고온 초전도 tape의 임계전류 저하에 따른 교류손실 특성 (AC loss Characteristics under Critical Current Degradation of HTS Tapes)

  • 김해준;조전욱;김재호;심기덕;곽동순;배준한;김해종;성기철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.29-33
    • /
    • 2005
  • Critical current$(I_c)$ degradation of High $T_c$ Superconducting(HTS) tapes and AC loss under mechanical load is one of the hottest issues in HTS development and application. Mechanical load reduces the critical current of superconducting wire, and the $I_c$ degradation affects the AC loss of the wire. We measured the $I_c$ degradation and AC loss under tension and bending of Bi-2223 tapes made by 'Powder-in-Tube' technique at 77K with self-field. Also, we have studied the frequency characteristics on self-field AC loss in multi-filamentary Bi-2223/Ag tape at 77K. The measurement results and discussions on the relationship between $I_c$ degradation and AC loss are presented.

고온 초전도체의 임계전류 저하에 따른 교류 손실 특성 (Ac Loss Characteristics under Critical Current Degradation of HTS Tapes)

  • 김해준;김재호;심기덕;조전욱;곽동순;김해종;성기철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.286-287
    • /
    • 2005
  • Critical current(Ic) degradation of HTS tapes and AC loss under mechanical load is one of the hottest issues in HTS development and application. Mechanical load reduces the critical current of superconducting wire, and the Ie degradation affects the AC loss of the wire. We measured the Ie degradation and AC loss under tension and bending of Bi-2223 tapes processed by "Powder-in-Tube" technique at 17K with self-field. And we have studied the frequency dependence of self-field AC loss in multi-filamentary Bi-2223/Ag tape at 77K. The measurement results and discussions on the relationship between Ic degradation and AC loss are presented.

  • PDF

열량법을 이용한 소용량급 고온초전도 마그넷의 교류손실 측정 (Experimental Set-up for AC Loss in Small Scale HTS Manget by using Calorimetric Method)

  • 박세웅;장대희;강형구;배덕권;김태중;윤용수;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1315-1317
    • /
    • 2005
  • Generally, the high Tc superconductor(HTS) doesn't generate any loss in DC condition, but generate considerable loss in AC condition. Until now AC loss in superconductor has been researched on measuring method of short sample by using electrical method and magnetization method. But it is not easy to estimate AC loss in high class magnet system with results of measuring AC Joss in short sample. In this paper, we carry out research on measuring method by using calorimetric method used in measuring AC loss in high class magnet system. We make the inductive and non-inductive superconducting magnet and measure the generated AC loss, then we compare the measured results with the calculated results using Norris equation. This measuring method of AC loss using calorimetric method can measure not only AC loss in superconducting magnet but losses in conducting, radiant and low temperature. Consequently it is thought that efficient design and fabrication of superconducting magnet system will be possible by means of AC loss measurement method using calorimetric method.

  • PDF

AC Loss Measurement and Analysis of Ag-sheathed Bi-2223 Conductors in Terms of Eddy Currents and Flux Creep

  • Jang, Mi-Hye
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권6호
    • /
    • pp.211-215
    • /
    • 2003
  • Alternating current (AC) losses of two Bi-2223 ([Bi, Pb] : Sr : Ca : Cu :O = 2:2:2:3) tapes [one untwisted (Tape I, twist-pitch of $\infty$ mm) and the other with a twist-pitch of 8mm (Tape II) ] were measured and compared. These samples, produced by the powder-in-tube (PIT) method, are multi-filamentary and have a Ag/Au and Ag matrix, respectively. Susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation.

A Study of Characteristic of Electrical-magnetic and Neutron Diffraction of Long-wire High-superconductor for Reducing Energy Losses

  • Jang, Mi-Hye
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권6호
    • /
    • pp.265-272
    • /
    • 2008
  • In this paper, AC losses of long wire Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist. The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-prob method. And the Magnetic measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O).

Coated Conductor의 굽힘변형에 따른 임계전류 및 교류손실 특성 (Critical current and AC loss characteristic of Coated Conductor under bending)

  • 김해준;심기덕;김석호;조전욱;장현만;이수길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권3호
    • /
    • pp.23-26
    • /
    • 2008
  • Constructions of coated conductor which is differently from Bi-2223 is comprised multiple coatings on a base material or substrate and designed to achieve the highest degree of alignment possibility of the atoms in the superconductor material. In this study, we are measured and analyzed degradations of critical current according to diameter. In addition to study the effects of bending strain, we observed the AC loss of coated conductor and carried out analytical study for relation between Ic degradation and AC loss as well. The measurement of AC loss and numerical calculation was carried out based on Norris theory to compare with experimental results. The relationship between critical current and AC loss of HTS tapes with partial deformation by mechanical stress was studied. These results will amount the most important basis data in the of HTS cable, magnet, etc that winding work is required.

적층 배열형상에 따른 BSCCO 적층선재의 자화손실 특성 수치해석 및 측정 (Numerical Analysis and Measurement of Magnetization Loss in BSCCO Multi-stacked Conductor According to Stacking Geometry)

  • 박명진;임형우;이광연;차귀수;이지광
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권2호
    • /
    • pp.83-88
    • /
    • 2006
  • AC loss is one of the main research area in AC power application using high temperature superconductor(HTS), such as HTS transformer, HTS current limiter and HTS cable, because it is closely related to efficiency, economic estimation and design of power device. A lot of research for various arrangements of HTS tapes have been performed to increase a capacity of transport current because single HTS tape can not satisfy the demanded current capacity in HTS power application. In this paper, we studied magnetization loss by different several arrangements of BSCCO tapes such as Edge-to-Edge type, Face-to-Face type and Matrix type through numerical analysis by 2D-FEM and measurement. As a result, we got the result that the magnetization loss of Face-to-Face type arrangements was lower than those of other arrangement types under the conditions of the same stacking number. We think that the result was due to shield effect by demagnetization of adjacent HTS tapes which are located face to face.

교류 임피던스 측정법을 이용한 고분자 전해질 연료전지의 성능특성 분석 (Performance Analysis of Polymer Electrolyte Membrane Fuel Cell by AC Impedance Measurement)

  • 서상헌;이창식
    • 한국수소및신에너지학회논문집
    • /
    • 제20권4호
    • /
    • pp.283-290
    • /
    • 2009
  • This study focuses on the performance characteristics of polymer electrolyte membrane fuel cell (PEMFC) using the AC impedance technique. The experiment was carried out to investigate the optimal operating conditions of PEMFC such as cell temperature, flow rate, humidified temperature and back-pressure. The fuel cell performance was analyzed by DC electronic-loader with constant voltage mode and expressed by voltage-current density. Additionally, AC impedance was measured to analysis of ohmic and activation loss and expressed by Nyquist plot. The results showed that the cell performance increased with increase of cell temperature, air flow rate, humidified temperature and backpressure. Also, the activation loss decreased as the increase of cell temperature, air flow rate, humidified temperature and backpressure.

교류저항 측정시스템 개발 (Development of AC Resistance Measurement System)

  • 김한준;유광민;강전홍;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.683-684
    • /
    • 2008
  • The resistance is frequency dependent by the Seeback effect, loading effect, Eddy current loss, uniformly distributed inductance of the resistance element and uniformly distributed self-capacitance of the resistance element and capacitance between resistance element and it's box. A precise ac resistance measurement system has been developed for using as maintaining and dissemination of national ac resistance standards. The developed resistance measurement system can be used as a instrument of national ac resistance standards at frequency less than 10 kHz and it's measurement accuracy was 0.23(${\mu}{\Omega}/{\Omega}$)+4.2 ${\mu}{\Omega}$ at 1592 Hz and 20 V.

  • PDF

Coated Conductor를 사용한 무유도 팬케이크형 한류 코일의 통전 손실 특성 (Transport Loss Characteristic of the Bifilar Pancake Type Fault Current Limiting Coil using Coated Conductor)

  • 박동근;방주석;양성은;안민철;심기덕;윤용수;남관우;석복렬;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.21-25
    • /
    • 2007
  • Superconducting fault current limiter (SFCL) is attractive apparatus to reduce fault current in power grid. Since it is applied to the alternating current (AC) power line, the SFCL has losses in the normal operation. Recently, coated conductor (CC) is noticeable material employed for resistive bifilar winding type SFCL in many research groups. Bifilar structure is expected to have low AC loss by magnetic field offset as compared with the single tape structure in the same length. This paper reports about characteristic of bifilar pancake type coil for SFCL application in AC loss aspect. The bifilar coil is wound using CC with facing on HTS sides each other. Transport AC loss measurement and characteristic analysis of the bifilar coil using CC have been performed at 77K. The test results are compared with the Norris equations and the test results of non-inductively wound paralleled solenoid type coil which is suggested and tested in this group at present.