• Title/Summary/Keyword: AC Losses Calculation

Search Result 19, Processing Time 0.035 seconds

AC Losses of the HTS Pancake Coil by Using Electric Method (전기적 측정법을 사용한 팬케이크 코일에서의 교류손실 측정)

  • 이승욱;임형우;최명섭;이희준;차귀수;이지광
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.37-40
    • /
    • 2003
  • This paper presents calculated and measured AC losses of the HTS pancake coil. Magnetic field in the HTS coil under operating conditions was calculated by FEM. Results of measured ac loss in 4-stacked short sample were used in the AC loss calculation. Various methods, such as, electric method, calorimetric method, wattmeter method, were used to measure the AC loss.

  • PDF

Analysis of AC Losses in HIS Transformer with Double Pancake Windings (초전도 변압기 교류 손실 해석)

  • Kim Jong-Tae;Kim Woo-Seok;Kim Sung-Hoon;Choi Kyeong-Dal;Joo Hyeong-Gil;Hong Gye-Won;Han Jin-Ho;Lee Hee-Gyoun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.1
    • /
    • pp.17-21
    • /
    • 2005
  • AC loss is one of the important parameters in HTS (High Temperature Superconducting) AC devices. Among the HTS AC power devices, the transformer is the essential part in the electrical power system. But unfortunately, the transformer is the worst HTS device concerning AC loss because of very large magnetization loss due to high magnetic field applied to the HTS wire. We calculated the magnetization losses in HTS pancake windings for transformer according to the operating temperature. Two kinds of arrangement of HTS pancake windings were adopted for calculation of AC losses of a shell type transformer, and the analysis results were presented and discussed.

Calculation of AC Losses by Perpendicular Magnetic Field (수직방향 자장에 의한 교류손실 계산)

  • 이승욱;심정욱;차귀수;이지광
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.172-175
    • /
    • 2001
  • AC loss which is generated in an HTS wire varies with the direction of the external magnetic field. This paper calculates the AC loss in an HTS tape, where effects of the perpendicular direction of the magnetic field are considered. Brandt equation is used to calculate the loss by perpendicular magnetic field. In the calculation, current densities are varied along the variation of the magnitude of the external magnetic field. Results of calculation are compared with those of the conventional method.

  • PDF

Numerical Calculation of AC transport current loss of stacked BSCCO wires (수치해석을 이용한 BSCCO 적층 선재들에 교류 통전시 발생하는 손실 계산)

  • Lim, Hyoung-Woo;Han, Byung-Wook;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.56-58
    • /
    • 2007
  • AC transport current losses is an important factor in the development of superconducting tapes and superconducting power applications. In this paper we compared measurement, calculation and Norris equation of AC transport current loss in BSCCO single and multi stacked wire. And present a distribution flux density and current density in the HTS single wire and multi stacked wire. The result of Measurement and calculation of Ac transport current loss show that the same. And show that HTS characteristic of inside HTS wire.

  • PDF

Analysis of AC Losses in HTS Transformer with Double Pancake Windings (초전도 변압기 교류 손실 해석)

  • Kim Jong-Tae;Kim Woo-Seok;Kim Sung-Hoon;Choi Kyeong-Dal;Joo Hyeong-Gil;Hong Gye-Won;Han Jin-Ho;Lee Hee-Gyoun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.812-814
    • /
    • 2004
  • AC loss is one of the important parameters in (High Temperature Superconducting)HTS AC devices. Among the HTS AC power devices, the transformer is the essential part in the electrical power system. But unfortunately, the transformer is the worst HTS device concerning AC loss because of very large magnetization loss due to high magnetic field applied to the HTS wire. We calculated the magnetization losses in HTS pancake windings for transformer according to the operating temperature. Two kinds of arrangement of HTS pancake windings were adopted for calculation of AC losses of a shell type transformer, and the analysis results were presented and discussed.

  • PDF

An Improvement On-Line Failure Diagnosis of DC Link Capacitor in PWM Power Converters (PWM 전력 컨버터에서 DC 링크 커패시터의 개선된 온라인 고장 진단)

  • Shon, Jin-Geun;Na, Chae-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • DC link electrolytic capacitors are widely used in various PWM power converter system, such as adjustable speed driver(ASD) or DC/DC converter. Electrolytic capacitors, which is the most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. This objective of this paper is to propose a improvement method to detect the rise of equivalent series resistor(ESR) in order to realize the online failure prediction of electrolytic capacitor for DC link of PWM power converter. The ESR detection scheme is based on the determination of the electrolytic capacitor AC losses calculated from voltage/current measurement using AC coupling. Therefore, the preposed online failure prediction method has the merits of easy ESR computation and circuit simplicity compare with BPF method. Simulation results show the veridity of the proposed on-line ESR estimation method.

Loss Analysis and Air-Cooled Design for a Cascaded Electrical Source Transmitter

  • Xue, Kai-Chang;Wang, Shuang;Lin, Jun;Li, Gang;Zhou, Feng-Dao
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.530-543
    • /
    • 2015
  • Air-cooling method is adopted on the basis of the requirements for the thermal stability and convenient field use of an electrical source transmitter. The power losses of the transmitter are determined after calculating the losses of the alternating current (AC)-direct current (DC) power supply, the constant-current circuit, and the output circuit. According to the analysis of the characteristics of a heat sink with striped fins and a fan, the engineering calculation expression of the Nusselt number and the design process for air-cooled dissipation are proposed. Experimental results verify that the error between calculated and measured values of the transmitter losses is 12.2%, which meets the error design requirements of less than 25%. Steady-state average temperature rise of the heat sink of the AC-DC power supply is $22^{\circ}C$, which meets the design requirements of a temperature rise between $20^{\circ}C$ and $40^{\circ}C$. The transmitter has favorable thermal stability with 40 kW output power.

Practical Bifurcation Criteria considering Inductive Power Pad Losses in Wireless Power Transfer Systems

  • Kim, Minkook;Lee, Jae-Woo;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.173-181
    • /
    • 2017
  • In this paper, the bifurcation criteria for inductive power transfer (IPT) systems is suggested considering the inductive power pad losses. The bifurcation criteria for series-series (SS) and series-parallel (SP) topologies are derived in terms of the main parameters of the IPT system. For deriving precise criteria, power pad resistance is obtained by copper loss calculation and core loss analysis. Utilizing the suggested criteria, possibility of bifurcation occurrence can be predicted in the design process. In order to verify the proposed criteria, 50 W IPT laboratory prototype is fabricated and the feasibilities of the switching frequency and AC load resistance shift to escape from bifurcation are identified.

Study on the Calculation of the Optimal Power Operation Considering Line Contingencies (상정사고를 고려한 전력계통 최적운용에 관한 연구)

  • 박영문;백영식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.6
    • /
    • pp.241-246
    • /
    • 1984
  • The power system scheduling process is formulated as an optimization problem with linear inequality constraints. AC Loadflow method is used for the problem solution and line losses are considered. The constraints under consiceration are generator power limits, load schedding limits and line capacity limits. In solving the objective function the Dual Relaxation method is adopted. Tests indicate that the method is practical for real time applications.

  • PDF

The study on the DC Ic measurement and AC loss in the 22.9kV, 50MVA HTS power cable (22.9kV/50MVA급 고온초전도 전력케이블의 DC Ic 측정 및 교류손실에 관한 연구)

  • Choi, Suk-Jin;Lee, Sang-Jin;Sim, Ki-Deok;Cho, Jeon-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.808-809
    • /
    • 2008
  • 22.9kV 50MVA HTS power cable has been developed and tested by Korea Electrotechnology Research Institute and LS Cable Company and it was supported by a grant from Center for Applied Superconductivity Technology of the 21st Century Frontier R&D Program. In this paper, DC Ic of 100m HTS cable which is installed at Kochang testing station was measured and analyzed. A measurement technique of DC Ic used by resistance and inductance removal method is established. The HTS power cable is composed of 2 layers for transmission and 1 layer for shield. For the analysis of AC losses in an HTS power cable, 2-dimensional numerical calculation was carried out to define the magnetic field distribution. We calculated the magnetization losses in the HTS core of that cable from these fields. These calculated results are in accordance with those of experiment.

  • PDF