• 제목/요약/키워드: 3D shape analysis

Search Result 1,211, Processing Time 0.026 seconds

An Anthropometric Study on the Korean Adult Head for the Development of 3D Craniofacial Shape (한국 성인의 3차원 두형개발을 위한 머리치수 연구)

  • Kim Hyesoo;Kim Jin Sook;Yi Kyong-Hwa;Park Sejin
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.6 s.208
    • /
    • pp.13-25
    • /
    • 2005
  • The purpose of this study was to analyse craniofacial shape by 3D scanner for Korean adult head shape by age group. The heads of 836 adults were measured by 3D scanner, and the 25 obtained measurements were analyzed by statifical methods. The results can be summarized as follows. 1. From the basic statistical data analysis, the vertex-tagion and the length between the pupils were the longest in the subjects in their twenties, and decreased in elderly groups. 2. According to the analysis of the craniofacial proportion, the typical adult Korea head type was short-headed. 3. Statistically noticeable differences were found in the ectocanthion- opistcranion by the measurement of the left and the right sides of face in the age groups of the 20s, 30s, 40s, and 50s. 4. The order of factor analysis was as follows: the horizontal length, the perpendicular length and the width from the highest in the age group of the 20s, 30s, 40s, and 50s.

The Analysis of 3-Dimensional Shape Using Non-Metric Cameras (비측량용 카메라를 이용한 3차원 형상 해석)

  • Jeong, Soo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.2
    • /
    • pp.91-99
    • /
    • 2009
  • In the field of geospatial information, 3D shape information has been considered as a frame data for GIS. Many kind of physical shape information is, especially, required for the works related with space, such as planning, maintenance, management, etc. Conventional photogrammetry was implemented under the conditions with expensive metric cameras and analytical plotters operated by experts. Nowadays, however, the metric cameras and analytical plotters are replaced by low price non-metric digital cameras and personal computers by virtue of the progress in digital photogrammetry. This study aims to investigate the technology to easily and promptly produce 3D shape information required in geospatial information system using close-range photogrammetry with non-metric digital cameras. As the results of this study, 3D shape of an experimental object was made out with a common compact digital camera and only a known length of a line component in the object and the accuracy of the dimension of 3D shape was analyzed to be less than one pixel.

  • PDF

Optimization of Process Variables of Shape Drawing for Steering Spline Shaft (조향장치용 스플라인 샤프트 이형인발 공정변수 최적화)

  • Lee, S.K.;Kim, S.M.;Lee, S.B.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.19 no.2
    • /
    • pp.132-137
    • /
    • 2010
  • In the multi-pass shape drawing process, the appropriate process design is very important to produce sound products. The reduction ratio, die angle, and the intermediate die shape are very important process variable of the multi-pass shape drawing. The aim of this study is the determination of the reduction ratio, die angle, and the intermediate die shape of the 2 pass shape drawing process for producing steering spline shaft. In this study, FE analysis, Taguchi method, and ANN(artificial neural network) were applied to determine the appropriate reduction ratio, die angle, and intermediate die shape. After the determination of the process variables, FE analysis and drawing experiment were performed to evaluate the effectiveness of the determined process variables. The dimensional accuracy of the final drawn spline shaft was evaluated by using 3D surface profiler and 3D laser digitizing system.

Structural Behavior Analysis of Polymer Lattice Reinforced 3D Printing Cementitious Cladding (폴리머 격자 보강재를 이용한 3D 프린팅 시멘트계 외장재의 구조 거동 분석)

  • Kim, Hak-Beom;Park, Min-Jae;Ju, Young K.
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.3-10
    • /
    • 2018
  • Cladding that finishes the exterior of a building could enhance the value of the building, and shape control is an important factor. With the recent development of 3D printing, cementitious claddings were printed by 3D printer in China, U.S.A and elsewhere. On the other hand, the structural safety of the exterior panel should be examined, as casualties occur when the exterior panel fails due to typhoon or impact. Cement-based cladding is reinforced by wire mesh to improve safety. Introducing 3D printing composite system with polymer and cement, makes it possible to produce claddings fast and accurate. Prior to the development of 3D printing cementitious cladding, the major parameters influencing the optimal shape were identified based on structural performance. The wind load, joint, and bond behavior between polymer and cement were considered. Polymer laminate shape, order, and thickness were variables, and finite element analysis was performed.

Design Sensitivity Analysis for Shape Optimization of Electromagnetic Device with Finite Element Method (설계민감도해석과 FEM에 의한 전자소자의 형상최적화)

  • Ryu, Jae-Seop;Koh, Chang-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.835-837
    • /
    • 2002
  • This paper presents a shape optimization algorithm of electromagnetic devices using the design sensitivity analysis with FEM. The design sensitivity and adjoint variable formulas are derived for the 3D FEM with edge element. This algorithm is applied to 3D electro-magnet pole shape optimization problem to make a uniform flux density at the target region.

  • PDF

An Accuracy Analysis of the 3D Automatic Body Measuring Machine (3차원 자동체형계측기 정밀도 검사)

  • Jeon, Soo-Hyung;Kwon, Suk-Dong;Park, Se-Jung;Kim, Jung-Yang;Song, Jung-Hoon;Kim, Hyun-Jin;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.20 no.1
    • /
    • pp.42-47
    • /
    • 2008
  • 1. Objectives The Body Shape and Feature is one of the important standard for classification of Sasang Constitutions. In order to evaluate one's Body Shape and Feature objectively we have been developing the Body Measuring Machine. Now we develop the 3D Automatic Body Measuring Machine(3D-ABMM). So we make an analysis of the 3D-ABMM's Accuracy. 2. Methods By using the 3D-ABMM and Vivid 9i(3D laser scanner, Konica Minolta) we have a surface scan of the three objects which are the upper body of the female and male Manikin and a male model. We overlap each scan data using the RapidForm2006 (3D scan data solution, INUS Technology) and calculate the average distance and standard deviation between the same point of each scan data. 3. Results and Conclusions In the female Manikin, the average distance is 0.84mm and the standard deviation is 1.16mm and the maximum distance is 10.68mm. In the male Manikin, the average distance is 1.12mm and the standard deviation is 1.19mm and the maximum distance is 12.00mm. In the male model, the average distance is 3.26mm and the standard deviation is 2.59mm and the maximum distance is 12.75mm. From the results, 3D-ABMM has good accuracy for scanning body and will be a usable hardware of the 3D Automatic Body Analysis Machine.

  • PDF

A Study on Body Shape for 3D Virtual Body Shape Transformation - Focusing on the Women with age of forties - (3차원 가상바디 변형을 위한 체형연구 - 40대 여성을 대상으로 -)

  • Shin, Ju-Young Annie;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.17 no.2
    • /
    • pp.265-277
    • /
    • 2015
  • The aim of this study was to successfully reflect human body changes on the transformation of the virtual body within 3D virtual fitting spaces. For this purpose, existing problems of shape transformation of the virtual body were analyzed and regression equations which provides useful basic data for transformation of the virtual body that can be applied usefully to the 3D virtual fitting system was developed. Necessary data for the analyses were body measurement and 3D scan data of women with average physical form between the ages of 40 through 49. The reason that we used human body changes of the female subjects in their forties was based on the recognition that fundamental female body changes start to occur from age of forty. Body shapes were largely divided into 3 groups according to obesity which was found to be the biggest factor of shape change. Seven factors were extracted based on factor analysis of 47 body measurement categories and regression equations were created to extract specific measurements for each BMI group based on these seven factors. The major contribution of this paper can be summarized as follows. First, the regression equations to extract specific measurements based on the 7 representative variables remediated existing problem of virtual bodies as it increased the number of body shape transformation areas. Second, the regression equations helped to overcome the problem of current failing to reflecting changes in body cross-section shape based on simple girth measurements based on analysis of cross-section distances.

Analysis of the Ease in Basic Bodice Pattern Using 3-D Measuring Instrument (3차원 계측장치를 이용한 길 원형의 여유량 분석)

  • Shim, Kue-Nam;Suh, Jung-Kwon;Lee, Won-Ja
    • Fashion & Textile Research Journal
    • /
    • v.2 no.3
    • /
    • pp.239-245
    • /
    • 2000
  • The purpose of this study was for analysis of ease about basic bodice pattern, as the first step of the research process for the drawing method of basic bodice for women in their twenties. The five selected basic bodice were made and they were worn by FRP body The garment space of each bodice was measured by analysis of the garment space of each section in figure of polymerization of cross section by a 3-D measuring instrument. The research suggests that this compared analysis is an objective reference. This analysis not only of the area of cross section of garment space and ease but also of the girth of the body shape and wearing shape, using the PAD system and 3-D measuring instrument, can be helpful in making garment patterns.

  • PDF

Analysis of Geometrical Relations of 2D Affine-Projection Images and Its 3D Shape Reconstruction (정사투영된 2차원 영상과 복원된 3차원 형상의 기하학적 관계 분석)

  • Koh, Sung-Shik;Zin, Thi Thi;Hama, Hiromitsu
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.1-7
    • /
    • 2007
  • In this paper, we analyze geometrical relations of 3D shape reconstruction from 2D images taken under anne projection. The purpose of this research is to contribute to more accurate 3-D reconstruction under noise distribution by analyzing geometrically the 2D to 3D relationship. In situation for no missing feature points (FPs) or no noise in 2D image plane, the accurate solution of 3D shape reconstruction is blown to be provided by Singular Yalue Decomposition (SVD) factorization. However, if several FPs not been observed because of object occlusion and image low resolution, and so on, there is no simple solution. Moreover, the 3D shape reconstructed from noise-distributed FPs is peturbed because of the influence of the noise. This paper focuses on analysis of geometrical properties which can interpret the missing FPs even though the noise is distributed on other FPs.

A Study on the Classification of Lower Body Shape Type for Fit Evaluation of Slacks (슬랙스 맞음새 평가를 위한 하반신 체형 유형화에 관한 연구)

  • Kim, Seonyoung;Nam, Yunja
    • Journal of Fashion Business
    • /
    • v.20 no.2
    • /
    • pp.181-196
    • /
    • 2016
  • This study intended to suggest criteria for selection of subjects by lower body shape types necessary for evaluating slacks. For this, the characteristics were examined by lower body parts which would influence the fit of slacks on 3D human body shape data of the front and sides of the lower body for lower body shaping. The frequency of subjects by lower body shape types and the boundary points for discrimination of each type were suggested so that they could be available in selecting subjects. Using the data from Size Korea(2004), indirect measurement values measured on the front and sides of the lower body among 3D human body shape data of 175 subjects were analyzed. Their height, waist, and hip circumference fell under the range of standard deviation based on the mean of women aged 18~24 years, and then lower body shaping was conducted by combining the front and side shapes of the lower body. The front of the lower body was classified into four sections: average waist/average hip type(F1), average waist/narrow hip tyle(F2), narrow waist/narrow hip type(F3) and narrow waist/wide hip type(F4) and the sides of the lower body were divided into four sections: average abdomen/average hip type(S1), flat abdomen/average hip type(S2), average abdomen/protrude hip type(S3)and round abdomen/flat hip type(S4), and thus total 16 lower body types were created by cross analysis. Besides, discriminant analysis suggested the boundary points for each shape type of the front and sides of the lower body as a criterion for deciding lower body shape type of each subject