• Title/Summary/Keyword: 3D imaging system

Search Result 498, Processing Time 0.025 seconds

Development of the Ultra Precision Thermal Imaging Optical System (초정밀 열 영상 현미경 광학계 개발)

  • Yang, Sun-Choel;Won, Jong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.12
    • /
    • pp.15-21
    • /
    • 2010
  • Recently, there is a demand for a thermal imaging microscope in the medical field as well as the semi-conductor industry Although the demand of the advanced thermal imaging microscope has been increased, it is very difficult to obtain the technology of developing a thermal camera, because it is used for defense industry. We developed the ${\times}5$ zoom microscope which has $3\;{\mu}m$ spatial resolution to research the design and fabrication of the IR (Infrared) optical system. The optical system of the IR microscope consists of four spherical lenses and four aspheric lenses. We verified individual sensitivity of each optical parameter as the first order approach to the analysis. And we also performed structure and vibration analysis. The optical elements are fabricated using Freeform 700A. The measurement results of surface roughness and form accuracy using NT 2000 and UA3P are Ra 2.36 nm and P-V $0.13\;{\mu}m$. Finally we ascertained resolution power of $3\;{\mu}m$ using USAF (United State Air Force) 1951 IR resolution test chart.

Generating the Array of Elemental Image efficiently by using Look-Up Table in Integral Imaging System (집적영상 시스템에서 룩업테이블을 사용한 요소영상 배열의 효과적인 생성)

  • Kwon, Young-Man;Kim, Seung-Chul;Kim, Eun-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.12C
    • /
    • pp.1068-1074
    • /
    • 2008
  • In this paper, we propose the algorithm for generating the array of elemental image by using look-up table (L UT) in a computer generated integral imaging system. It makes the LUT independently for the projection point of x and y. The algorithm using LUT to the existing ones needs less computing time to generate the array of elemental image. By comparing the computing time of proposed algorithm with that of the existing algorithms e xperimently, we proved the efficiency of proposed algorithm.

Requirements for Future Digital Radiology System

  • Kim, Y.M.;Park, H.W.;Haynor, D.R.
    • Progress in Medical Physics
    • /
    • v.2 no.1
    • /
    • pp.3-16
    • /
    • 1991
  • Abstract. An area of particularly rapid technological growth in the last 15 years has been medical imaging (conventional X-ray, ultrasound, X-ray computed tomography (CT), magnetic resonance imaging (MRI). As the number and complexity of imaging studies rises, it becomes ever more important to distribute these images and the associated diagnoses in a timely and cost-effective fashion. The purpose of this paper is to describe the requirements for a future digital radiology system which will efficiently handle the large volume of images that generated, add new functionality to improve productivity of physicians, technologists, and other health care providers, and provide enough flexibility to allow the system to grow as medical image technology grows.

  • PDF

In vivo Imaging Biodistribution Profile of a New Macrocyclic Gadolinium Chelate as a Highly Stable Multifunctional MRI Contrast Agent

  • Sung, Bo Kyung;Jo, Yeong Woo;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.1
    • /
    • pp.34-37
    • /
    • 2019
  • Gadolinium contrast agents (CAs) are integral components of clinical magnetic resonance imaging (MRI). However, safety concerns have arisen regarding the use of gadolinium CAs, due to their association with nephrogenic systemic fibrosis (NSF). Furthermore, recently the long-term retention of $Gd^{3+}-based$ CAs in brains patients with normal renal function raised another possible safety issue. The safety concerns of $Gd^{3+}-based$ CAs have been based on the ligand structure of $Gd^{3+}-based$ CAs, and findings that $Gd^{3+}-based$ CAs with linear ligand structures showed much higher incidences of NSF and brain retention of CAs than $Gd^{3+}-based$ CAs with macrocyclic ligand structure. In the current study, we report the in vivo biodistribution profile of a new highly stable multifunctional $Gd^{3+}-based$ CA, with macrocyclic ligand structure (HNP-2006). MR imaging using HNP-2006 demonstrated a significant contrast enhancement in many different organs. Furthermore, the contrast enhanced tumor imaging using HNP-2006 confirmed that this new macrocyclic CA can be used for detecting tumor in the central nervous system. Therefore, this new multifunctional HNP-2006 with macrocyclic ligand structure shows great promise for whole-body clinical application.

An Input/Output Technology for 3-Dimensional Moving Image Processing (3차원 동영상 정보처리용 영상 입출력 기술)

  • Son, Jung-Young;Chun, You-Seek
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.8
    • /
    • pp.1-11
    • /
    • 1998
  • One of the desired features for the realizations of high quality Information and Telecommunication services in future is "the Sensation of Reality". This will be achieved only with the visual communication based on the 3- dimensional (3-D) moving images. The main difficulties in realizing 3-D moving image communication are that there is no developed data transmission technology for the hugh amount of data involved in 3-D images and no established technologies for 3-D image recording and displaying in real time. The currently known stereoscopic imaging technologies can only present depth, no moving parallax, so they are not effective in creating the sensation of the reality without taking eye glasses. The more effective 3-D imaging technologies for achieving the sensation of reality are those based on the multiview 3-D images which provides the object image changes as the eyes move to different directions. In this paper, a multiview 3-D imaging system composed of 8 CCD cameras in a case, a RGB(Red, Green, Blue) beam projector, and a holographic screen is introduced. In this system, the 8 view images are recorded by the 8 CCD cameras and the images are transmitted to the beam projector in sequence by a signal converter. This signal converter converts each camera signal into 3 different color signals, i.e., RGB signals, combines each color signal from the 8 cameras into a serial signal train by multiplexing and drives the corresponding color channel of the beam projector to 480Hz frame rate. The beam projector projects images to the holographic screen through a LCD shutter. The LCD shutter consists of 8 LCD strips. The image of each LCD strip, created by the holographic screen, forms as sub-viewing zone. Since the ON period and sequence of the LCD strips are synchronized with those of the camera image sampling adn the beam projector image projection, the multiview 3-D moving images are viewed at the viewing zone.

  • PDF

A Study on the Method of Generating RPC for KOMPSAT-2 MSC Pre-Processing System (KOMPSAT-2 MSC 전처리시스템을 위한 RPC(Rational Polynomial Coefficient)생성 기법에 관한 연구)

  • 서두천;임효숙
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.417-422
    • /
    • 2003
  • The KOMPSAT-2 MSC(Multi-Spectral Camera), with high spatial resolution, is currently under development and will be launched in the end of 2004. A sensor model relates a 3-D ground position to the corresponding 2-D image position and describes the imaging geometry that is necessary to reconstruct the physical imaging process. The Rational Function Model (RFM) has been considered as a generic sensor model. form. The RFM is technically applicable to all types of sensors such as frame, pushbroom, whiskbroom and SAR etc. With the increasing availability of the new generation imaging sensors, accurate and fast rectification of digital imagery using a generic sensor model becomes of great interest to the user community. This paper describes the procedure to generation of the RPC (Rational Polynomial Coefficients) for KOMPSAT-2 MSC.

  • PDF

A 3-D Vision Sensor Implementation on Multiple DSPs TMS320C31 (다중 TMS320C31 DSP를 사용한 3-D 비젼센서 Implementation)

  • Oksenhendler, V.;Bensrhair, Abdelaziz;Miche, Pierre;Lee, Sang-Goog
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.124-130
    • /
    • 1998
  • High-speed 3D vision systems are essential for autonomous robot or vehicle control applications. In our study, a stereo vision process has been developed. It consists of three steps : extraction of edges in right and left images, matching corresponding edges and calculation of the 3D map. This process is implemented in a VME 150/40 Imaging Technology vision system. It is a modular system composed by a display, an acquisition, a four Mbytes image frame memory, and three computational cards. Programmable accelerator computational modules are running at 40 MHz and are based on TMS320C31 DSP with a $64{\times}32$ bit instruction cache and two $1024{\times}32$ bit internal RAMs. Each is equipped with 512 Kbytes static RAM, 4 Mbytes image memory, 1 Mbytes flash EEPROM and a serial port. Data transfers and communications between modules are provided by three 8 bit global video bus, and three local configurable pipeline 8 bit video bus. The VME bus is dedicated to system management. Tasks between DSPs are distributed as follows: two DSPs are used to edges detection, one for the right image and the other for the left one. The last processor computes the matching process and the 3D calculation. With $512{\times}512$ pixels images, this sensor generates dense 3D maps at a rate of about 1 Hz depending of the scene complexity. Results can surely be improved by using a special suited multiprocessors cards.

  • PDF

Creation of 3D Maps for Satellite Communications to Support Ambulatory Rescue Operations

  • Nakajima, Isao;Nawaz, Muhammad Naeem;Juzoji, Hiroshi;Ta, Masuhisa
    • Journal of Multimedia Information System
    • /
    • v.6 no.1
    • /
    • pp.23-30
    • /
    • 2019
  • A communications profile is a system that acquires information from communication links to an ambulance or other vehicle moving on a road and compiles a database based on this information. The equipment (six sets of HDTVs, fish-eye camera, satellite antenna with tracking system, and receiving power from the satellite beacon of the N-star) mounted on the roof of the vehicle, image data were obtained at Yokohama Japan. From these data, the polygon of the building was actually produced and has arranged on the map of the Geographical Survey Institute of a 50 m-mesh. The optical study (relationship between visibility rate and elevation angle) were performed on actual data taken by fish-eye lens, and simulated data by 3D-Map with polygons. There was no big difference. This 3D map system then predicts the communication links that will be available at a given location. For line-of-sight communication, optical analysis allows approximation if the frequency is sufficiently high. For non-line-of-sight communication, previously obtained electric power data can be used as reference information for approximation in certain cases when combined with predicted values calculated based on a 3D map. 3D maps are more effective than 2D maps for landing emergency medical helicopters on public roadways in the event of a disaster. Using advanced imaging technologies, we have produced a semi-automatic creation of a high-precision 3D map at Yokohama Yamashita Park and vicinity and assessed its effectiveness on telecommunications and ambulatory merits.

A Simulation System of Total Knee Replacement Surgery for Extracting 3D Surgical Parameters (슬관절 전치환술용 3차원 시술변수 추출 시스템)

  • Jun, Yong-Tae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.5
    • /
    • pp.315-322
    • /
    • 2011
  • The goal of total knee replacement (TKR) surgery is to replace patient's knee joint with artificial implants in order to restore normal knee joint functions. Since mismatched knee implants often cause a critical balancing problem and short durability, designing a well-fitted implant to a patient's knee joint is essential to improve surgical outcomes. We developed a software system that three-dimensionally (3D) simulates TKR surgery based upon 3D knee models reconstructed from computed tomography (CT) imaging. The main task of the system was to extract precise 3D anatomical parameters of a patient's knee that were directly used to determine a custom fit implant and to virtually perform TKR surgery. The virtual surgery was simulated by amputating a 3D knee model and positioning the determined implant components on the amputated knee. The test result shows that it is applicable to derive surgical parameters, determine individualized implant components, rehearse the whole surgical procedure, and train medical staff or students for actual TKR surgery. The feasibility and verification of the proposed system is described with examples.