• Title/Summary/Keyword: 3d a simulator

Search Result 595, Processing Time 0.024 seconds

Fish-trait Simulator for Constructing Virtual Aquarium System (가상수족관 시스템 구축을 위한 어류 생태 시뮬레이터)

  • Jeong, Seung-Moon;Lee, Hyeon-Cheol;Kim, Eun-Seok;Hur, Gi-Taek;Gang, Gyeong-Heon
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.3
    • /
    • pp.68-78
    • /
    • 2007
  • In a virtual aquarium, the behavior of fish objects is the most important factor in respect of visual effects. In addition to the individual behavior of fish object, the interactions between objects due to their attributes, can improve the dynamics and reality of the virtual world. In this paper, we analyze the principal habits of fish objects such as the vitality, the range of movement, the maximum depth of water they can live, and the cycle of eating. Then, we suggest a method for simulating the stable marine ecosystem with controlling the behaviors, the interaction with other species, the average span of life, and all that sort of thing based on the result of analysis. Because we can freely modify the behavior of fish object by altering the values of attributes, it can be utilized in the dynamic virtual aquarium, the 3D aquarium screen saver, and the virtual fish game, and so on.

Measurement of inconvenience, human errors, and mental workload of simulated nuclear power plant control operations

  • Oh, I.S.;Sim, B.S.;Lee, H.C.;Lee, D.H.
    • Proceedings of the ESK Conference
    • /
    • 1996.10a
    • /
    • pp.47-55
    • /
    • 1996
  • This study developed a comprehensive and easily applicable nuclear reactor control system evaluation method using reactor operators behavioral and mental workload database. A proposed control panel design cycle consists of the 5 steps: (1) finding out inconvenient, erroneous, and mentally stressful factors for the proposed design through evaluative experiments, (2) drafting improved design alternatives considering detective factors found out in the step (1), (3) comparative experiements for the design alternatives, (4) selecting a best design alternative, (5) returning to the step (1) and repeating the design cycle. Reactor operators behavioral and mental workload database collected from evaluative experiments in the step (1) and comparative experiments in the step (3) of the design cycle have a key roll in finding out defective factors and yielding the criteria for selection of the proposed reactor control systems. The behavioral database was designed to include the major informations about reactor operators' control behaviors: beginning time of operations, involved displays, classification of observational behaviors, dehaviors, decisions, involved control devices, classification of control behaviors, communications, emotional status, opinions for man-machine interface, and system event log. The database for mental workload scored from various physiological variables-EEG, EOG, ECG, and respir- ation pattern-was developed to indicate the most stressful situation during reactor control operations and to give hints for defective design factors. An experimental test for the evaluation method applied to the Compact Nuclear Simulator (CNS) installed in Korea Atomic Energy Research Institute (KAERI) suggested that some defective design factors of analog indicators should be improved and that automatization of power control to a target level would give relaxation to the subject operators in stressful situation.

  • PDF

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

An Ergonomic Shape Design for Automotive Push-Return Switches

  • Choi, Daewon;Ban, Kimin;Choe, Jaeho;Jung, Eui S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.1
    • /
    • pp.9-21
    • /
    • 2017
  • Objective: The objective of this study is to understand the effect of angle and curvature of push-return switches, which are external factors in the operation environment inside the cars, on the feel of operation and to propose optimum alternatives. Background: Customers' needs for products are changing from functional and performance aspects to customer-led type where customers can reflect on their needs on the products. The operation inside cars is executed by HMI. The push-return switch is utilized as the most intuitive mode of HMI; therefore, this push-return switch, which is widely used, has to be developed by assessing the preference and satisfaction of the customer. Method: The angle and curvatures, which are external factors that affect the feel of operation, are drawn through surveying the preceding research literatures. The stages to construct alternatives in experiments are as follows: (1) the tactile switch is replaced after dismantling the switch assembly to evaluate the internal characteristics proposed by preceding researches, (2) a drawing is prepared by using a design software, is printed using 3D printer, and then it is attached on the switch assembly, and (3) evaluation for satisfaction of operation is carried out by using a driving simulator. Results: Both the angle and curvature that are external factors of switch significantly affect the feel of operation. However, interaction between the two factors is found insignificant. Therefore, an optimum alternative is proposed considering the experimental outcomes. Conclusion: This study evaluates the satisfaction in operation that affects the feel of operation environment inside the cars. Based on the study results, a guideline for switch design in the center fascia is proposed. Application: This study is expected to be used as basic data for designing automotive switches, as well as switches in the industries similar with the operation environments of cars.

A study on the compression test using virtual reality (가상현실을 이용한 압축 실험에 관한 연구)

  • Lee Ho-Yong;Lim Joong-Yeon;Jung Ji-Youn
    • Journal of Engineering Education Research
    • /
    • v.2 no.1
    • /
    • pp.51-58
    • /
    • 1999
  • This paper is concerned with the compression test such as compression and ring compression tests, by using virtual reality. Engineering material laboratory can be carried out on personal computer without the real expensive experiment devices. The virtual laboratory is composed of three modules as input, calculation and output module on internet. Internet user can give the material's property and other parameters to the server computer at the input module. On the calculation module, simulator cimputes the results by analysis program and store the data as a file. The output module is the program that internet user can confirm a virtual compression results by showing a table, graph, and 3D animation. This program is designed by Internet language such as HTML, CGI, VRML, JAVA. And analysis program uses the finite element method with fortran language. Since the study of virtual reality on internet is rapidly increasing, the virtual experiment of technique will substitute many real experiments in the future.

  • PDF

Development of Software GPS Receiver for GEO Satellites Using Weak Signal Receiver Algorithm (미약신호 수신 알고리즘을 활용한 정지궤도위성 탑재용 소프트웨어 GPS 수신기 개발)

  • Kim, Chong-Won;Kim, Ghang-Ho;Kee, Chang-Don
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.4
    • /
    • pp.312-318
    • /
    • 2014
  • The altitudes of GEO satellites are higher than those of GPS satellites. Therefore the visibility and the received power of GPS signals are totally different from those of the users near the Earth's surface. In this study, we analyzed the visibility of GPS signals received on GEO satellites. And we also developed a software GPS receiver that works on GEO satellites using CCMDB algorithm which is a weak signal receiver algorithm. GPS signals received on a GEO satellite are generated by a commercial hardware GPS simulator and used for the verification of the developed software GPS receiver. The mean 3D position and velocity error are calculated as 165.636 m and 0.5081 m/s.

A Study on the Design of Prediction Model for Safety Evaluation of Partial Discharge (부분 방전의 안전도 평가를 위한 예측 모델 설계)

  • Lee, Su-Il;Ko, Dae-Sik
    • Journal of Platform Technology
    • /
    • v.8 no.3
    • /
    • pp.10-21
    • /
    • 2020
  • Partial discharge occurs a lot in high-voltage power equipment such as switchgear, transformers, and switch gears. Partial discharge shortens the life of the insulator and causes insulation breakdown, resulting in large-scale damage such as a power outage. There are several types of partial discharge that occur inside the product and the surface. In this paper, we design a predictive model that can predict the pattern and probability of occurrence of partial discharge. In order to analyze the designed model, learning data for each type of partial discharge was collected through the UHF sensor by using a simulator that generates partial discharge. The predictive model designed in this paper was designed based on CNN during deep learning, and the model was verified through learning. To learn about the designed model, 5000 training data were created, and the form of training data was used as input data for the model by pre-processing the 3D raw data input from the UHF sensor as 2D data. As a result of the experiment, it was found that the accuracy of the model designed through learning has an accuracy of 0.9972. It was found that the accuracy of the proposed model was higher in the case of learning by making the data into a two-dimensional image and learning it in the form of a grayscale image.

  • PDF

A Correspondence Training Scenario against Bypassing Information Protection System Attacks (네트워크 정보보호시스템 우회 공격에 대한 대응훈련 시나리오)

  • Hong, Jeong Soo;Yang, Dong Min;Lee, Bong Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.5
    • /
    • pp.818-828
    • /
    • 2018
  • Nowadays, various security systems are developed and used for protecting information on the network. Although security solutions can prevent some of the security risks, they provide high performance only if used appropriately in accordance with their purposes and functionality. Security solutions commonly used in information protection systems include firewalls, IDS, and IPS. However, despite various information protection systems are introduced, there are always techniques that can threaten the security systems through bypassing them. The purpose of this paper is to develop effective training techniques for responding to the bypass attack techniques in the information security systems and to develop effective techniques that can be applied to the training. In order to implement the test bed we have used GNS3 network simulator, and deployed it on top of virtual operating system using VirtualBox. The proposed correspondence training scenario against bypassing information protection system attacks could be very effectively used to counteract the real attacks.

Numerical modelling of Fault Reactivation Experiment at Mont Terri Underground Research Laboratory in Switzerland: DECOVALEX-2019 TASK B (Step 2) (스위스 Mont Terri 지하연구시설 단층 내 유체 주입시험 모델링: 국제공동연구 DECOVALEX-2019 Task B(Step 2))

  • Park, Jung-Wook;Guglielmi, Yves;Graupner, Bastian;Rutqvist, Jonny;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.29 no.3
    • /
    • pp.197-213
    • /
    • 2019
  • We simulated the fault reactivation experiment conducted at 'Main Fault' intersecting the low permeability clay formations of Mont Terri Underground Research Laboratory in Switzerland using TOUGH-FLAC simulator. The fluid flow along a fault was modelled with solid elements and governed by Darcy's law with the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by creating interface elements between two separating rock blocks in FLAC3D. We formulate the hydro-mechanical coupling relation of hydraulic aperture to consider the elastic fracture opening and failure-induced dilation for reproducing the abrupt changes in injection flow rate and monitoring pressure at fracture opening pressure. A parametric study was conducted to examine the effects of in-situ stress condition and fault deformation and strength parameters and to find the optimal parameter set to reproduce the field observations. In the best matching simulation, the fracture opening pressure and variations of injection flow rate and monitoring pressure showed good agreement with field experiment results, which suggests the capability of the numerical model to reasonably capture the fracture opening and propagation process. The model overestimated the fault displacement in shear direction and the range of reactivated zone, which was attributed to the progressive shear failures along the fault at high injection pressure. In the field experiment results, however, fracture tensile opening seems the dominant mechanism affecting the hydraulic aperture increase.

Design of Vertical Type MEMS Probe with Branch Springs (분기된 구조를 갖는 수직형 MEMS 프로브의 설계)

  • Ha, Jung-Rae;Kim, Jong-Min;Kim, Byung-Ki;Lee, June-Sang;Bae, Hyeon-Ju;Kim, Jung-Yup;Lee, Hak-Joo;Nah, Wan-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.831-841
    • /
    • 2010
  • The conventional vertical probe has the thin and long signal path that makes transfer characteristic of probe worse because of the S-shaped structure. So we propose the new vertical probe structure that has branch springs in the S-shaped probe. It makes closed loop when the probe mechanically connects to the electrode on a wafer. We fabricated the proposed vertical probe and measured the transfer characteristic and mechanical properties. Compared to the conventional S-shaped vertical probe, the proposed probe has the overdrive that is 1.2 times larger and the contact force that is 2.5 times larger. And we got the improved transfer characteristic by 1.4 dB in $0{\sim}10$ GHz. Also we developed the simulation model of the probe card by using full-wave simulator and the simulation result is correlated with measurement one. As a result of this simulation model, the cantilever probe and PCB have the worst transfer characteristic in the probe card.