• Title/Summary/Keyword: 3D ultrasonography

Search Result 69, Processing Time 0.034 seconds

Effect of Lipopolysaccharides Treatment on Uterine Involution in Dairy Cows with Retained Placenta (후산정체 젖소에 있어서 Lipopolysaccharide의 처리가 자궁 회복에 미치는 영향)

  • Baek, K.S.;Park, S.J.;Park, S.B.;Lee, W.S.;Kim, H.S.;Jeong, G.Y.;Ki, K.S.;Suh, G.H.;Jeon, B.S.;Ahn, B.S.;Kim, T.I.
    • Journal of Embryo Transfer
    • /
    • v.21 no.3
    • /
    • pp.233-239
    • /
    • 2006
  • This study was carried out to investigate the effect of intra-uterine infusion of lipopolysaccharides (LPS) on uterine involution in dairy cows with retained placenta. The LPS isolated from Bacteroides helcogenes and Fusobaoterium varium was infused at the rate of 100 ug (n=11) and 200 ug (n=11) with 30 ml of phosphate buffer saline in each cow at 20 days post-partum. The cows in conrol group (n=11) with retained placenta were infused with 30 ml phosphate buffer saline in each cow at 20 days postpartum. Cross-sectional ultrasonography was performed at days 40 postpartum to examine uterine involution and exudate in the all dairy cows in study. The cows in control group have shown 45.5, 27.3 and 27.3% gravid horn with less than 30 mm (normal), $31{\sim}50mm$ (medium) and more than 51 mm (large) in diameter. Respective average values of gravid horn diameter in cows treated with LPS 200 ug were noticed 72.7, 18.2 and 9.1%. However, the gravid horn diameter in all the cows treated with 100 ug of LPS was less than 30 mm. The 18.2, 63.6 and 54.6% cows in the control, LPS 100 ug and LPS 200 ug, respectively, have shown no exudate in uterine cavity. However, the respective rates of small amount of exudate retention in uterine cavity were 45.5, 0.0, and 9.1%. Approximately 36.4% cows in all 3 treated groups have shown minute quantity of exudate. In conclusion, the LPS intra-uterine infusion promoted postpartum uterine involution in dairy cows with retained placenta.

Laparoscopic Operation for Superior Mesenteric Artery Syndrome and Follow-up with 3-Dimensional Reconstructive CT - 1 Case Report - (상장간막동맥 증후군의 복강경 수술 및 3차원재건 복부 전산화단층촬영 영상을 이용한 추적관찰 -1예보고-)

  • Kim, Seong-Min;Kim, Sung-Hoon;Kwon, In-Kyou;Kim, Myoung-Joon;Hyoung, Woo-Jin;Choi, Seung-Hoon
    • Advances in pediatric surgery
    • /
    • v.11 no.2
    • /
    • pp.180-185
    • /
    • 2005
  • Superior mesenteric artery (SMA) syndrome is a rare disorder caused by extrinsic compression of the third portion of the duodenum by the SMA. The operative treatment of choice is bypassing the obstructed duodenal segment by duodenojejunostomy. We report one case of SMA syndrome treated by laparoscopic duodenojejunostomy and followed up by 3D-reconstructive CT scan. A fifteen-year-old boy with intermittent vomiting and weight loss was admitted. Ultrasonography showed narrowing of the distance between the SMA and aorta. Hypotonic duodenography showed dilatation of duodenal third portion and barium stasis. On 3Dreconstructive CT scan, the angle between SMA and aorta was $37^{\circ}$. The postoperative course was uneventful. Three months later, he had gained 3 kg of weight and the angle between SMA and aorta increased to $38-39^{\circ}$ on 3D reconstructive CT scan. Laparoscopic duodenojejunostomy for bypassing the obstructive duodenum in SMA syndrome is a feasible and safe method.

  • PDF

Technical Performance of Two-Dimensional Shear Wave Elastography for Measuring Liver Stiffness: A Systematic Review and Meta-Analysis

  • Dong Wook Kim;Chong Hyun Suh;Kyung Won Kim;Junhee Pyo;Chan Park;Seung Chai Jung
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.880-893
    • /
    • 2019
  • Objective: To assess the technical performance of two-dimensional shear wave elastography (2D-SWE) for measuring liver stiffness. Materials and Methods: The Ovid-MEDLINE and EMBASE databases were searched for studies reporting the technical performance of 2D-SWE, including concerns with technical failures, unreliable measurements, interobserver reliability, and/or intraobserver reliability, published until June 30, 2018. The pooled proportion of technical failure and unreliable measurements was calculated using meta-analytic pooling via the random-effects model and inverse variance method for calculating weights. Subgroup analyses were performed to explore potential causes of heterogeneity. The pooled intraclass correlation coefficients (ICCs) for interobserver and intraobserver reliability were calculated using the Hedges-Olkin method with Fisher's Z transformation of the correlation coefficient. Results: The search yielded 34 articles. From 20 2D-SWE studies including 6196 patients, the pooled proportion of technical failure was 2.3% (95% confidence interval [CI], 1.3-3.9%). The pooled proportion of unreliable measurements from 20 studies including 6961 patients was 7.5% (95% CI, 4.7-11.7%). In the subgroup analyses, studies conducting more than three measurements showed fewer unreliable measurements than did those with three measurements or less, but no intergroup difference was found in technical failure. The pooled ICCs for interobserver reliability (from 10 studies including 517 patients) and intraobserver reliability (from 7 studies including 679 patients) were 0.87 (95% CI, 0.82-0.90) and 0.93 (95% CI, 0.89-0.95), respectively, suggesting good to excellent reliability. Conclusion: 2D-SWE shows good technical performance for assessing liver stiffness, with high technical success and reliability. Future studies should establish the quality criteria and optimal number of measurements.

Measurement of S1 foramen depth for ultrasound-guided S1 transforaminal epidural injection

  • Ye Sull Kim;SeongOk Park;Chanhong Lee;Sang-Kyi Lee;A Ram Doo;Ji-Seon Son
    • The Korean Journal of Pain
    • /
    • v.36 no.1
    • /
    • pp.98-105
    • /
    • 2023
  • Background: Ultrasound-guided first sacral transforaminal epidural steroid injection (S1 TFESI) is a useful and easily applicable alternative to fluoroscopy or computed tomography (CT) in lumbosacral radiculopathy. When a needle approach is used, poor visualization of the needle tip reduces the accuracy of the procedure, increasing its difficulty. This study aimed to improve ultrasound-guided S1 TFESI by evaluating radiological S1 posterior foramen data obtained using three-dimensional CT (3D-CT). Methods: Axial 3D-CT images of the pelvis were retrospectively analyzed. The radiological measurements obtained from the images included 1st posterior sacral foramen depth (S1D, mm), 1st posterior sacral foramen width (S1W, mm), the angle of the 1st posterior sacral foramen (S1A, °), and 1st posterior sacral foramen distance (S1ds, mm). The relationship between the demographic factors and measured values were then analyzed. Results: A total of 632 patients (287 male and 345 female) were examined. The mean S1D values for males and females were 11.9 ± 1.9 mm and 10.6 ± 1.8 mm, respectively (P < 0.001); the mean S1A 28.2 ± 4.8° and 30.1 ± 4.9°, respectively (P < 0.001); and the mean S1ds, 24.1 ± 2.9 mm and 22.9 ± 2.6 mm, respectively (P < 0.001); however, the mean S1W values were not significantly different. Height was the only significant predictor of S1D (β = 0.318, P = 0.004). Conclusions: Ultrasound-guided S1 TFESI performance and safety may be improved with adjustment of needle insertion depth congruent with the patient's height.

Evaluation of Functional Status of Ovarian Cysts in Slaughtered Korean Native Cows (도축 한우에서 난소낭종의 기능성 평가)

  • Kang H.G.;Lee C.S.;Kim I.H.;Mo I.P.;Lee K.C.;Suh G.H.
    • Journal of Embryo Transfer
    • /
    • v.21 no.1
    • /
    • pp.59-67
    • /
    • 2006
  • To evaluate the functional status of ovarian cyst in Korean native cows, progesterone ($P_4$) and estrogen ($E_2$) level of cystic follicular fluid, ultrasonography for measuring the cystic diameter and thickness of cystic wall, and histological findings were investigated in cystic ovaries from slaughtered Korean native cows. Ovarian cysts were classified as single follicular cyst 51 cows (59.3%), multiple follicular cysts 19 cows (22.1%), single luteal cyst 13 cows (15.1%) and multiple luteal cysts 3 cows (3.5 %) by anatomical and ultrasonography. Ovarian cysts were classified as follicular cysts (54 cows), luteal cyst (16 cows) and non-functional ovarian cyst (16 cows) by hormone analysis, anatomical finding and ultasonography The luteal cyst was accurately diagnosed by cystic wall thickness, but follicular cysts was misdiagnosed 16 cows of 70 cystic cows The cystic fluid $P_4$ concentration was 3.3 ng/ml in follicular cysts and 30.1 ng/ml luteal cysts. There was significantly positive correlations between cystic wall thickness and serum $P_4$ concentration in follicular ($r^2=0.59$, p<0.001) and luteal cysts ($r^2=0.65$, p<0.001). These results indicated that ovarian cysts had various stages of degeneration and luteal cyst was accurately diagnosed measurement of cystic wall thickness by ultrasonography, but follicular cysts were not diagnosed only cystic diameter and cystic wall thickness.

Clinical Utility of Chest Sonography in Chronic Obstructive Pulmonary Disease Patients Focusing on Diaphragmatic Measurements

  • Hend M. Esmaeel;Kamal A. Atta;Safiya Khalaf;Doaa Gadallah
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.1
    • /
    • pp.80-90
    • /
    • 2024
  • Background: There are many methods of evaluating diaphragmatic function, including trans-diaphragmatic pressure measurements, which are considered the key rule of diagnosis. We studied the clinical usefulness of chest ultrasonography in evaluating stable chronic obstructive pulmonary disease (COPD) patients and those in exacerbation, focusing on diaphragmatic measurements and their correlation with spirometry and other clinical parameters. Methods: In a prospective case-control study, we enrolled 100 COPD patients divided into 40 stable COPD patients and 60 patients with exacerbation. The analysis included 20 age-matched controls. In addition to the clinical assessment of the study population, radiological evaluation included chest radiographs and chest computed tomography. Transthoracic ultrasonography (TUS) was performed for all included subjects. Results: Multiple A lines (more than 3) were more frequent in COPD exacerbation than in stable patients, as was the case for B-lines. TUS significantly showed high specificity, negative predictive value, positive predictive value, and accuracy in detecting pleural effusion, consolidation, pneumothorax, and lung mass. Diaphragmatic measurements were significantly lower among stable COPD subjects than healthy controls. Diaphragmatic thickness and excursion displayed a significant negative correlation with body mass index and the dyspnea scale, and a positive correlation with spirometry measures. Patients in Global Initiative for Chronic Obstructive Lung Disease (GOLD) group D showed lower diaphragmatic measurements (thickness and excursion). Conclusion: The TUS of COPD patients both in stable and exacerbated conditions and the assessment of diaphragm excursion and thickness by TUS in COPD patients and their correlations to disease-related factors proved informative and paved the way for the better management of COPD patients.

The reliability of dual rehabilitative ultrasound imaging measurements for muscle co-activation

  • Hahn, Joohee;Ha, Hyun-Geun;Lee, Hwang-Jae;Lim, Seungyeop;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.3
    • /
    • pp.152-157
    • /
    • 2017
  • Objective: The aim of this study was to determine the intra-rater and inter-rater reliability of the dual rehabilitative ultrasound imaging (D-RUSI) when simultaneously measuring muscle thickness changes at rest and during co-contraction of the biceps brachii (BB) and triceps brachii (TB). Design: Cross-sectional study. Methods: This study included 36 healthy participants (23 men, 13 women). The participants sat on a chair in a comfortable position with a cushion placed under their elbow to maintain a 90-degree elbow flexion angle. The muscle thickness of the biceps brachii and triceps brachii was measured twice using the D-RUSI by two examiners during resting and co-contraction states. One week later, the same procedure was performed once again. Results: The intra-class correlation coefficients (ICCs) for intra-rater reliability ranged from 0.887 to 0.989 and the confidence interval was within an acceptable range of 0.778 to 0.994. The standard error of measurement (SEM) values ranged from 0.303 to 0.866 and the minimal detectable change (MDC) values ranged from 0.84 to 2.40. The ICCs for inter-rater reliability ranged from 0.758 to 0.925. The SEM values ranged from 0.702 to 1.486 and the MDC values ranged from 1.95 to 4.12. Conclusions: The use of the D-RUSI of the BB muscle had a very good intra-rater reliability and very good inter-rater reliability at the resting state, and a, good inter-rater reliability at the co-activation state. ICC values showed very good intra-reliability and inter-reliability for the TB muscle. the D-RUSI is a useful tool for simultaneously measuring the thickness of two muscles when the BB is an agonist and the TB is an antagonist during co-activation of the upper arm.

Synchronization Rate, Size of the Ovulatory Follicle, and Pregnancy Rate after Synchronization of Ovulation Method in Hanwoo (한우에 Ov-synch 처리시 배란시기와 수태율 구명에 관한 연구)

  • 박정준;이명식;박수봉;임석기;전기준;정영훈;우제석;나기준;고대환
    • Journal of Embryo Transfer
    • /
    • v.18 no.3
    • /
    • pp.187-193
    • /
    • 2003
  • Recently a protocol was developed that precisely synchronizes the time of ovulation in Hanwoo. Cows were treated with GnRH on Day 0, PGF$_2$$\alpha$ 7 d later, GnRH 2 d later, and then time-inseminated approximately 24 h after this second treatment with GnRH. Ovarian morphology was monitored cows by trans-rectal ultrasonography 6.5MHz linear transrectal probe(Sonovet - 600., Medison co. Korea) from 24 hr to 31 hrs after second GnRH injection. The result obtained summarized as follows - 1. Induced ovulation were 24 to 31hr after the second GnRH injection, but high induced ovulation was 28hr. 2. Conception rate with HML(High meat lin) and HIL(High milk lin) treatment were 48.1%(38/79) and 43.9%(40/91), respectively. 3. Conception rate of 1∼2 parity and 3∼4 parity was 44.3% and 55%, respectively. 4. Conception rate of spring, autumn was more increased, 47.3% than summer.

A Study on the Necessity of an Age Limitation in Screening Mammography (검진 기관에서의 선별 유방촬영술 시행에 따른 연령 제한의 필요성에 대한 연구)

  • Yun, Ha-Yan;Lee, Choon-Mi;Ahn, Ui-Kyeong;Kim, Yong-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.33-41
    • /
    • 2010
  • National Cancer Screening Project and Korean Society of Breast Imaging recommend that breast cancer screening should be performed on those aged 40 and above. Nevertheless, this recommendation is usually ignored by a number of medical institutions. The purpose of this study is to emphasize the necessity of an age limitation in screening mammography. Ten institutions were randomly selected and telephone inquiries about patients' age limitation and internal guidelines were set up. The 3,214 women, who underwent screening mammography through 'GE Senography 2000D' in each hospital, were classified into five groups according to age(from 20s to 40s, at intervals of 5). And then, collected data was analyzed by a radiologist in accordance with ACR-BIRADS(American College of Radiology Breast Imaging Reporting and Data System), through which breast parenchymal density and the results of analysis were categorized in order to predict the sensitivity of mammography. Information about craniocaudal-view mammograms was automatically produced by use of GE Senography 2000D, and the average glandular dose was retrospectively analyzed through the program 'Excel 2007.' Two institutions did not set the age limitation. Other seven institutions internally allowed those who wanted to receive mammography regardless of age. Approximately 99% of those aged 20 to 29 were judged as having the dense breast. In those aged 35 to 39, breast parenchymal density tended to be lower, but the fatty breast to increase. In the case of 'category-zero' that does not need additional tests, the rate of 'heterogeneously dense' and 'extremely dense' reached to 83.1% and 15.1% respectively. Regarding dense breasts, there was no sufficient information for image reading. The glandular dose, applied to 3,214, was 1.47mGy on the average. In those aged 20 to 24 who are sensitive to radiation, the average glandular dose indicated 1.59mGy. Those aged 35 and above showed the lowest value, 1.43mGy. In those aged 35 to 39, the breast tended to change from denseness to fattiness. The average glandular dose was lowest in those aged 35 and above, which suggests that screening mammography should be periodically performed on those aged 35 and above in order that breast cancer may be early detected. On the other hand, in those aged less than 35, it is difficult to analyze mammograms due to the high density of breast parenchyma, and also retakes become frequent. In particular, subjects may be exposed to excessive doses. Accordingly, it should be substituted by breast self-examination or clinical breast examination. In case of need, it is advisable to perform ultrasonography.

  • PDF

Feasibility for Ultrasound Pad Material for the Evaluation Axillary Region of Automated Breast Ultrasound Equipment (자동유방초음파 장비의 액와부 평가를 위한 초음파 패드 물질의 타당성)

  • Seo, Eun-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.231-240
    • /
    • 2018
  • Automated breast ultrasound (ABUS) equipment is a new innovative technique for 3D automatic breast scanning, but limited for the examination in the concave axillary region. The purpose of this study was to determine feasible candidate materials for the ultrasonic wave propagation media in ABUS, enabling the evaluation of the axillary region. Ultrasonography was performed using an ABUS system ($Invenia^{TM}ABUS$, GE, USA) on the ultrasound-specific phantom (UC-551M-0.5, ATS Laboratories, USA) covered by different candidate materials. The validity of feasible candidate materials was evaluated by image quality. Three independent radiological technologists, with more than 10 years of experience, visually assessed on the images. The inter-observer agreements according to the candidate materials were tested using Cronbach's alpha. Unenveloped solidified carrageenan can be a feasible material for the use of ABUS with excellent test reliability. Therefore, the coverage of the axillary region with carrageenan may be effective for ABUS which was originally developed for the convex anatomic structure as female breast.