• Title/Summary/Keyword: AC/A ratio

Search Result 490, Processing Time 0.024 seconds

A Modified Ramp Reset Waveform for High Contrast Ratio in AC PDPs

  • Kim, Jae-Sung;Yang, Jin-Ho;Ha, Chang-Hoon;Whang, Ki-Woong
    • Journal of Information Display
    • /
    • v.3 no.4
    • /
    • pp.13-18
    • /
    • 2002
  • In general, the background light that is produced during the reset period deteriorates the dark room contrast ratio in AC PDP. In this paper, we propose a modified ramp reset pulse that can reduce the background light to an imperceptible level. In the new reset waveform, the discharges between the scan and sustain electrodes are minimized by applying a positive bias voltage to the sustain electrode and only the weak discharges between the scan and address electrodes are found to occur during the reset period. We also adopted the MgO coated phosphor layer to improve the address voltage margin that was reduced when the bias voltage in the modified ramp reset waveform was applied. As a result, the address voltage margin of 45 V which is the same level of the conventional method was ortained and the dark room contrast ratio was improved up to 7500 : 1.

The Change of the Near Eye Position according to the Spectacle and Contact Lens Wearing (안경과 콘택트렌즈 착용에 따른 근거리안위의 변화)

  • Han, Sun-Hee;Kim, Bong-Hwan;Kim, Hak-Jun;Park, Jun-Sung;Park, Hae-Been;Kim, Mi-Jeong;Park, Ju-Hyeong;Kim, Jin-Sol;Lee, Kyeong-Hoon;Kim, Jong-Hwan;Ha, Na-Ri
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.4
    • /
    • pp.435-443
    • /
    • 2015
  • Purpose. This study was to investigate comparison of the near eye position according to the spectacle and contact lens wearing. Methods. We measured the AC/A ratio and near horizontal phoria using modified Thorington method in each case spectacle and contact lens wearing of equivalent spherical power after measuring the full corrected diopter for 20 subjects (men 5, woman 15, $21.15{\pm}1.35$ years) without specific ocular diseases, ocular surgery experience and vision anomalies. Results. It was shown high correlation between spectacle and contact lens wearing as AC/A ratio is a correlation coefficient 0.99 (p=0.00), near horizontal phoria is a correlation coefficient 0.95 (p=0.00). And contact lens wearing increased as AC/A ratio by $0.32{\pm}1.35$ ${\Delta}/D$ (p=0.31) and near horizontal phoria by $-0.17{\pm}2.18$ ${\Delta}$ (p=0.73) than spectacle wearing but there was no statistically significant difference. As the higher myopic grade AC/A ratio increased and then was shown decreased tendency in -6.00 D < $SED{\leq}-4.00$ D group (p>0.05) and as the higher myopic grade near exophoria increased but there was no statistically significant difference (p>0.05). Conclusions. We should consider that the subjects who had the lower AC/A ratio or higher near exophoria in -6.00 D < $SED{\leq}-4.00$ D group were necessary to measure AC/A ratio and near horizontal phoria when they were wearing contact lens because contact lens wearing tended to increase the near exophoria than spectacle wearing.

Improvement and Validation of an Overlay Design Equation in Seoul (서울형 포장설계식 개선 및 검증)

  • Kim, Won Jae;Park, Chang Kyu;Son, Tran Thai;Phuc, Le Van;Lee, Hyun Jong
    • International Journal of Highway Engineering
    • /
    • v.19 no.5
    • /
    • pp.49-58
    • /
    • 2017
  • PURPOSES : The objective of this study is to develop a simple regression model in designing the asphalt concrete (AC) overlay thickness using the Mechanistic-empirical pavement design guide (MEPDG) program. METHODS : To establish the AC overlay design equation, multiple regression analyses were performed based on the synthetic database for AC thickness design, which was generated using the MEPDG program. The climate in Seoul city, a modified Hirsh model for determining dynamic modulus of asphalt material, and a new damaged master curve approach were used in this study. Meanwhile, the proposed rutting model developed in Seoul city was then used to calibrate the rutting model in the MEPDG program. The AC overlay design equation is a function of the total AC thickness, the ratio of AC overlay thickness and existing AC thickness, the ratio of existing AC modulus and AC overlay modulus, the subgrade condition, and the annual average daily truck traffic (AADTT). RESULTS : The regression model was verified by comparing the predicted AC thickness, the AADTT from the model and the MEPDG. The regression model shows a correlation coefficient of 0.98 in determining the AC thickness and 0.97 in determining AADTT. In addition, the data in Seoul city was used to validate the regression model. The result shows that correlation coefficient between the predicted and measured AADTT is 0.64. This indicates that the current model is more accuracy than the previous study which showed a correlation coefficient of 0.427. CONCLUSIONS:The high correlation coefficient values indicate that the regression equations can predict the AC thickness accurately.

Geographical Variation in Sex Pheromone Composition of Adoxophyes spp. (Lepidoptera: Tortricidae) in Pear Orchards (배 과원에 발생하는 애모무늬잎말이나방 성페로몬 조성의 지리적 변이)

  • Yang Chang-Yeol;Jeon Heung-Yong;Boo Kyung-Saeng
    • Korean journal of applied entomology
    • /
    • v.44 no.1 s.138
    • /
    • pp.31-36
    • /
    • 2005
  • Adoxophyes spp. are the major rests of a pear. The larvae attack both leaves and fruits. (Z)-9-tetradecenyl acetate (Z9-14:Ac), (Z)-11-tetradecenyl acetate (Z11-14:Ac), (E)-11-tetradecenyl acetate (E11-14:Ac) and 10-methyldodecyl acetate (10me-12:Ac) have been reported as the sex pheromone components of the genus Adoxophyes. Our objective was to determine the difference in sex pheromone composition of three different A. spp. populations each from Cheonan, Sangju, and Naju area orchards in Korea. Gas chromatography (GC) analyses of pheromone gland extracts of virgin females confirmed the presence of two compounds (Z9-14:Ac and Z11-14:Ac) in Cheonan and Sangju populations, and four compounds (Z9-14:Ac, Z11-14:Ac, E11-14:Ac and tome-12:Ac) in Naju population. The Z9-14:Ac and Z11-14:Ac were detected in the ratio of 80:20 in the Cheonan population and 3:97 in the Sangju population. Females of Naju population produced sex pheromone blend consisting of Z9-14:Ac, Z11-14:Ac, E11-14:Ac and 10me-12:Ac at a ratio of 31:62:6:1. Field trapping tests in pear orchards with Z9-14:Ac and Z11-14:Ac indicated that maximum captures of the male were obtained with traps baited by 80:20 in Cheonan, 10:90 in Sangju, and 30:70 in Naju. These results suggest that there are remarkable geographical variations in the sex pheromone composition of A. spp. in pear orchards in Korea, and taxonomic classification of these species must be carefully assessed.

DSP-based Current Programmed Control of Three Phase PWM AC-AC Boost Converter (3상 PWM AC-AC 부스트 컨버터의 DSP 기반 전류 프로그램 제어)

  • Choi Nam-Sup;Li Yulong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • In this paper, a new scheme of current programmed control for three phase PWM AC-AC converter is presented. Compared to duty-ratio voltage control, current programmed control has several advantages such as reduction of system order, inherent current protection and robust output. By considering only the magnitude components, a similar scheme in the DC-DC converter can be extended to the three phase PWM AC-AC converter. The proposed current programmed control will be well adopted into various converter topologies though three phase PWM AC-AC boost converter is treated as an example. The converter analysis is carried out by applying the vector DQ transformation to obtain physical insight into the converter operation and to establish some important characteristic equations for control purpose. The experiment results show the validity of the proposed scheme.

Optimization of Capacitance Balance for a Hybrid Supercapacitor Consisted of LiMn2O4/AC as a Positive and AC Negative Electrode

  • Cho, Min-Young;Park, Sun-Min;Lee, Jae-Won;Roh, Kwang-Chul
    • Journal of Electrochemical Science and Technology
    • /
    • v.2 no.3
    • /
    • pp.152-156
    • /
    • 2011
  • A hybrid supercapacitor is fabricated using a composite material from $LiMn_2O_4$ (LMO) and activated carbon (AC) as the positive electrode and AC as the negative electrode to form the (LMO + AC)/AC system. Volume ratio (positive : negative) of electrodes is controlled to investigate of the power and energy balance. The (LMO + AC)/AC system shows better performances than the LMO/AC system. Especially, electrochemical impedance spectra, rate charge.discharge and cycle performance testing show that the (LMO + AC)/AC system have an outstanding electrochemical performance at volume ratios of (LMO + AC)/AC = 1 : 1.7 and 1 : 2. Electric double layer capacitor (EDLC) capacitance between AC of the positive electrode and AC of the negative electrode improves power density without loss of capacitance. Stable capacitance is achieved by lowering the positive electrode resistance and balancing the energy and power densities between the positive and negative electrodes by the addition of AC to the positive electrode at high current density.

$NH_3$ oxidation using Ag-Cu/$Al_2O_3$ composite catalyst at low temperature (Ag-Cu/$Al_2O_3$ 복합촉매를 이용한 저온에서의 $NH_3$ 산화)

  • Lim, Yun-Hui;Lee, Ju-Yeol;Park, Byung-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.313-319
    • /
    • 2014
  • This study was performed to obtain high conversion efficiency of $NH_3$ and minimize generation of nitrogen oxides using metal-supported catalyst with Ag : Cu ratio. Through structural analysis of the prepared catalyst with Ag : Cu ratio ((10-x)Ag-xCu ($0{\leq}x{\leq}6$)), it was confirmed that the specific surface area was decrease with increasing metal content. A prepared catalysts showed Type II adsorption isotherms regardless of the ratio Ag : Cu of metal content, and crystalline phase of $Ag_2O$, CuO and $CuAl_2O$ was observed by XRD analysis. In the low temperature($150{\sim}200^{\circ}C$), a conversion efficiency of AC_10 recorded the highest(98%), whereas AC_5 (Ag : Cu = 5 : 5) also showed good conversion efficiency(93.8%). However, in the high temperature range, the amounts of by-products(NO, $NO_2$) formed with AC_5 was lower than that of AC_10. From these results, It is concluded that AC_5 is more environmentally and economically suitable.

A Study on the Contrast Ratio Improvement of Surface Discharge AC PDP (면방전 AC PDP에서 콘트라스트 개선에 관한 연구)

  • An, Yang-Ki;Yoon, Dong-Han
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.11
    • /
    • pp.536-540
    • /
    • 2002
  • This paper proposes a method to drive an AC plasma display panel(PDP) with a significantly improved contrast ratio. In the proposed method, during the first sub-field of one frame, all PDP cells are reset by the ramp waveform, and during the other sub-field, only the cells turned on in the previous sub-field are reset. No light is emitted during the reset period of every sub-field except the first sub-field. For a 10-bit picture, the luminance of the dark level for the proposed method is 10 times lower than that for the conventional method, in which the ramp waveform for the reset is used in every sub-field. Accordingly, the contrast ratio for the proposed method is 10 times higher than that for the conventional method. For the 10-bit picture, the measured contrast ratio was about 3080:1 for the proposed method and about 285:1 with the conventional method, a result the contrast ratio has been increased in 10.8 times. This result shows that the proposed method can realize an image with high contrast ratio.

Dual-Slope Ramp Reset Waveform to Improve Dark Room Contrast Ratio in AC PDPs

  • Lim, Jae-Kwnag;Cho, Byung-Gwon;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.639-642
    • /
    • 2005
  • A new dual-slope ramp (DSR) reset waveform is proposed to improve the dark room contrast ratio in AC-PDPs. The proposed reset waveform has two different voltage slopes during a ramp-up period. The first voltage slope is lower than the conventional ramp voltage slope, causing a reduction in the background luminance, whereas the second voltage slope is higher than the conventional ramp voltage slope, causing an increase in the background luminance. Thus, a bias voltage is also applied during the second voltage-slope period to adjust the background luminance and address discharge characteristics. As a result, the proposed dual-slope reset waveform can lower the background luminance, thereby improving the high dark room contrast ratio of an AC-PDP without reducing the address voltage margin

  • PDF

Dynamic Voltage Restorer (DVR) for 6.6[kV]/60[Hz] Power Distribution System Using Two Quasi Z-Source AC-AC Converters (두 개의 Quasi Z-소스 AC-AC 컨버터에 의한 6.6[kV]/60[Hz] 배전계통의 동적 전압 보상기(DVR))

  • Oum, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.199-208
    • /
    • 2012
  • This paper proposes a quasi Z-source DVR(Dynamic Voltage Restorer) system with a series connection of the output terminals, to compensate the voltage variations in the 6.6[kV]/60[Hz] power distribution system. The conventional DVR using one quasi Z-source AC-AC converter has the advantage which it can compensate the voltage variations without the need for the additional energy storage device such as a battery, but it is impossible to compensate for the 50[%] under voltage sags. To solve this problem, a DVR system using two quasi Z-source AC-AC converters with the series connection of the output terminals is proposed. By controlling the duty ratio D in the buck-boost mode, the proposed system can control the compensation voltage. For case verification of the proposed system, PSIM simulation is achieved. As a result, in case that the voltage sags-swells occur 10[%], 20[%], 60[%] in power distribution system, and, in case that the 50[%] under voltage sags-swells continuously occur, all case could compensate by the proposed system. Especially, the compensated voltage THD was examined under the condition of the 10[%]~50[%] voltage sags and the 20[${\Omega}$]~100[${\Omega}$] load changes. The compensated voltage THD was worse for the higher load resistances and more severe voltage sags. Finally, In case of the voltage swells compensation, the compensation factor has approached nearly 1 regardless of the load resistance changes, while the compensation factor of voltage sags was related to the load variations.