• Title/Summary/Keyword: 4-Camera

Search Result 2,368, Processing Time 0.035 seconds

A 2-D Image Camera Calibration using a Mapping Approximation of Multi-Layer Perceptrons (다층퍼셉트론의 정합 근사화에 의한 2차원 영상의 카메라 오차보정)

  • 이문규;이정화
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.4
    • /
    • pp.487-493
    • /
    • 1998
  • Camera calibration is the process of determining the coordinate relationship between a camera image and its real world space. Accurate calibration of a camera is necessary for the applications that involve quantitative measurement of camera images. However, if the camera plane is parallel or near parallel to the calibration board on which 2 dimensional objects are defined(this is called "ill-conditioned"), existing solution procedures are not well applied. In this paper, we propose a neural network-based approach to camera calibration for 2D images formed by a mono-camera or a pair of cameras. Multi-layer perceptrons are developed to transform the coordinates of each image point to the world coordinates. The validity of the approach is tested with data points which cover the whole 2D space concerned. Experimental results for both mono-camera and stereo-camera cases indicate that the proposed approach is comparable to Tsai's method[8]. Especially for the stereo camera case, the approach works better than the Tsai's method as the angle between the camera optical axis and the Z-axis increases. Therefore, we believe the approach could be an alternative solution procedure for the ill -conditioned camera calibration.libration.

  • PDF

Analysis of Image and Development of UV Corona Camera for High-Voltage Discharge Detection (고전압 방전 검출용 자외선 코로나 카메라 개발 및 방전 이미지 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.69-74
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV image. UV camera developed a $6.4[^{\circ}]{\times}4.8[^{\circ}]$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. UV camera to measure the discharge count and the UV image was developed, compared with a commercial camera, there was no significant difference. In salt spray environments breakdown voltage was lower than the normal state, thereby discharging the image was rapidly growing phenomenon.

Preliminary Study of Performance Evaluation of a Dual-mode Compton Camera by Using Geant4 (Geant4 몬테칼로 전산모사 툴킷을 이용한 이중모드 컴프턴 카메라 최적화 설계 및 성능평가)

  • Park, Jin Hyung;Seo, Hee;Kim, Seoung Hoon;Kim, Young Soo;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.191-196
    • /
    • 2012
  • A double-scattering type Compton camera which is appropriate to imaging a high-energy gamma source has been developed for nuclear material surveillance at Hanyang University. The double-scattering type Compton camera can provide high imaging resolution; however, it has disadvantage of relatively low imaging sensitivity than existing single-scattering type Compton camera. In this study, we introduce a novel concept of a dual-mode Compton camera which incorporates two different types of Compton camera, i.e., single- and double-scattering type. The dual-mode Compton camera can operate high-resolution mode and high-sensitivity mode in a single system. To maximize its performance, the geometrical configuration was optimized by using Geant4 Monte Carlo simulation toolkit. In terms of imaging sensitivity, high-sensitivity mode had higher sensitivity than high-resolution mode up to 100 times while high imaging resolution of the double-scattering Compton camera was maintained.

Hybrid Stereoscopic Camera System (이종 카메라를 이용한 스테레오 카메라 시스템)

  • Shin, Hyoung-Chul;Kim, Sang-Hoon;Sohn, Kwang-Hoon
    • Journal of Broadcast Engineering
    • /
    • v.16 no.4
    • /
    • pp.602-613
    • /
    • 2011
  • In this paper, we propose a hybrid stereoscopic camera system which acquires and utilizes stereoscopic images from two different camera modules, the main-camera module and the sub-camera module. Hybrid stereoscopic camera can effectively reduce the price and the size of a stereoscopic camera by using a relatively small and cheap sub-camera module such as a mobile phone camera. Images from the two different camera modules are very different from each other in aspects of color, angle of view, scale, resolution and so on. The proposed system performs an efficient hybrid stereoscopic image registration algorithm that transforms hybrid stereoscopic images into normal stereoscopic images based-on camera geometry. As experimental results, the registered stereoscopic images and applications of the proposed system are shown to demonstrate the performance and the functionality of the proposed camera system.

4S-Van Design for Application Environment

  • Lee, Seung-Yong;Kim, Seong-Baek;Lee, Jong-Hun
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.106-110
    • /
    • 2002
  • 4S-Van is being developed in order to provide the spatial data rapidly and accurately. 4S-Van technique is a system for spatial data construction that is heart of 4S technique. Architecture of 4S-Van system consists of hardware integration part and post-processing part. Hardware part has GPS, INS, color CCD, camera, B/W CCD camera, infrared rays camera, and laser. Software part has GPS/INS integration algorithm, coordinate conversion, lens correction, camera orientation correction, and three dimension position production. In this paper, we suggest that adequate 4S-Van design is needed according to application environment from various test results.

  • PDF

Camera Calibration and Pose Estimation for Tasks of a Mobile Manipulator (모바일 머니퓰레이터의 작업을 위한 카메라 보정 및 포즈 추정)

  • Choi, Ji-Hoon;Kim, Hae-Chang;Song, Jae-Bok
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.4
    • /
    • pp.350-356
    • /
    • 2020
  • Workers have been replaced by mobile manipulators for factory automation in recent years. One of the typical tasks for automation is that a mobile manipulator moves to a target location and picks and places an object on the worktable. However, due to the pose estimation error of the mobile platform, the robot cannot reach the exact target position, which prevents the manipulator from being able to accurately pick and place the object on the worktable. In this study, we developed an automatic alignment system using a low-cost camera mounted on the end-effector of a collaborative robot. Camera calibration and pose estimation methods were also proposed for the automatic alignment system. This algorithm uses a markerboard composed of markers to calibrate the camera and then precisely estimate the camera pose. Experimental results demonstrate that the mobile manipulator can perform successful pick and place tasks on various conditions.

A Study on the Estimation of Camera Calibration Parameters using Cooresponding Points Method (점 대응 기법을 이용한 카메라의 교정 파라미터 추정에 관한 연구)

  • Choi, Seong-Gu;Go, Hyun-Min;Rho, Do-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.4
    • /
    • pp.161-167
    • /
    • 2001
  • Camera calibration is very important problem in 3D measurement using vision system. In this paper is proposed the simple method for camera calibration. It is designed that uses the principle of vanishing points and the concept of corresponding points extracted from the parallel line pairs. Conventional methods are necessary for 4 reference points in one frame. But we proposed has need for only 2 reference points to estimate vanishing points. It has to calculate camera parameters, focal length, camera attitude and position. Our experiment shows the validity and the usability from the result that absolute error of attitude and position is in $10^{-2}$.

  • PDF

CHARACTERISTICS AND PERFORMANCE OF A FAST CCD CAMERA: DALSTA IM30P

  • SEO YOUNG-MIN;PARK KI-WOONG;CHAE JONGCRUL
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.4
    • /
    • pp.185-191
    • /
    • 2004
  • We have been developing a solar observing system based on a fast CCD camera 1M30P made by the DALSA company. Here we examine and present the characteristics and performance of the camera. For this we have analyzed a number of images of a flat wall illuminated by a constant light source. As a result we found that in the default operating mode 1) the mean bias level is 49 ADU/pix, 2) the mean dark current is about 8 ADU /s/pix, 3) the readout noise is 1.3 ADU, and 4) the gain is about 42 electrons/ ADU. The CCD detector is found to have a linearity with a deviation smaller than $6\%$, and a uniform sensitivity better than $1\%$. These parameters will be used as basic inputs in the analysis of data to be taken by the camera.

Stereo Calibration Using Support Vector Machine

  • Kim, Se-Hoon;Kim, Sung-Jin;Won, Sang-Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.250-255
    • /
    • 2003
  • The position of a 3-dimensional(3D) point can be measured by using calibrated stereo camera. To obtain more accurate measurement ,more accurate camera calibration is required. There are many existing methods to calibrate camera. The simple linear methods are usually not accurate due to nonlinear lens distortion. The nonlinear methods are accurate more than linear method, but it increase computational cost and good initial guess is needed. The multi step methods need to know some camera parameters of used camera. Recent years, these explicit model based camera calibration work with the development of more precise camera models involving correction of lens distortion. But these explicit model based camera calibration have disadvantages. So implicit camera calibration methods have been derived. One of the popular implicit camera calibration method is to use neural network. In this paper, we propose implicit stereo camera calibration method for 3D reconstruction using support vector machine. SVM can learn the relationship between 3D coordinate and image coordinate, and it shows the robust property with the presence of noise and lens distortion, results of simulation are shown in section 4.

  • PDF