• Title/Summary/Keyword: A-scan signal

검색결과 290건 처리시간 0.027초

TFSCAN 검색 프로그램 TFSCAN의 개발

  • 이병욱;박기정;김기봉;박완;박용하
    • 한국미생물·생명공학회지
    • /
    • 제24권3호
    • /
    • pp.371-375
    • /
    • 1996
  • TFD is a transcription factor database which consists of short functional DNA sequences called as signals and their references. SIGNAL SCAN, developed by Dan S. Prestridge, is used to determine what signals of TFD may exist in a DNA sequence. This program searches TFD database by using a simple algorithm for character string comparison. We developed TFSCAN that aims at searching for signals in an input DNA sequence more efficently than SIGNAL SCAN. Our algorithms consist of two parts, one constructs an automata by scanning sequences of rFD, the other searches for signals through this automata. Searching for signal-related references is radically improved in time by using an indexing method. Usage of TFSCAN is very simple and its output is obvious. We developed and installed a TFSCAN input form and a CGI program in GINet Web server, to use TFSCAN. The algorithm applying automata showed drastical results in improvement of computing time. This approach may apply to recognizing several biological patterns. We have been developing our algorithm to optimize the automata and to search more sensitively for signals.

  • PDF

Signal Integrity 연결선 테스트용 다중천이 패턴 생성방안 (An Effective Multiple Transition Pattern Generation Method for Signal Integrity Test on Interconnections)

  • 김용준;강성호
    • 대한전자공학회논문지SD
    • /
    • 제45권10호
    • /
    • pp.39-44
    • /
    • 2008
  • 스캔 테스트 기법은 효과적인 테스트 성능 향상 기법이지만, 이를 위한 테스트 수행 시간이 너무나 길어진다는 단점이 있다. 본 논문에서는 동일한 테스트 입력을 이용하는 Illinois 스캔 기법을 기반으로 한 효율적인 스캔 테스트 기법을 제안한다. 제한하는 방안은 다수의 스캔 입력에 선택적으로 접근하여 다중 스캔 기법의 효과를 최대한으로 이용한다. 실험 결과는 제안하는 방안이 입력을 공유하기 위한 효율을 극대화 하여 매우 적은 테스트 시간과 테스트 데이터만을 필요로 함을 보여준다.

신호수신시스템 성능 검증을 위한 신호원 모의발생기 (Simulated RF Signal Generator for Receiver Performance Verification)

  • 김동규;윤원식
    • 한국정보통신학회논문지
    • /
    • 제16권10호
    • /
    • pp.2163-2170
    • /
    • 2012
  • 신호수신시스템은 수신신호의 주파수, 펄스변조, 스캔 변조, 펄스내 위상변조, 펄스내 주파수 변조 등 다양한 신호에 대한 측정 및 분석능력을 보유하여야 한다. 이러한 신호수신시스템의 성능을 평가하기 위하여 신호원들을 실험실 환경에서 효율적으로 모의발생하고 다수 전파가 존재하는 실제 운영환경과 유사한 복잡한 전파환경을 모의발생할 수 있는 효율적인 신호원 발생기를 제안한다. 제안한 모의전파신호원을 신호수신시스템 개발 전 과정에 걸쳐 활용할 경우 정확한 성능 검증 및 시험 비용을 절감할 수 있다.

초음파 섹터 스캐너를 위한 디지털 스캔 변환 기법 (Digital Scan Converter Algorithm for Ultrsound Sector Scanner)

  • 김근호;오정환
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권4호
    • /
    • pp.469-478
    • /
    • 1996
  • In the conventional digital ultrasound scanner, the reflected signal is sampled either in polar coordinates of R-$\theta$ method, or in Cartesian coordinates of uniform ladder algorithm (ULA). The R-$\theta$ scan method necessitates a coordinate transform process which makes hardware complex in comparison with ULA scan mrthoA In spite of this complexity, R-$\theta$ method has a good resolution in ultrasonographic (US) image, since scan direction of the US imaging is a radial direction. In this paper, a new digital scan converter is proposed, which is named the radius uniform ladder algorithm (RULA). The RULA has the rome scan direction as the US scanning in the radial direction and as the display space in the $\theta$ direction. In tllis new approach, sampled points we uniformly distributed in each horizontal line i.n well as in each radial ray so that the data are displayed in the Cartesian coordinates by the 1-D interpolation process. The propped algorithm has an uniform resolution in the periphery and the center field in comparison with equi-angle ULA and equi-interval ULA. To extend the scan angle, concentric square raster sampling (CSRS) is adopted with reduction of discontinuities on the junctions between horizontal scan and vertical scan. The discontinuities are reduced by using the hmction filtering along the $\theta$ direction.

  • PDF

스펙트럼 감시를 위한 고속 탐색 디지털-IF FFT 수신기 설계 및 분석 (A Design and Performance Analysis of the Fast Scan Digital-IF FFT Receiver for Spectrum Monitoring)

  • 최준호;나선필;박철순;양종원;박영미
    • 한국군사과학기술학회지
    • /
    • 제9권3호
    • /
    • pp.116-122
    • /
    • 2006
  • A fast scan digital-IF FFT receiver at the radio communication band is presented for spectrum monitoring applications. It is composed of three parts: RF front-end, fast LO board, and signal processing board. It has about 19GHz/s scan rate, multi frequency resolution from 10kHz to 2.5kHz, and high sensitivity of below -99dBm. The design and performance analysis of the digital-IF FFT receiver are presented.

직병렬 주사방식 일정장비의 신호처리기 설계 연구 (Electronic Processor Design for Thermal Imager with Serial/Parallel Scan type)

  • 송인섭;유위경;윤은석;홍영철;홍석민
    • 전자공학회논문지B
    • /
    • 제31B권1호
    • /
    • pp.49-56
    • /
    • 1994
  • This paper describes the design principles and methods of electronic processor for thermal imager with the SPRITE detector, operating in the 8-12 micron band. The thermal imager consists of a optical scanner containing the detector and an electrical signal processor. The optical scanner utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using 5 elements of the detector. And the electronic processor has pre-processing of 5 chnanel's thermal signal from the detector, and performs digital scan conversion to reform the parallel data stream into serial analog data compatible with conventional RS-170 video. Through the designed electronic processor, we have acquired a satisfactory thermal image. And the MRTD (Minimum Resolvable Temperature Difference) is 0.5$^{\circ}$K at 7.5 cycles/mm.

  • PDF

천해용 Side Scan Sonar의 송수신 시스템 구현 및 운용에 관한 연구 (Development of a Side Scan Sonar System for Underwater Sun)

  • 오영석;이철원;강도욱;우종식
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.222-227
    • /
    • 2000
  • "Side scan sonar" using acoustic signal has been developed to survey cable laying, sunken bodie\ulcorner bottom and so on. It use the acoustic signals, which are emitted from two transducer arrays, to get gemetri\ulcorner target area. This system consists of transceiver board, towed body, and deck unit. The transceiver board, w\ulcorner watertight canister of the towed body, controls the transmitting and receiving of 400kHz acoustic signals from \ulcorner After receiving the scattered signals, it processes the filtering, AGF(Automatic Gain Control), TVG(Time Heterodyne. The deck unit is composed of the signal processing part, A/D converter, power supplier, and real\ulcorner And the towed body has been designed to satisfy the optimal hydrodynamic behavior during towing. The de\ulcorner theory of transceiving part and some results from field-experiments will be introduced here.

  • PDF

디지탈 신호처리 프로세서의 테스터블 디자인 기법 (Testable Design Technique for Digital Signal Processor)

  • 김동석;김보환;이기준;최해욱
    • 전자공학회논문지A
    • /
    • 제32A권5호
    • /
    • pp.749-758
    • /
    • 1995
  • There are many testable design techniques, among which Scan path and BIST techniques are mainly used. In this paper, the increase of design effectiveness is discussed, when these techniques are applied to the practical implementation of chips. The following techniques are presented : 1) Blocks are commonly used to reduce test time without hardware increase, 2) MUX is used to implement the shortest Scan path, 3) Scan register is used which controls and/or observes several blocks to avoid the increase of hardware.

  • PDF

Enhancing Medical Images by New Fuzzy Membership Function Median Based Noise Detection and Filtering Technique

  • Elaiyaraja, G.;Kumaratharan, N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2197-2204
    • /
    • 2015
  • In recent years, medical image diagnosis has growing significant momentous in the medicinal field. Brain and lung image of patient are distorted with salt and pepper noise is caused by moving the head and chest during scanning process of patients. Reconstruction of these images is a most significant field of diagnostic evaluation and is produced clearly through techniques such as linear or non-linear filtering. However, restored images are produced with smaller amount of noise reduction in the presence of huge magnitude of salt and pepper noises. To eliminate the high density of salt and pepper noises from the reproduction of images, a new efficient fuzzy based median filtering algorithm with a moderate elapsed time is proposed in this paper. Reproduction image results show enhanced performance for the proposed algorithm over other available noise reduction filtering techniques in terms of peak signal -to -noise ratio (PSNR), mean square error (MSE), root mean square error (RMSE), mean absolute error (MAE), image enhancement factor (IMF) and structural similarity (SSIM) value when tested on different medical images like magnetic resonance imaging (MRI) and computer tomography (CT) scan brain image and CT scan lung image. The introduced algorithm is switching filter that recognize the noise pixels and then corrects them by using median filter with fuzzy two-sided π- membership function for extracting the local information.

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • 제26권5호
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.