• Title/Summary/Keyword: 3D body data

Search Result 858, Processing Time 0.028 seconds

A Study of Hydrodynamic Forces Acting on a Ship Hull Under Lateral Low Speed Motion (저속 횡 이동하는 선박의 선체에 작용하는 유체력에 관한 연구)

  • 이윤석;김순갑
    • Journal of the Korean Institute of Navigation
    • /
    • v.23 no.2
    • /
    • pp.29-42
    • /
    • 1999
  • An accurate method of estimating ship maneuverability needs to be developed to evaluate precisely and improve the maneuverability of ships according to the water depth. In order to estimate maneuverability by a mathematical model. The hydrodynamic forces acting on a ship hull and the flow field around the ship in maneuvering motion need to be estimated. The ship speed new the berth is very low and the fluid flow around a ship hull is unsteady. So, the transient fluid motion should be considered to estimate the drag force acting on the ship hull. In the low speed and short time lateral motion, the vorticity is created by the body and grow up in the acceleration stage and the velocity induced by the vorticity affect to the body in deceleration stage. For this kind of problem, CFD is considered as a goof tool to understand the phenomena. In this paper, the 2D CFD code is used for basic consideration of the phenomena to solve the flow in the cross section of the ship considering the ship is slender and the water depth is large enough. The flow fields Added and hydrodynamic forces for the some prescribed motions are computed and compared with the preliminary experiment results. The comparison of the force with measurement is shown a fairly good agreement in tendency. The 3D Potential Calculation based on the Hess & Smith Theory is employed to predict the surge, sway added mass and yaw added moment of inertia of hydrodynamic coefficients for M/V ESSO OSAKA according to the water depth. The results are also compared with experimental data. Finally, the sway added mass of hydrodynamic coefficients for T/S HANNARA is suggested in each water depth.

  • PDF

A Study on the Body Type of Hanwoo(Korean Cattle) Steer by Using Principal Components Analysis (주성분 분석을 이용한 거세한우의 체형분류에 관한 연구)

  • Ha, D.W.;Kim, H.C.;Kim, B.W.;Lee, M.Y.;Lee, J.H.;Shin, C.K.;Do, C.H.;Lee, J.G.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.643-652
    • /
    • 2002
  • Data were consisted of the ten body measurements (withers height, rump height, body length, chest depth, chest width, rump width, rump length, thurls width, hipbone width and chest girth) of 642 steers (Korean cattle), which was entered in the National Beef Quality Contest hosted by the Korea Animal Improvement Association from 1997 to 2001. A principal components analysis was used to classify the body types of the steers, and estimate the correlations between carcass traits and principal components for the body measurements of the first, second, third and fourth period, respectively. The first principal component of body measurements at the first, second, third and fourth period accounted for 76.0%, 83.0%, 72.7% and 57.4% of the total variance, respectively. The sum of first, second and third principal component at each period accounted for 86.69%, 90.49%, 84.62% and 77.26% of the total variance, respectively. At each period, all the first principal component of the body measurements were positive and it generally showed large framed body shape. The size of body was influenced mostly by chest depth(0.328${\sim}$0.339) and rump length(0.325${\sim}$0.341). The second, third and fourth principal component at the each period were various. There were positive correlations between principal components index of each period and carcass traits such as carcass weight(0.539${\sim}$0.755), average daily gain(0.256${\sim}$0.564), backfat thickness(0.227${\sim}$0.280), and eye muscle area(0.187${\sim}$0.344). The correlation with yield grade index(-0.246${\sim}$-0.110), however, was negative. The correlation with marbling score(0.066${\sim}$0.099) was low or statistically insignificant. According to principal component indexes of the second, third, and fourth components, the correlations with the carcass traits were various. There were no large differences between the correlations of the single body measurement trait with the carcass traits and the correlations of the first principal component indexes with the carcass traits.

Development of a Bodice Prototype Drafting Method for 20s Plus-size Women

  • Cha, Su-Joung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.4
    • /
    • pp.99-110
    • /
    • 2022
  • This study attempted to develop a bodice prototype that is the basis for the production of upper body clothing for 20s plus-size women who have distinct characteristics from women with general body types. Through this, it was intended to provide basic data necessary for the development of plus-size women's clothing, which is revitalizing the market due to the increase in the obese population. Through the first evaluation of appearance and abdominal pressure, patterns such as moving the side neck, adding the amount of armhole dart, and adding the amount of sagging were modified. Through the second evaluation, corrections such as vertical side lines, reduction of the neck of the back center line, and adding the amount of armhole darts were performed. Through the third evaluation, the final pattern drafting method was developed by vertically modifying the side line and adding the amount of back armhole darts. In the case of 20s plus-size female body types, a drafting method distinguished from the general body type was required in the method of setting the side and hem due to the protrusion of the abdomen. This study can be said to be meaningful in that it proposed a bodice prototype drafting method suitable for the body type of 20s plus-size women. In the follow-up study, it is thought that the wearability should be evaluated through actual garment wearing.

The Dosimetric Data of 10 MV Linear Accelerator Photon Beam for Total Body Irradiation (전신 방사선조사를 위한 10MV 선형가속기의 선량측정)

  • Ahn Sung Ja;Kang Wee-Saing;Park Seung Jin;Nam Taek Keun;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • Purpose : This study was to obtain the basic dosimetric data using the 10 MV X-ray for the total body irradiation. Materials and Methods : A linear accelerator photon beam is planned to be used as a radiation source for total body irradiation (TBI) in Chonnam University Hospital. The planned distance from the target to the midplane of a patient is 360cm and the maximum geometric field size is 144cm x 144cm. Polystyrene phantom sized $30{\times}30{\times}30.2cm^3$ and consisted of several sheets with various thickness, and a parallel plate ionization chamber were used to measure surface dose and percent depth dose (PDD) at 345cm SSD, and dose profiles. To evaluate whether a beam modifier is necessary for TBI, dosimetry in build up region was made first with no modifier and next with an 1cm thick acryl plate 20cm far from the polystyrene phantom surface. For a fixed sourec-chamber distance, output factors were measured for various depth. Results : As any beam modifier was not on the way of radiation of 10MV X-ray, the $d_{max}$ and surface dose was 1.8cm and $61\%$, respectively, for 345cm SSD. When an 1cm thick acryl plate was put 20cm far from polystyrene phantom for the SSD, the $d_{max}$ and surface dose were 0.8cm and $94\%$, respectively. With acryl as a beam spoiler, the PDD at 10cm depth was $78.4\%$ and exit dose was a little higher than expected dose at interface of exit surface. For two-opposing fields for a 30cm phantom thick phantom, the surface dose and maximum dose relative to mid-depth dose in our experiments were $102.5\%$ and $106.3\%$, respectively. The off-axis distance of that point of $95\%$ of beam axis dose were 70cm on principal axis and 80cm on diagonal axis. Conclusion: 1. To increase surface dose for TBI by 10MV X-ray at 360cm SAD, 1cm thick acrylic spoiler was sufficient when distance from phantom surface to spoiler was 20cm. 2. At 345cm SSD, 10MV X-ray beam of full field produced a satisfiable dose uniformity for TBI within $7\%$ in the phantom of 30cm thickness by two-opposing irradiation technique. 3. The uniform dose distribution region was 67cm on principal axis of the beam and 80cm on diagonal axis from beam axis. 4. The output factors at mid-point of various thickness revealed linear relation with depth, and it could be applicable to practical TBI.

  • PDF

A study on the comparing visual images between the Real garment and the 3D garment simulation of flare skirts (플레어 스커트의 실제착의와 가상착의 이미지 비교)

  • Kim, Hyun-Ah;Ryu, Hyo-Seon;Lee, Joo-Hyun;Nam, Yun-Ja
    • Science of Emotion and Sensibility
    • /
    • v.14 no.3
    • /
    • pp.385-394
    • /
    • 2011
  • The purpose of this research is to compare and analyze visual images between the Real garment and the 3D garment simulation with the various fabrics of flare skirts and to analyze the correlation between mechanical properties and visual images. The picture images (printed on paper) of the Real garment and the 3D garment simulation of experimental flare skirts were shown to the evaluation group of women in their 20s majoring in clothing and textiles, and were evaluated by questionnaires with 32 adjectives. SPSS Version 12.0 statistics program was utilized to analyze data. Factor analysis, One Way ANOVA, T-test and Duncan test were used to investigate visual effect of the Real garment and the 3D garment simulation. As the result of conducting factor analysis on the visual appearance, the images were driven with five factors: 'drapeability', 'attractive', 'body compensation', 'bulkiness', 'activeness'. Visual images were significantly related with mechanical properties of various fabrics, and the visual images between 3D garment simulations and real garment differed with various fabrics and their mechanical properties. Visual images of silk and polyester group, cotton, linen and wool group were significantly related with weight and thickness of kinds of fabrics.

  • PDF

Developemtn of the external fixator for a bone fracture (골절치료용 체외고정기기 개발을 위한 연구)

  • 윤희열
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.310-315
    • /
    • 2000
  • In this paper, the problems of the external fixator that have developed for a distal radius fracture so far are analyzed, and accordingly, the characterizations, which must have a prototype, are arranged. C-Arm is used. This instrument makes it possible for the real play of the internal body by x-ray permeability. From this data, it is possible to induce important design factors. Finally, a basic mechanism, which has to be applied, is decided, and the Solid Edge program, which used a 3-D design tool, completes then total instrument design.

  • PDF

Chaos Analysis of Major Joint Motions for Young Males During Walking (보행시 젊은 남성에 대한 상.하체 주요 관절 운동의 카오스 분석)

  • Park, Jung-Hong;Kim, Kwang-Hoon;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.8
    • /
    • pp.889-895
    • /
    • 2007
  • Quantifying dynamic stability is important to assessment of falling risk or functional recovery for leg injured people. Human locomotion is complex and known to exhibit nonlinear dynamical behaviors. The purpose of this study is to quantify major joints of the body using chaos analysis during walking. Time series of the chaotic signals show how gait patterns change over time. The gait experiments were carried out for ten young males walking on a motorized treadmill. Joint motions were captured using eight video cameras, and then three dimensional kinematics of the neck and the upper and lower extremities were computed by KWON 3D motion analysis software. The correlation dimension and the largest Lyapunov exponent were calculated from the time series to quantify stabilities of the joints. This study presents a data set of nonlinear dynamic characteristics for eleven joints engaged in normal level walking.

A Research on Purchase Behavior and Fit of Men′s Ready-made Suit for Koran Adult Men (성인 남성의 신사복 구매행동과 맞음새에 관한 조사 연구)

  • 박진영;손희순
    • The Research Journal of the Costume Culture
    • /
    • v.9 no.1
    • /
    • pp.45-60
    • /
    • 2001
  • The purpose of this research is to offer basic data for the study of men's suit by investigating purchase behavior and fit of men's ready-made suit for Koran adult men. The subjects were male who aged 25∼39 and resided in Seoul, Kyunggi and Chungnam regions. The results of the research are summarized as the following : 1. Male consumers purchase suit most frequency at department, specially stores. As the consumers grow older dependency on their spouses'opinion for purchase decision increases. The standards of purchasing are stated to e design, price and color. 2. the male consumers are generally knowledgeable about the current sizing system. Yet, the knowledge is confused with the pst and present systems. 3. When the male consumers purchase, they consider mainly for the fit of th d\\body part are shoulders for the jacket and waist, hip for the pants. 4. The attitude to toward the combination of sizes for the jacket is comparatively satisfaction than pants. Specially, most negative part of jacket is the length of sleeve.

  • PDF

COMPARATIVE STUDY ON TURBULENCE MODELS FOR SUPERSONIC FLOW AT HIGH ANGLE OF ATTACK (초음속 고받음각 유동을 위한 난류 모델 비교 연구)

  • Park, M.Y.;Park, S.H.;Lee, J.W.;Byun, Y.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.45-49
    • /
    • 2007
  • Asymmetric force and vibration caused by separation flow at high angle of attack affect the stability of supersonic missile. As a preliminary study we verified the effect of turbulence model through general 3-D slender body for the supersonic flow at high angle of attack. ${\kappa}-{\omega}$ Wilcox model, ${\kappa}-{\omega}$ Wilcox-Durbin+ model, ${\kappa}-{\omega}$ shear-stress transport model, and Spalart-Allmaras one equation model are used. Grid sensitivity test was performed with three different grid system. results show that all models are in good agreement with the experimental data.

  • PDF

Development of a Mathematical Model for Effect of Scoliosis Surgical Correction (구조해석을 통한 척추측만증 교정 분석에 필요한 모델 개발)

  • 김영은;최형연;손창규;이광희;이춘기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1059-1061
    • /
    • 2002
  • A FE model is to develop a personalized biomechanical model of the scoliotic spine that will allow the design of clinical test providing optimal estimation of the post-operation results. A flexible multi-body model of the spine including rib cage, clavicle, and scapular was developed to simulate several mobility simulations. Vertebrae, clavicle and scapular were represented using rigid bodies and ribs and sternum were modeled as flexible bodies. Kinematical Joints and spring elements were used to represent the intervertebral disc and ligaments respectively. Postero-anterior and lateral radiographics of a scoliotic spine were used to represent a 3D reconstruction. CT data for same patient were also used to verify vertebrae rotation driven from postero-anterior and lateral radiographic images. Simulated results showed good reducibility almost uniformly distributed along the spinal segments. It was also found that boundary and loading conditions, required to mimic the operation procedures, were proven to be very sensitive parameters to its results rather than its mechanical properties

  • PDF