• Title/Summary/Keyword: 9/7 Filter

Search Result 481, Processing Time 0.033 seconds

A Design of CPW Band-Pass Filter with Rejection Band for Ultra-Wideband System (저지 대역을 갖는 UWB용 CPW 대역 통과 여파기의 설계)

  • No, Jin-Won;Hwang, Hee-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.704-709
    • /
    • 2007
  • In this paper, a CPW band-pass filter with a rejection band is proposed for UWB(Ultra-Wideband) communication systems. The proposed filter has a band-pass characteristic of wide-band by inserting only a slot in $50{\Omega}$ transmission line. To obtain the band-rejection function at WLAN frequency band($5.15{\sim}5.725GHz$), the designed filter is combined with folded slot resonators on the ground plane of the CPW structure. The fabricated CPW band-pass filter shows a compact size of $15.35{\times}13.60mm$, a wide passband of 2.8 GHz to 9.8 GHz and the narrow stop-band of 5.15 GHz to 5.71 GHz for 3-dB bandwidth. Also, the measured group delay is less than 400 psec throughout the operation frequency band except the rejection band.

Implementation of Filter for the Removal of Partial Volume Effect (부분용적효과 제거를 위한 Filter 구현)

  • Park, Minju;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.139-145
    • /
    • 2015
  • When examining a patient using SPECT, gamma rays emitted from the body decrease or scatter. And when they reach the detector they spread in accordance with physical characteristics and geometric shapes of the scanner, quantitative analysis was difficult. For exact quantitative analysis of gamma rays emitted from the body, so that they must be considered to correction about PVE(partial volume effect). In this paper, sinogram filter was implemented to solve comprehensive PVE of SPECT. According to the results in which implemented filter was applied, partial volume effect caused by SPECT was removed. To compare proposed method and conventional method, PSNR(Peak Signal to Noise Ratio) was executed. As a result, proposed method was indicated as 7dB, conventional method was indicated as 14db respectively. dB(decibel) level of the proposed methods is lower, since the MSE(mean square error) becomes greater because scattered ray was removed, PSNR value is low. Therefore, by applying the proposed method for removing the PVE of SPECT imaging method, the image quality is improved.

The fingerprint feature extraction and matching method using Gator-filter in the fingerprint - recognition (지문인식에서의 Gabor-filter를 사용한 Feature추출과 Matching 기법)

  • 박준범;송명철;김영구;고한석
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.433-436
    • /
    • 2001
  • 본 논문에서는, 지문인식에 있어서 특징 추출알고리즘과 추출된 특징을 가지고, matching하는 알고리즘을 제안하였다. 지문인식에 필요한 특징추출 알고리즘들은 Gabor-filter라는 알고리즘에 기반을 두었으며, minutiae 와는 달리 특징추출에 있어서 전처리과정(smoothing, binarization, thining, restoration) 을 필요로 하지않는다. 또한, 지문의 matching에 있어서의 알고리즘은 fingercode들 간의 유사성에 기반을 두었다. 이를 통한 실 험결과로써, 인식의 정확성은 95.7(%), FAR(2.9%), FRR(1.4%)을 보여주었다.

  • PDF

An Efficient Interpolation FIR Filter Using LUT

  • Kim, Dae-Ik;Lee, Chang-Ki
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.219-222
    • /
    • 2009
  • An efficient interpolation FIR filter structure for high-density and low-power electronic devices is proposed. The proposed structure is based on polyphase decomposition property and look-up table method. By computer-aided design simulations, it is shown that the use of the proposed method can result in reduction in the number of gates by 54% and can reduce power consumption by 9%.

The Preliminary Study on the Quantitative Analysis of Quarts by Fourier Transform Infrared Spectrophotometric Direct on Filter(FTIR-DOF) Method -Effects of filter materials, inhomogeneity of deposition, and humidity- (Fourier Transform Infrared Spectrophotometric Direct on Filter 방법을 이용한 석영 분석의 기초 연구 - 필터재질, 비균일 침착 및 습도의 영향 -)

  • Phee, Young Gyu;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Although the Fourier Transform Infra-Red spectrophotometric Direct on Filter(FTIR-DOF) method is a useful analytical technique for quantifying quartz content in respirable dust samples, a number of analytical problems must be taken into consideration such as, to name only a few, inhomogeneous deposition of particles, level of environmental humidity, uneven surface of the filter, and interfering minerals in the sample. This study was designed to select the most suitable wavelength and proper filter material for the method, and to investigate effects of humidity and inhomogeneous deposition of particles on the filter. Samples of respirable dust, created in a dust chamber containing standard material of quartz, were collected using a cyclone equipped with a 25mm filter as a collection medium. The results were as follows; 1. Among seven (7) commercially available filters tested for the FTIR-DOF method, the DM 800 filter showed the best analytical performance having the lowest background absorbance bands and no overlapping peaks at 799, 779, and $695cm^{-1}$. 2. The variations of absorbance due to humidity ranged from 1.0% to 3.3% for $799cm^{-1}$, 1.0% to 3.3% for $779cm^{-1}$, and 8.9%~20.9% for $695cm^{-1}$ peaks, respectively. The $699cm^{-1}$ peak was proved to be most vulnerble to environmental humidity for quantitative analysis of quartz. 3. As for effects of inhomogeneous deposition of samples, the highest variation of absorbance of 10.9% ($13.5{\mu}g$) was observed when using the 695cm-1. The variations of absorbance from the other two peaks, 799 and $779cm^{-1}$, ranged from 1.2 to 3.2%, and 1.4 to 4.1%, respectively. Therefore, the $799cm^{-1}$ peak was considered to be most reliable for quantitative analysis of quartz. The results of this study suggest that, for quantitative analysis of quartz in the respirable dust samples, use of the $799cm^{-1}$ peak can minimize the influence of environmental humidity and inhomogeneous deposition of particles on the filter. The FTIR-DOF method, if adopted for routine analysis of quartz in the respirable dust samples, could save sample preparation time and efforts substantially and also could increase analytical throughputs. Since use of the $799cm^{-1}$ peak is prone to be affected by interferences in the sample, further research on minimizing the effects is needed.

A Lossless Image Compression using Wavelet Transform with 9/7 Integer Coefficient Filter Bank (9/7텝을 갖는 정수 웨이브릿 변환을 이용한 무손실 정지영상 압축)

  • Chu Hyung Suk;Seo Young Cheon;Jun Hee Sung;Lee Tae Ho;An Chong Koo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.1
    • /
    • pp.82-88
    • /
    • 2000
  • In this paper, We compare the Harr wavelet of the S+P transform with various integer coefficient filter banks and apply 9/7 ICFB to the wavelet transform. In addition, we propose a entropy-coding method that exploits the multiresolution structure and the feedback of the prediction error, and can efficiently compress the transformed image for progressive transmission. Simulation results are included to compare to the compression ratio using the S+P transform with different types of images.

  • PDF

A Study on Tuning Factor(δ) and Quality Factor(Q) Values in Design of Single-Tuned Passive Harmonic Filters (단일동조 수동고조파필터 설계시의 동조계수(δ) 및 양호도(Q)값 연구)

  • Cho, Young-Sik;Cha, Han-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.64-70
    • /
    • 2010
  • This paper presents how to decide on tuning factor(${\delta}$) and quality factor(Q) values in design of single-tuned passive harmonic filters. Tuning factor(${\delta}$) and quality factor(Q) values have to consider before decision on circuit parameters of passive filters. A Study on these two value has not been scarcely performed and only experienced values has been used in passive harmonic filter design by far. As a experienced value, in cases of 5th and 7th filter, tuning factor(${\delta}$) is about 0.94 and 0.96 respectively and quality factor(Q) is, in all cases of, 50. If Single-tuned passive harmonic filter will be off-tuned, performance of filter will be decreased steeply and occur to parallel resonance between system reactance and filter capacitance. Therefore During the operation, In order not to off-tuning, Filter must be tuned at former order than actual tuning order. This is the same that total impedance of filter must have a reactive impedance. In this paper, Tuning factor(${\delta}$) is decided via example of real system and using the bode-plot and then performance of filters confirmed by filter current absorbtion rate. And Quality factor(Q) decided using the bode plot in example system and then performance of filters confirmed by filter current absorbtion rate also, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. Finally, Performance of the designed passive harmonic filter using the tuning factor(${\delta}$) and quality factor(Q) values, decided in this paper is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th current harmonic distortions are decreased within IEEE-519 distortion limits, respectively.

Cultural Characteristics and Fruiting-body Productivity of New Variety 'Hwadam' (Lentinula edodes) According to Filter Treatment in Boxes (상자에 필터처리에 따른 표고 신품종 '화담'의 재배특성 및 자실체 생산성)

  • Kim, Jeong-Han;Kang, Young-Ju;Baek, Il-Sun;Shin, Bok-Eum;Ha, Tai-Moon;Jung, Gu-Hyun
    • The Korean Journal of Mycology
    • /
    • v.48 no.2
    • /
    • pp.95-102
    • /
    • 2020
  • This study was carried out to develop a new method of cultivation of 'Hwadam' a new variety of Lentinula edodes, to improve fruiting body productivity and reduce labor. To determine the optimum filter number for box cultivation, L. edodes were assessed for their cultural characteristics and mushroom yield. During spawn running of L. edodes in the box, the temperature gradually increased to the highest value of 25.8℃, 23.7℃, and 23.0℃ on day 18 for the four filter, two filter, and no treatment groups, respectively. Oxygen concentration displayed an opposite trend to carbon dioxide concentration, reaching the lowest value on day 21. The oxygen concentration progressively increased as more filters were used (5.4%, 8.2%, and 8.9% treatment with no, two, and four filters, respectively. Growth of L, edodes in the box resulted in the highest yield (2,228 g/7kg substrate) and biological efficiency (70.7%) using four filters. The biological efficiency of the four filter treatment was 29.4% higher compared to bag cultivation (41.3%). Further studies are necessary to verify stable productivity of fruiting bodies through repeated cultivation.

Consideration of the X-ray Spectrum Change and Resolution According to Added Filters, SID, A-Si (CsITl) in the Imaging System (A-Si(CsITl) 영상시스템에서 부가필터, SID에 따른 X선 스펙트럼변화와 해상력에 대한 고찰)

  • An, Hyeon;Kim, Jung-Hoon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.7
    • /
    • pp.681-688
    • /
    • 2016
  • This study assess their quality of radiation on analysis of the spectrum of resolution suggesting IEC 61267 in radiation quality that RQA3, RQA5, RQA7, RQA9 and combination of clinical condition using several quality of radiation. In experiments edge method first, the spatial resolution assessment used image of the additional filter and SID is obtained the IEC 62220-1, spatial resolution and sharpness of the obtained image was evaluated in the MTF value 10%(0.1), MTF value 50%(0.5) using a Matlab program. Second, MCNPX simulation used spatial resolution analysis was radiation quality particle fluence and spectrum analysis in energy. As a result, make use of additional filter, image quality evaluation of SID that RQA3 radiation quality combination qualification is higher spatial resolution and sharpness make unused of additional filter and SID 100cm. RQA7 radiation quality combination qualification is higher that spatial resolution make unused of additional filter and SID 150cm. RQA9 radiation quality combination qualification is higher that spatial resolution and sharpness make used of additional filter and SID 180cm. spectrum analysis of radiation quality by reducing consequent errors occurring in the experiment that error due to the reproducibility of the X-ray tube, occur in an error of correction the detector suggest ideal conditions from spectrum analysis through MCNPX simulation. In conclusion, by suggesting spatial resolution and sharpness of result for various radiation quality, It provide basic data that radiation quality condition and quantitative assessment method for laboratory in clinical using detector evaluation.

Highly Miniaturized and Performed UWB Bandpass Filter Embedded into PCB with SrTiO3 Composite Layer

  • Cheon, Seong-Jong;Park, Jun-Hwan;Park, Jae-Yeong
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.582-588
    • /
    • 2012
  • In this paper, a highly miniaturized and performed UWB bandpass filter has been newly designed and implemented by embedding all the passive elements into a multi-layered PCB substrate with high dielectric $SrTiO_3$ composite film for 3.1 - 4.75 GHz compact UWB system applications. The high dielectric composite film was utilized to increase the capacitance densities and quality factors of capacitors embedded into the PCB. In order to reduce the size of the filter and avoid parasitic EM coupling between the embedded filter circuit elements, it was designed by using a $3^{rd}$ order Chebyshev circuit topology and a capacitive coupled transformation technology. Independent transmission zeros were also applied for improving the attenuation of the filter at the desired stopbands. The measured insertion and return losses in the passband were better than 1.68 and 12 dB, with a minimum value of 0.78 dB. The transmission zeros of the measured response were occurred at 2.2 and 5.15 GHz resulting in excellent suppressions of 31 and 20 dB at WLAN bands of 2.4 and 5.15 GHz, respectively. The size of the fabricated bandpass filter was $2.9{\times}2.8{\times}0.55(H)mm^3$.