• Title/Summary/Keyword: A&BDOC

Search Result 25, Processing Time 0.022 seconds

The Utility of Measuring Assimiliable Organic Carbon (AOC) as an Indicator of Biostability in Distribution Systems for Finished Water

  • Chang, Young-Cheol;Toyama, Tadashi;Jung, Kweon;Kikuchi, Shitaro
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.6
    • /
    • pp.539-542
    • /
    • 2006
  • The objective of this paper is to compare the applicability of assimilable organic carbon (AOC) or biodegradable dissolved organic carbon (BDOC) for quantifying biodegradable organic material (BOM) and bio-stability in distribution systems for a variety of finished waters. The study the data is derived from was part of an AWWARF and Tampa Bay Water tailored collaboration project to determine the effect of blending different waters on distribution system water quality. Seven different finished waters were produced from surface, ground, or brackish water on site and fed 18 independent pilot distribution systems (PDSs), either as single finished water or as a blend of several finished waters. AOC and BDOC have often been used as indicators of bacterial regrowth potential in distribution systems. In this study, AOC was the more useful assay of the two for the BOM concentrations observed in the PDSs. BDOC did not distinguish BOM while AOC did at the low BOM levels from many of the advanced treatments (e.g. RO, $O^3/BAC$). AOC in contrast allowed much more meaningful calculations of the consumption or production of AOC as the blends passed through the PDSs even for very low BOM blends. In addition, meaningful trends corresponding to changes in heterophic plate count (HPC) were observed for AOC but not for BDOC. Moreover, AOC stability was associated with waters produced from advanced membrane treatment.

Decomposition of Organic Matters by Ozonation in Advanced Water Treatment Process (고도정수처리공정에서 오존의 유기물 분해능)

  • Yoon Taekyung;Lee Gangchoon;Noh Byeongjil
    • Journal of Environmental Science International
    • /
    • v.14 no.3
    • /
    • pp.327-333
    • /
    • 2005
  • The performance of ozone contactor in ozone-BAC advanced water treatment process was evaluated by the degree of decomposition of organic matters. The degree was measured by the analyses of $UV_{254}$ absorbance and the concentrations of DOC and BDOC for the sand filtered water and the ozone treated water, respectively. In addition, the ozone concentration in the contactor, required for the maximum BDOC concentration, was selected as the optimum concentration, and the appropriate residential time of ozone treated water in a reservoir was recommended based on the residual ozone concentration in the treated water. The following results were obtained from the pilot scale experiments. By ozonation $UV_{254}$ absorbance was decreased, and BDOC concentration was increased. The change of DOC concentration by ozonation was negligible, but the excess input of ozone resulted in the removal of the small amount of BDOC by complete oxidation. The optimum ozone concentration was 0.58mg $O_3/mg$ DOC. In order to remove residual ozone, 20minutes of the residential time were enough after ozonation.

Analysis of Attached Bacterial Communities of Biological Activated Carbon Process Using DGGE Method (DGGE 기법을 이용한 생물활성탄 공정의 부착 박테리아 군집분석)

  • Son, Hee-Jong;Choi, Jin-Taek;Son, Hyeng-Sik;Lee, Sang-Joon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.533-540
    • /
    • 2012
  • The concentration of organic compounds was analyzed at each step of BAC (biological activated carbon) process though BDOC (biodegradable dissolved organic carbon) total/rapid/slow. Further, bacteria communities and biomass concentrations measured DGGE (denaturing gradirnt gel electrophoresis) and ATP (adenosine triphosphate) methods were analyzed. The bed volume of steady state is different based on assessment of organic compounds removal. Bed volumes at steady state in DOC, $BDOC_{rapid}$ and $BDOC_{total/slow}$ removal were around 27,500, 15,000 and 32,000, respectively. A biomass didn't change after the bed volume reached 22,500 according to analyzing HPC (heterotrophic plate count) and ATP concentration of bacteria. The concentration of HPC and ATP were $3.3{\times}10^8$ cells/g and $2.14{\mu}g/g$, respectively. The number of the DGGE band were only 5 at the bed volume 8,916, but increased up to 11 at the bed volume 49,632. As operation time increase, bacterial group were more diversity. Four bacteria species including Pseudomonas fluorescens, the uncultured bacterium similar to Acinetobacteria, uncultured Novosphingobium sp. and Flavobacterium frigidarium have detected from the early stages and Proteobacteria group were dominantly detected.

Effect of Water Treatment for Nakdong River Raw Water by Continuous Ozone Process (연속식 오존처리공정을 이용한 낙동강 상수원수의 정수처리 효과)

  • Lim, Young-Sung;Kang, Gwan-Ho;Lee, Hong-Jae;Seo, Dong-Cheol;Park, Moon-Su;Heo, Jong-Soo;Cho, Ju-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.3
    • /
    • pp.189-196
    • /
    • 2002
  • This study was carried out to evaluate the pollutant removal efficiencies of the advanced drinking water treatment using ozonation process. For raw water, Nakdong River was used. By conducting continuous ozonation experiments, the following results were obtained. Efficiency of water treatment was enhanced with increase in ozone dosage. When ozone dosage of 3 mg/L was used, preozonation ot raw water reduced TDOC, ADOC, A &BDOC and NRDOC as much as 0.6 mg/L, 0.2 mg/L, 0.1 mg/L and 1.0 mg/L, respectively. On the other hand, content of BDOC increased at the level of 0.8 mg/L. Ratio of UV254 absorbance to DOC content by the preozonation with 1, 3 and 5 mg/L dosage were 0.048, 0.044 and 0.037, respectively. In case of postozonation, it were 0.018, 0.015 and 0.012, respectively. When the ratios of consumpted ozone content to 1 mg of initial DOC were 1.5 and 2.3 in preozonation and postozonation treatment, respectively, the highest DOC removal rates of 25% and 32% were obtained by the continuous ozonation.

Evaluation of Biomass of Biofilm and Biodegradation of Dissolved Organic Matter according to Changes of Operation Times and Bed Depths in BAC Process (BAC 공정에서 운전기간 및 여층깊이 변화에 따른 생물막 생체량 및 용존유기물질 생분해 특성 평가)

  • Son, Hyeng-Sik;Jung, Chul-Woo;Choi, Young-Ik;Lee, Gun;Son, Hee-Jong
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1101-1109
    • /
    • 2014
  • In this study we followed biofilm formation and development in a granular activated carbon (GAC) filter on pilot-scale during the 12 months of operation. GAC particles and water samples were sampled from four different depths (-5, -25, -50 and -90 cm from surface of GAC bed) and attached biomass were measured with adenosine tri-phosphate (ATP) analysis and heterotrophic plate count (HPC) method. The attached biomass accumulated rapidly on the GAC particles of top layer throughout all levels in the filter during the 160 days (BV 23,000) of operation and maintained a steady-state afterward. During steady-state, biomass (ATP and HPC) concentrations of top layer in the BAC filer were $2.1{\mu}g{\cdot}ATP/g{\cdot}GAC$ and $3.3{\times}10^8cells/g{\cdot}GAC$, and 85%, 83% and 99% of the influent total biodegradable dissolved organic carbon ($BDOC_{total}$), $BDOC_{slow}$ and $BDOC_{rapid}$ were removed, respectively. During steady-state process, biomass (ATP and HPC) concentrations of middle layer (-50 cm) and bottom layer (-90 cm) in the BAC filter were increased consistently. Biofilm development (growth rate) proceed highest rate in the top layer of filter (${\mu}_{ATP}=0.73day^{-1}$; ${\mu}_{HPC}=1,74day^{-1}$) and 78%~87% slower in the bottom layer (${\mu}_{ATP}=0.14day^{-1}$; ${\mu}_{HPC}=0.34day^{-1}$). This study shows that the combination of different analytical methods allows detailed quantification of the microbiological activity in drinking water biofilter.

Analysis of Attached Bacterial Community of Biological Activated Carbon Process Using FISH (FISH 기법을 이용한 생물활성탄 공정에서의 운전기간별 부착 박테리아 군집변화 분석)

  • Son, Hyeng-Sik;Son, Hee-Jong;Park, Geun-Tae;Lee, Sang-Joon
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.25-35
    • /
    • 2013
  • The concentration of organic compounds was analyzed at each step of BAC process though $BDOC_{total/rapid/slow}$. Further, bacteria communities and biomass concentrations measured FISH and ATP methods were analyzed. The bed volume (BV) of steady state is different from that of based on assessment of organic compounds removal. Bed volumes in DOC, $BDOC_{rapid}$ and $BDOC_{total/slow}$ removal at steady state were around 27,500 (185.8 day), 15,000 (101.4 day) and 32,000 (216.2 day), respectively. A biomass didn't change after the bed volume reached 22,500 (152.0 day) according to analyzing ATP concentration of bacteria. The concentration of ATP was 2.14 ${\mu}g/g$ in BV 22,500 (152.0 day). The total bacterial number was $4.01{\pm}0.4{\times}10^7$ cells/g at the bed volume 1,150 (7.8 day) (the initial operation) and the number of bacteria was $9.27{\pm}0.2{\times}10^9$ at the bed volume 58,560 395.7 day) that increased more than 200 times. Bacterial uptrend was reduced and bacterial communities were stabilized since BV 18,720 (126.5 day). When BV were 1,150 (7.8 day), 8,916 (60.2 day), 18,720 (126.5 day), 31,005 (209.5 day), 49,632 (335.3 day), 58,560 (395.7 day), a proportion of total bacteria for the Eubacteria were 60.1%, 66.0%, 78.4%, 82.0%, 81.3% respectively. ${\gamma}$-Proteobacteria group was the most population throughout the entire range. The correlation coefficient ($r^2$) between Eubacteria biomass and ATP concentration was 0.9448.

Evaluation of Advanced Oxidation Process(AOP) as a Pretreatment Process of Biological Activated Carbon in Drinking Water Treatment (정수처리에서 생물활성탄의 전처리로서 고급산화처리법의 평가)

  • Kim Woo-Hang
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.725-730
    • /
    • 1999
  • The advanced oxidation process (AOP) using ozone combined with hydrogen peroxide and ultraviolet treatment were evaluated for biodegradable dissolved organic carbon (EDOC) formation and dissolved organic carbon (DOC) removal. Oxidation treatment were conducted alone or combination with ozone, hydrogen peroxide and ultraviolet processes. Ozone dosage of ozone process was varied from $0.5mg/l{\ell}\cdot}min$ to $5mg/{\ell}{\cdot}min$. Ozone/hydrogen peroxide process was done using $20mg/{\ell}{\cdot}min$ of hydrogen peroxide concentration. Ozone/ultraviolet process was irradiated with $12mW/cm^2$ of density and 254nm. Ozone dosage was varied from $0.5mg/{\ell}{\cdot}min$ to $5mg/{\ell}{\cdot}min$ at the ozone/hydrogen peroxide and ozone/ultraviolet processes too. Contact time of all the process was 20 minutes. Oxidation treatment were performed on microfiltration effluent samples. BDOC formation was reached to an optimum at ozone dosage of $1.5mg/{\ell}{\cdot}min$ in the ozone/hydrogen peroxide process and $1mg/{\ell}{\cdot}min$ in ozone/ultraviolet process, after which BDOC formation was decreased at higher ozone dosages. But BDOC formation was increased with ozone dosages increasing in ozone process. The efficiency of DOC removal was higher AOPs than ozone process. Ozone/ultraviolet proces was the highest for DOC removal efficiency in each process. THMFP. removal efficiency by ozone/ultraviolet process was higher than that by each of ozone process and ozone/hydrogen peroxide process.

  • PDF

A study on the BAC pilot plant in the Duk-san water works (덕산(德山) 정수장(淨水場)에서의 BAC Pilot plant에 관한 연구(硏究))

  • Lee, Sang-Bong;Kim, Dong-Youn;Lim, Jung-A;Lee, Won-Gwon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.2
    • /
    • pp.97-107
    • /
    • 1995
  • Today a conventional water treatment system has many problems. The ozone/GAC process, sometimes termed Biological Activated Carbon(BAC), appeared to be effective for the removal of soluble organic matters in the drinking water. The water quality of Nak-dong river in Pusan, generally shows BDOC 30-40% and NBDOC 60-70%. The pilot plant installed at the Duk-san water works that was been largest treatability(1,650,000ton/day) in Pusan. A experimental water in the pilot plant made use of the water after sand-filteration. Following results are drawn from this study. Initial adsorption velocity($DOC/DOC_o/T$) in the pure adsorption of GAG had a 0.0225, it's velocity changed to 0.006 after ozone added and the optimum ozone dose ranged of $1.4-2.0mgO_3/L$. A experimental water in the pilot plant composed with humic material(78%). Humic material composed with humic acid(20%) and fulvic acid(56%), and it's rate changed to 18 and 50% respectively after ozone added. DOC constantly decreased in the EBCTs and removal efficieny in the 15min of EBCT was 45-50%. It showed the largest removal rate of BDOC in the EBCT 5 and among the season, characteristics of removal varied. The HPC distributed over $10^6-10^7CFU/cm^3$ in the bed depth and among the season, distribution of HPC were differential.

  • PDF

A Study on the Biodegradability and Characteristics Based on Apparent Molecular Weight Distribution of Dissolved Organic Matter in Sewage (하수중 용존 유기물의 생분해도 및 분자량 분포에 따른 거동특성에 관한연구)

  • 최정헌;이윤진;명복태;우달식;이운기;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.92-99
    • /
    • 2001
  • This present study was aimed to investigate the characteristics of dissoloved organic matter (DOC) in sewage. The results are summarized as follows ; The plateaux reached in 3~4 days by the biodegradability test on sewage samples based on DOC. 쏭 rations of BDOC to DOC were 48, 21, 13 and 11% for raw sewage, primary treatment effluent, secondary treatment effluent and final treatment effluent, respectively. As the SUVA values ranged less 3L/m.mg for the effluent of sewage treatment plant, the DOC is composed largely of non-humic materials, hydrophilic, less aromatic as compared to waters with higher SUVA values. Through the biodegradability test, Dissolved organics showed that the quantity of LMW(Low Molecular Weight) less than 1,000 daltons was decreased, HMW(High Molecular Weight) more than 30,000 daltons had a tendency to increase. Large portion of UV$^{254}$ in final treatment effluent was increased of MMW(Medium Molecular Weight). Also, average removal efficiency of DOC was 32% during sewage treatment.

  • PDF

Effect of Ozonation on Removal of Dissolved Organic Matter by Granular Activated Carbon Process (오존공정이 입상활성탄공정에서 용존유기물질의 제거에 미치는 영향)

  • Ahn, Hyo-Won;Chae, Seon-Ha;Wang, Chang-Keun;Lim, Jae-Lim
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.601-608
    • /
    • 2008
  • The objective of this study was to evaluate the effect of ozonation as pretreatment on the removal of dissolved or biodegradable organic matter(DOM or BOM), the variance of DOM fractionation, and microbial regrowth by pilot-scale granular activated carbon processes in which adsorption and biodegradability was proceeding due to long time operation. Regardless of point of ozonation applied, GAC processes with ozonation(i.e., Ozonation combined with GAC Filter-adsorber; Pre O$_3$ + F/A, Ozonation combined with GAC adsorber; Post O$_3$ + GAC) compared with GAC processes without ozonation(i.e., GAC Filter-adsorber; F/A, GAC adsorber; GAC) removed approximately 10 to 20% more of DOC, hydrophilic DOM(HPI), BDOC and AOC after long period of operation that biological activity was assumed to happen. Ozonation was not found to have a significant effect on the removal of DOC, but caused the decrease of AOC by approximately 20%. It was found that the fixed bacterial biomass on GAC media did not show a significant difference between the GAC with ozonation and GAC without ozonation as pre-treatment, whereas the HPC of column effluent was more biostable at Post O$_3$ + GAC compared with F/A or GAC.