• Title/Summary/Keyword: 3D sensor

Search Result 1,604, Processing Time 0.035 seconds

Review Study on the Measurement Tools of Scoliosis: Mainly on Non-radiological Methods (척추측만증 평가 척도에 관한 문헌 고찰: 비방사선 방법을 중심으로)

  • Kim, Dong-Joo;Choi, Seong-Kyeong;Jo, Hyo-Rim;Ha, Yu-bin;Choi, Sung-Hwan;Park, Seo-Hyun;Lee, Seung Deok;Keum, Dong-Ho;Sung, Won-Suk;Kim, Eun-Jung
    • The Journal of Korean Medicine
    • /
    • v.42 no.1
    • /
    • pp.75-98
    • /
    • 2021
  • Objectives: The purpose of this study is to investigate the characteristics, validity, and reliability of non-radiological assessment tools of scoliosis that have been studied so far. Methods: Electronic databases including Pubmed, Cochrane Library, CNKI, Science On, RISS, OASIS were searched by keywords including 'scoliosis assessment', 'scoliosis screening', 'physical examination', 'functional measurement', 'photography', and 'smartphone'. Results: 32 articles using radiation-free assessments were identified from 1,011 records. The mostly used non-radiological methods were Surface topography, Scoliometer, Ultrasound, Digital Infrared Thermal Imaging, and Photography. The other methods were Gait analysis, 3D depth sensor imaging, and Low intensity electromagnetic scan. Conclusions: It was found that non-radiological assessment tools might reduce the number of radiographs taken in scoliosis patients. To increase the reliability and validity, further research on the measurement tools of scoliosis will be needed.

Accuracy Comparison of Spatiotemporal Gait Variables Measured by the Microsoft Kinect 2 Sensor Directed Toward and Oblique to the Movement Direction (정면과 측면에 위치시킨 마이크로 소프트 키넥트 2로 측정한 보행 시공간 변인 정확성 비교)

  • Hwang, Jisun;Kim, Eun-jin;Hwang, Seonhong
    • Physical Therapy Korea
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Background: The Microsoft Kinect which is a low-cost gaming device has been studied as a promise clinical gait analysis tool having satisfactory reliability and validity. However, its accuracy is only guaranteed when it is properly positioned in front of a subject. Objects: The purpose of this study was to identify the error when the Kinect was positioned at a $45^{\circ}$ angle to the longitudinal walking plane compare with those when the Kinect was positioned in front of a subject. Methods: Sixteen healthy adults performed two testing sessions consisting of walking toward and $45^{\circ}$ obliquely the Kinect. Spatiotemporal outcome measures related to stride length, stride time, step length, step time and walking speed were examined. To assess the error between Kinect and 3D motion analysis systems, mean absolute errors (MAE) were determined and compared. Results: MAE of stride length, stride time, step time and walking speed when the Kinect set in front of subjects were investigated as .36, .04, .20 and .32 respectively. MAE of those when the Kinect placed obliquely were investigated as .67, .09, .37, and .58 respectively. There were significant differences in spatiotemporal outcomes between the two conditions. Conclusion: Based on our study experience, positioning the Kinect directly in front of the person walking towards it provides the optimal spatiotemporal data. Therefore, we concluded that the Kinect should be placed carefully and adequately in clinical settings.

A Study on the Augmented Reality Display for Educating Power Tiller Operator using Chroma-key (크로마키를 이용한 증강현실 영상출력 연구)

  • Kim, Yu Yong;Noh, Jae Seung;Hong, Sun Jung
    • Journal of agriculture & life science
    • /
    • v.51 no.1
    • /
    • pp.205-212
    • /
    • 2017
  • This study aimed to output augmented reality display using chroma-key so that power tiller simulator can be operated smoothly while wearing the head mounted display. In this paper, we propose a chroma-eliminating image filtering method. Experimental results show that the maximum and minimum values of hue, saturation and intensity were 0.52, 0.153, 0.57, 0.16, 1, and 0.12, respectively. A keypad was used to set the initial position of augmented reality adjusted with the front, back, top, bottom, left, and right buttons. The initial position value is always maintained and managed according to the trailer attachment and detachment. Finally, we show that the augmented reality merged with virtual image and the acquired image of operation device using coordinate values obtained from the HMD and the position tracking sensor as relative coordinates in Unity program that is the ultimate game development platform.

CNN based data anomaly detection using multi-channel imagery for structural health monitoring

  • Shajihan, Shaik Althaf V.;Wang, Shuo;Zhai, Guanghao;Spencer, Billie F. Jr.
    • Smart Structures and Systems
    • /
    • v.29 no.1
    • /
    • pp.181-193
    • /
    • 2022
  • Data-driven structural health monitoring (SHM) of civil infrastructure can be used to continuously assess the state of a structure, allowing preemptive safety measures to be carried out. Long-term monitoring of large-scale civil infrastructure often involves data-collection using a network of numerous sensors of various types. Malfunctioning sensors in the network are common, which can disrupt the condition assessment and even lead to false-negative indications of damage. The overwhelming size of the data collected renders manual approaches to ensure data quality intractable. The task of detecting and classifying an anomaly in the raw data is non-trivial. We propose an approach to automate this task, improving upon the previously developed technique of image-based pre-processing on one-dimensional (1D) data by enriching the features of the neural network input data with multiple channels. In particular, feature engineering is employed to convert the measured time histories into a 3-channel image comprised of (i) the time history, (ii) the spectrogram, and (iii) the probability density function representation of the signal. To demonstrate this approach, a CNN model is designed and trained on a dataset consisting of acceleration records of sensors installed on a long-span bridge, with the goal of fault detection and classification. The effect of imbalance in anomaly patterns observed is studied to better account for unseen test cases. The proposed framework achieves high overall accuracy and recall even when tested on an unseen dataset that is much larger than the samples used for training, offering a viable solution for implementation on full-scale structures where limited labeled-training data is available.

The Effect of NiO Addition to the PNN-PZT Piezoelectric Ceramics on Piezoelectric Properties (Pb(Ni1/3Nb2/3)O3-PZT 세라믹스 고용체에서 과잉 NiO첨가에 따른 압전특성 변화)

  • Choi Y. G.;Son Y. J.;Kweon J. C.;Cho K. W.;Yoon M. S.;Kim I. H.;Kim Y. M.;Ur S. C.
    • Korean Journal of Materials Research
    • /
    • v.15 no.6
    • /
    • pp.413-418
    • /
    • 2005
  • Perovskite $Pb(Ni_{1/3}Nb_{2/3})O_3-Pb(Zr,Ti)O_3[PNN-PZT]$ ceramics were synthesized by conventional ceramic processing technique. In order to modify piezoelectric properties for sensor application in this system, NiO addition was considered to provide $Ni^{+2}$ as an acceptor, which was known to occupy with B site in the structure. The effect of NiO addition up to $8\;mol\%$ on the following piezoelectric properties as well as sintering properties was investigated. When NiO added more than $1\;mol\%$, average grain size was decreased and second phase was found to form. Moreover, the second phase caused decrease in relative dielectric constant $(\varepsilon_{33}T/\varepsilon0)$, electro-mechanical coupling factor $(k_p)$, and piezoelectric charge constant $(d_{33})$, while increasing mechanical quality factor $(Q_m)$. When $1\;mol\%$ NiO was added, density, dielectric properties and piezoelectric properties were abruptly increased.

Development of a prototype simulator for dental education (치의학 교육을 위한 프로토타입 시뮬레이터의 개발)

  • Mi-El Kim;Jaehoon Sim;Aein Mon;Myung-Joo Kim;Young-Seok Park;Ho-Beom Kwon;Jaeheung Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.257-267
    • /
    • 2023
  • Purpose. The purpose of the study was to fabricate a prototype robotic simulator for dental education, to test whether it could simulate mandibular movements, and to assess the possibility of the stimulator responding to stimuli during dental practice. Materials and methods. A virtual simulator model was developed based on segmentation of the hard tissues using cone-beam computed tomography (CBCT) data. The simulator frame was 3D printed using polylactic acid (PLA) material, and dentiforms and silicone face skin were also inserted. Servo actuators were used to control the movements of the simulator, and the simulator's response to dental stimuli was created by pressure and water level sensors. A water level test was performed to determine the specific threshold of the water level sensor. The mandibular movements and mandibular range of motion of the simulator were tested through computer simulation and the actual model. Results. The prototype robotic simulator consisted of an operational unit, an upper body with an electric device, a head with a temporomandibular joint (TMJ) and dentiforms. The TMJ of the simulator was capable of driving two degrees of freedom, implementing rotational and translational movements. In the water level test, the specific threshold of the water level sensor was 10.35 ml. The mandibular range of motion of the simulator was 50 mm in both computer simulation and the actual model. Conclusion. Although further advancements are still required to improve its efficiency and stability, the upper-body prototype simulator has the potential to be useful in dental practice education.

Characteristics and Fabrication of Complementary Electrochromic Device ( I ) (상보형 일렉트로크로믹 소자의 제조 및 특성 ( I ))

  • Lee, S.Y.;Seo, D.K.;Kim, Y.H.;Cho, T.Y.;Chun, H.G.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.24-34
    • /
    • 1997
  • In this study, two different types of complementary electrochromic devices using amorphous $WO_{3}$ films as a working electrode, $V_{2}O_{5}$ film and NiO film as counter electrodes respectively were investigated. For the devices using amorphous and crystalline $V_{2}O_{5}$ films of $100{\sim}150nm$ thickness with $ITO/WO_{3}/LiClO_{4}-PC/V_{2}O_{5}/ITO$ structure, an optical modulation of $50{\sim}60%$ were obtained at a potential range of $1{\sim}2V$. It has been shown that transmittance and reflectance of light could be electrically controlled by low applied voltage. For the devices with $ITO/WO_{3}/LiClO_{4}-PC/NiO/ITO$ structure in which NiO film was deposited by a RF reactive sputtering, the optical modulation in visible light region (${\lambda}=550nm$) and in near infrared light region (${\lambda}=850nm$) were 25% and 30%, respectively.

  • PDF

Deposition and Characteristics of TiN Thin Films by Atomic Layer Epitaxy (ALE 법에 의한 TiN 박막의 증착 및 특성)

  • Kim, Dong-Jin;Jung, Young-Bae;Lee, Myung-Bok;Lee, Jung-Hee;Lee, Yong-Hyun;Hahm, Sung-Ho;Lee, Jong-Hwa
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.6
    • /
    • pp.43-49
    • /
    • 2000
  • The TiN thin films were deposited by ALE(atomic layer epitaxy) on (100) silicon substrate. The TiN thin films were characterized by means of XRD, 4-point probe, AFM, AES and SEM. TEMAT(terakis(ethyl methy lamino)titanium) and $NH_3$ were injected into the reactor in sequence of TEMAT-$N_2-NH_3-N_2$ to ensure a saturated surface reaction. As a result, the depostion rate of the TiN film was controlled by self-limiting growth mechanism at temperature range form 150 to 220 $^{\circ}C$. Deposited TiN films, all of which show amorphous structure, had a fixed deposition rate of 4.5 ${\AA}$/cycle. The resistivity of 210 ~ 230 ${\mu}{\Omega}{\cdot}$cm and the surface r.m.s. roughness of 7.9 ~ 9.3 ${\AA}$ were measured. When TiN film of 2000 ${\AA}$ were deposited, a excellent step coverage were observed in a trench structure of 0.43${\mu}m$ contacts with 6:1 aspect ratio.

  • PDF

Electrical Properties of 0.77(Bi1/2Na1/2)TiO3-0.23SrTiO3 (BNST23)/PVDF-TrFE Composites (스마트 페인트 센서용 0.77(Bi1/2Na1/2)TiO3-0.23SrTiO3 (BNST23)/PVDF-TrFE 복합소재 제조 및 전기적 특성에 관한 연구)

  • Sung Jae Hyoung;Eun Seo Kang;Yubin Kang;Chae Ryeong Kim;Chang Won Ahn;Byeong Woo Kim;Jae-Shin Lee;Hyoung-Su Han
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.4
    • /
    • pp.433-438
    • /
    • 2024
  • Piezoelectric ceramics play an important role in various electronic applications. However, traditional ceramics are difficult to be used in some complicated structures, due to their low flexibility and high brittleness. To solve this problem, this study prepared and investigated ceramic/polymer composites that can utilize a good flexibility of polymers. Polyvinylidene fluoride-trifluoroethylene (PVDF-TrFE) and 0.77(Bi1/2Na1/2)TiO3-0.23SrTiO3 (BNST23) ceramics were selected to fabricate the composites. Ceramic/polymer composites were prepared using various volume fractions of BNST23 ceramics. The distribution of piezoceramic particles in BNST23/PVDF-TrFE composites was investigated using optical microscopy (OM) and scanning electron microscopy (SEM). The dielectric and piezoelectric properties of the composites were significantly influenced by the volume fraction of the piezoelectric ceramics. As a result, the highest piezoelectric constant (d33) of 56 pC/N was obtained in a composites with 70% volume fraction of BNST23 ceramics. Accordingly, it is expected that BNST23/PVDF-TrFE composites can be applied to various sensor applications.

Effect of Total Resistance of Electrochemical Cell on Electrochemical Impedance of Reinforced Concrete Using a Three-Electrode System (3전극방식을 활용한 철근 콘크리트의 교류임피던스 측정 시 전기화학 셀저항의 영향)

  • Khan, Md. Al-Masrur;Kim, Je-Kyoung;Yee, Jurng-Jae;Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.82-92
    • /
    • 2022
  • This study aims to investigate the effect of total electrochemical cell resistance (TECR) on electrochemical impedance (EI) measurements of reinforced concrete (RC) by electrochemical impedance spectroscopy (EIS) using a three-electrode system. A series of experimental study is performed to measure electrochemical behavior of a steel bar embedded in a concrete cube specimen, with a side length of 200 mm, in various experimental conditions. Main variables include concrete dry conditions, coupling resistance between sensing electrodes and concrete surface, and area of the counter electrode. It is demonstrated that EI values remains stable when the compliant voltage of a measuring device is sufficiently great compared to the potential drop caused by TECR of concrete specimens. It is confirmed that the effect of the coupling resistance of TECR is far more influential than other two factors (concrete dry conditions and area of the counter electrode). The results in this study can be used as a fundamental basis for development of a surface-mount sensor for corrosion monitoring of reinforced concrete structures exposed to wet-and-dry cycles under marine environment.