• 제목/요약/키워드: 5-Force

검색결과 6,280건 처리시간 0.035초

A Study on Arc Force Sensor for a Robotic Welding Control System

  • Son, Joon-Sik;Kim, Ill-Soo;Choi, Seung-Gap;Kueon, Yeong-Seob;Lee, Duk-Man
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.128.5-128
    • /
    • 2001
  • This paper presents investigation of an arc force sensor for a robotic welding control system. Arc force sensor is employed in this research to monitor the bead geometry of the arc welding process. Arc force sensor mounted at the end of the robot wrist was employed to measure the arc force applied to the weld. Experimental configuration for measurement of arc force was used to quantify the changes in the arc force distributions of the plate being welded. A relationship between the bead dimension and the arc force distributions was established. The sensor information was used to establish a relationship between welding current and arc force. Arc force sensor have shown to be one of the most sophisticated technique to monitor perturbations that occurred during robotic arc welding process.

  • PDF

구기자의 가지 및 열매의 특성에 관한 연구 (Physical Characteristics of Stem and Fruit of Lycium Chinense Mill)

  • 서정덕;허윤근;이상우
    • Journal of Biosystems Engineering
    • /
    • 제24권4호
    • /
    • pp.365-372
    • /
    • 1999
  • Physical characteristics of stem (ile., length and diameter) and branch, and detachment force of mature and immature fruits of 12 species of the Lycium chinese Mill at a cultivar were determined. The number of stems and branches were counted after the first and second pruning of each plant. Length and diameter of the stem were average of 113.5 cm and 9.5 mm for 12 species of the Lycium chinese Mill, respectively. Average number of stem and number of branch after the first and second pruning in each plant were 5, 30, and 61, respectively. Diameter of major and minor axis of the fruit was average of 13.8mm and 8.3mm, respectively, and the sphericity of fruits was average of 0.7 for 12 species of Lycium chinese Mill. Detachment force of mature and immature fruits was average of 1 N and 2.7 N, respectively, for 12 species of the Lycium chinese Mill. The maximum and minimum detachment force of the mature fruits was 2.06 N and 0.39 N, respectively, and that of the immature fruits was 3.72 N and 1.27 N, respectively. The force-weight ratio showed a decreasing trend as the weight of fruit increasing for all samples.

  • PDF

고정성 교정장치를 이용한 치아이동시 발생되는 마찰력 (FRICTIONAL FORCES IN THE FIXED ORTHODONTIC APPLIANCE DURING TOOTH MOVEMENT)

  • 조명숙;김종철
    • 대한치과교정학회지
    • /
    • 제20권2호
    • /
    • pp.409-417
    • /
    • 1990
  • Tooth movement would be impeded by frictional force arised between archwire and tube, bracket or elastics in the fixed orthodontic appliances, which could be changed variably by such several factors as the contact area, normal (perpendicular) force and the condition of contact surface. There were many literatures about frictional force in the orthodontic region, but different results were obtained from little controlled research so that was very difficult in clinical application. Therefore we have reviewed comprehensively previous literatures about frictional force and thus several results were obtained as follows: 1. For use species of the orthodontic wire, frictional force was influenced mainly by surface roughness of wire in the absence of binding, while that was influenced mainly by normal force in high binding angulation. 2. For the cross-section and diameter of the wire, the contact area influenced mainly on frictional force in the absence of binding, while wire stiffness influenced mainly on frictional force in high binding angulation. 3. The greater the bracket width, the greater frictional force, and frictional force of the plastic bracket was larger than that of the metal bracket. 4. For ligation type, frictional force of the stainless steel ligation was larger than that of the elastic ligation, and frictional force was directly proportional to ligation force. 5. Variable frictional force were occured from the saliva combined with such another factors as normal force and mode of surface oxide et al.

  • PDF

백서 하악골 후방견인후의 하악골 성장에 관한 실험적 연구 (THE GROWTH OF RAT MANDIBLES FOLLOWING MANDIBULAR RETRACTIVE FORCE)

  • 경희문
    • 대한치과교정학회지
    • /
    • 제19권3호
    • /
    • pp.15-33
    • /
    • 1989
  • The purpose of this study was to investigate changes of the mandible of a growing rat when they are subjected to a retractive force and those after removal of the retractive force. The experimental animals were Sprague-Dawley male rats of four weeks of age. A mandible was retracted with 50 grams of force on each side in the posterior and superior direction for 8 hours per day. The animals were sacrificed after 1 week, 2-week and 4-week force application, and after 4-week force application-4-week force removal period. The changes of rat mandibular growth following retractive force on the growing rat mandible were observed histologically and biometrically. The findings were as follows ; 1. Histologically, the thickness of the condylar cartilage was slightly reduced in the anterosuperior region with the retractive force. However, in the group of 4-week force application-4-week force removal, there was no significant difference in the thickness of the condylar cartilage. 2. There were no significant histological changes in the articular disk and glenoid fossa through the experimental period. 3. The length and anterior height of the mandible subjected to the retractive force were significantly smaller and greater than those of the control group. 4. There were no significant differences in the mandibular length between 4-week force application - 4-week force removal and the control group. 5. It was concluded that a mandibular retractive force produced inhibitory effects in the growth of the mandible, but that these effects were not sustained during mandibular growth in this experimental model.

  • PDF

온도가 세척계의 표면장력에 미치는 영향(제1보) -세액의 표면장력 성분변화를 중심으로- (Effect of Temperature on the Surface Tensions in the Detergency System(I) -Change of Surface Tension Components of Washing Liquids-)

  • 채정희;김성련
    • 한국의류학회지
    • /
    • 제17권4호
    • /
    • pp.511-517
    • /
    • 1993
  • Changes of the surface and interface tension with temperature for washing liquids and alkanes were measured by FACE surface tensiometer. Using the extended Fowkes' equation, the dispersion and polar force components of the surface tension were estimated. The results were as follows : 1. The surface tensions of washing liquids and alkanes decreased almost linearly with the increase of temperature. 2. The interface tensions of 0.25% DBS/alkane increased slowly with the increase of temperature. In the case of nonionic surfactant solutions, however, the interface tensions with alkanes varied with the number of hydrophilic ethylene oxide(EO) groups. 3. Of the surface tension of water at $20^{\circ}C$, the dispersion force component was 25.3 dyn/cm and the polar force component was 47.8 dyn/cm. As the temperature increased, both the polar and dispersion force components decreased in a similar fashion. 4. The dispersion force component of surface tension of 0.25% DBS solution was 30.0 dyn/cm, and the polar force component was 2.2 dyn/cm at $20^{\circ}C$. The two components decreased with the increase of temperature. 5. As the temperature increased, the dispersion force component of surface tension decreased and the polar force component increased significantly for 0.25% NPPG-7.5EO solution. In the case of 025% NPPG-10EO, both the dispersion and polar force components decreased slowly, but the polar force component is expected to increase from $60^{\circ}C$. However, the polar force component of surface tension decreased with the increase of temperature for 025% NPPG-15EO solution, and at the temperature higher than $60^{\circ}C$ the surface tension is expected to be composed of only dispersion force component.

  • PDF

유지관리기 치주환자의 전치 및 소구치에서 잔존 치조골량에 따른 교합력의 비교 연구 (A comparative study of bite force associated with remaining bone level in anterior and premolar teeth at periodontal maintenance phase)

  • 송규원;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.643-653
    • /
    • 2002
  • Periodontal supporting tissue goes through destruction by chronic inflammatory periodontal disease as two aspect. One is qualitive aspect such as alteration of periodontium, the other is quantitative aspect such as alveolar bone loss. According to many authors, PDL is responsible for biting force, and there are two mean. for measuring PDL's function - mobility test and biting force test. This study was conducted to compare the biting force with remaining bone level, that is, quantitative aspect of periodontium, in anterior and premolar teeth at periodontal maintenance phase. 17 patients on periodontal maintenance phase during 6 months at minimum were selected for this study. For the same condition, 4 anterior, canine, premolar teeth were tested by MPM-3000 bite-force register at the same time(a.m.l0-12), the same position, the same posture, by the same examiner. Patients of TMI), ill-fitting pros thesis, general disease, malocclusion and the teeth of TFO, absence of opposing teeth, malposition were excluded. Remaining bone level was measured on the panorama X-ray film through 5 level from 1mm below CEJ to root apex. Teeth were examined twice, and bigger one was selected. If the values showed large difference. examinatin was re-done and the mean was selected. The results were as follows ; 1. In the 4 anterior group, as the remaining bone is decreased, the average of maximal biting force is decreased. Especially, at 3/5 bone level, maximal biting force is decreased significantly(p<0.01). 2. In the canine group, as the remaining bone is decreased, the average of maximal biting force is decreased. Especially, at 2/5 bone level, maximal biting force is decreased significantly(p<0.01). 3. In the premolar group, as the remaining bone is decreased, the average of maximal biting force is decreased. Especially, at 3/5 bone level, maximal biting force is decreased significantly(p<0.05). From the results of this study, clinicians could utilize these efficiently when they have to determine the proper restorative materials, time for tooth extraction, treatment plan, prognosis.

주관절 굴곡근의 근피로가 힘 재현 감각에 미치는 영향 (Influence of Muscle Fatigue on the Sensing of Force Reproduction in Elbow Flexors)

  • 이원휘;하성민;김용욱;오재섭
    • 한국전문물리치료학회지
    • /
    • 제14권3호
    • /
    • pp.16-22
    • /
    • 2007
  • The purpose of this study was to determine the influence of muscle fatigue in elbow flexors on the sense of force reproduction. Fifteen healthy subjects were recruited for this study. Maximum voluntary force (MVF) of elbow flexor muscles was measured by a digital tensiometer. Force errors were measured to test accuracy of the sense of force reproduction in elbow flexors. The subject was required to flex the elbow joint, to maintain and concentrate on about 20% of the MVF target force under visual feedback for 3 seconds. After a 5 second period rest, the subject was asked to duplicate the target force actively. Muscle fatigue was evoked with isometric contraction of the elbow flexors. Isometric contraction was continued until a 50% drop in MVF. The difference, in kilogram between the target force and the reproduced force was calculated for measuring force error. Force errors were compared between the non-fatigued condition and the fatigued condition by the paired t-test. Force errors were significantly increased in the fatigued condition compare to non-fatigued condition. This result suggests that the sense of force reproduction can be disturbed by localized muscle fatigue.

  • PDF

제 5힘과 중성자성의 구조 (ON THE FIFTH FORCE AND THE STRUCTURE OF NEUTRON STAR)

  • 송두종;이해심
    • Journal of Astronomy and Space Sciences
    • /
    • 제11권1호
    • /
    • pp.115-130
    • /
    • 1994
  • 구성물질에 영향을 받는 제5힘이 존재할 경우 별의 특성과 구조를 중성자성을 대상으로 살펴보았다. 중성자만으로 이루어진 축퇴된 중성자성의 크기, 질량및 구조는 변형된 토마스-페르미 방정식의 해로서 계산할 수 있고, 제5힘이 없을 경우와 같이 새로운 중성자성의 크기, 질량 및 구조가 제5힘의 상수와 중력상수 $\alpha$에 영향을 받고 있음을 알았다. 극히 상대론적인 경우 새로운 중성자성의 특성 질량인 챤드라세카르 질량, $M_{ch}\simeq(1-\alpha)^{-3/2}{m_{pl}}^3/m^2$ 은 물리법칙의 상수만으로 결정되는 것을 확인할 수 있었다. 그러나 실험 결과의 한계안에서 새로운 중성자성의 크기와 질랴의 변화량은 각각 $\alpha$/2 와 3$\alpha$/2 정도였다.

  • PDF

Change of Isometric Contractile Force and Muscle Activity Applying Heat according to the Time on Biceps Brachii Muscle

  • Jeon, Jae Keun;Kim, Sang Soo;Kang, Da Haeng;Kim, Bo Kyoung;Koo, Ja Pung;Moon, Ok Kon;Lee, Joon Hee
    • 국제물리치료학회지
    • /
    • 제4권1호
    • /
    • pp.505-509
    • /
    • 2013
  • This study has investigated the effect of isometric contractile force and muscle activity applying sperficial heat according to the time from the biceps brachii muscle. In this study, 20 university students participants without musculoskeletal and neurological disorders. By applying a hot pack 5min, 10min, 20min and 30min respectively. After that measurement are skin temperature, contractile force and muscle activity. Skin temperature of the hot 5 min applied that rapidly changing. Increasing the time it takes to apply a variance has been reduced(p<.001). Isometric contractile force was not statistically significant but highest when applying the hot pack 5 minutes and lowest when applying the hot pack 30 minutes(p<.001). Muscle activity and median frequency was highest when applying the hot pack 5 minutes. To analyze the above results, it was found that isometric contractile force and muscle activity changed according to the applying time. These result lead us to the conclusion that this study will be more evidence for changes in muscle contraction to apply hot pack on clinic.

Spring의 lumen size와 helical coil 형성 위치 변화가 교정력에 미치는 영향 (Impact of Lumen Size and Helical Coil Place Change in Spring on Orthodontic Force)

  • 이규선;이선경;김복동
    • 대한치과기공학회지
    • /
    • 제33권4호
    • /
    • pp.331-337
    • /
    • 2011
  • Purpose: The purpose of this study was to impact of force system change in finger spring that add helical coil one round on orthodontic force. Methods: The following conclusions were drawn from the experiment conducted after bending 90 samples with a CNC wire forming machine while changing the height and lumen size to 1mm - 3mm - 5mm and 2mm - 3mm - 4mm respectively in the coil of the force system in finger spring added with one wheel of helical coil of 18-8 stainless steel round wire (${\Phi}0.5mm$, spring hard) from Jinsung Co. in domestic market under the following conditions: Laboratory name = Instron 5942; Temperature($deg^{\circ}C$) = 18.00; Humidity(%) = 50.00; Rate 1 = 10.00000 mm/min; Compressive extension = 5.0mm. Results: When Coil height is 1, 3, 5mm and lumen size is 2, 3, 4mm reduce finger spring as mean value of compressive extension occasion maximum load(mN) increases as coil height rises, and lumen size grows to 5.0mm. And was expose that compressive load(mN) increases as coil position of finger spring rises and increase as lumen size is decrescent. Conclusion: As the adherence height of coil was raised from 1mm through 3mm to 5mm, compressive load increased. As the lumen size increased from 2mm through 3mm to 4mm, compressive load decreased. Therefore, these results suggest that it is desirable to lower the coil height and enlarge the lumen size to enhance the biomechanical efficiency of finger spring when manufacturing the finger spring for removable orthodontic devices.