• Title/Summary/Keyword: A-contraction

Search Result 2,592, Processing Time 0.03 seconds

Interpretation of Microscale Behaviors and Precision Measurement Monitoring for the Five-story and Seven-story Stone Pagodas from Cheongnyangsaji Temple Site in Gongju, Korea (공주 청량사지 오층석탑 및 칠층석탑의 정밀 계측모니터링과 미세거동 해석)

  • LEE Jeongeun;PARK Seok Tae;LEE Chan Hee
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.4
    • /
    • pp.132-158
    • /
    • 2023
  • The five-story and seven-story stone pagodas at Cheongnyangsaji temple site in Gongju are located under the Sambulbong peak of Gyeryongsan mountain, and are known to have been built of the middle in Goryeo dynasty. As the two pagodas in which two types of Baekje stone pagoda coexist in one era, their historical and academic value are recognized. The seven-story pagoda was overturned by robbery in 1944, and as a result, the five-story pagoda was tilted. Although the two pagodas were restored in 1961, structural instability was continuously raised. In this study, measurement data accumulated from May 2021 to March 2022, and seasonal characteristics were reviewed, and the micro behavior of pagodas were analyzed according to temperature and precipitation during the same period. As a result, the micro thermoelastic behavior was repeated according to the daily temperature change in all sensors, and both the slope and the displacement showed microscale behavior. In the inclinometer, moisture containing the surface and inside of the stones repeated expansion and contraction due to temperature change, showing the micro movements. In particular, the upper part of the five-story pagoda moved up to 3.89° to the northwest, and the seven-story pagoda tilted up to 0.078° to the northeast. The maximum displacements were recorded as 0.127 and 0.149 mm in the five-story and the seven-story pagoda, respectively. These values tended to return to the original position at the end of the measurement, but did not recover completely, indicating a state requiring precise monitoring. The result obtained through the study can be used as basic data for the stable conservation of the two stone pagodas. Based on the behavioral characteristics considering various environmental factors should be analyzed, and the preventive conservation through the maintenance of measurement system built this time should be continued.

Responsiveness of Muscarinic and Alpha Adrenergic Activation on Endothelial Cell in Isolated Canine Renal Arteries (개 신동맥 내피세포의 무스카린성 및 알파 아드레날린성 수용체에 대한 작용)

  • Chung, Soo-Youn;Chang, Ki-Churl;Lim, Jung-Kyoo
    • The Korean Journal of Pharmacology
    • /
    • v.25 no.1
    • /
    • pp.43-51
    • /
    • 1989
  • Responsiveness of muscarinic and alpha adrenoceptor activation on endothelial cells was studied in isolated canine renal artery rings. Ach (10-100 nM), dose dependently, relaxes endothelial intact rings precontracted with phenylephrine ($IC_{50}$ of Ach was 34.5 nM). Selective mechanical destruction of the endothelium transformed the activity of this substance from vasodilatation to vasoconstriction. Acetylcholine induced relaxations could be selectively inhibited competitively by atropine, but could not be inhibited by cyclooxygenase inhibitor. Methylene blue, however, an inhibitor of soluble guanylate cyclase activity, inhibited Ach as well as sodium nitroprusside (SNP) induced relaxation. Relaxation produced by prostacyclin was not modified by methylene blue. On the other hand, alpha adrenoceptor agonist did not relax but contract canine renal artery rings possessing an intact intima precontracted with U-46619. Clonidine, however, selective alpha-2 adrenergic agonist, is more susceptible than phenylepherine, selective alpha-1 adrenergic agonist, to the inhibitory effect of contraction. These results suggest that in canine renal artery rings, 1) muscarinic receptor is responsible for releasing endothelium dependent relaxation factor (EDRF). 2) alpha-1 and alpha-2 adrenergic receptors are present in canine renal artery. 3) relaxation via EDRF is antagonized by methylene blue, providing further evidence that EDRF acts through a cGMP mechanism.

  • PDF

A Study on the Development and Physical Properties of Low Yellowing Epoxy for Ceramic Preservation (도자기 복원용 저황변 Epoxy 수지의 개발 및 물성에 대한 연구)

  • Kim, Woo Hyun;Cheong, Da Som;Bae, Jin Soo;Jee, Joo Yeon;Wi, Koang Chul
    • Journal of Conservation Science
    • /
    • v.30 no.2
    • /
    • pp.181-187
    • /
    • 2014
  • AThe studies on ceramic preservation have been conducted widely in various institutions such as national/ public museums and research labs as well as the excavation institutions and university museums. Although there are some differences in preservation methodologies and materials used across the institutions, the variation is minimal. Specifically, epoxy resin is mostly used for ceramic restoration for its high cohesiveness, low contraction and high strength although there are some variations in for Ceramic Preservation. The synthetic resin type used according to the type of damage in the ceramic. However, the yellowing or the change of color across the time after the restoration is the weakness of epoxy resin. In this study, we aim to develop a material which minimizes this yellowing of epoxy resin while enhancing its cohesiveness and strength as well as other physical properties. We made the new material to have similar properties with those used widely for the ceramic restoration, such as EPO-TEK301$^{(R)}$, L30$^{(R)}$, XTR-311$^{(R)}$ through comparative experiments. The cohesiveness of the newly developed resin was improved to 2.51(MPa), which is similar level of XTR-311$^{(R)}$ of the 2.30(MPa) but about 2x higher than the other resins EPO-TEK301$^{(R)}$, L30$^{(R)}$ (1.21 and 1.81 (MPa), respectively). Especially, the experiment on yellowing shows that the existing resins show the range of color change at 10~25(${\Delta}E^*ab$), but the new low yellowing epoxy resin has the color change value at 8.3 (${\Delta}E^*ab$), the value lowering the yellowing effect to 1 to 3 times of the existing epoxy resin, thereby solving the issue of generating sense of differences due to change of color or yellowing.

Early Changes after Death of Plaice, Paralichthys olivaceus Muscle -6. Effect of Killing Methods on Morphological Changes of Myofibrills and Histological Changes of Muscle- (넙치 (Paralichthys olivaceus)육의 사후조기변화 -6. 치사 방법이 근원섬유의 형태학적 및 육의 조직학적인 변화에 미치는 영향-)

  • CHO Young-Je;LEE Nam-Geoul;KIM Yuck-Yong;KIM Jae-Hyun;LEE Keun-Woo;KIM Geon-Bae;CHOI Young-Joon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.4
    • /
    • pp.327-334
    • /
    • 1994
  • This study was undertaken to clarify the effect of killing methods on the morphological and histological changes of plaice, Paralichthys olivaceus muscle at early stage after killing. Killed samples by the three different methods were stored at $5^{\circ}$, and the changes in breaking strength of muscle, morphological observation of myofibrils and histological observation of extracellular spaces through storage were monitored. Samples killed by electrifying in sea water showed the maximum value of breakin strength immediately after killing and then it dropped significantly(p<0.05) until 2.5hrs passed. Breaking strength of samples killed by spiking at the head instantly and dipping in sea water including anesthetic rose steadily over 10hrs and 15hrs after killing, respectively. In myofibrills prepared from dorsal muscles immediately after spiking at the head instantly, A-band, H-band, I-band, and Z-line in sarcomere were clearly distinguishable each other. Due to muscle contraction by electrical stimulation, it was impossible to distinguish H-band from I-band observed in sarcomere immediately after killing for samples killed by electrifying. But, in the cases of samples killed by spiking and dipping, H-band could be observed dimly until 10hrs and 15hrs storage. No extracellular space was observed among muscle cells immediately after spiking at the head instantly. Samples killed by spiking at the head instantly and dipping in sea water including anesthetic showed extracellular spaces among all muscle cells after 15hrs and 25hrs storage, respectively. The other hand, samples killed by electrifying in sea water (110V, 30sec.) showed a few extracellular spaces immediately after killing and then it showed extracellular spaces among all muscle cells after 2.5hrs storage.

  • PDF

A STUDY ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN ACCORDING TO VARIOUS LIGHT-CURING METHODS (광조사 방법에 따른 복합레진의 중합수축에 관한 연구)

  • Kwon, Oh-Jin;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.102-109
    • /
    • 2003
  • The purpose of this study was to evaluate the linear polymerization shrinkage(%) and microhardness of composite resin(Z-100, 3M, USA) according to 2-step light curing method. Conventional light curing unit(Curing Light 2500, 3M USA) and 2-step light curing unit(Elipar Highlight, ESPE, Germany) were used as light source. The strain gauge method was used for determination of polymerization shrinkage(%). Samples were divided by 3 groups according to light curing methods (Group I : $450mW/cm^2$, 40sec, Group II : $650mW/cm^2$, 40sec, Group III : $150mW/cm^2$, 10sec & $650mW/cm^2$, 30sec). Preparations of acrylic molds were followed by filling and curing. Strain gauges attached to each sample were connected to a strainmeter. Measurements were recorded at each second for the total of 10 minutes including the periods of light application. And microhardness of each group after 24hours from light irradiation were measured. Obtained data were analyzed statistically using Ore-way ANOVA and/or Scheffe test. The results of the present study can be summarized as follows: 1. Composite resin in acrylic molds showed the initial expansion at the early phase of polymerization. This was followed by the contraction with the rapid increase in volume during the first 60 seconds and gradually diminished as curing process continued. 2. The lowest linear polymerization shrinkage(%) was found in group III followed by group I, II during the measuring periods. 3. Group III using 2-step curing method showed statistically significant reduction of linear polymerization shrinkage(%) compared with group I, II at 1 minute and 10 minutes from light irradiation(p<0.05). 4. The microhardness values of each group not revealed significant difference.

  • PDF

Development of Gated Myocardial SPECT Analysis Software and Evaluation of Left Ventricular Contraction Function (게이트 심근 SPECT 분석 소프트웨어의 개발과 좌심실 수축 기능 평가)

  • Lee, Byeong-Il;Lee, Dong-Soo;Lee, Jae-Sung;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.73-82
    • /
    • 2003
  • Objectives: A new software (Cardiac SPECT Analyzer: CSA) was developed for quantification of volumes and election fraction on gated myocardial SPECT. Volumes and ejection fraction by CSA were validated by comparing with those quantified by Quantitative Gated SPECT (QGS) software. Materials and Methods: Gated myocardial SPECT was peformed in 40 patients with ejection fraction from 15% to 85%. In 26 patients, gated myocardial SPECT was acquired again with the patients in situ. A cylinder model was used to eliminate noise semi-automatically and profile data was extracted using Gaussian fitting after smoothing. The boundary points of endo- and epicardium were found using an iterative learning algorithm. Enddiastolic (EDV) and endsystolic volumes (ESV) and election fraction (EF) were calculated. These values were compared with those calculated by QGS and the same gated SPECT data was repeatedly quantified by CSA and variation of the values on sequential measurements of the same patients on the repeated acquisition. Results: From the 40 patient data, EF, EDV and ESV by CSA were correlated with those by QGS with the correlation coefficients of 0.97, 0.92, 0.96. Two standard deviation (SD) of EF on Bland Altman plot was 10.1%. Repeated measurements of EF, EDV, and ESV by CSA were correlated with each other with the coefficients of 0.96, 0.99, and 0.99 for EF, EDV and ESV respectively. On repeated acquisition, reproducibility was also excellent with correlation coefficients of 0.89, 0.97, 0.98, and coefficient of variation of 8.2%, 5.4mL, 8.5mL and 2SD of 10.6%, 21.2mL, and 16.4mL on Bland Altman plot for EF, EDV and ESV. Conclusion: We developed the software of CSA for quantification of volumes and ejection fraction on gated myocardial SPECT. Volumes and ejection fraction quantified using this software was found valid for its correctness and precision.

Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique (폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서)

  • Lim Chang-Hyun;Kim Yong-Jun;Yoon Young-Ro;Yoon Hyoung-Ro;Shin Tae-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.599-604
    • /
    • 2004
  • Implantable flexible sensor using polymer/metal multilayer processing technique for telemetrical real-time blood pressure monitoring is presented. The realized sensor is mechanically flexible, which can be less invasively implanted and attached on the outside of blood vessel to monitor the variation of blood pressure. Therefore, unlike conventional detecting methods which install sensor on the inside of vessel, the suggested monitoring method can monitor the relative blood pressure without injuring blood vessel. The major factor of sudden death of adults is a disease of artery like angina pectoris and myocardial infarction. A disease of circulatory system resulted from vessel occlusion by plaque can be preventable and treatable early through continuous blood pressure monitoring. The procedure of suggested new method for monitoring variation of blood pressure is as follows. First, integrated sensor is attached to the outer wall of blood vessel. Second, it detects mechanical contraction and expansion of blood vessel. And then, reader antenna recognizes it using telemetrical method as the relative variation of blood pressure. There are not any active devices in the sensor system; therefore, the transmission of energy and signal depends on the principle of mutual inductance between internal antenna of LC resonator and external antenna of reader. To confirm the feasibility of the sensing mechanism, in vitro experiment using silicone rubber tubing and blood is practiced. First of all, pressure is applied to the silicone tubing which is filled by blood. Then the shift of resonant frequency with the change of applied pressure is measured. The frequency of 2.4 MHz is varied while the applied pressure is changed from 0 to 213.3 kPa. Therefore, the sensitivity of implantable blood pressure is 11.25 kHz/kPa.

A Clinical Study on the Surgical Treatment of the Rheumatic Cardiac Valve Disease (류마티스성 심장판막질환의 외과적 치료에 대한 임상적 연구)

  • 김종원;정황규;이성광;김병준;신영우
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.346-352
    • /
    • 1998
  • Rheumatic valvulitis produces at least three distinct pathologic changes, the degree varying widely among the patients: fusion of the valve leaflets at the commissures; fusion and shortening of chordae tendinae: and fibrosis of the leaflets with subsequent stiffening, contraction and calcification. The most extensive changes usually are seen in patients with recurrent attacks of rheumatic fever. We studied on outcome of the surgical treatments of rheumatic valvular diseases that have been experienced for 12 years since 1982 at Pusan National University Hospital. The diagnoses were made by rheumatic fever history, echocardiographic findings, gross operative findings and microscopic findings. Total 502 patients were performed surgery for valvular heart diseases and 440 patients of rheumatic origin have bene analysed. There were more female than male patients as 1.3:1, and the mean age was 37.8 years old. 96.3% of them affected to the mitral valve, 19.8% to aortic valve, 16.3% affected to the tricuspid valve. Most of them underwent valve replacement, and valve repair was done in 3.9% of patients. There were 36 hospital deaths(8.2%) mainly from low cardiac output syndrome, and 15 late deaths equally due to embolism and hemorrhage. Follow up was 90.1% completed(2890 patient- year). Linealized rates of late complication events are follows : thromboembolism 1.3% per patient year; anticoagulant related hemorrhage 0.8% per patient year. Overall actuarial survival including hospital mortality was 92.7+/-2.9% in 1 year, 88.0+/-4.5% in 5 year, 82.3+/-7.7% in 10 year. We conclude that the rheumatic disease is still the most frequent and the most important cause of heart valve disease. So more intensive study is needed in spite of the abrupt decreasing rate of rheumatic fever in U.S.A. and other industrial country.

  • PDF

Effects of FK224, a $NK_1$ and $NK_2$ Receptor Antagonist, on Plasma Extravasation of Neurogenic Inflammation in Rat Airways (미주 신경의 전기적 자극으로 유발된 백서의 기도내 혈장 유출에 대한 FK224의 효과)

  • Shim, Jae-Jeong;Lee, Sang-Yeub;Lee, Sang-Hwa;Park, Sang-Myun;Seo, Jeong-Kyung;Cho, Jae-Yun;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.744-751
    • /
    • 1995
  • Background: Asthma is an inflammatory disease because there are many inflammatory changes in the asthmatic airways. Axon reflex mechanisms may be involved in the pathogenesis of asthma. Sensory neuropeptides are involved in this inflammation, which is defined as neurogenic inflammation. Substance p, neurokinin A, and neurokinin B may be main neuropeptides of neurogenic inflammation in airways. These tachykinins act on neurokinin receptors. Three types of neurokinin receptors, such as $NK_1$, $NK_2$, and $NK_3$, are currently recognized, at which substance p, neurokinin A, and neurokinin B may be the most relevant natural agonist of neurogenic inflammation in airways. The receptor subtypes present in several tissues have been characterized on the basis of differential sensitivity to substance p, neurokinin A, and neurokinin B. Plasma extravasation and vasodilation are induced by substance p more potently than by neurokinin A, indicating NK1 receptors on endothelial cells mediate the response. But airway contraction is induced by neurokinin A more potently than by substance P, indicating the $NK_2$ receptors in airway smooth muscles. These receptors are used to evaluate the pathogenesis of brochial asthma. FK224 was identified from the fermentation products of Streptomyces violaceoniger. FK224 is a dual antagonist of both $NK_1$ and $NK_2$ receptors. Purpose: For a study of pathogenesis of bronchial asthma, the effect of FK224 on plasma extravasation induced by vagal NANC electrical stimulation was evaluated in rat airway. Method: Male Sprague-Dawley rats weighing 180~450gm were anesthetized by i.p. injection of urethane. Plasma extravasation was induced by electrical stimulation of cervical vagus NANC nerves with 5Hz, 1mA, and 5V for 2 minutes(NANC2 group) and for sham operation without nerve stimulation(control group). To evaluate the effect of FK224 on plasma extravasation in neurogenic inflammation, FK224(1mg/kg, Fujisawa Pharmaceutical Co., dissolved in dimethylsulphoxide; DMSO, Sigma Co.) was injected 1 min before nerve stimulation(FK224 group). To assess plasma exudation, Evans blue dye(20mg/kg, dissolved in saline) was used as a plasma marker and was injected before nerve stimulation. After removal of intravascular dye, the evans blue dye in the tissue was extracted in formamide($37^{\circ}C$, 24h) and quantified spectrophotometrically by measuring dye absorbance at 629nm wavelength. Tissue dye content was expressed as ng of dye per mg of wet weight tissue. The amount of plasma extravasation was measured on the part of airways in each groups. Results: 1) Vagus nerve(NANC) stimulation significantly increased plasma leakage in trachea, main bronchus, and peripheral bronchus compared with control group, $14.1{\pm}1.6$ to $49.7{\pm}2.5$, $17.5{\pm}2.0$ to $38.7{\pm}2.8$, and $12.7{\pm}2.2$ to $19.1{\pm}1.6ng$ of dye per mg of tissue(mean ${\pm}$ SE), respectively(p<0.05). But there was not significantly changed in lung parenchyma(p>0.05) 2) FK224 had significant inhibitory effect upon vagal nerve stimulation-induced airway plasma leakage in any airway tissues of rat,such as trachea, main bronchus, and peripheral bronchus compared with vagus nerve stimulation group, 49%, 58%, and 70%, respectively(p<0.05). Inhibitory effect of FK224 on airway plasma leakage in neurogenic inflammation was revealed the more significant in peripheral bronchus, but no significant in lung parenchyma. Conclusion: These results suggest that FK224 is a selective NK receptor antagonist which effectively inhibits airway plasma leakage induced by the endogenous neurotransmitters relased by neurogenic inflammation in rat airway. Tachykinin receptor antagonists may be useful in the treatment of brochial asthma.

  • PDF

A Study on the Manufacture of the Artificial Cardiac Tissue Valve (생체판의 제작 및 실험)

  • Kim, Hyoung-Mook;Song, Yo-Jun;Sohn, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.383-394
    • /
    • 1979
  • Treatment of valvular heart disease with valve replacement has been one of the most popular procedures in cardiac surgery recently. Although, first effort was directed toward the prosthetic valve, it soon became popular that bioprosthesis, the valvular xenograft, was prefered in the majority cases. Valvular xenograft has some superiority to the artificial prosthetic valve in some points of thromboembolism and hemolytic anemia, and it also has some inferiority of durability, immunologic reaction and resistance to Infection. Tremendous efforts were made to cover the inferiority with several methods of collection, preservation, and valve mounting of the porcine valve or pericardium of the calf, and also with surgical technique of the valvular xenograft replacement. Auther has collected 320 porcine aortic valves immediately after slaughter, and aortic cusps were coapted with cotton balls in the Valsalva sinuses to protect valve deformity after immersion in the Hanks' solution, and oxidation, cross-linking and reduction procedures were completed after the proposal of Carpentier in 1972. Well preserved aortic valves were suture mounted in the hand-made tissue valve frame of 19, 21, and 23 mm J.d., and also in the prosthetic vascular segment of 19 mm Ld. with 4-0 nylon sutures after careful trimming of the aortic valves. Completed valves were evaluated with bacteriologic culture, pressure tolerance test with tolerane gauge, valve durability test in the saline glycerine mixed solution with tolerance test machine in the speed of 300 rpm, and again with pathologic changes to obtain following results: 1. Bacteriologic culture of the valve tissue in five different preservation method for two weeks revealed excellent and satisfactory result in view of sterilization including 0.65% glutaraldehyde preservation group for one week bacteriologic culture except one tissue with Citobacter freundii in 75% ethanol preserved group. 2. Pressure tolerance test was done with an apparatus composed of V-connected manometer and pressure applicator. Tolerable limit of pressure was recorded when central leaking jet of saline was observed. Average pressure tolerated in each group was 168 mmHg in glutaraldehyde, 128 mmHg in formaldehyde, 92 mmHg in Dakin's solution, 48 mmHg in ethylene oxide gas, and 26 mmHg in ethanol preserved group in relation to the control group of Ringer's 90 mmHg respectively. 3. Prolonged durability test was performed in the group of frame mounted xenograft tissue valve with 300 up-and-down motion tolerance test machine/min. There were no specific valve deformity or wearing in both 19, 21, and 23 mm valves at the end of 3 months (actually 15 months), and another 3 months durability test revealed minimal valve leakage during pressure tolerance test due to contraction deformity of the non-coronary cusp at the end of 6 months (actually 30 months) in the largest 23 mm group. 4. Histopathologic observation was focussed in three view points, endothelial cell lining, collagen and elastic fiber destructions in each preservation methods and long durable valvular tolerance test group. Endothel ial cell lining and collagen fiber were well preserved in the glutaraldehyde and formaldehyde treated group with minimal destruction of elastic fiber. In long durable tolerance test group revealed complete destruction of the endothelial cell lining with minimal destruction of the collagen and elastic fiber in 3 month and 6 month group in relation to the time and severity. In conclusion, porcine xenograft treated after the proposal of Carpentier in 1972 and preserved in the glutaraldehyde solution was the best method of collection, preservation and valve mounting. Pressure tolerance and valve motion tolerance test, also, revealed most satisfactory results in the glutaraldehyde preserved group.

  • PDF