• Title/Summary/Keyword: 3D 재구성

Search Result 482, Processing Time 0.024 seconds

A Study on the Delaunay Triangulation Reconstruction using the Modified EVS (수정된 EVS를 이용한 Delaunay 삼각형 재구성에 관한 연구)

  • Kwon E.C.;Shin D.K.;Kim D.Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.225-231
    • /
    • 2000
  • The Delaunay triangulation. which is one of the surface rendering methods. have been evaluated as a good algorithm which can solve the geometrical connection problems and make high quality images. However this method also have the problem that is the 'non-solid' connection between slices. In this paper, we proposed a new method for the Delaunay triangulation for the surface rendering from 2D medical images in the PC environment. The proposed method was designed to eliminate 'non-solid' tetrahedra. which had no correspondence to the geometric closeness, and used elimination algorithm with modified External Voronoi Skeleton path. This method enabled us to eliminate 'non-solid' tetrahedra without affecting other regions. Thus we could effectively reconstruct the complex shaped objects which were compactly connected with tetrahedra.

  • PDF

Hardware Implementation of FPGA-based Real-Time Formatter for 3D Display (3D 디스플레이를 위한 FPGA-기반 실시간 포맷변환기의 하드웨어 구현)

  • Seo Young-Ho;Kim Dong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.5
    • /
    • pp.1031-1038
    • /
    • 2005
  • In this paper, we propose real-time 3D image converting architecture by a unit of pixel for 2D/3D compatible PC and LCD of cellular phone with parallax burier, and implement a system for overall display operation after designing a circuit based on FPGA. After digitizing anolog image signal from PC, we recompose it to 3D image signal according to input image type. Since the architecture which rearranges 2D image to 3D depends on parallax burier, we use interleaving method which mixes pixels by a unit of R, G, and B cell. The propose architecture is designed into a circuit based on FPGA with high-speed memory access technique and use 4 SDRAMs for high performance data storing and processing. The implemented system consists of A/D converting system, FPGA system to formatting 2D signal to 3D, and LCD panel with parallax barrier, for 3D display.

Reconstructing 3D Solid Shape from a Single Perspective Drawing (투시도로부터 3차원 입체 형상 재구성)

  • 조유정;김광수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.725-730
    • /
    • 1994
  • 2차원 도면으로부터 3차원 입체형상으로의 재구성은 CAD/CAM에서 많이 연구되어 온 분야이다. 이 논문에서는 건축에서 쓰이는 3점 소실법을 이용하여, 자유곡선을 포함하는 하나의 투시도로부터 3차원 정보를 추출하고, 그 위상학적 관계와 loop detection 알고리즘을 통해서 면정보를 추출한다. 추출된 면정보를 입체 구조로 변환하고 연속성을 부여한다. 그리고 쉬운 사용자 인터페이스를 제공하여 사용자의 의도에 맞는 적절한 입체영상을 만들어 내고자 하였다.

  • PDF

A Reconfigurable Antenna for Mobile Handset Using RF Switch (RF 스위치를 이용한 이동통신 단말기용 재구성 안테나)

  • Hwang, Sun-Gook;Yoon, Cheol;Park, Chan-Sub;Park, Hyo-Dal
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.13 no.5
    • /
    • pp.21-26
    • /
    • 2014
  • This paper proposes a frequency reconfigurable antenna which operates at not only LTE but also other currently serviced bands. The high band(1,710-2,170 MHz) performance was satisfied through PIFA structure, and the low band performance through the additional RF Switch by changing the state between SW1 and SW2. When the RF switch is SW1 state, the operation bandwidth is 782-907 MHz (GSM), and 738-861 MHz (LTE) at OFF state. The proposed antenna has a omni-directional radiation pattern and measured peak gains were 0.04-4.68 dBi at the SW1 state and 0.92-1.53 dBi at the SW2 state, respectively. Judging from the results, proposed reconfigurable antenna is expected to be applied to LTE-Advanced mobile terminals since the antenna shows an outstanding performance.

SVD Pseudo-inverse and Application to Image Reconstruction from Projections (SVD Pseudo-inverse를 이용한 영상 재구성)

  • 심영석;김성필
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.3
    • /
    • pp.20-25
    • /
    • 1980
  • A singular value decomposition (SVD) pseudo-inversion method has been applied to the image reconstruction from projections. This approach is relatively unknown and differs from conventionally used reconstructioll methods such as the Foxier convolution and iterative techniques. In this paper, two SVD pseudo-inversion methods have been discussed for the search of optimum reconstruction and restoration, one using truncated inverse filtering, the other scalar Wiener filtering. These methods partly overcome the ill-conditioned nature of restoration problems by trading off between noise and signal quality. To test the SVD pseudo-inversion method, simulations were performed from projection data obtained from a phantom using truncated inversefiltering. The results are presented together with some limitations particular to the applications of the method to the general class of 3-D image reconstruction and restoration.

  • PDF

Usefulness of Region Cut Subtraction in Fusion & MIP 3D Reconstruction Image (Fusion & Maximum Intensity Projection 3D 재구성 영상에서 Region Cut Subtraction의 유용성)

  • Moon, A-Reum;Chi, Yong-Gi;Choi, Sung-Wook;Lee, Hyuk;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • Purpose: PET/CT combines functional and morphologic data and increases diagnostic accuracy in a variety of malignancies. Especially reconstructed Fusion PET/CT images or MIP (Maximum Intensity Projection) images from a 2-dimensional image to a 3-dimensional one are useful in visualization of the lesion. But in Fusion & MIP 3D reconstruction image, due to hot uptake by urine or urostomy bag, lesion is overlapped so it is difficult that we can distinguish the lesion with the naked eye. This research tries to improve a distinction by removing parts of hot uptake. Materials and Methods: This research has been conducted the object of patients who have went to our hospital from September 2008 to March 2009 and have a lot of urine of remaining volume as disease of uterus, bladder, rectum in the result of PET/CT examination. We used GE Company's Advantage Workstation AW4.3 05 Version Volume Viewer program. As an analysis method, set up ROI in region of removal in axial volume image, select Cut Outside and apply same method in coronal volume image. Next, adjust minimum value in Threshold of 3D Tools, select subtraction in Advanced Processing. It makes Fusion & MIP images and compares them with the image no using Region Cut Definition. Results: In Fusion & MIP 3D reconstruction image, it makes Fusion & MIP images and compares them by using Advantage Workstation AW4.3 05's Region Cut Subtraction, parts of hot uptake according to patient's urine can be removed. Distinction of lesion was clearly reconstructed in image using Region Cut Definition. Conclusion: After examining the patients showing hot uptake on account of volume of urine intake in bladder, in process of reconstruction image, if parts of hot uptake would be removed, it could contribute to offering much better diagnostic information than image subtraction of conventional method. Especially in case of disease of uterus, bladder and rectum, it will be helpful for qualitative improvement of image.

  • PDF

Dynamic Reconfiguration of Qis Visualization Spreadsheet (동적 재구성이 가능한 Qis Visualization Spreadsheet)

  • Jee, Sung-Hyun;Kwon, Young-Hee;Youn, Kil-Joong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.42 no.5
    • /
    • pp.79-86
    • /
    • 2005
  • The Qis visualizational spreadsheet environment is shown to be extremely effective in supporting the organized visualization of multi-dimensional data sets. The Qis consists of the reconfigurative 2D arrangement of spreadsheet elements at run time and each spreadsheet element has a novel framestack. As the feature, it supports 3D data structure of each element on the Qis. It enables the visualization spreadsheet to effectively manage, rapidly organize, and compactly encapsulate multi-dimensional data sets for visualization. Using several experiments with scientific users, the Qis has been demonstrated to be a highly interactive visual browsing tool for the analysis of multidimensional data, displaying 2D and 3D graphics, and rendering in each frame of the spreadsheet.

Extraction of Key Frames for 3D Reconstruction (3차원 재구성을 위한 키 프레임 추출)

  • Choi, Jongho;Yoo, Jisang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2016.06a
    • /
    • pp.5-8
    • /
    • 2016
  • 키 프레임 추출 기법은 2차원 비오 영상을 3차원으로 재구성하기 위해 꼭 필요한 프레임을 선택하는 방법이다. 본 논문에서는 비디오에서 빠르게 프레임을 검사하며 최적의 키 프레임을 선택하는 기법을 제안한다. 제안하는 기법은 3차원 재구성을 위한 전처리 과정에 초점을 둔 것으로 프레임 간 대응점 비율 검사를 통해 프레임의 도약 강도를 결정하고 기하 모델 추정이 원활한 프레임을 선택한다. 이로부터 3차원 복원 후처리 과정을 통해 최종적인 3차원 점군(point cloud) 데이터를 획득한다. 실험을 통해 다른 기법과 성능을 비교했을 때, 제안하는 기법이 복원 소요 시간도 적게 들고 보다 밀집된 3차원 데이터를 얻을 수 있었다.

  • PDF

A Reconfigurable Antenna for Quad-Band Mobile Handset Application (4중 대역을 포함하는 휴대폰용 재구성 안테나)

  • Park, Young-Keun;Sung, Young-Je
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.5
    • /
    • pp.570-582
    • /
    • 2012
  • In the communication, a reconfigurable antenna using two PIN diodes is presented for quad-band(GSM900/GSM1800/GSM1900/UMTS) mobile handset applications. The proposed antenna has a size $45{\times}11{\times}6mm^3$. By independently adjusting the on/off states of two PIN diodes located on the radiating element, the proposed structure can be operated in the PIFA and loop mode, respectively. The PIN diodes are replaced by conducting tape in order to verify the concept. In regards to the fabricated reconfigurable antenna, when operating in the PIFA mode, the measured results show that the 7 dB bandwidth is 8.62 %. which covers the GSM900(880~960 MHz) band. When operating in the loop mode, the measured results show that the 7 dB bandwidth is 26.36 %, which covers the GSM1800(1,710~1,880 MHz), GSM1900(1,850~1,990 MHz), and UMTS(1,920~2,170 MHz) bands, respectively.

Reconstruction of Head Surface based on Cross Sectional Contours (단면 윤곽선을 기반으로 한 두부표변의 재구성)

  • 한영환;성현경;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.365-373
    • /
    • 1997
  • In this paper, a new method of the 3D(dimensional) image reconstruction is proposed to build up the 3D image from 2D images using digital image processing techniques and computer graphics. First, the new feature extraction algorithm that doesn't need various input parameters and is not affected by threshold is adopted This new algorithm extracts feature points by eliminating some undesirable points on the ground of the connectivity. Second, as the cast function to reconstruct surfaces using extracted feature points, the minimum distance measure between two plane images has been adopted According to this measure, the surface formation algorithm doesn't need complex calculation and takes the form of triangle or trapezoid To investigate usefulness, this approach has been applied to a head CT image and compared with other methods. Experimental comparisons show that the suggested algorithm yields better performance on feature extraction than others. In contrast with the other methods, the complex calculation for surface formation in the proposed algorithm is not necessary.

  • PDF