• Title/Summary/Keyword: 3D-scan data

검색결과 393건 처리시간 0.028초

3차원 스캐너의 레지스터링 문제 해결을 위한 광학식 마커 설계 (The Design of Optical Marker for Auto-registering of 3D scan data)

  • 손용훈;양현석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.256-259
    • /
    • 2003
  • This paper proposes OPTICAL MARKER fer registering process - one of the 3D measurement process : scan registering - merging - measurement. If the registering work is carried out manually, it can be accompanied with much time and many errors. Because the patterned marker make registering process automatic, many firms use it now. But the physical shape of existing markers is the source of the data loss caused by hiding surface, and the marker arrangement is the source of the time loss. The optical marker proposed in this paper has marker generator, organized a large number of binary coded control laser diode, separate from 3D scan object. So, it does not take much time for the marker disposition, and it is not the origin of the data loss, and the binary coded laser information make the auto-registering possible.

  • PDF

3차원 인체스캔형상을 재현한 3D 아바타 제작을 위한 가상착의 시스템의 활용성 검증 -CLO 3D 프로그램을 중심으로- (Usability verification of virtual clothing system for the production of a 3D avatar reproduced from 3D human body scan shape data - Focusing on the CLO 3D program -)

  • 홍은희
    • 한국의상디자인학회지
    • /
    • 제22권1호
    • /
    • pp.1-13
    • /
    • 2020
  • The purpose of this study is to create a 3D avatar from 3D human body shape data using the CLO 3D virtual clothing program and to verify the feasibility of avatar production using the virtual clothing system for verifying size and shape. The research method was to select one virtual representative model that is the closest to the mean size of each body item for each age group. Using the 3D human body scan shape of a 40-69 years old male was applied to the CLO 3D virtual wearing system. Using the CLO 3D Avatar conversion menu, we verified the feasibility of creating a 3D avatar that reproduces the human body scan shape. In the dimension comparison between the 3D avatar and the fictitious representative model, the dimension difference was noticeable in height, circumference, and length. However, as a result, the converted 3D avatar showed less than a 5% difference in most human dimensions. In addition, since the body shape and posture were reproduced similarly, the utilization of the avatar was verified.

마커 없는 매칭을 활용한 3 차원 인체 스캔 데이터의 기준점 추출 (Landmark Extraction for 3D Human Body Scan Data Using Markerless Matching)

  • 윤동욱;허남빈;고형석
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2009년도 학술대회
    • /
    • pp.163-167
    • /
    • 2009
  • 3 차원 인체 스캔 차원 기술의 활용도는 정확도의 개선과 가격의 저렴화로 인해 산업계에서 점점 부각되고 있다. 이런 인체 스캔 데이터의 활용도를 높이기 위해서는 인체 스캔 데이터의 기준점 추출이 필수적이다. 본 논문에서는 자동으로 인체 스캔 데이터의 기준점을 추출하는 알고리즘을 제안한다. 이를 위해 여러 인체 스캔 데이터들을 활용하여 주성분 분석을 하고 최적화를 거쳐 마커 없는 매칭을 수행한다. 최종적으로는 생성된 인체 모델의 위상 구조에서 기준점을 추출한다.

  • PDF

3차원 인체 스캔 데이터를 활용한 Hip-hugger 의류용 벨트 패턴 설계 (Belt Pattern Making for Hip-hugger garment using 3D Body Scan Data)

  • 박순지;최신애
    • 한국의류산업학회지
    • /
    • 제10권5호
    • /
    • pp.652-659
    • /
    • 2008
  • This study was designed to testify the possibility and devise the method to manipulate the 3D body scan data to produce rounded-belt pattern adaptable to hip-type variation of women in their 20's. The results of this research were as follows : Firstly, based on drop-value distribution of hip and waist girth, 151 subjects were classified into three hip-types; Type 1 (15.23%) was 'cylinder type', showing lowest drop-value, Type 2 (69.54%) was 'average type' and Type3 (15.23%) was 'hourglass type' showing highest drop-value. Secondly, using CAD program, design lines for round shape belt were set on the surface of 3D scan data of representative subject of each type. And divided 3D surfaces were flattened onto the plane by the internal tools of CAD program. The measure, 'lifting value of round belt pattern', implying the level of curve ratio of pattern was higher in back than front. This result might be linked to the fact that the hip part is more protruded than the abdomen part. And the measures also showed highest values in Type 3(hourglass type) and lowest in Type 1(cylinder type), meaning that the pattern of Type 3 showed more rounded shape than that of Type 1. This finding implied that round belt for body type having high drop-value should be shaped more curved. Thirdly, difference ratios of outline length and area between 3D curves(body surface) and 2D plane(pattern) were 4.5% and 1.3%, respectively. This result demonstrated and solidified the feasibility of designing digital garment pattern from 3D body scan data.

인체의 3차원 스캔 데이터를 이용한 밀착 바디 슈트 개발 (2D Pattern Development of Tight-fitting Bodysuit from 3D Body Scan Data for Comfortable Pressure Sensation)

  • 정연희
    • 한국생활과학회지
    • /
    • 제15권3호
    • /
    • pp.481-490
    • /
    • 2006
  • Adjusting pressure level in the construction of athletes' tight-fitting garments by reducing the elastic knit pattern is a challenging subject, which influences the performance of the wearer directly. Therefore, in this study, relationship between the reduction rates of the basic pattern obtained from 3D human scan data and resultant clothing pressure was explored to improve the fit and pressure exerted by clothing. 3D scan data were obtained using Cyberware and they were transformed into a flat pattern using software based on Runge-Kutta method. Reduction rate was examined by subjective wear test as well as objective pressure measurement. As a result, difference in the length between the original 3D body scan data and the 2D tight-fitting pattern was 0.02$\sim$0.50cm (0.05$\sim$1.06%), which was within the range of tolerable limits in making clothes. Among the five garments, the 3T-pattern was superior in terms of subjective sensation and fit. The pressure of the 3T pattern was 2$\sim$4 gf/cm2 at five locations on the body, which is almost the same or a bit higher than that of Z-pattern. In the case of tight-fitting overall garment, the reduction rate of the pattern in the wale direction is more critical to the subjective sensation than the course direction. It is recommended that the reduction grading rules of course direction should be larger than that of Ziegert for a better fit of tight-fitting garments. In the case of wale direction, however, reduction grading rule should be kept the same as suggested earlier by Ziegert (1988).

  • PDF

키넥트 거리센서를 이용한 실내 이동로봇의 위치인식 및 3 차원 다각평면 지도 작성 (Localization and 3D Polygon Map Building Method with Kinect Depth Sensor for Indoor Mobile Robots)

  • 권대현;김병국
    • 제어로봇시스템학회논문지
    • /
    • 제22권9호
    • /
    • pp.745-752
    • /
    • 2016
  • We suggest an efficient Simultaneous Localization and 3D Polygon Map Building (SLAM) method with Kinect depth sensor for mobile robots in indoor environments. In this method, Kinect depth data is separated into row planes so that scan line segments are on each row plane. After grouping all scan line segments from all row planes into line groups, a set of 3D Scan polygons are fitted from each line group. A map matching algorithm then figures out pairs of scan polygons and existing map polygons in 3D, and localization is performed to record correct pose of the mobile robot. For 3D map-building, each 3D map polygon is created or updated by merging each matched 3D scan polygon, which considers scan and map edges efficiently. The validity of the proposed 3D SLAM algorithm is revealed via experiments.

Triangle Simplification에 의한 3D 인체형상분할과 삼각조합방법에 의한 2D 패턴구성 (Method of 3D Body Surface Segmentation and 2D Pattern Development Using Triangle Simplification and Triangle Patch Arrangement)

  • 정연희;홍경희;김시조
    • 한국의류학회지
    • /
    • 제29권9_10호
    • /
    • pp.1359-1368
    • /
    • 2005
  • When we develop the tight-fit 2D pattern from the 3D scan data, segmentation of the 3D scan data into several parts is necessary to make a curved surface into a flat plane. In this study, Garland's method of triangle simplification was adopted to reduce the number of data point without distorting the original shape. The Runge-Kutta method was applied to make triangular patch from the 3D surface in a 2D plane. We also explored the detailed arrangement method of small 2D patches to make a tight-fit pattern for a male body. As results, minimum triangle numbers in the simplification process and efficient arrangement methods of many pieces were suggested for the optimal 2D pattern development. Among four arrangement methods, a block method is faster and easier when dealing with the triangle patches of male's upper body. Anchoring neighboring vertices of blocks to make 2D pattern was observed to be a reasonable arrangement method to get even distribution of stress in a 2D plane.

토공현장 스캔데이터 밀도 균일화를 위한 정합 후처리 기술 개발 (Development of Registration Post-Processing Technology to Homogenize the Density of the Scan Data of Earthwork Sites)

  • 김용건;박수열;김석
    • 대한토목학회논문집
    • /
    • 제42권5호
    • /
    • pp.689-699
    • /
    • 2022
  • 최근 다양한 산업에서 첨단기술의 적용으로 높은 생산성 향상을 이루고 있지만 건설산업의 경우 생산성 향상이 비교적 낮게 조사되어, 이를 극복하기 위한 첨단기술 연구가 빠르게 진행되고 있다. 여러 첨단기술 중 3차원 스캔 기술은 실제 대상물을 손쉽게 디지털화 할 수 있다는 점에서 건설현장의 3차원 디지털 지형 모델 생성을 위한 기술로 널리 활용되고 있다. 특히 3차원 디지털 지형 모델은 토공 중장비의 자동제어 및 가이던스 등과 같은 건설 자동화의 기초자료가 될 수 있어 지형 스캔데이터의 높은 품질이 요구되고 있다. 3차원 디지털 지형 모델의 품질은 3D 스캐너의 성능 및 취득환경뿐 아니라 지형 스캔데이터 취득 후 3차원 디지털 지형 모델 생성을 위한 전처리 과정인 노이즈제거, 정합 및 병합과정 등 또한 많은 영향을 끼치고 있어, 지형 스캔데이터 처리의 성능 증진이 필요할 것으로 보인다. 본 연구에서는 3차원 디지털 지형 모델 생성을 위한 전처리 과정 중 정합과정에서 발생하는 지형 스캔데이터의 밀도 불균일 문제를 해결하고자 한다. 이를 위해 본 연구에서 개발한 정합 후처리 기술인 '픽셀기반 점군비교 알고리즘'을 제시하였으며, 실제 토공현장에서 취득한 지형 스캔데이터를 활용해 개발한 알고리즘의 성능검증을 수행하여 지형 스캔데이터 정합 후 불균일 문제의 개선 가능성을 검증하고 밀도 별 지형 스캔데이터에 대한 알고리즘의 최적 파라미터를 제시하였다.

Application Two-Dimensional Pattern Development of Cycling Tights based on the Three-Dimensional Body Scan Data of High School Male Cyclist

  • Park, Hyunjeong;Do, Wolhee
    • 한국의류산업학회지
    • /
    • 제22권5호
    • /
    • pp.595-606
    • /
    • 2020
  • This study develops an optimal two-dimensional (2D) pattern from three-dimensional human scan data by considering the cycling posture and dermatome of high school male cyclists. By analyzing the body surface change in the cycling posture and considering the dermatome of the lower limbs, the optimal cutting line setting and the development of cycling tights for individual cyclists were presented to provide data that could be used in the clothing industry. We designed three cycling tights to solve the size unsuitability. 3D design 1 is a non-extension design based on the analysis of the 3D human body scan data, in which parts were connected diagonally from the front of the knee to the back of the knee. 3D design 2 removed both the front and back to reduce air resistance during cycling. 3D design 3 did not have a cutting line on the front panel because of the air resistance during cycling in the front area. We analyzed the garment pressure for 8 points of lower body and performed a subjective evaluation of the 3D designed tights and the current cycling tights. The 3D design 1 in this study was well received in the omphalion, thigh, and hip area, while 3D design 3 was well received in the omphalion, thigh, hip, and bottom bands. Therefore, the LoNE of 3D design 1 was applied to the front, and the hip cutting line of 3D design 3 was applied to the back.

3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 - (The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner -)

  • 박선미;남윤자
    • 한국의상디자인학회지
    • /
    • 제14권1호
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF