• 제목/요약/키워드: 3D-printed

검색결과 668건 처리시간 0.03초

스피커 응용을 위한 적층형 압전 세라믹 액츄에이터 제조 및 특성 (Characteristics and Fabrication of Multi-Layered Piezoelectric Ceramic Actuators for Speaker Application)

  • 이민선;윤지선;박운익;홍연우;백종후;조정호;박용호;정영훈
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.601-607
    • /
    • 2016
  • Piezoelectric thick films of soft $Pb(Zr,Ti)O_3$ (PZT) based commercial material (S55) were fabricated using a conventional tape casting method. Ag-Pd electrodes were printed on the piezoelectric film at room temperature and all 5 layered films with a dimension of $12mm{\times}16mm$ were successfully laminated for a multi-layered piezoelectric ceramic actuator. The laminated specimens were co-fired at $1,100^{\circ}C$ for 1 h. A flat layered and dense microstructure was obtained for the $112{\mu}m$ thick piezoelectric actuator after sintering process. Thereafter, a prototype piezoelectric speaker was fabricated using the multi-layered piezoelectric ceramic actuator which can operate as a bimorph. Its SPL (sound pressure level) characteristic was also evaluated for speaker application. Frequency response revealed that the output SPL with a root mean square voltage of 10 V increased gradually to the highest peak of 87.5 dB for 1.5 kHz and exhibited a relatively stable behavior over the measured frequency range (${\leq}20kHz$) at a distance of 10 cm, implying that the fabricated piezoelectric speaker is potential for speaker applications.

Biomimetic Copper Complex Containing Polymer Modified Electrode for Electrocatalytic Reduction of Oxygen

  • Saravanakumar, D.;Nagarale, Rajaram Krishna;Jirimali, Harish Chandra;Lee, Jong Myung;Song, Jieun;Lee, Junghyun;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • 제7권4호
    • /
    • pp.298-305
    • /
    • 2016
  • The development of non-precious metal based electrocatalysts is highly desired for the oxygen reduction reaction (ORR) as alternates to noble metal based ORR electrocatalysts. Herein, we report mononulcear copper(II) complex $[CuLbpy]ClO_4$ (L=4-[(2-hydroxyphenylimino)methyl]benzoic acid) containing poly(allylamine.HCl) polymer (PAlACuLbpy) as an electrocatalyst for oxygen reduction reaction (ORR). PAlACuLbpy was mixed with poly(acrylic acid) and tetraethylortho silicate to prepare a composite and then deposited on the screen printed electrode surface. The modified electrode (PAlACuLbpy/PCE) is highly stable and showed a quasi-reversible redox behavior with $E_{1/2}=-0.2V$ vs. Ag/AgCl(3 M KCl) in 0.1 M phosphate buffer at pH 7 under argon atmosphere. PAlACuLbpy/PCE exhibited a remarkable ORR activity with an onset potential of -0.1 V vs Ag/AgCl in 0.1 M PB (pH 7) in the presence of oxygen. The kinetics for ORR was studied by rotating disk voltammetry in neutral aqueous medium and the results indicated that the number of electrons involving in the ORR is four and the conversion products are water and hydrogen peroxide.

고정밀 회전 및 축방향 이송을 위한 신개념 원통형 자기부상 스테이지 (Novel Cylindrical Magnetic Levitation Stage for Rotation as well as Translation along Axles with High Precisions)

  • 전정우;;이창린;정연호;김종문;오현석;김성신
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1828-1835
    • /
    • 2012
  • In this paper, a conceptual design and a detailed design of novel cylindrical magnetic levitation stage is introduced. This is came from planar-typed magnetic levitation stage. The proposed stage is composed of cylinder-typed permanent magnet array and semi-cylinder-typed 3 phase winding module. When a proper current is induced at winding module, a magnetic levitation force between the permanent magnet array and winding module is generated. The proposed stage can precisely move the cylinder to rotations and translations as well as levitations with the magnetic levitation force. This advantage is useful to make a nano patterning on the surface of cylindrical specimen by using electron beam lithography under vacuum. Two methods are used to calculate required magnetic levitation forces. The one is 2D FEM analysis, the other is mathematical modeling. This paper shown that results of two methods are similar. An assistant plate is introduced to reduce required currents of winding module for levitations in vacuum. The mathematical model of cylindrical magnetic levitation stage is used for dynamic simulation of magnetic levitations. A lead-lag compensator is used for control of the model. Simulation results shown that the detail designed model of the cylindrical magnetic levitation stage with the assistant plate can be controlled very well.

Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method

  • Lee, Suji;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kwon, Kung-Rock;Noh, Kwantae
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.55-64
    • /
    • 2019
  • PURPOSE. The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS. The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at ${\alpha}=.05$. RESULTS. No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P<.05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P<.05). CONCLUSION. The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.

Developing Experiential Exhibitions Based on Conservation Science Content of Bronze Mirror

  • Jo, Young Hoon;Kim, Jikio;Yun, Yong Hyun;Cho, Nam Chul;Lee, Chan Hee
    • 보존과학회지
    • /
    • 제37권4호
    • /
    • pp.362-369
    • /
    • 2021
  • In museums, exhibition content focuses mostly on cultural heritage's historical values and functions, but doing so tends to limit visitors' interest and immersion. To counter this limitation, the study developed an experiential media art exhibition fusing bronze mirrors' traditional production technology and modern conservation science. First, for the exhibition system, scientific cultural heritage contents were projected on the three-dimensional (3D) printed bronze mirror through interactions between motion recognition digital information display (DID) and the projector. Then, a scenario of 17 missions in four stages (production process, corrosion mechanism, scientific analysis and diagnosis, and conservation treatment and restoration) was prepared according to the temporal spectrum. Additionally, various media art effects and interaction technologies were developed, so visitors could understand and become immersed in bronze mirrors' scientific content. A user test was evaluated through the living lab, reflecting generally high levels of satisfaction (90.2 points). Qualitative evaluation was generally positive, with comments such as "easy to understand and useful as the esoteric science exhibition was combined with media art" (16.7%), "wonderful and interesting" (11.7%), and "firsthand experience was good" (9.2%). By combining an esoteric science exhibition centered on principles and theories with visual media art and by developing an immersive directing method to provide high-level exhibition technology, the exhibition induced visitors' active participation. This exhibition's content can become an important platform for expanding universal museum exhibitions on archaeology, history, and art into conservation science.

자연의 주름 특성을 활용한 남성 재킷 디자인 (Development of men's jacket design applying nature's folding characteristics)

  • 김희정;이윤미;이연희
    • 복식문화연구
    • /
    • 제28권6호
    • /
    • pp.787-800
    • /
    • 2020
  • This study aims to derive the criteria of folding techniques and their characteristics through analysis of literature and previous studies. This will be realized by performing a case study on male fashion design and folding. It will propose diverse directions and data for male fashion design, by making men's jackets using a folding technique. The concept and terms of folding were clarified through examination of existing literature and previous studies. Specifically, four pieces were created with motifs of the four seasons. Among the types of pleats expressed in the works, composition pleats include double ruffles, gathers, and draperies, while processed ones include box pleats, knife pleats, and accordion pleats. This study expresses continuity, fluidity, scalability, and ambiguity through the use of such pleats. The results of the production are as follows. First, in terms of the continuous use of regular and repetitive pleats, a possibility of rich pleats was confirmed because they varied depending on the gap between the pleat and target material. Second, in liquid but irregular pleats, diverse moods were created by the pleat movement. The overlapping of repeated pleats expresses diverse spaces and shapes in a 3D extended silhouette. Third, in pleat classification, ambiguity was confirmed with the use of continuous accordion pleats in the printed gradation fabric. It is anticipated that more diverse and creative designs could be created using more extended techniques in future studies.

고체 전해질 층의 어닐링 온도가 고분자 멤리스터의 전기적 특성에 미치는 영향 (Effect of annealing temperature of solid electrolyte layer on the electrical characteristics of polymer memristor)

  • 김우석;노은경;권진혁;김민회
    • 전기전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.705-709
    • /
    • 2022
  • Poly(vinylidene fluoride-trifluoroethylene)(P(VDF-TrFE)) 고체 전해질 층의 어닐링 온도가 고분자 멤리스터의 전기적 특성에 미치는 영향을 분석하였다. 형태적 분석에서 100℃ 어닐링 온도를 갖는 P(VDF-TrFE) (100P(VDF-TrFE)) 박막 대비 200℃ 어닐링 온도를 갖는 P(VDF-TrFE) (200P(VDF-TrFE)) 박막의 표면 거칠기가 약 5배 크고 두께는 약 20% 작은 것으로 나타났다. 100P(VDF-TrFE)를 갖는 멤리스터 (M100) 대비 200P(VDF-TrFE) 멤리스터 (M200)의 set voltage는 약 50% 감소하였고, reset voltage의 크기는 약 30% 증가하였다. 또한, M200이 M100보다 더 나은 메모리 유지 특성을 갖는 것으로 나타났다. 이러한 차이는 M100 대비 M200 내부의 강한 국소 전기장 때문인 것으로 판단된다. 본 연구는 고분자 멤리스터의 어닐링 온도의 중요성을 제시함에 의의가 있다.

Bactericidal Effect of a 275-nm UV-C LED Sterilizer for Escalator Handrails: Optimization of Optical Structure and Evaluation of Sterilization of Six Bacterial Strains

  • Kim, Jong-Oh;Jeong, Geum-Jae;Son, Eun-Ik;Jo, Du-Min;Kim, Myung-Sub;Chun, Dong-Hae;Kim, Young-Mog;Ryu, Uh-Chan
    • Current Optics and Photonics
    • /
    • 제6권2호
    • /
    • pp.202-211
    • /
    • 2022
  • In the pasteurization of escalator handrails using ultraviolet (UV) sterilizers, a combination of light distribution and escalator speed has priority over other important factors. Furthermore, since part of the escalator handrail has a curved structure, proper design is needed to improve the sterilization rate on the surfaces touched by users. In this paper, two types of sterilizers satisfying these conditions are manufactured with 275-nm UV-C LEDs, after modeling the three-dimensional (3D) structure of an escalator handrail and simulating optical distributions of UV-C irradiation on the handrail's surface according to light-emitting diode (LED) positions and reflector variations in the sterilizers. Pasteurization experiments with the UV-C LED sterilizers are conducted on six types of gram-positive and gram-negative bacteria, with exposure times of 0.2, 5, and 15 s at an actual installation distance of 20 mm. The sterilization rates for the gram-positive bacteria are 10.63% to 27.94% at 0.2 s, 89.44% to 96.30% at 5 s, and 99.64% to 99.88% at 15 s. Those for the gram-negative bacteria are 57.70% to 77.63% at 0.2 s, 98.90% to 99.49% at 5 s, and 99.88% to 99.99% at 15 s. The power consumption of the UV-C LED sterilizer is about 8 W, which can be supplied by a self-generation module instead of an external power supply.

폴리실라잔 고체 전해질 층과 은 활성 전극의 공정이 멤리스터의 전기적 특성에 미치는 영향 (Effect of the Processes of Polysilazane Solid Electrolyte Layer and Silver Active Electrode on the Electrical Characteristics of Memristor)

  • 양희수;오경석;김동수;권진혁;김민회
    • 전기전자학회논문지
    • /
    • 제27권1호
    • /
    • pp.25-29
    • /
    • 2023
  • 폴리실라잔 고체 전해질 층과 은(Ag) 활성 전극의 공정이 멤리스터의 전기적 특성에 미치는 영향을 살펴보았다. 더 높은 온도에서 어닐링된 고체 전해질을 갖는 멤리스터가 더 낮은 온도에서 어닐링된 고체 전해질을 갖는 소자보다 더 높은 set voltage 및 더 나은 메모리 유지 특성을 보였다. 어닐링 온도 증가에 따른 set voltage의 증가 및 메모리 유지 특성의 향상은 각각 고체 전해질 층 내부의 빈 공간의 감소 및 균일도 증가 때문인 것으로 사료된다. 고체 전해질 층을 비교적 높은 온도에서 어닐링 할지라도, 폴리실라잔 용액의 농도가 지나치게 높은 경우에는 멤리스터의 저저항상태가 유지되지 못했다. 마지막으로, 용액공정으로 형성한 Ag 활성 전극을 갖는 멤리스터는 진공공정으로 형성한 Ag 활성 전극을 갖는 소자와 달리 WORM 특성을 갖는 것으로 나타났다. 이러한 WROM 특성은 용액공정 Ag 활성 전극에 존재하는 형태적 결함 때문인 것으로 사료된다.

한국형 테스트 패널과 Static Headform Chamber 개발연구 (A Study on the Korean Fit Test Panel and Static Headform Chamber)

  • 서혜경;장호영;안하림
    • 한국산업보건학회지
    • /
    • 제33권2호
    • /
    • pp.145-155
    • /
    • 2023
  • Objectives: A fit test panel is needed to identify the fit performance of a respirator and its face seal. This is a criterion for selecting subjects that can represent the facial characteristics of users. Although anthropometry data has been developed for people in United States and China it is not yet present in Korea. This study aimed to develop a Korean fit test panel and test headform. Methods: For the 7th and 8th waves of the Size Korea anthropometry data, facial measurements of 11,429 people aged 15 to 69 years were used for analysis. PCA and bivariate panel were classified using the ISO16976-2:2022(E) anthropometrics analysis method. Based on this result, a static headform was developemed and a fit test chamber was constructed. Results: Of the 11,429 Korean people used for principal component analysis, 11,300 were included in the ellipse, marking an acceptance rate of 98.87% on PCA panel. The face types were classified into five types. Among them, a large, medium, and small static headform were printed using a 3D printer. In addition, 10,985 people (96.12%) were included in the bivariate panel based on face length and face width. The y-axis (face length) boundary was 97.87 to 134.59 mm, and the x-axis (face width) boundary was 120.75 to 158.23 mm. Conclusions: Compared to the ISO analysis, the Korean principal component was narrower in the width item (PC1) and longer in the length item (PC2). For the future, it is necessary to conduct a fit test using the developed headform and chamber device to confirm the usefulness of this Korean test panel. Therefore, this study is considered valuable as basic research for Korean test panels.