• Title/Summary/Keyword: 3D Air Flow

Search Result 396, Processing Time 0.034 seconds

Study on the Experiment and Numerical Computation of Forced Convection Heat Transfer around Circular Cylinder in a Rectangular Duct (사각덕트 내에서 원형 실린더 주위의 강제대류 열전달에 대한 실험과 수치계산에 관한 연구)

  • 윤영환;김경환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.490-498
    • /
    • 2004
  • This paper measures the forced convective heat transfer from heated cylinder to air flow in a rectangular duct at Re$_{D}$ =2,337, 4,589, 6,621 and 7,944 through experiments. And the heat transfer is computed by 3-D numerical computation in which various turbulent models are applied. It is shown through the comparison of experimental and computed data that numerical computation with standard k-$\varepsilon$ model predicts the experimental data most accurately. Furthermore, the correlation from the computed heat transfer is almost similar to that from the experiment when Re$_{D}$ is greater than 4,589. In addition, the correlation of McAdams is the closest to that from experimental data among various correlations from literature in the range of Reynolds number.ber.

Development of Red Pepper Dryer -Simulation and Optimization- (고추 건조기(乾燥機)의 개발(開發)에 관한 연구(硏究) -시뮬레이션 및 최적화-)

  • Keum, D.H.;Choi, C.H.;Kim, S.Y.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.3
    • /
    • pp.248-262
    • /
    • 1991
  • Simulation model was developed to analyze drying process for tray type red pepper dryer and validated by experiments. This model could predict satisfactorily temperatures and moisture contents of red pepper and temperatures of drying air during drying. Optimize algorithm was developed to search control valiables (drying air temperature, air recycle ratio and air flow rate) of red pepper dryer based on a criterion of minimizing energy consumption under the constraint conditions that statisfied carotenoid retension of at least 210mg per 100g dry matter, the moisture content of bottom layer of 15% (d.b) and drying time of less than 35 hours. Step changes in drying air temperature and air recycle ratio were considered in the optimization. In single step in control variables, the difference of the moisture content between top layer and bottom layer was great and more fan power was required. As the drying trays were exchanged when the moisture content of bottom layer reached to 100% (d.b), fifty percent of energy was saved and the difference of moisture content was little. In double step changes in control variables, optimal conditions were found by changing the step when the moisture content of bottom layer reached to 100% (d.b) (about 19.8 hours from starting drying). Optimum air flow rate was $18.1cmm/m^2$. Optimum drying air temperature and air recycle ratio in the first step was $55.8^{\circ}C$ and 0.80, and in the second step $65.6^{\circ}C$ and 0.88, respectively. In triple step changes in control variables, the optimal conditions were found by changing the steps when the moisture content of bottom layer reached to 250% (d.b) and 150% (d.b). Optimal air temperatures were $66.2^{\circ}C$, $58.4^{\circ}C$ and $66.9^{\circ}C$, and optimal air recycle ratios were 0.778, 0.785, 0.862 at each step, respectively. Optimal air flow rate was $18.9cmm/m^2$. The best operating mode was triple step mode considering energy consumption, drying time, fan power, and quality of dried red pepper. When the triple step mode was used to dry the red pepper, the energy consumption was about 16.5%~57.2% less than that of the single step mode and the drying time was 6.6 hours shorter than that of the double step mode.

  • PDF

Performance Characteristics of Air Driven Ejector According to the Position Changes and the Shape of Driving Nozzle (공기구동 이젝터의 노즐 형상과 위치 변화에 따른 성능 특성)

  • Ji, Myoung-Kuk;Kim, Pil-Hwan;Park, Ki-Tae;Utomo, Tony;Chung, Han-Shik;Jeong, Hyo-Min
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.550-556
    • /
    • 2008
  • The aim of this research is to analyze the influence of motive pressure, driving nozzle position and nozzle throat ratio on the performance of ejector. The experiment was conducted in the variation of motive pressure of 0.196, 0.294, 0.392 and 0.490MPa respectively. The position of driving nozzle was varied in difference locations according to mixing tube diameter(0.5d, 1d, 2d, 3d, 4.15d, 5d and 6d). The experimental results show when the nozzle outlet is located at 3d, the flow characteristics change abruptly. It is shown that the suction flow rate and pressure lift ratio of ejector is influenced by the driving nozzle position. At nozzle position location of the Id of mixing tube diameter the performance of ejector gives the best performance.

Flow and Heat Transfer Characteristics in Ice Making Heat Exchanger Applied to Ice-Storage System (빙축열 시스템의 제빙용 열교환기내에서 유동 및 열전달 특성)

  • Back, Young-Ryoul;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.110-119
    • /
    • 1994
  • Three dimensional characteristics of fluid flow and heat transfer have been studied numerically around the latent heat storage vessel which was applied to the practical ice-storage system. The result obtained indicates that the value of frictional coefficient decreases with decrease of baffle width. For the baffle spacing. $S/H_D=9.375$, baffle height. $H/H_D=0.5$ and various pressure drop, average Nusselt numbers in heat transfer surface are much dependent on the width of side baffle and middle baffle. that is. Nu_m decreases with decrease of the width of middle baffle when the width of side baffle is 4.375, where as the optimum condition of side baffle for $Nu_m$ exists in the range of 3.5< $B_1/H_D$ <4.375 at the width of middle baffle, $B_2/H_D=6.875$.

  • PDF

Micro-Bubble Generating Properties on Gas/Liquid Flow Rate Ratio with the Sludge Flotation/Thickening Apparatus (슬러지 부상농축장치의 기·액 유량비에 따른 미세기포 발생 특성)

  • Lee, Chang-Han;Park, Jong-Won;Ahn, Kab-Hwan
    • Journal of Environmental Science International
    • /
    • v.23 no.1
    • /
    • pp.97-104
    • /
    • 2014
  • The sludge flotation/thickening apparatus equipped a micro-bubble generating pump was used to investigate micro-bubble generating properties on operational parameters. We evaluated micro-bubble generating properties as results to be operated the apparatus by operational parameters which are pump discharge pressure, air/water ratio(A/W ratio), air flow rate, and water flow rate. Micro-bubble generating efficiencies in pumps without recycling flow and with 50% of recycling flow was found to be very efficient on optimum A/W ratio from 1.06 to 3.62% and optimum A/W ratio from 1.05 to 4.06%, respectively. In condition of 3.6% of A/W ratio, we showed that the apparatus could be generated 36,000 ppm of micro-bubble concentration to be optimum treatment efficiency in sludge thickening process.

An Experimental Study on the Measurement of the Droplet-Air Relative Velocity in the Multi-hole Diesel Spray (다공 디젤분무의 액적-공기 상대속도 측정에 관한 실험적 연구)

  • Kweon, M.H.;Shin, S.H.;Lee, J.K.;Kang, S.J.;Rho, B.J.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.801-806
    • /
    • 2000
  • This experimental study is to investigate the intermittent spray characteristics of a multi-hole nozzle in a heavy-duty DI diesel engine. Multi 8 hole$(d_n=0.25mm)$, Multi 3 hole$(d_n=0.42)$ and Sing hole nozzle$(d_n=0.25mm)$ were used in this experiment. By using the 2-D PDPA(phase Doppler particle analyzer), the droplet diameter and the velocity of a diesel spray injected intermittently from the multi and the single-hole nozzle into a still ambient were measured. In order to calculate the mean values such as mean velocity, SMD, AMD etc. and to analyze the intermittent characteristics, the time-window of 0.15ms were applied. In the spray, the small droplet$(D<10{\mu}m)$ was regarded as an air flow, and the correlation between the fuel droplet$(10{\mu}m and the air (low was examined. The normalized axial droplet-air relative velocity of the 8 hole, the 3 hole and the single hole nozzle was evaluated as 0.081, 0.067, 0.06 and in case of the radial droplet-air relative velocity, the normalized. value is 0.014, 0.013 and 0.008 respectively.

  • PDF

A Numerical Study on the Flow Characteristics of Kitchen Hood System (주방용 후드시스템의 유동특성에 관한 수치적 연구)

  • Lim Kyung-Bin;Lee Kwang-Sub;Lee Chang-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.4
    • /
    • pp.359-369
    • /
    • 2006
  • This study aims deriving analysis the flow characteristic of kitchen hood system with using 3-D numerical analysis method and improving the system to expel pollutes more efficiently. This system is applied with $k-{\varepsilon}$ turbulent model and using incompressibility viscosity flow range and boundary condition which are related to Bossinesq approximation following density variation in control volume. To understand the flow characteristics of four models, this study only focuses on velocity field, temperature field, and concentration field varying with followings whether separation plate is set or not and the shapes of separation plates. The quantity of air, speed of exhaust fan and temperature and concentration of heating source are concerned as constant values.

Research on the Optimal Operating Condition of a Total Heat Exchanger in Solar Air-Conditioning System (태양열 이용 냉난방 공조시스템 중 전열교환기의 최적운전조건에 관한 연구)

  • Kim, K.H.;Choi, K.H.;Kum, J.S.;Kim, B.C.;Kim, D.G.
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.55-62
    • /
    • 1999
  • This study was performed to find out the influence of experimental factors on dehumidification performance and furthermore to suggest an optimal combination of factors of a total heat exchanger in a solar air conditioning system. The experimental apparatus was set up in a climate-controlled chamber where the temperature and humidity was maintained constant. In order to find out the contribution ratio of factors on dehumidification performance, the table of orthogonal arrays $L_8(2^7)$ was used. According to the results, the most influential factor on dehumidification performance was the concentration of LiCl(Lithium Chloride) solution. The next influential factors were the temperature of LiCl solution and the air flow rate. The packed layer height, packed material, and flow rate of LiCl solution had no influence on the dehumidification performance under these experimental conditions. Through the three level experiments of $L_{27}(3^{13})$, it was found that the optimal combination was $A_2B_0G_2$(concentration of solution 30 wt%, temperature of solution $15^{\circ}C$, air flow rate $253m^3/h$).

  • PDF

A Study on Coating Deviation Effect by Air Knife Characteristics in CGL (연속용융도금라인에서 에어나이프 특성이 도금편차에 미치는 영향)

  • Bae, Y.H.;Ahn, D.S.;Lee, S.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.3
    • /
    • pp.57-68
    • /
    • 1993
  • Air Wiping technique is widely used because of easy and efficient coating control in present CGL. Coaring weight is decided by nozzle header pressure, strip line speed and distance between strip and nozzle. Coating defects are results from unbalance of these factors and coating equipment calibration inaccuracy. Therefore, this study is mainly dealing with the cause of coating defects such as edge overcoating and coating deviation. The coptimum working condition is suggested by formulated coating model using collected working data. We developed two demension analysis program for air flow in nozzle and calculated dynamic pressure and air velocity with this program. The productivity and coating guality are improved by applying the result of this reserach.

  • PDF

Effects of Ventilation Systems on Interior Environment of the Growing-finishing Pig House in Korea (육성$\cdot$비육돈사 내에서 환기형태별 환경조사 연구)

  • Song J. I.;Yoo Y. H.;Jeong J. W.;Kim T. I.;Choi H. C.;Kang H. S.;Yang C. B.;Lee Y. Y.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • An experiment was conducted to establish comparison of ventilation efficiency in an enclosed and conventional growing-finishing pig house. The experimental pigs were in winter and summer. The main results of the experiment are as follows : Then the air from planar slot inlet the pig house flow out through the sidewall outlet operated by exhaust fan(Gl). The second structure has an air input through the circular duct inlet are plated side the juncture of the entering wall and the air into the pig house flow out through the chimney and pit outlet are operated by exhaust fan(G2). Through the air into relay fan the pig house flow out through the curtains in sidewall(G3). Similarly, air comes in through the circular duct inlet are placed the air into the pig house flow out through the curtains in sidewall (G4). Air flow rate on the floor level which is the low part of pen and the living area of pigs in the G2 and G4 system during winter was measured at 0.2 to 0.3 m/s at the 0.5 to 0.6 m/s at the maximum ventilation efficiency. As for the results of detrimental gas(ammonia) concentration ratio analysis, while G2 and G4 system sustained of summer 13.3 $\~$ 16.6 ppm, winter 14.0 $\~$ 14.6 ppm level, Gl and G3 system sustained of summer 14.6 $\~$ 20.3 ppm, winter 20.3 $\~$ 25.0 ppm, and the latter one is lower than that of the G1 and G3 system.

  • PDF