• Title/Summary/Keyword: 3D Marker

Search Result 526, Processing Time 0.026 seconds

The Design of Optical Marker for Auto-registering of 3D scan data (3차원 스캐너의 레지스터링 문제 해결을 위한 광학식 마커 설계)

  • 손용훈;양현석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.256-259
    • /
    • 2003
  • This paper proposes OPTICAL MARKER fer registering process - one of the 3D measurement process : scan registering - merging - measurement. If the registering work is carried out manually, it can be accompanied with much time and many errors. Because the patterned marker make registering process automatic, many firms use it now. But the physical shape of existing markers is the source of the data loss caused by hiding surface, and the marker arrangement is the source of the time loss. The optical marker proposed in this paper has marker generator, organized a large number of binary coded control laser diode, separate from 3D scan object. So, it does not take much time for the marker disposition, and it is not the origin of the data loss, and the binary coded laser information make the auto-registering possible.

  • PDF

Consideration of the Effect of Artifact during the Image Guided Radiation Therapy Using the Fiducial Marker (영상 유도 방사선치료 시 Fiducial Marker의 Artifact에 관한 연구)

  • Kim, Jong-Min;Kim, Dae-Sup;Back, Geum-Mun;Kang, Tae-Yeong;Hong, Dong-Ki;Yun, Hwa-Yong;Kwon, Kyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Purpose: The effect of artifact was analyzed, which occurs from fiducial marker during the liver Image Guided Radiation Therapy (IGRT) using the fiducial marker. Materials and Methods: The size of artifact of fixed fiducial marker and length of mobile fiducial marker locus were measured using the On-Board Imager system (OBI) and CT simulator, and 2D-2D matching and 3D-3D matching were carried out, respectively, and at this time, the coordinates transition value of couch was analyzed. Results: The measurement of fixed fiducial marker artifact size indicated CT 4.90, 8.10, 12.90, 19.70 mm and OBI 5.60, 10.60, 14.70, 29.40 mm based on the reference CT slice thickness of 1.25, 2.50, 5.00, and 10.00 mm. Meanwhile, the measurement of mobile fiducial marker locus length indicated CT 42.00, 43.10, 46.50 mm, and OBI 43.40, 46.00, 49.30 mm. The coordinates transition of 1.00, 2.00, and 8.00 mm occurred between 2D-2D matching and 3D-3D matching. Conclusion: It was confirmed that the therapy error increased during IGRT due to the influence of artifact when CT slice thickness increased. Thus, it may be desirable to acquire the image less than 2.50 mm in slice thickness when IGRT is implemented using the fiducial marker.

  • PDF

Marker-less Calibration of Multiple Kinect Devices for 3D Environment Reconstruction (3차원 환경 복원을 위한 다중 키넥트의 마커리스 캘리브레이션)

  • Lee, Suwon
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.10
    • /
    • pp.1142-1148
    • /
    • 2019
  • Reconstruction of the three-dimensional (3D) environment is a key aspect of augmented reality and augmented virtuality, which utilize and incorporate a user's surroundings. Such reconstruction can be easily realized by employing a Kinect device. However, multiple Kinect devices are required for enhancing the reconstruction density and for spatial expansion. While employing multiple Kinect devices, they must be calibrated with respect to each other in advance, and a marker is often used for this purpose. However, a marker needs to be placed at each calibration, and the result of marker detection significantly affects the calibration accuracy. Therefore, a user-friendly, efficient, accurate, and marker-less method for calibrating multiple Kinect devices is proposed in this study. The proposed method includes a joint tracking algorithm for approximate calibration, and the obtained result is further refined by applying the iterative closest point algorithm. Experimental results indicate that the proposed method is a convenient alternative to conventional marker-based methods for calibrating multiple Kinect devices. Hence, the proposed method can be incorporated in various applications of augmented reality and augmented virtuality that require 3D environment reconstruction by employing multiple Kinect devices.

Usability of 2D/2D Match for Image Guided Radiotherapy (IGRT) of Prostate Cancer with Fiducial Markers (전립선 암 환자의 영상유도 방사선 치료 시 Fiducial Marker를 이용한 2D/2D Match의 유용성에 대한 연구)

  • Bae, Sun-Myung;Yang, Oh-Nam;Song, Heung-Kwon;Back, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Purpose: To study the efficacy of marker match with using kilovoltage (KV) X-ray among multiple image guidance that referring tree fiducial marker in radiation therapy for prostate cancer patients. Materials and Methods: KV two-dimantional images (anterior-posterior, right-left) and cone-beam CT volumetric images were acquired after setup for patients with three fiducial markers. Compare the position of the fiducial marker of reference plan computed tomography (CT) and of KV, CBCT images; then decide the shift score of X, Y, and Z. This study executed 5 times on 10 patients and analyzed the shift value. Results: In the radiation therapy using fiducial marker, The function of marker match showed the same direction tendency as the CBCT, and showed X, Y, Z difference of about 0.6, 0.7, and 0.8 (unit: mm). Conclusion: Comparing to this, the result of shift value using 2D marker match showed less than 1.0 mm difference. The function of marker match is considered more useful in time-wise and effective dose rather than CBCT. Therefore, Both methods are used to treat patients for prostate cancer.

  • PDF

The study for improve a method of Marker auto- identification (마커 자동 인식 향상 방법에 관한 연구)

  • Lee, Hyun-Seob
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.23-38
    • /
    • 2003
  • The purpose of this study is to develop an improved marker auto-identification algorithm for reduce of data processing time through improve the efficiency of noise elimination and marker separation. The maker auto-identification algorithm was programming named KUMAS used Delphi language. For the study, various experiments were conducted for the verification of KUMAS. and compared two systems of established with the KUMAS. Four different motions - cycling, gait, rotation, and pendulum -, were selected and tested. Motions were filmed 30Hz frames rate per second. ${\chi}^2$ used for statistical analysis. Significant level were ${\alpha}=.05$. The test results were as follow. 1. Increased the success ratio of marker auto-identification. 2. The efficiency of marker auto-identification was remarkably improved through marker separation, noise elimination. 3. The marker auto-identification ability was improved in 2D-image plane include the 3D motion. 4. Significant different were found between KUMAS and B-SYS(established system) with non-input the artificial noise frames, input the artificial noise frames and total frames.

Effects of Feeder Cell Types on Culture of Mouse Embryonic Stem Cell In Vitro

  • Park, Yun-Gwi;Lee, Seung-Eun;Kim, Eun-Young;Hyun, Hyuk;Shin, Min-Young;Son, Yeo-Jin;Kim, Su-Young;Park, Se-Pill
    • Development and Reproduction
    • /
    • v.19 no.3
    • /
    • pp.119-126
    • /
    • 2015
  • The suitable feeder cell layer is important for culture of embryonic stem (ES) cells. In this study, we investigated the effect of two kinds of the feeder cell, MEF cells and STO cells, layer to mouse ES (mES) cell culture for maintenance of stemness. We compare the colony formations, alkaline phosphatase (AP) activities, expression of pluripotency marker genes and proteins of D3 cell colonies cultured on MEF feeder cell layer (D3/MEF) or STO cell layers (D3/STO) compared to feeder free condition (D3/-) as a control group. Although there were no differences to colony formations and AP activities, interestingly, the transcripts level of pluripotency marker genes, Pou5f1 and Nanog were highly expressed in D3/MEF (79 and 93) than D3/STO (61and 77) or D3/- (65 and 81). Also, pluripotency marker proteins, NANOG and SOX-2, were more synthesized in D3/MEF ($72.8{\pm}7.69$ and $81.2{\pm}3.56$) than D3/STO ($32.0{\pm}4.30$ and $56.0{\pm}4.90$) or D3/- ($55.0{\pm}4.64$ and $62.0{\pm}6.20$). These results suggest that MEF feeder cell layer is more suitable to mES cell culture.

The Study of Stable Child English Education Content Using Augmented Reality Solving the Hide of Marker (마커의 가려짐을 해결하여 증강현실을 이용한 안정적 영어 학습 컨텐츠에 대한 연구)

  • Jeon, Soo-Jin;Kim, Young-Seop
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.4
    • /
    • pp.99-102
    • /
    • 2010
  • In this study, the 3- dimensional (3-D) learning contents are suggested using 'Augmented Reality' instead of existing 2-dimensional (2-D) learning methods. At the present, there are some 2-D learning methods using texts, image, pictures, and videos called e-learning. However, these one-way 2-D methods have some disadvantages such as declining learner's immersion and concentration. Thus, the 3-D learning contents using 'Augmented Reality' are suggested to compensate the disadvantages. According to the development of information technology (IT), the augmented reality has many applications to the era of ubiquitous. However, there are some disadvantages when learners use these contents as following; non-augmenting by partially hiding from makers and declining concentration by patterns of the makers. In this study, the beneficial marker which can solve this non-augmenting phenomenon is suggested.

Implementation of Contents System using Color Marker in Mobile AR (모바일 증강현실에서 컬러마커를 이용한 콘텐츠시스템 구현)

  • Lee, Jong-Hyeok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.8
    • /
    • pp.1811-1816
    • /
    • 2012
  • Black marker cause unnatural problems between the existing various contents and marker. To solve this problem, we tested frequency of 3D objects according to the various colors and color placement. Based on this, infant's learning content system based NyARToolkit for the mobile-based augmented reality was implemented. By insert to color marker, We are solved the unnatural problems in the Implemented system. and infant can study seamlessly because concentration increases by the familiar character on the markers.

Evaluation of the Usefulness of the Self-developed Kw-infrared Reflective Marker in Non-coplanar Treatment (비동일면 치료 시 자체 제작한 Kw-infrared Reflective Marker의 유용성 평가)

  • Kwon, Dong-Yeol;Ahn, Jong-Ho;Park, Young-Hwan;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: In radiotherapy that takes into account respiration using a RPM (Real time Position Management, Varian, USA) system, which can treat in consideration of the movement of tumor, infrared reflective markers supplied by manufacturers cannot obtain respiratory signal if the couch rotates at a certain angle or larger. In order to solve this problem, the author developed the 3D infrared reflective marker named 'Kw-marker' that can obtain respiratory signal at any angle, and evaluate its usefulness. Materials and Methods: In order to measure the stability of respiratory signal, we put the infrared reflective marker on the 3D moving phantom that can reproduce respiratory movement and acquired respiratory signal for 3 minutes under each of 3 conditions (A: $couch\;0^{\circ}$, a manufacturer's infrared reflective marker B: $couch\;0^{\circ}$, Kw-marker C: $couch\;90^{\circ}$, Kw-marker). By analyzing the respiratory signal using a breath analysis program (Labview Ver. 7.0), we obtained the peak value, valley value, standard deviation, variation value, and amplitude value. In order to examine the rotation error and moving range of the target, we placed a B.B phantom on the 3D moving phantom, and obtained images at a couch angle of $0^{\circ}$ and $90^{\circ}$ using OBI, and then acquired the X, Y and Z values (mm) of the ball bearing at the center of the B.B phantom. Results: According to the results of analyzing the respiratory signal, the standard deviation at the peak value was A: 0.002, B: 0.002 and C: 0.003, and the stability of respiration for amplitude was A: 0.15%, B: 0.14% and C:0.13%, showing that we could get respiratory signal stably by using the Kw-marker. When the couch rotated $couch\;90^{\circ}$, the mean rotation error of the ball bearing, namely, the target was X: -1.25 mm, Y: -0.45 mm and Z: +0.1 mm, which were within 1.3 mm on the average in all directions, and the difference in the moving range of the target was within 0.3 mm. Conclusion: When we obtained respiratory signal using the Kw-marker in non-coplanar treatment where the couch rotated, we could acquire respiratory signal stably and the Kw-marker was effective enough to substitute for the manufacturer's infrared reflective marker. When the rotation error and moving range of the target were measured, there was little difference, indicating that the displacement of the reflector movement in couch rotation is the cause of change in the scale and amplitude of respiratory signal. If the converted value of amplitude height according to couch angle is studied further and applied, it may be possible to perform non-coplanar phase-based gating treatment.

  • PDF

3D Stereoscopic Augmented Reality with a Monocular Camera (단안카메라 기반 삼차원 입체영상 증강현실)

  • Rho, Seungmin;Lee, Jinwoo;Hwang, Jae-In;Kim, Junho
    • Journal of the Korea Computer Graphics Society
    • /
    • v.22 no.3
    • /
    • pp.11-20
    • /
    • 2016
  • This paper introduces an effective method for generating 3D stereoscopic images that gives immersive 3D experiences to viewers using mobile-based binocular HMDs. Most of previous AR systems with monocular cameras have a common limitation that the same real-world images are provided to the viewer's eyes without parallax. In this paper, based on the assumption that viewers focus on the marker in the scenario of marker based AR, we recovery the binocular disparity about a camera image and a virtual object using the pose information of the marker. The basic idea is to generate the binocular disparity for real-world images and a virtual object, where the images are placed on the 2D plane in 3D defined by the pose information of the marker. For non-marker areas in the images, we apply blur effects to reduce the visual discomfort by decreasing their sharpness. Our user studies show that the proposed method for 3D stereoscopic image provides high depth feeling to viewers compared to the previous binocular AR systems. The results show that our system provides high depth feelings, high sense of reality, and visual comfort, compared to the previous binocular AR systems.