• 제목/요약/키워드: 3phase-4leg Inverter

검색결과 15건 처리시간 0.03초

2상 유도전동기 구동을 위한 2상 인버터 토폴로지의 비교 분석 (The Comparative Analysis of 2-Phase Inverter Topologies for 2-Phase Induction Motor)

  • 김동기;윤덕용
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.1013-1018
    • /
    • 2016
  • In this paper, three kinds of the inverter topologies for the variable speed drive of 2-phase induction motor are compared and analyzed. The 2-phase inverters are classified into 2-leg, 3-leg, and 4-leg types depending on the number of power switching devices. And they use the output voltage vectors of the different forms according to the inverter topologies. Based on the comparative analyzed results, the effective values of output voltage have been defined by the linear modulation range. Therefore, the motor design guideline is proposed in order to decide a rated voltage of 2-phase induction motor according to the inverter topologies. Also, the computer simulations are carried out to verify the output voltage and current characteristics of each inverter topology.

2상 유도전동기 구동 2상 인버터를 위한 새로운 PWM제어방식 II - 3-레그 타입의 경우 - (A Novel PWM Method for Three-Leg Two-Phase Inverter Fed Two-Phase Induction Motor)

  • 장도현
    • 전력전자학회논문지
    • /
    • 제10권4호
    • /
    • pp.339-346
    • /
    • 2005
  • 본 논문에서는 3-레그 2상 인버터의 새로운 PWM방식을 제안하였다. 기존의 3-레그 인버터의 PWM방식은 전형적인 SVPWM 방식을 적용하여 PWM 방식이 복잡하다. 3-레그 2상 인버터를 "중성점이 있는 4-레그 인버터"의 등가회로라고 할 때 3-레그 인버터에서 형성되는 6개의 섹터는 4개의 섹터로 축소되며, 각 영역에서는 SYPWM 방식 대신 단순화된 정현파형 PWM방식을 적용할 수 있다. 각 레그의 스위치마다 스위칭 시간을 계산하는 스위칭 패턴을 제시하였다. 제안된 ,3-레그 인버터의 PWM방식에 대한 타당성을 확인하기 위해 모의 실험과 실험이 실행되었다.

3상 4레그 전압형 인버터를 위한 3차원 공간벡터변조 기법 (3-Dimensional SVM Technique for the Three-Phase Four-Leg Voltage Source Inverter System)

  • 도안반투안;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.111-112
    • /
    • 2013
  • The three-phase four-leg voltage source inverter (VSI) topology can be an interesting option for the three phase-four wire system. With an additional leg, this topology can handle the neutral current, hence the DC link capacitance can be reduced significantly. In this paper the three dimensional space vector modulation (3D SVM) in ${\alpha}{\beta}{\gamma}$ coordinates for the three-phase four-leg VSI is presented. By using the 3D SVM method, the DC link voltage can be reduced by 16% compared with the split DC link capacitor topology and the output distortion can also be reduced under the unbalanced load condition.

  • PDF

PR 제어기를 이용한 3상 4선식 인버터 Neutral Leg 제어 방법 (Control of the Neutral Leg in Three-Phase Four-Wire Inverter Using Proportional-Resonant Controller)

  • 한정호;송중호
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.54-61
    • /
    • 2015
  • In 3-phase 4-wire inverter, the unbalanced loads cause to increase the neutral current which brings the voltage deviation between the split dc-link capacitors to be larger. In order to solve this problem, a neutral leg is provided additively to the ordinary inverter circuit and the associated control methods are devised. This paper proposes a new neutral-leg controller based on a PR controller and shows relatively good performance even under unbalanced linear loads and nonlinear loads. The proposed control strategy illustrates its effectiveness under the various operating conditions through simulation works.

불평형 부하에서 강인한 3상4족 전압형 인버터를 위한 하이브리드 제어기의 설계 (Design of the Robust Hybrid Controller for Three-Phase Four-Leg Voltage Source Inverter under the Unbalance Load)

  • 도안반투안;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.291-292
    • /
    • 2014
  • The three-phase four-leg voltage source inverter (VSI) topology can be an interesting option for the three phase-four wire system. With an additional leg, this topology can achieve superior performance with unbalanced and/or nonlinear load. This paper proposes a new hybrid controller which combines PI controller and resonant controller in synchronous frame for three phase four leg inverter. The hybrid controller is simple in structure and easy to implement. The performance of proposed controller is verified by the experiments and compared with that of the conventional PI controller.

  • PDF

4-레그 PWM 컨버터/인버터와 AC 리액터를 사용한 새로운 3상 라인 인터렉터브 무정전전원장치의 개발 (Development of Novel 3-Phase Line-interactive UPS System using 4-leg PWM Converter/Inverter and AC Reactor)

  • 지준근;김효성;설승기;김경환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper a novel line interactive UPS (Uninterruptible Power Supply) using the two 4-leg VSCs and AC line reactor is proposed. The 4-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. One VSC is in parallel with the AC line reactor of the power source side, and the other is in series with the load. The parallel 4-leg voltage source inverter controls three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series 4-leg voltage source inverter compensates the line voltage and allows the load voltage to be balanced and harmonic-free. Both of parallel and series 4-leg voltage source inverters always act as independently controllable voltage sources, so that three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulation results.

  • PDF

유도전동기 구동을 위한 저가형 단상-3상 AC/DC/AC PWM 컨버터 (Low-Cost Single-Phase to Three-Phase AC/DC/AC PWM Converters for Induction Motor Drives)

  • 김태윤;이지명;석줄기;이동춘
    • 전력전자학회논문지
    • /
    • 제7권4호
    • /
    • pp.322-331
    • /
    • 2002
  • 본 논문은 단상 반파 PWM 정류기와 3상 2-leg 인버터를 결합한 단상-삼상 컨버터 회로에서 전원전압의 센서를 제거하여 3상 유도전동기를 저가형으로 구동하는 방법을 제안하고자 한다. 전원전압의 센서를 제거하기 위해 전원 전류의 실측치와 제어기 내의 모델전류가 일치하도록 관측기를 구성하여 전원전압을 추정한다. 본 논문에서 제안한 기법을 사용할 경우 스위칭 소자와 센서 수를 줄이면서 직류전압 일정제어, 입력전류의 정현제어 및 단위 역률 제어가 가능하고 VVVF 교류전압을 얻을 수 있다는 장점이 있다. 3[Hp]의 3상 유도전동기의 V/f 구동에 적용한 실험결과로 제시된 알고리즘의 타당성을 검증한다.

3상 4레그 전압원 인버터(Three-Phase Four-Legged Voltage Source Inverter)의 공간벡터 전압변조 방식에 대한 연구 (A Study about Space Vector PWM strategy For Three-Phase Four-Legged Voltage Source Inverter)

  • 김장환;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.154-156
    • /
    • 2003
  • 3상 4레그(leg) VSI(Voltage Source Inverter)는 독립된 3개의 출력전압을 합성할 수 있다. 따라서 전압 합성에 있어서 3개의 자유도를 갖는다. 본 논문에서는 3상 4레그 VSI를 위한 PWM방법에 대해서 설명한다. 3상 4레그 VSI를 위한 기존의 PWM기술은 3-D SVPWM으로 그 구현 방법에 있어서 많은 양의 계산과 테이블을 필요로 하였다. 하지만, 본 논문에서 제안 한 방법은 3상 3레그 VSI경우에 적용되었던 옵셋(offset) 전압의 개념을 사용한다. 또한 단일 반송파를 이용하여 폴(Pole)전압과 비교함으로써 PWM을 구현하기 때문에 그 적응이 매우 간단하다. 본 논문에서는 기존의 3-D SVPWM과 제안한 방법이 해석적으로 동일한 방법임을 증명하였으며, 3상 4레그 VSI에서 합성가능한 3자유도의 전압범위를 계산하였다. 마지막으로 이를 실험을 통하여 검증하였다.

  • PDF

마이크로그리드용 4-Leg 방식 PCS의 각상 개별제어 알고리즘에 관한 연구 (Single-phase Control Algorithm of 4-Leg type PCS for Micro-grid System)

  • 김승호;최성식;김승종;노대석
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.817-825
    • /
    • 2017
  • AC 방식 마이크로그리드는 다양한 DC/AC 인버터를 AC 네트워크에 연결하여, DC 방식 마이크로그리드의 약점을 극복 하고 있다. 그러나 소규모 마이크로그리드에서 일반적으로 발생하는 심각한 부하 불평형 현상에 의하여, AC 마이크로그리드 시스템의 성능을 약화시킬 수 있다. 이것은 마이크로그리드 내의 불평형 부하로 인하여 상별 에너지 흐름과 전압조정기능이 제한되기 때문이다. 이러한 불평형 전압문제를 해결하기 위하여, 3상 4-Leg 방식의 인버터가 제안되고 있지만, 이를 안정적으로 운용할 수 있는 제어알고리즘이 미비한 실정이다. 따라서, 본 논문에서는 부하 불평형에 의해서 발생하는 인버터의 전압 불평형 문제를 해결하고 안정적으로 제어하기 위하여 d-q제어를 기반으로 3상4선식 인버터의 각상 개별제어 알고리즘을 제안하였다. 또한, 이 알고리즘을 바탕으로 Matlab/Simulink를 이용하여 4-Leg 방식의 전압제어기 모델링을 수행하였다. 이 모델링과 250KW급 시험장치를 바탕으로 인버터의 출력전압 제어특성을 분석한 결과, 정상상태에서는 기존의 방식과 비슷한 특성을 보이지만, 과도상태에서는 제안한 각상 개별제어 방식이 기존의 방식보다 안정적으로 동작하여 제안한 방식의 유용성을 확인할 수 있었다.

파라미터 변동을 고려한 3상 4선식 인버터 Neutral Leg의 상태궤환제어 (State Feedback Control of the Neutral Leg in Three-Phase Four-Wire Inverter Considering Parameter Variations)

  • 한정호;김흥규;이영일;송중호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.514-515
    • /
    • 2014
  • 3상 4선식 인버터에서 불평형 부하는 중성선 전류를 증가시키고, 이는 직류링크 전압 불 평형을 야기한다. 이러한 이유로, neutral leg을 추가하여 불평형 부하에서 중성선전류와 직류링크전압 불평형을 제어방법이 제안되었다. 본 논문은 상태궤환제어를 이용하여 중성선전류와 직류링크전압 불평형을 제어하는 neutral leg 제어기설계 방법을 제안한다. 제안한설계 방법은 neutral leg의 파라미터 변동에도 우수한 특성을 가진다. 시뮬레이션을 통하여 본 논문이 제안한 제어방법의 타당성과 실효성을 증명한다.

  • PDF