• Title/Summary/Keyword: 4D Reconstruction

Search Result 338, Processing Time 0.026 seconds

Long-term Follow-up for Type 2 Diabetes Mellitus after Gastrectomy in Non-morbidly Obese Patients with Gastric Cancer: the Legitimacy of Onco-metabolic Surgery

  • Lee, Tae-Hoon;Lee, Chang Min;Park, Sungsoo;Jung, Do Hyun;Jang, You Jin;Kim, Jong-Han;Park, Seong-Heum;Mok, Young-Jae
    • Journal of Gastric Cancer
    • /
    • v.17 no.4
    • /
    • pp.283-294
    • /
    • 2017
  • Purpose: This study primarily aimed to investigate the short- and long-term remission rates of type 2 diabetes (T2D) in patients who underwent surgical treatment for gastric cancer, especially patients who were non-obese, and secondarily to determine the potential factors associated with remission. Materials and Methods: We retrospectively reviewed the clinical records of patients with T2D who underwent radical gastrectomy for gastric cancer, from January 2008 to December 2012. Results: T2D improved in 39 out of 70 (55.7%) patients at the postoperative 2-year follow-up and 21 of 42 (50.0%) at the 5-year follow-up. In the 2-year data analysis, preoperative body mass index (BMI) (P=0.043), glycated hemoglobin (A1C) level (P=0.039), number of anti-diabetic medications at baseline (P=0.040), reconstruction method (statistical difference was noted between Roux-en-Y reconstruction and Billroth I; P=0.035) were significantly related to the improvement in glycemic control. Unlike the results at 2 years, the 5-year data analysis revealed that only preoperative BMI (P=0.043) and A1C level (P=0.039) were statistically significant for the improvement in glycemic control; however, the reconstruction method was not. Conclusions: All types of gastric cancer surgery can be effective in short- and long-term T2D control in non-obese patients. In addition, unless long-limb bypass is considered in gastric cancer surgery, the long-term glycemic control is not expected to be different between the reconstruction methods.

Occluded Object Reconstruction and Recognition with Computational Integral Imaging (집적 영상을 이용한 가려진 표적의 복원과 인식)

  • Lee, Dong-Su;Yeom, Seok-Won;Kim, Shin-Hwan;Son, Jung-Young
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.4
    • /
    • pp.270-275
    • /
    • 2008
  • This paper addresses occluded object reconstruction and recognition with computational integral imaging (II). Integral imaging acquires and reconstructs target information in the three-dimensional (3D) space. The reconstruction is performed by averaging the intensities of the corresponding pixels. The distance to the object is estimated by minimizing the sum of the standard deviation of the pixels. We adopt principal component analysis (PCA) to classify occluded objects in the reconstruction space. The Euclidean distance is employed as a metric for decision making. Experimental and simulation results show that occluded targets are successfully classified by the proposed method.

Long-Term Outcomes of Modified Cone Reconstruction for Ebstein's Anomaly in Pediatric Patients in a Single Center

  • Ilkun Park;Tae-Gook Jun;Ji-Hyuk Yang;I-Seok Kang;June Huh;Jinyoung Song;Ok Jeong Lee
    • Korean Circulation Journal
    • /
    • v.54 no.2
    • /
    • pp.78-90
    • /
    • 2024
  • Background and Objective: We aimed to investigate long-term clinical and echocardiographic outcomes, including tricuspid valve durability, annular growth, and left ventricular reverse remodeling, after modified cone reconstruction in patients with Ebstein's anomaly. Methods: This was a retrospective analysis of all pediatric patients who underwent modified cone reconstruction for Ebstein's anomaly at a single tertiary center between January 2005 and June 2021. Results: A total of 14 pediatric patients underwent modified cone reconstruction for Ebstein's anomaly; the median age was 5.8 years (range, 0.01-16.6). There were three patients (21.4%) with Carpentier type B, ten patients with Carpentier type C (71.4%), and one patient with Carpentier type D (7.1%). There was no early or late mortality, arrhythmia, or readmission for heart failure at a 10-year follow-up. There were no cases of more than mild tricuspid stenosis or more than moderate tricuspid regurgitation during the study period, except for one patient with severe tricuspid regurgitation who underwent reoperation. The z value for tricuspid valve annular size significantly decreased immediately after the operation (2.46 vs. -1.15, p<0.001). However, from 1 year to 7 years after surgery, the z values were maintained between -1 and +1. Left ventricular end-systolic volume, end-diastolic volume, and stroke volume increased after surgery and remained elevated until seven years postoperatively. Conclusions: Ebstein's anomaly in children can be repaired by modified cone reconstruction with low mortality and morbidity, good tricuspid valve durability, and annular growth relative to somatic growth.

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF

Three-dimensional computer navigation in the reconstruction of complex unilateral orbital fractures: evaluation and review of applications

  • Parampreet Singh Saini;Rajesh Kumar;Manu Saini;Tarush Gupta;Sunil Gaba;Ramesh Kumar Sharma
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.4
    • /
    • pp.161-170
    • /
    • 2024
  • Background: The eyes are the central aesthetic unit of the face. Maxillofacial trauma can alter facial proportions and affect visual function with varying degrees of severity. Conventional approaches to reconstruction have numerous limitations, making the process challenging. The primary objective of this study was to evaluate the application of three-dimensional (3D) navigation in complex unilateral orbital reconstruction. Methods: A prospective cohort study was conducted over 19 months (January 2020 to July 2021), with consecutive enrollment of 12 patients who met the inclusion criteria. Each patient was followed for a minimum period of 6 months. The principal investigator carried out a comparative analysis of several factors, including fracture morphology, orbital volume, globe projection, diplopia, facial morphic changes, lid retraction, and infraorbital nerve hypoesthesia. Results: Nine patients had impure orbital fractures, while the remainder had pure fractures. The median orbital volume on the normal side (30.12 cm3; interquartile range [IQR], 28.45-30.64) was comparable to that of the reconstructed orbit (29.67 cm3; IQR, 27.92-31.52). Diplopia improved significantly (T(10)= 2.667, p= 0.02), although there was no statistically significant improvement in globe projection. Gross symmetry of facial landmarks was achieved, with comparable facial width-to-height ratio and palpebral fissure lengths. Two patients reported infraorbital hypoesthesia at presentation, which persisted at the 6-month follow-up. Additionally, five patients developed lower lid retraction (1-2 mm), and one experienced implant impingement at the infraorbital border. Conclusion: Our study provides level II evidence supporting the use of 3D navigation to improve surgical outcomes in complex orbital reconstruction.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Gait Study on the Normal and ACL Deficient Patients After Ligament Reconstruction Surgery Using Chaos Analysis Method (전방십자인대 재건수술 환자와 정상인의 보행 연구)

  • Ko Jae-Hun;Moon Byung-Young;Suh Jeung-Tak;Son Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.4 s.247
    • /
    • pp.435-441
    • /
    • 2006
  • The anterior cruciate ligament(ACL) is an important stabilizer of knee joint. The ACL injury of knee is common and a serious ACL injury leads to ligament reconstruction surgery. Gait analysis is essential to identify knee condition of patients who display abnormal gait. The purpose of this study is to evaluate and classify knee condition of ACL deficient patients using a nonlinear dynamic method. The nonlinear method focuses on understanding how variations in the gait pattern change over time. The experiments were carried out for 17 subjects(l2 healthy subjects and five subjects with unilateral deficiency) walking on a motorized treadmill for 100 seconds. Three dimensional kinematics of the lower extremity were collected by using four cameras and KWON 3D motion analysis system. The largest Lyapunov exponent calculated from knee joint flexion-extension time series was used to quantify knee stability. The results revealed the difference between healthy subjects and patients. The deficient knee was significantly unstable compared with the contralateral knee. This study suggests an evaluation scheme of the severity of injury and the level of recovery. The proposed Lyapunov exponent can be used in rehabilitation and diagnosis of recoverable patients.

A algorithm development on optical freeform surface reconstruction (광학식 자유곡면 형상복원 알고리즘 개발)

  • Kim, ByoungChang
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.5
    • /
    • pp.175-180
    • /
    • 2016
  • The demand for accurate freeform apsheric surface is increasing to satisfy the optical performance. In this paper, we develop the algorithm for opto-mechatronics convergence, that reconstruct the surface 3D profiles from the curvarure data along two orthogonal directions. A synthetic freeform surface with 8.4 m diameter was simulated for the testing. The simulation results show that the reconstruction error is 0.065 nm PV(Peak-to-valley) and 0.013 nm RMS(Root mean square) residual difference. Finally the sensitivity to noise is diagnosed for probe position error, the simulation results proving that the suggested method is robust to position error.

Three Dimensional Reconstruction of Structural Defect of Thin Film Transistor Device by using Dual-Beam Focused Ion Beam and Scanning Electron Microscopy (집속이온빔장치와 주사전자현미경을 이용한 박막 트랜지스터 구조불량의 3차원 해석)

  • Kim, Ji-Soo;Lee, Seok-Ryoul;Lee, Lim-Soo;Kim, Jae-Yeal
    • Applied Microscopy
    • /
    • v.39 no.4
    • /
    • pp.349-354
    • /
    • 2009
  • In this paper we have constructed three dimensional images and examined structural failure on thin film transistor (TFT) liquid crystal display (LCD) by using dual-beam focused ion beam (FIB) and IMOD software. Specimen was sectioned with dual-beam focused ion beam. Series of two dimensional images were obtained by scanning electron microscopy. Three dimensional reconstruction was constructed from them by using IMOD software. The short defect between Gate layer and Data layer was found from the result of three dimensional reconstruction. That phenomena made the function of the gate lost and data signal supplied to the electrode though the Drain continuously. That signal made continuous line defect. The result of the three dimensional reconstruction, serial section, SEM imaging by using the FIB will be the foundation of the next advanced study.

Clinical Analysis of Video-assisted Thoracoscopic Spinal Surgery in the Thoracic or Thoracolumbar Spinal Pathologies

  • Kim, Sung-Jin;Sohn, Moon-Jun;Ryoo, Ji-Yoon;Kim, Yeon-Soo;Whang, Choong-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.293-299
    • /
    • 2007
  • Objective : Thoracoscopic spinal surgery provides minimally invasive approaches for effective vertebral decompression and reconstruction of the thoracic and thoracolumbar spine, while surgery related morbidity can be significantly lowered. This study analyzes clinical results of thoracoscopic spinal surgery performed at our institute. Methods : Twenty consecutive patients underwent video-assisted thoracosopic surgery (VATS) to treat various thoracic and thoracolumbar pathologies from April 2000 to July 2006. The lesions consisted of spinal trauma (13 cases), thoracic disc herniation (4 cases), tuberculous spondylitis (1 case), post-operative thoracolumbar kyphosis (1 case) and thoracic tumor (1 case). The level of operation included upper thoracic lesions (3 cases), midthoracic lesions (6 cases) and thoracolumbar lesions (11 cases). We classified the procedure into three groups: stand-alone thoracoscopic discectomy (3 cases), thoracoscopic fusion (11 cases) and video assisted mini-thoracotomy (6 cases). Results : Analysis on the Frankel performance scale in spinal trauma patients (13 cases), showed a total of 7 patients who had neurological impairment preoperatively : Grade D (2 cases), Grade C (2 cases), Grade B (1 case), and Grade A (2 cases). Four patients were neurologically improved postoperatively, two patients were improved from C to E, one improved from grade D to E and one improved from grade B to grade D. The preoperative Cobb's and kyphotic angle were measured in spinal trauma patients and were $18.9{\pm}4.4^{\circ}$ and $18.8{\pm}4.6^{\circ}$, respectively. Postoperatively, the angles showed statistically significant improvement, $15.1{\pm}3.7^{\circ}$ and $11.3{\pm}2.4^{\circ}$, respectively(P<0.001). Conclusion : Although VATS requires a steep learning curve, it is an effective and minimally invasive procedure which provides biomechanical stability in terms of anterior column decompression and reconstruction for anterior load bearing, and preservation of intercostal muscles and diaphragm.