• Title/Summary/Keyword: 4D Reconstruction

Search Result 338, Processing Time 0.024 seconds

비타민 D$_3$와 인산칼슘의 토끼 대퇴골 골절치유 효과에 대한 골수강내 정맥 조영술 (Intraosseous Phlebography for Determination of the Effect of Vitamin D$_3$ and Calcium Phosphate on Fractured Bone Healing in Rabbit)

  • 엄기동;성재기
    • 한국임상수의학회지
    • /
    • 제10권2호
    • /
    • pp.185-192
    • /
    • 1993
  • Intraosseous phlebography was performed to determine the healing effect of the dosing treated with vitamin-D$_3$ and/or calcium phosphate on the fractured bone in male rabbits. Femoral shafts of 16 adult male rabbits were fractured and these animals were divided into 3 treated groups and 1 control group l. The 1st treated group of rabbits was dosed with vitamin-D$_3$(VD), the 2nd treated group of rabbits was given calcium phosphate(CP), and the 3.d treated group of rabbits received vitamin-D$_3$ and calcium phosphate. The control group of rabbits was dosed with saline alone. Radiographs were taken weekly in each rabbit over 6 weeks period and the results obtained were as follows. 1. Sinusoidal vein was visualized at 3rd week in eve animal received CP and VC, at 5 week in animals received VD and in control animals. 2. Main nutrient vein was observed more clearly in treated groups than in control group of animals. 3. These results indicate that venous reconstruction of the fractured bone in groups of rabbits received CP and VC was earlier and more complete than those of other groups of rabbits. 4. Therefore, intraosseous phlebography is suitable for determination of the bone healing effect of vitamin-D$_3$ and/or calcium phosphate in femoral fractured rabbits.

  • PDF

Wide baseline 카메라 기반의 효과적인 실내공간 감시시스템 (An effective indoor video surveillance system based on wide baseline cameras)

  • 김응창;김승균;최강아;정준영;고성제
    • 전기전자학회논문지
    • /
    • 제14권4호
    • /
    • pp.317-323
    • /
    • 2010
  • 특정 공간 내에서의 보안에 대한 효과적인 방법으로써 비디오 영상 감시 시스템(video surveillance system)이 널리 사용되고 있다. 그러나, 단일 카메라 기반의 시스템에서는 한정된 카메라 시야(field of view)의 제약으로 인하여 대상 영역을 완전히 커버하지 못하는 문제점이 있다. 본 논문에서는 이러한 단일 카메라 기반의 비디오 영상감시 시스템의 단점을 보완하기 위한 복수의 wide baseline 고정 카메라를 이용한 시스템을 개발, 구현하였다. 제안하는 시스템에서는 복수의 고정 카메라로부터 움직이는 물체를 강건하게 검출하기 위하여, 코드북(codebook) 기반의 물체 검출 알고리즘과 모폴로지(morphology)가 사용되고, 3D 재구성을 통해 검출된 물체의 궤적을 계산한다. 실험결과로부터 제안하는 시스템은 물체를 성공적으로 추출하여, 신뢰도 있는 이동궤적을 top view 형태로 제공함 을 확인할 수 있다.

CareDose 4D 사용 시 동일한 스캔조건에서 조직기반설정을 다르게 적용함에 따른 선량 비교: 성인과 소아팬텀 연구 (Radiation Dose Comparison according to Different Organ Characteristics at Same Scan Parameters Using CareDose 4D: An Adult and Pediatric Phantom Evaluation)

  • 공효금;이기백
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권4호
    • /
    • pp.271-277
    • /
    • 2019
  • CareDose 4D which is the Siemens's Automatic Exposure Control (AEC) can adjust the level of radiation dose distribution which is based on organ characteristic unlike other manufacturer's AEC. Currently, a wide scan range containing different organs is sometimes examined at once (defined as one scan). The purpose of this study was to figure out which organ characteristic option is suitable when one scan method is utilized. Two types of anthropomorphic phantoms were scanned in the same range which were from frontal bone to carina level according to three different organ characteristics such as Thorax, Abdomen, and Neck. All scans and image reconstruction parameters were equally applied and radiation dose were compared. Radiation dose with Thorax organ characteristic was lower than that with Neck. Also, that with Abdomen oran characteristic was lower than Thorax. There were significant differences in radiation dose according to different organ characteristics at the same parameters (P<0.05). Usage of Neck organ characteristic had a result of the highest radiation dose to all phantom. On the other hand, utilization of Abdomen organ characteristic showed the lowest radiation dose. As a result, it is desirable to set appropriate organ characteristic according to examined body part when you checkup patients. Also, when you implement one scan method, selection of Abdomen-based organ characteristic has reduced more radiation dose compared with two different organ characteristic.

Preliminary Report of Three-Dimensional Reconstructive Intraoperative C-Arm in Percutaneous Vertebroplasty

  • Shin, Jae-Hyuk;Jeong, Je-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권2호
    • /
    • pp.120-123
    • /
    • 2012
  • Objective : Percutaneous vertebroplasty (PVP) is usually carried out under three-dimensional (2D) fluoroscopic guidance. However, operative complications or bone cement distribution might be difficult to assess on the basis of only 2D radiographic projection images. We evaluated the feasibility of performing an intraoperative and postoperative examination in patients undergoing PVP by using three-dimensional (3D) reconstructive C-arm. Methods : Standard PVP procedures were performed on 14 consecutive patients by using a Siremobil Iso-$C^{3D}$ and a multidetector computed tomography machine. Post-processing of acquired volumetric datasets included multiplanar reconstruction (MPR) and surface shaded display (SSD). We analyzed intraoperative and immediate postoperative evaluation of the needle trajectory and bone cement distribution. Results : The male : female ratio was 2 : 12; mean age of patients, 70 (range, 77-54) years; and mean T score, -3.4. The mean operation time was 52.14 min, but the time required to perform and post-process the rotational acquisitions was 7.76 min. The detection of bone cement distribution and leakage after PVP by using MPR and SSD was possible in all patients. However, detection of the safe trajectory for needle insertion was not possible. Conclusion : 3D rotational image acquisition can enable intra- or post-procedural assessment of vertebroplasty procedures for the detection of bone cement distribution and leakage. However, it is difficult to assess the safe trajectory for needle insertion.

3D Light-Sheet Fluorescence Microscopy of Cranial Neurons and Vasculature during Zebrafish Embryogenesis

  • Park, Ok Kyu;Kwak, Jina;Jung, Yoo Jung;Kim, Young Ho;Hong, Hyun-Seok;Hwang, Byung Joon;Kwon, Seung-Hae;Kee, Yun
    • Molecules and Cells
    • /
    • 제38권11호
    • /
    • pp.975-981
    • /
    • 2015
  • Precise 3D spatial mapping of cells and their connections within living tissues is required to fully understand developmental processes and neural activities. Zebrafish embryos are relatively small and optically transparent, making them the vertebrate model of choice for live in vivo imaging. However, embryonic brains cannot be imaged in their entirety by confocal or two-photon microscopy due to limitations in optical range and scanning speed. Here, we use light-sheet fluorescence microscopy to overcome these limitations and image the entire head of live transgenic zebrafish embryos. We simultaneously imaged cranial neurons and blood vessels during embryogenesis, generating comprehensive 3D maps that provide insight into the coordinated morphogenesis of the nervous system and vasculature during early development. In addition, blood cells circulating through the entire head, vagal and cardiac vasculature were also visualized at high resolution in a 3D movie. These data provide the foundation for the construction of a complete 4D atlas of zebrafish embryogenesis and neural activity.

PET/CT 3차원 영상 획득에서 부분용적효과 감소를 위한 재구성법의 최적화 (The Optimization of Reconstruction Method Reducing Partial Volume Effect in PET/CT 3D Image Acquisition)

  • 홍건철;박선명;곽인석;이혁;최춘기;석재동
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.13-17
    • /
    • 2010
  • PVE는 PET/CT 3D 영상 획득에서 발생되는 것으로 평가값이 저평가되어 영상의 정확도를 떨어뜨리는 현상이다. 특히 이는 병소의 크기가 작고 분해능이 저하될수록 더 큰 오차를 초래하여 검사 결과에 영향을 줄 수 있다. 본 연구는 PVE에 영향을 줄 수 있는 매개변수의 변화를 이용하여 최적의 영상 재구성법을 알아보고자 한다. GE Discovery STE16 장비에서 NEMA 2001 IEC phantom을 이용하여 각기 다른 크기의 구체(직경 37, 28, 22, 17, 13, 10 mm)에 $^{18}F$-FDG를 열소와 배후방사능비 4:1로 주입하여 10분간 영상을 획득하였다. 재구성은 반복재구성법(iterative reconstruction)을 사용하였으며, 반복 횟수(iteration) 2~50회, 부분집합 수(subset number) 1~56개로 변화를 주었다. 분석은 영상의 구체부분에 관심영역(ROI)을 설정하고 최대 표준섭취계수($SUV_{max}$)를 이용하여 백분율 차이(% difference)와 신호대잡음비(SNR)를 산출하였다. 반복 횟수 2, 6, 13, 30, 50회 변화를 준 10 mm 구체의 $SUV_{max}$는 2.32, 3.60, 3.88, 3.88, 3.90이고, SNR은 0.36, 0.49, 0.47, 0.43, 0.41이었으며, 백분율 차이는 58.9, 38.5, 34.8, 35.7, 35.4%로 측정되었다. 또한 6회로 고정한 반복 횟수에 2, 5, 8, 20, 56으로 부분집합 수를 변화시킨 평균 $SUV_{max}$는 10mm의 구체에서 1.46, 3.10, 3.10, 3.48, 3.78로 측정되었으며, SNR은 0.19, 0.30, 0.40, 0.48, 0.45로 나타났다. 또한 각 구체의 SNR의 합은 2.73, 3.38, 3.64, 3.63, 3.38로 측정되었다. 반복 횟수 6회부터 20회까지는 평균 백분율 차이($73{\pm}1%$)와 평균 SNR ($3.47{\pm}0.09$)은 비슷한 값을 나타내었으며, 20회 이상에서는 noise의 영향으로 SUV가 저평가되는 현상이 증가하였다. 또한 동일한 반복 횟수의 경우에 부분집합 값의 변화에서 SNR은 8회부터 20회가 높은 구간($3.63{\pm}0.002$)으로 나타났다. 따라서 작은 병소의 PVE를 줄이기 위해서는 재구성 시간을 고려하여 반복 횟수 6회, 부분집합 수 8~20회에서 PVE를 가장 저감할 수 있다.

  • PDF

동결건조 양막과 동적배양법을 이용한 토끼 각막 상피층의 재구성 (Reconstruction of Rabbit Corneal Epithelium using Lyophilized Amniotic Membrane and Dynamic Culture Method)

  • 안재일;장인근;신연호;서영권;윤희훈;윤문영;김재찬;송계용;이희구;양은경;김기호;박정극
    • KSBB Journal
    • /
    • 제20권4호
    • /
    • pp.305-310
    • /
    • 2005
  • 동결건조 양막과 자체 제작한 양막 지지체를 이용한 동적 배양법을 통하여 토끼 각막 상피층의 재구성 효과를 검토하였다. 각막 상피세포는 토끼 각막 윤부로부터 분리 배양 후 동결보존하여 사용하였고, 세포증식은 10계대까지 가능하였다. 동적배양을 한 경우가 정치배양보다 기저층이 잘 형성되었고, 세포 증식과 분화를 촉진하여 치밀한 상피층을 형성하였다. 이렇게 재구성된 각막 상피층은 심한 각막 손상을 입은 환자의 조직 이식에 좋은 생체외 모델이 될 것으로 기대된다.

웹 기반의 입체 동영상 통신을 위한 3차원 입출력 시스템의 최적화 구현 (Implementation of Optimized 3D Input & Output Systems for Web-based Real-time 3D Video Communication)

  • 고정환;이정석;안영환
    • 전자공학회논문지 IE
    • /
    • 제43권4호
    • /
    • pp.105-114
    • /
    • 2006
  • 본 논문에서는 IEEE 1394 카메라, Intel Xeon 서버 시스템, Microsoft DirectShow기술을 이용하는 웹 기반의 실시간 입체 동영상 통신을 위한 3차원 입출력 시스템을 제안하고 그 구성요소인 스테레오 카메라 시스템, 3D 디스플레이 시스템, 신호처리 시스템을 최적화하기 위한 조건들을 분석하였다. 즉, 웹 기반의 다시점 3차원 디스플레이 응용에 적합하도록 각 구성요소의 편수 조건에 맞추어 입출력 장치를 선택하고 이들을 조합하여 하나의 3차원 입체영상통신 시스템을 구성하였다. 그리고 제안된 시스템은 Visual C++.Net 환경에서 DirectX 9.1 SDK를 사용하여 최적화 구현하였다. 실험결과 서버 시스템에서 자연스럽고 임장감 있는 다시점의 실시간 3차원 입체 동영상을 관찰할 수 있었고 또한, 클라이언트 시스템에서도 전송된 영상들에 대하여 디스플레이를 통해 3차원 입체 영상을 관찰함으로써 웹 기반의 실시간 인격 3차원 입체 동영상 통신 시스템의 실질적인 응용 가능성을 제시하였다.

나무나이테를 이용한 설악산 지역의 4월~8월 총강수량 복원 (Reconstruction of April-August Precipitation in Mt. Sorak Region from Tree Rings)

  • 박원규;서정욱;;김요정;한수원
    • 한국제4기학회지
    • /
    • 제15권1호
    • /
    • pp.47-52
    • /
    • 2001
  • 설악산 백담산장 (해발고 400m) 지역에서 자라는 소나무를 이용하여 141년 (A.D. 1858∼1998)간의 나무나이테(연륜) 연대기를 작성하여 4월∼8월 총강수량을 복원하였다. 복원한 결과 1880∼1887년, 1893∼1901년, 1922∼1938년은 건조기로 나타났으며, 1906∼1918년은 습윤기로 나타났다. 장기간 변동으로 보았을 때, 19세기말과 20세기초는 20세기 후반기보다 건조하였다. 전기간에 걸친 가뭄주기는 4.14년과 3.16년으로 분석되어 장주기보다 단주기 변화가 우세하였다.

  • PDF

Three-Dimensional Video Microscopy: Potential for Improved Ergonomics without Increased Operative Time?

  • Yasmina Samaha;Edward Ray
    • Archives of Plastic Surgery
    • /
    • 제50권1호
    • /
    • pp.125-129
    • /
    • 2023
  • Three-dimensional (3D) video exoscopes are high-magnification stereo cameras that project onto monitors mounted in the operating room, viewable from different angles. Outside of plastic surgery, exoscopes have been shown to successfully improve the ergonomics of microsurgery, though sometimes with prolonged operating times. We compare a single surgeon's early experience performing free flap procedures from 2020 to 2021 using either a binocular microscope or a 3D video exoscope. Ten procedures were performed with the standard operating microscope and 8 procedures with the 3D exoscope. The microsurgeon, having minimal prior experience using an exoscope, reported less neck discomfort following the free flap procedures performed with the exoscope compared with the binocular surgical microscope. Total average operating time was comparable between the standard surgical microscope and the 3D exoscope (13.7 vs. 13.4 hours, p = 0.34). Our early experience using a 3D exoscope in place of a standard optical microscope demonstrated that the exoscope shows promise, offering an ergonomic alternative during microvascular reconstruction without increasing overall operating times. Future studies will compare free flap ischemia time between cases performed using the exoscope and the conventional binocular microscope. Medical Subject Headings authorized following words: free tissue flaps; operating rooms; ergonomics; microsurgery.