• 제목/요약/키워드: 3D body shape

검색결과 387건 처리시간 0.028초

뉴 시니어 여성을 위한 아웃도어 웨어 디자인 개발 - CLO 3D를 활용한 여름용 상의 디자인 - (Design Development of Shirts in Outdoor-Wear for New Senior Women's Using 3D Simulation Software - CLO 3D -)

  • 지경하;최윤미
    • 복식
    • /
    • 제65권5호
    • /
    • pp.62-73
    • /
    • 2015
  • The aim of this research is to propose the final shirt design modified for new senior women that fulfills their emotional and physical needs. The modifications were based on the results of in-depth interviews and literature search, and the study was conducted in order to understand the desires and preferences of senior women, as consumption of outdoor-wear by the group continues to increase. To develop the design of outdoor-wear that satisfies the physical and emotional qualities and preference of the new senior women, six different designs with lines, combined materials, as well as materials that were layered, pleated and draped were proposed using virtual-dressing simulation software. Then, the modified designs were derived from the six original designs by reflecting the opinions collected in the in-depth interviews with eleven women in their 50s. The responses in the interviewed showed a preference for lines, pleats and layers, as these features made the clothes look trendy, gave it a slender-look, and improved the body shape of the women. As the color is the critical factor for outdoor-wear, there was an overwhelming preference for primary colors by the women, which was in contrast to their color preference in general clothes. A sleeve design modification was proposed to convert the half-sleeves to 3/4-long sleeves in order to account for changes in body temperature at menopause, and to satisfy the aesthetic needs for covering wrinkles. Research of new senior outdoor-wear designs will help segment and differentiate strategies for the increasingly fierce competing outdoor market, as well as l provide directions in the design creation process using the simulation of 3D virtual model.

Design Consideration of Body-Tied FinFETs (${\Omega}$ MOSFETs) Implemented on Bulk Si Wafers

  • Han, Kyoung-Rok;Choi, Byung-Gil;Lee, Jong-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제4권1호
    • /
    • pp.12-17
    • /
    • 2004
  • The body-tied FinFETs (bulk FinFETs) implemented on bulk Si substrate were characterized through 3-dimensional device simulation. By controlling the doping profile along the vertical fin body, the bulk FinFETs can be scaled down to sub-30 nm. Device characteristics with the body shape were also shown. At a contact resistivity of $1{\times}10^{-7}\;{\Omega}\;cm^2$, the device with side metal contact of fin source/drain showed higher drain current by about two. The C-V results were also shown for the first time.

Dicom file을 이용하여 만든 신체 맞춤형 3D print 손가락 보조기 제작 (Produced Body Customized 3D Print Finger Brace using Dicom File)

  • 최현우;박지은;김정훈;서안나;이종민
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.597-603
    • /
    • 2019
  • 임상에서 사용하는 진단 검사 장치인 전산화 단층촬영기(CT)를 이용하여 Dicom 파일을 획득하였습니다. Dicom 파일과 3D 프로그램, 3D 프린터로 손가락 보조기(Finger brace)를 제작하였습니다. 손가락 보조기(Finger brace)는 인체를 대상으로 하기 때문에 형태의 정밀도가 매우 중요합니다. 3D Print는 정밀도가 우수하고, 재료가 다양하고, 출력 시간이 짧은 이점이 있습니다. 임상에서는 알루미늄 보호대나 의료기 업체의 손가락 보호대가 한정적입니다. 3D 프린터로 손가락 보조기(Finger brace)를 제작하면, 환자의 손가락 외상, 질병, 변형의 치료에 이용할 수 있는 정밀한 형태의 맞춤형 손가락 보조기(Finger brace)를 환자에게 적용할 수 있을 것이라고 기대합니다.

3차원 스캔 데이터로부터의 인체 팔, 다리 형상 복원 (Human Limbs Modeling from 3D Scan Data)

  • 현대은;윤승현;김명수
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제8권4호
    • /
    • pp.1-7
    • /
    • 2002
  • 본 논문에서는 3차원 인체 형상 스캔 데이터로부터 팔, 다리형상을 복원하는 방법을 제시한다. 이 방법에서는 팔, 다리 스캔 데이터의 대략적인 형상을 나타내는 기반 곡면과 자세한 세부 현상을 나타내는 displacement 맵의 이중구조로 형상을 복원한다. 팔, 다리 부분의 스캔 데이터 형상은 골격을 따라 스윕하는 타원체로 근사되며, 이 타원체 스윕을 부드럽게 감싸는 envelope 곡면으로 기반 곡면을 생성한다. 타원체 스윕의 envelope 곡면은 빠른 계산을 위해 골격을 따라 추출되는 타원의 스윕 곡면으로 근사된다. 기반 곡면에 대한 스캔 데이터 점들의 displacement는 각 단면 타원으로의 매핑을 통해 스칼라 값으로 구해지며, 다단계 스플라인 함수를 이용하여 매개화된 displacement 맵을 구성한다. 이 과정에서 복원된 형상 위의 점들은 해당하는 타원체 상으로 매핑된다. 본 방법을 통하여 팔, 다리의 간결한 형상 표현을 추출할 수 있으며, 매핑된 타원체를 이용하여 형상을 빠르고 사실적으로 변형할 수 있다.

  • PDF

Development of Ergonomic Leg Guard for Baseball Catchers through 3D Modeling and Printing

  • Lee, Hyojeong;Eom, Ran-i;Lee, Yejin
    • 패션비즈니스
    • /
    • 제20권3호
    • /
    • pp.17-29
    • /
    • 2016
  • To develop baseball catcher leg guards, 3-dimensional (3D) methodologies, which are 3D human body data, reverse engineering, modeling, and printing, optimized guard design for representative positions. Optimization was based on analysis of 3D body surface data and subjective evaluation using 3D printing products. Reverse engineering was used for analysis and modeling based on data in three postures: standing, $90^{\circ}$ knee flexion, and $120^{\circ}$ knee flexion. During knee flexion, vertical skin length increased, with the thigh and knee larger in anterior area compared to the horizontal dimension. Moreover, $120^{\circ}$ knee flexion posture had a high radius of curvature in knee movement. Therefore, guard designs were based on increasing rates of skin deformation and numerical values of radius of curvature. Guards were designed with 3-part zoning at the thigh, knee, and shin. Guards 1 and 2 had thigh and knee boundaries allowing vertical skin length deformation because the shape of thigh and knee significantly affects to its performance. Guard 2 was designed with a narrower thigh and wider knee area than guard 1. The guards were manufactured as full-scale products on a 3D printer. Both guards fit better in sitting than standing position, and guard 2 received better evaluations than guard 1. Additional modifications were made and an optimized version (guard 3) was tested. Guard 3 showed the best fit. A design approach based on 3D data effectively determines best fitting leg guards, and 3D printing technology can customize guard design through immediate feedback from a customer.

3D 가상착의 시스템을 활용한 노년 남성의 슬랙스 원형 설계 (Developing of slacks clothing pattern for the elderly men using a 3D virtual garment simulation system)

  • 임지영
    • 복식문화연구
    • /
    • 제31권5호
    • /
    • pp.627-639
    • /
    • 2023
  • This study seeks to increase the satisfaction of elderly men when purchasing and wearing ready-to-wear clothes by designing a slacks pattern suitable for their body type, which is determined by analyzing their lower bodies using virtual avatars and 3D virtual simulation system. The study found the following. First, based on virtual visualization of the comparison slacks pattern, the waistline position was consistently the lowest scored question among the evaluation survey items. Interpretation of this dissatisfaction suggests that, because the front waistline falls below the abdomen, the lower body, and especially the abdominal shape, is unpleasantly emphasized. Second, by using a virtual simulation system, the study developed a new slacks pattern that considered the concerns of elderly men. The primary measurement changes were as follows: front waist girth W/4+1.5cm+0.5cm, back waist girth W/4+1.5cm-0.5cm, front hip girth H/4+2.5cm-0.5cm, back hip girth H/4+2.5cm+0.5cm. Third, the new slacks pattern's appearance was evaluated more highly than the comparison pattern, confirming the new pattern's appropriateness for elderly men. This study demonstrates how slacks and other clothing patterns designed in a 3D virtual garment simulator can be used to design more appealing clothing for elderly men, increasing the satisfaction of wearing ready-made clothes at older ages.

A numerical study on the seepage failure by heave in sheeted excavation pits

  • Koltuk, Serdar;Fernandez-Steeger, Tomas M.;Azzam, Rafig
    • Geomechanics and Engineering
    • /
    • 제9권4호
    • /
    • pp.513-530
    • /
    • 2015
  • Commonly, the base stability of sheeted excavation pits against seepage failure by heave is evaluated by using two-dimensional groundwater flow models and Terzaghi's failure criterion. The objective of the present study is to investigate the effect of three-dimensional groundwater flow on the heave for sheeted excavation pits with various dimensions. For this purpose, the steady-state groundwater flow analyses are performed by using the finite element program ABAQUS 6.12. It has been shown that, in homogeneous soils depending on the ratio of half of excavation width to embedment depth b/D, the ratio of safety factor obtained from 3D analyses to that obtained from 2D analyses $FS_{(3D)}/FS_{(2D)}$ can reach up to 1.56 and 1.34 for square and circular shaped excavations, respectively. As failure body, both an infinitesimal soil column adjacent to the wall (Baumgart & Davidenkoff's criterion) and a three-dimensional failure body with the width suggested by Terzaghi for two-dimensional cases are used. It has been shown that the ratio of $FS_{(Terzaghi)}/FS_{(Davidenkoff)}$ varies between 0.75 and 0.94 depending on the ratio of b/D. Additionally, the effects of model size, the shape of excavation pit and anisotropic permeability on the heave are studied. Finally, the problem is investigated for excavation pits in stratified soils, and important points are emphasized.

3-D gravity terrain inversion for high resolution gravity data analysis

  • Lee Heuisoon;Park Gye-Soon;Kwon Byung-Doo;Oh Seok Hoon;Yang Junmo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.379-382
    • /
    • 2003
  • In gravity data correction process, mass effect of the upper part of base level is removed with Bouguer density. Usually, Bouguer density is estimated as a mean density in the field area. But, this may causes a serious problem when ore body is in the area. To overcome this problem, we tried to apply a new method mixing up mass corrections and inversion (3DGTI). 3-D Gravity Terrain Inversion (3DGTI) includes information of topography and distribution of Bouguer density. For this method does not remove the mass effect above base level, it is no longer useless to use Bouguer density. Numerical model tests have shown that the 3DGIT successfully retrieves the anomalous subsurface density distribution of both surface and deeper layers. Model tests shows that this method shows better results than those of conventional one, especially when main target is ore body. The inversion result well delineates the three-dimensional shape of the intruded granite body and basement.

  • PDF

3차원 테크놀러지를 이용한 여성용 수영복의 가슴부위 외관 및 패턴 기능성 향상에 관한 연구 (3D Pattern Development of Functional Women's Swimwear To Improve the Appearance and Stability of Chest Region)

  • 유정자;홍경희
    • 한국생활과학회지
    • /
    • 제21권2호
    • /
    • pp.285-298
    • /
    • 2012
  • Considerable number of women are enjoying swimming, however, the chest-region of swimsuits including cup inserts are not stable during swimming. The purpose of this study was to explore alternate designs and methods of stabilizing the breast cup to the swimmer's body by using 3D technology to design and position the pad and cup pattern of the swimming suit. To position the pad optimally, a 3D pattern of a nude woman was divided into blocks and different reduction rates were applied to blocks around the outlines of the breast. Two types of 3D patterns were developed. The first, referred to as the 'basic 3D pattern' provided for the curved surface of the breast point to be maintained with the remaining slack distributed evenly along the neckline, armhole and side seam. The second, referred to as the '1/3 shoulder moved 3D pattern' ignored the curved nature of the breast point by overlapping, with the resulting position of the shoulder strip moved toward the center. Three women of corresponding size and body shape evaluated the two 3D pattern designs as well as the conventional 2D pattern style of swimsuit. Respondents rated the'the basic 3D pattern' design highest in terms of stability and easy of movement in the chest region.

Lateral Body Shapes of Males in Their 20s for the Development of Educational Dress Forms (Part 2)

  • Yoo, Hyun;Shim, Boo-Ja
    • 패션비즈니스
    • /
    • 제9권3호
    • /
    • pp.47-63
    • /
    • 2005
  • The study with the subjects at 200 adult males in Busan in their 20s had a purpose at analyzing lateral body shapes to develop men's educational dress forms. The following are the conclusions: 1. Comparison at the Body Dimensions at Busan Male Adults in Their 20s and the 5th Survey at Korean Body Measurement In the comparison at the Busan and national body dimensions by way at Mollison's relative deviation, all compared items were under the deviation of 0.7. Therefore, the sample of Busan male grown-ups is understood io represent the body shapes of the average Korean male adults in their 20s. 2. Results of Lateral Body Shape Classification From factor analysis, seven factors were produced to explain 75.45% of all variables. Those 7 factors to compose lateral body shapes were hip prominence, back-neck sides, upper body's front-back depth, lateral upper body depth, hip-waist depth, front chest-waist depth, and hip and waist height. Cluster analysis revealed four characteristic lateral body shapes. Type 1 with the appearance rate of 11.70%, named D, had the greatest upper chest angle and tanterior neck lower angle. The front side was more developed. Type 2 with 33.51%, named I, was generally long and slender. Type 3 with 24.47%, named d, had the biggest depth differences in hip-chest as well as more prominent back hip. Type 4 with 30.32%, named q, had the biggest dorsal upper angle and the tiniest chest upper angle as the back area was a little bent.