• Title/Summary/Keyword: A-weighted Sound Exposure Level(ASEL)

Search Result 4, Processing Time 0.02 seconds

On the subjective response caused by impulse sounds produced by leisure shooting (레저용 사격 소음에 대한 주관적 반응)

  • Kim, Deuk-Sung;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.714-720
    • /
    • 2008
  • This research presents a laboratory study about an subjective response of impulsive sound caused by leisure shooting. The sources are sampled from outdoor noise and their levels range from 40 to 75 dB at the interval of 5dB. The noise unit is based on A-weighted sound exposure level (ASEL; $L_{AE}$). To make equal ASEL of outdoor noise, finite impulse response (FIR) filter is applied to the originally sampled source to include the effect of distance attenuation. The evaluation method of the jury test adopted a Semantic Difference(SD) Method. In the result of the jury test for impulsive noise, the mean response rating expressed a linear relation and %HA(percent highly annoyed) displayed a exponential growth relation.

  • PDF

Difference of subjective response between with and without pictures - Focusing on the leisure shooting noise - (화면 제공에 따른 주관적 반응의 차이 - 레저용 사격 소음을 중심으로 -)

  • Kim, Deuk-Sung;Chang, Seo-Il;Lee, Yeon-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.727-734
    • /
    • 2008
  • This research presents a laboratory study about difference of subjective response between with and without pictures. A main source is impulsive sound caused by leisure shooting. The sources are sampled from outdoor noise and their levels range from 40 to 75 dB at the interval of 5dB. The noise unit is based on A-weighted sound exposure level (ASEL; $L_{AE}$). To make equal ASEL of outdoor noise, finite impulse response (FIR) filter is applied to the originally sampled source to include the effect of distance attenuation. The evaluation method of the jury test adopted a Semantic Difference(SD) Method. The intersection point which two lines crossed was used as reference point. The intersecting point of mean response rating between with and without pictures was approximately 44ASEL and that of %HA was about 60ASEL. In the result of the test, the negative effect of pictures was given at a lower levels than intersection point while the positive effect was given at a higher levels than that.

  • PDF

Response of Annoyance for Impulsive Noise - Focusing on the Construction Noise - (충격성 소음에 대한 성가심 반응 - 건설공사장 소음을 중심으로 -)

  • Kim, Deuk-Seong;Jang, Seo-Il;Jeon, Hyeong-Jun;Lee, Yeon-Su
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1191-1196
    • /
    • 2007
  • This research presents a laboratory study about an annoyance of impulsive sound caused by construction site(breaker and blasting). The sources are sampled from outdoor noise and their levels range from 40 to 75 dB at the interval of 5dB. The noise unit is based on A-weighted sound exposure level (ASEL; $L_{AE}$). To make equal ASEL of outdoor noise, finite impulse response (FIR) filter is applied to the originally sampled source to include the effect of distance attenuation. The evaluation method of jury test adopted a Semantic Difference Method (SDM). In the result of the Jury test for impulsive noise, the annoyance response of blasting noise was higher than that of breaker noise.

  • PDF

The Subjective Response for Impulsive Sound - Focusing on the Construction Noise - (충격성 소음에 대한 주관적 반응 - 건설공사장 소음을 중심으로 -)

  • Kim, Deuk-Sung;Chun, Hyung-Jun;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.746-755
    • /
    • 2008
  • This research presents a laboratory study on subjective response of impulsive sound caused by construction site (breaker and blasting). The sources are sampled from outdoor noise and their levels range from 40 to 75 dBA at the interval of 5 dBA. The noise unit is based on A-weighted sound exposure level(ASEL; $L_{AE}$). To make equal ASEL of listening level, finite impulse response(FIR) filter is applied to the originally sampled source to include the effect of propagation attenuation. Sixty-three subjects, forty-two males and twenty-one female, between 18 and 29 years of age, participated in the experiment. The evaluation method of jury test adopted a semantic difference method(SDM). In the test results for impulsive noise, the subjective response of blasting noise was higher than that of breaker noise. The result of %HA that has been combined responses of the three methods except for pink-noise was executed by regression analysis and was shown as the following equation.: $%HA=746.53/(1+{\exp} (L_{AE}-93.3))+0.34$.