Design of Lateral Load Resisting System using Nonlinear Static Analysis (비선형 정적해석을 통한 횡저항 시스템의 보유성능 평가 및 설계방안 연구)

  • Song, Jin-Gyu;Kim, Geon-Woo;Jung, Sung-Jin;Song, Young-Hoon;Lee, Seung-Chang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.1 s.47
    • /
    • pp.9-16
    • /
    • 2006
  • The design practice of the lateral resisting system has been traditionally dependent on the experience and know-how of a structural engineer. And the method to reflect the evaluation results of building's capacity on design process doesn't exist. The proposal of a rational design of the lateral load resisting system is based on the available full capacity $(R_{ac})$ of a building and the minimum required capacity $(R_{code})$ suggested in the code. This study suggests thai nonlinear static analysis, which is the estimation of the lateral capacity with the pushover analysis, be included in the existing design procedure of the structure. After finishing the basic structural design, the lateral resisting capacity ol a building is estimated. At the phase of nonlinear static analysis, pushover analysis is peformed to define the fully yielded baseshear $(V_Y)$. When the design wind baseshear $(V_{wind})$ is bigger than the design seismic baseshear $(V_D)$, the value is checked to determine whether or not it is smaller than the $V_Y$. After confirming that it is smaller, the $R_{ac}$ of the structure is computed. If the $V_D$ is bigger at first, only the $R_{ac}$ is computed. When the value of the estimation shows remarkable differences with the $R_{code}$, repetition of the design modification is needed for those approximate to the $R_{code}$. Application of the proposed design procedure to 2-D steel braced RC buildings has proven to be efficient.

A Study on the Discharge Characteristics with New Penning Gas Mixture for AC plasma display panel (AC plasma display panel의 페닝 방전가스 혼합비 변화에 따른 방전특성 연구)

  • 박문필;이승준;이재경;황호정
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.2
    • /
    • pp.127-134
    • /
    • 2002
  • Recently, Plasma display panel(PDP) has been in the spotlight as one of the next generation flat-panel-display device. The luminance and luminous efficiency improvement is the hot issues for making a plasma display into a large flat panel device. In this paper, We suggest a new penning gas mixture, in order to find the optimum mixture gas in plasma display panel. The optimum gas composition has been found by the partial pressure of inert gases(such as Af and Kr added to matrix of He(70%)-Ne(27%)Xe(3%) and Ne(96%)-Xe(4%)). The influences of Ar or Kr addition to Ne(96%)-Xe(4%) and He(70%)-Ne(27%)-Xe(3%) mixture gases are experimentally investigated for AC Plasma Display Panel. When rare As(0.01%-0.03%) or Kr(0.01%-0.03%) is added Ne-Xe and He-Ne-Xe mixture gases, the luminance increases over 10%-20% and luminous efficiency increases over 10%-20% at 200 Torr. It is sure that luminance and efficiency are improved by Penning effect. Also, This influence of Penning effect is shown by increased wall charge(10%-25%). In addition to the result, firing voltage and minimum sustain voltage was approximately decreased by 2V-3V.

Removal of As(III) and Phenol by Multi-functional Property of Activated Carbon Impregnated With Manganese (망간첨착 활성탄의 다기능성을 이용한 3가 비소 및 페놀 제거)

  • Yu, Mok-Ryun;Hong, Soon-Chul;Yang, Jae-Kyu;Chang, Yoon-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.3
    • /
    • pp.52-58
    • /
    • 2008
  • Mn-impregnated activated carbon (Mn-AC) prepared at different conditions was applied in the treatment of synthetic wastewater containing both organic and inorganic contaminants. Phenol and As(III) was used as the representative organic and inorganic contaminants, respectively. After evaluation of the physicochemical characteristic and stability of Mn-AC, oxidation of As(III) as well as adsorption of phenol by activated carbon(AC) and Mn-AC were investigated in a batch reactor. To investigate the stability of Mn-AC, dissolution of Mn from each Mn-AC was measured pH ranging from 2 to 4. Although Mn-AC was unstable at a strong acidic condition, the dissoluted Mn was below 3 ppm at pH 4. XRD analysis of Mn-AC indicated that the mineral type of the impregnated manganese was $Mn_2O_3$. From the simultaneous treatment of As(III) and phenol by AC and Mn-AC, As(III) oxidation by Mn-AC was greater than that by AC at lower pH, while the reverse order was observed at higher pH. After impregnation of Mn onto AC, 13% decrease of the surface area was observed, causing 8% reduction of phenol removal. Considering removal properties of As(III) and phenol, Mn-AC could be applied in the simultaneous treatment of wastewater contaminated with multi-contaminants.

Studies on the Optical Resolution of DL-Amino Acids by Aminoacylase Immobilized on Chitosan: Properties and Reactivity of Immobilized Aminoacylase (Chitosan 고정화 Aminoacylase 를 이용한 DL 아미노산의 광학적 분할에 관한 연구 : 고정화 Aminoacylase의 성질 및 반응성)

  • Lee, Sang-Hyun;Lee, Young-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.547-552
    • /
    • 1988
  • Aminoacylase immobilized on chitosan was applied for optical resolution of DL-amino acids. Optimun pH's for hydrolysis of N-ac DL Met, N-ac DL Try and N-ac DL Phe by immobilized aminoacylase were 8.0, 7.0, and 7.5, respectively. The pH stability of immobilized aminoacylase was less than that of soluble enzyme, while there was no difference in thermostability between immibilized and soluble enzymes. The reaction rate of immobilized enzyme was maximum, when concentrations of N-ac DL Met, N-ac DL Try and N-ac DL Phe were 0.05, 0.03 and 0.05M, respectively. Continuous resolution of M/20 N-ac DL amino acids with immobilized aminoacylase packed in a column resulted in 100% hydrolysis upto space velocity $2.0\;at\;45^{\circ}C$, and the half-life of the column at space velocity 5.0 was about 25 days. The yield of L-Met, L-Try and L-Phe recovered from 2 liter of column effluent were 57%, 52% and 52%, respectively.

  • PDF

Comparison of Attenuation Correction Methods for Brain SPECT Ima (Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교)

  • Jo, Jin U;Kim, Chang Ho;Na, Soo Kyung;Lee, Gui Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.120-125
    • /
    • 2012
  • Purpose : The purpose of this study was to compare count between Chang's method and CT-based attenuation correction (AC-CT) among the attenuation correction (AC) methods for non-attenuation correction (AC-non) images of Brain SPECT (Single Photon Emission Computed Tomography). Materials and Methods : We injected $^{99m}Tc$ 37Mbq in a Hoffman 3D phantom filled with distilled water in the phantom study, and injected intravenously $^{99m}Tc$-HMPAO 740Mbq in a normal volunteer in the patient study, and then obtained Brain SPECT images with Symbia T6 of Siemens and conducted quantitative brain analysis. Transverse images to which each method was applied were rebuilt at the same position, and 6 regions of interest (ROI) were drawn on each of Slice No. 10, 20 and 30 and then the counts of AC-non, AC-CT and Chang's method were compared. Results : The mean counts of AC-non, AC-CT and Chang's method were $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, and $8752.6{\pm}896.5$, respectively, in the phantom study and $5460.8{\pm}519.6$, $15320{\pm}1171.6$ and $12795{\pm}1422.1$, respectively, in the patient study. In the phantom study, the ratio of AC-CT to AC-non was 3.70 and the ratio of Chang's method to AC-non was 1.92, and in the patient study, they were 2.85 and 2.38, respectively. Conclusion : From this study, we found that AC-CT makes higher AC than Chang's method. In addition, when Chang's method was used, AC in the patient study was higher than that in the phantom study. These results need to be considered also in other examinations.

  • PDF

Robust Disturbance Suppression Control for AC Servo Motors (AC 서보모터에 대한 견실한 외란억제 제어)

  • Kim, Chang-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.839-848
    • /
    • 2012
  • In this paper, we propose a robust control scheme of AC servo motors to suppress disturbance torques effectively. The proposed controller consists of both a model based feed-forward controller and a stabilizing feedback controller. The feed-forward controller is designed such that the output of the nominal plant tracks perfectly the reference velocity command with desired dynamic characteristics. The feedback controller stabilizes the overall closed loop system. Furthermore, the feedback controller contains a free function that can be chosen arbitrarily. The free function can be designed so as to achieve both suppression of disturbances and robustness to model uncertainties. In order to illuminate the superior performance of the proposed control scheme to the conventional ones, we present some simulation results.

Synthesis of Abscisic Acid Analogs and Their Biological Activity on Growth of Rice Seedling (합성 ABA 유도체의 벼 유묘 생장저해 작용)

  • Lee, Sang-Kap
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.3
    • /
    • pp.269-273
    • /
    • 1997
  • This research aims at developing a new plant growth inhibitors related to abscisic acid by means of esterification of (S)-(+)-ABA with p-hydroxy methyl cinnamate and umbelliferone, and testing its biological activity on growth of rice seedlings. The over-all yield of ABA-methyl cinnamate(AC) and ABA-umbelliferone(AC) ester compounds were 83% and 78%, respectively. The growth inhibition activity of these synthetic compounds were shown about 3 to 10 times(AC) and 10 to 30 times(AU) higher than (S)-(+)-ABA.

  • PDF

A Study on Excitation System for Synchronous Generator Using Two State Three Phase PWM AC/DC Converter (2단 3상 PWM AC/DC 컨버터를 이용한 동기발전기 여자제어시스템)

  • Lee, Sang-Hun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.96-106
    • /
    • 2007
  • The terminal voltage of a synchronous generator is maintained by the field current control of excitation system. Generally AC/DC converter which is component of AVR(Automatic Voltage Regulator) system for excitation current control is connected to diode rectifier and DC/DC converter system. In the case of diode rectifier system of phase controlled converter as AC/DC converter have low power factor and harmonics of lower order in the line current. In this paper, two stage three phase PWM AC/DC converter is studied to solve these problems. The characteristics of a proposed converter reduces the harmonics and reactive power of the distribution line and has fast dynamic response in transient period using boost converter and current control mode buck converts. The proposed method is verified by the computer simulation and experimental results in prototype generation system.

Study on Optimized Scheme of Reactive Power Compensation for Low Short-Circuit-Ratio HVDC System (저단락비 HVDC 시스템에서웨 무효편력수급 최적 방안 연구)

  • Baek Seung-Taek;Han Byung-Moon;Oh Sea-Seung;Jang Gil-Soo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.9
    • /
    • pp.434-440
    • /
    • 2005
  • This paper describes an optimized Scheme of reactive-power compensation for the low short-circuit-ratio AC system interconnected with the HVDC system. An HVDC system interconnected with tile low SCR AC system is vulnerable to the ac voltage variation, which brings about the commutation failure of the converter. This problem can be solved using optimized compensation of reactive power. In this study, a benchmark system for HVDC system interconnected with low SCR AC system is derived using PSS/E simulation. Then an optimized srheme for reactive power compensation was derived using integer programming. The feasibility of proposed scheme was analyzed through silnulations with PSS/E and PSCAD/EMTDC. The proposed scheme can compensate the reactive power accurately and minimize the number of switching for harmonic filters and shunt reactors.

Analysis of Switching Surge Over-voltage in AC/DC Hybrid Transmission Lines (AC/DC 병가선로의 개폐서지 과전압 해석)

  • Yoo, Seong-Soo;Shin, Koo-Yong;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.459-466
    • /
    • 2022
  • Switching surges are a common type of phenomenon that occur on any sort of power system network. These are more pronounced on long transmission lines and in high voltage converter stations. At AC/DC hybrid transmission lines, the insulation coordination of such lines is mainly dictated by the peak level of switching surges, the most dangerous of which include three phase line energization and AC/DC converter station. The power system structure consist of AC/DC hybrid transmission lines which is combination of AC 765kV and ±500kV HVDC 1 bipole system for contingency analysis. The power system under study and its components are simulated using EMTDC software package, the effects of the various AC/DC mixing power lines are reviewed. The developed models of EMTDC conversion lines based on combination of AC/DC system are simulated and the characteristics of switching surge over-voltage from its results are discussed.