strength Concrete Using LCD Industrial Waste (LCD 산업부산물을 이용한 고강도 콘크리트의 품질 특성에 관한 연구)

  • Kim, Dong-Jin;Park, Seung-Hee;Choi, Sung;Han, Yang-Su
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.650-657
    • /
    • 2021
  • Alkali activators that stimulate mineral compounds are expensive materials, but in order to replace industrial products of high alkali in gredien ts, both product an d econ omic feasibility must be satisfied. In this study, alkali in dustrial waste(LW) from the LCD man ufacturin g process were used for the purpose of alkali active reaction of GGBFS for high stren gth concrete over 50MPa. Concrete mixed with LW had reduced workability, but it had the characteristic of increasing compressive strength. Analysis using ACI 209 Compressive Strength Model Equation was made to compare the changes in strength coefficients according to LW mixing. The durability test of concrete, such as Chloride Penetration Resistance and carbonation resistance, also showed excellent performance. In the Adiabatic temperature rise test results, the concrete mixed with LW had the effect of accelerating the initial hydration heat. However, the final Adiabatic temperature rise was not significantly affected by the mixing of LW.

Comparison of Bond-Slip Behavior and Design Criteria of High Strength Lightweight Concrete with Compressive Strength 50 MPa and Unit Weight 16 kN/m3 (압축강도 50 MPa, 단위중량 16 kN/m3 고강도 경량 콘크리트 부착-슬립 거동의 설계기준과의 비교)

  • Lee, Dong-Kyun;Lee, Do-Kyung;Oh, Jun-Hwan;Yoo, Sung-Won
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.2
    • /
    • pp.168-175
    • /
    • 2022
  • With the recent development of nanotechnology, its application in the field of construction materials is continuously increasing. However, until now, studies on the bond characteristics of concrete and rebar for applying high-strength lightweight concrete with a compressive strength of 50 MPa and a unit weight of 16 kN/m3 to structural members are lacking. Therefore, in this paper, 81 specimens of high-strength lightweight concrete with a compressive strength of 50 MPa and a unit weight of about 16 kN/m3 were fabricated and a direct pull-out tests were performed. The design code for the bond strength of ACI-408R and the experimental results are shown to be relatively similar, and as a result of the CEB-FIP and modified CMR bond behavior models through statistical analysis, it is shown to describe well on average.

Prediction of Flexural Capacity of Steel Fiber-Reinforced Ultra High Strength Concrete Beams (강섬유 보강 초고강도 콘크리트 보의 휨강도 예측기법의 제안)

  • Yang, In Hwan;Joh, Changbin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.317-328
    • /
    • 2010
  • The method to evaluate the flexural capacity of steel fiber-reinforced ultra high strength concrete beams was proposed in this study. An experimental program was set up and fourteen beams have been tested. Test results were compared with predictions by design code and by the proposed method, respectively. It was found that predictions by using ACI 544 Committee recommendations considerably underestimate the flexural capacity. Underestimation of flexural capacity resulted from that of tensile stress block. Three-point bending test data of notched prism specimens and their inverse analysis results were incorporated into modeling of tension stress block. The ratio of the predicted to the experimental flexural capacity was in the range of 0.98 to 1.14. The present study represents that the proposed method allows more realistic prediction of flexural capacity of steel fiber-reinforced ultra high strength concrete beams.

Reversed Cyclic Load Tests on Deep Beam-and-Exterior Column Joints (깊은보-외부기둥 접합부의 반복 횡하중 실험)

  • Ko, Dong-Woo;Lee, Han-Seon
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.265-273
    • /
    • 2007
  • The most common structural system for apartment buildings in Korea is adopted to combine structural systems: for example, a moment-resisting frame will be used for lower stories and bearing wall system for the upper stories. This type of buildings have soft and/or weak stories in lower stories, and it may lead to collapse of those buildings during the large earthquake. Reversed cyclic load tests were conducted to estimate the performance and behavioral characteristics of deep beam and exterior column Joints. Experimental parameter is the amount of transverse reinforcement (designed by ACI code and Sheikh's procedure). The results of this study are as follows: (1) The required transverse reinforcement of column designed by Sheikh's procedure requires 2.9 times larger than that designed by ACI procedure. Large amount of transverse reinforcement increase the ductility of the column. (2) Most of the lateral drift in the column is due to the flexural deformation in the joint and plastic hinge region and up-lift rotation. (3) Transverse reinforcement in the exterior column shall be required not only in the hinge region but also in the joint.

Modelling of Drying Shrinkage for Different Environmental Conditions (환경인자를 고려한 건조수축의 예측모델 개발)

  • 한만엽
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.1
    • /
    • pp.111-120
    • /
    • 1996
  • Drying shrinkage is a very important properties of concrete, which is affected by environmental conditions. The environmental conditions are temperature, relative humidity, and wind speed, which is quite variable and its effct on drying shrinkage is quite complex, too. In this study, environmental effects on drying shrinkage wrer integrated into one variable-evaporation rate. In several different environmental conditions, evaporation rate was measured with Evaporometer and compared with PCA chart, and also compared with measured drying shirnkage to verify the possibility of being a single parameter. The results are summarized in a prediction chart and prediction equation for drying shrinkage.

Model Equation for Shear Strength of Reinforced Concrete Beams without Web Reinforcement (전단보강근이 없는 철근콘크리트 보의 전단강도 예측 모델식 제안)

  • 김진근;박연동
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.04a
    • /
    • pp.124-129
    • /
    • 1993
  • In this study, a simple and accurate model equation for prediction of shear strength of reinforce concrete beams without web, reinforcement is proposed based on basic shear transfer mechanism and modified Bazant's size effect law. The proposed equation includes the effects of concrete strength, longitudinal steel ratio, shear span to depth ratio and effective depth. Comparisons with published experimental data indicate that the proposed equation estimates properly the effects of these factors. Among many equations, ACI code equation, Zsutty's equation and Bazant's equation are selected for comparison. As the result, the accuracy of the proposed equation is better than that of any other equations.

  • PDF

초기설계 및 선박 유체 성능 해석 시스템

  • 이동곤;공도식;강국진;김연규;서성부
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.30 no.4
    • /
    • pp.14-17
    • /
    • 1993
  • 본 연구는 CSDP-초기설계 시스템 개발'3' 세부과제로 수행되었으며 선박의 기본 성능 및 사양을 결정하는데 필요한 제반 기본 계산을 수행하고 설계자의 의사결정을 지원하는 대화식 초기 설계 전산 시스템의 개발에 그 목적이 있으며, 크게 개념설계 분야와 선형 설계분야로 나누어 개발 되어왔다.(Fig. 4.1 참조). 이번 4차년도에는, 프로그램을 보다 효율적으로 사용할 수 잇도록 하기 위하여 개년설계 시스템을 구성하는 단위 모듈들을 단독으로 사용 가능하도록 독립성을 유지 함과 동시에, 시스템 차원의 상위 레벨에서 각각의 모듈들을 통합 제어하는 수퍼어플리케이션 개념을 이용한 유연화된 대화형 개념설계 프로그램(BASCON-3)을 개발하였다. 그리고 선박의 주기관 선정과 관련한 경험적 지식을 도출하여 지식베이스를 구성하고, 주기관 데이터베이스 및 저항.추진성능 추정 모듈들과의 통합을 통한 시험형의 주기관 선정 지원 시스템(ME-ASSIST )을 개발하였다. 또한 그래픽 사용자 인터페이스(GUI)를 채택한 확장형 선형 정의 및 변환 프 로그램(MBASTRANS)을 개발하였다. 형상 모델러인 ACIS를 도입하여, 조선 분야에의 활용 가 능성을 연구하였고, 조선소에 GUI개발 기술과 시스템 통합 기술을 이전하였다.

  • PDF

An Experimental Study on the Prediction Model for the Compressive Strength of Concrete with Blast Furnace Slag by Maturity Method (고로슬래그미분말 혼입 콘크리트의 적산온도를 이용한 강도예측모델에 관한 실험적 연구)

  • Yang, Hyun-Min;Cho, Myung-Won;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.107-108
    • /
    • 2012
  • The study on the strength prediction using Maturity is mainly focused on, but the study on the concrete mixing blast furnace slag powder is insufficient. The purpose of this study is to investigate the relationships between compressive strength and equivalent age by Maturity function and is to compare and examine the strength prediction of concrete mixing Blast Furnace Slag Power using ACI and Logistic Curve prediction equation. So it is intended that fundamental data are presented for quality management and process management of concrete mixing Blast Furnace Slag Power in the construction field.

  • PDF

Ultimate Strength Analysis of Reinforced Concrete Corbels Using Grid Softened Strut-Tie Model (격자 연화 스트럿-타이 모델 방법을 이용한 RC 코벨의 극한강도예측)

  • Yun Young Mook;Kim Byung Hun;Lee Won Seok;Shin Hyo Jung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.544-547
    • /
    • 2004
  • Predicting the failure modes of reinforced concrete corbels is difficult because the reinforced concrete corbels show the shapes of sudden shear failures at even slight deflection. For this reason, an exact analysis method is demanded highly. In this study, the validity of the grid softened strut-tie model method suggested for concrete member analysis was examined through the ultimate strength evaluation of the reinforced concrete corbels tested to failure. The evaluated ultimate strengths by the grid softened strut-tie model method were compared with those by the ACI 318-02 and the softened strut-tie model method.

  • PDF