• Title/Summary/Keyword: 3D 발 스캔

Search Result 10, Processing Time 0.02 seconds

A Study on Foot Shape by 3D Data of Female High School Students (3차원 데이터에 의한 여고생의 발 형태에 관한 연구)

  • Lee, Jeong-Eun;Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.4
    • /
    • pp.572-583
    • /
    • 2014
  • This study analyzes the foot shape of female high school students using 3D foot scan data based on a comparison with adult women (20s'-30s'). Data were collected from the foot anthropometry of 199 female high school students in Gwangju and Jeollanam-do. The right foot was measured indirectly by 3D laser scanner. There are 16 items in the foot anthropometric measurements. The $6^{th}$ Size Korea (measured by 3D scan data) is used for women's foot data. The results of the 3D measurements data investigation show that the foot length and foot width became longer and wider as the age increased. It is classified by three types after analyzing foot shape. Type 1 (28.1%) represented the shortest foot length, the narrowest foot width as well as the thick foot and long ankle shape. Type 2 (4.3%) represented the wide foot width such as the wide lateral ball width and semi-thickness shape. Type 3 (67.7%) referred to the widest foot width, flat foot and short ankle shape.

Analysis of Foot Shape and Size System of Male High School Students Using 3D Scan Data (3D 스캔 데이터를 활용한 남자 고등학생의 발 형태 및 치수체계 분석)

  • Shin, Yu Jin;Park, Soonjee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.1
    • /
    • pp.53-67
    • /
    • 2020
  • The purpose of this study is to analyze the foot shape and size specification of male high school students. 3D modeling programs such as 'Artec Studio', 'CATIA', and 'Auto CAD' measured the 3D scan data of 361 male high school students provided by KATS. Through principal factor analysis, 10 factors were extracted, including foot length, medial-lateral ratio, and foot length ratio. As the result of the cluster and ANOVA with post-hoc test (Duncan method), the differences among types were clarified. Type 1 (24.7%) represented outward medial-lateral ratio (M-L ratio) with the lowest instep, ankle and little deformed first toe. Type 2 (41.8%) was characterized by the shortest, even M-L ratio, thin ankle and heel, the highest instep and ankle. Type 3 (33.5%) showed the longest, inward M-L ratio, thick ankle and heel, and deformed first toe. As the cross-tabulation of foot length and ball circumference, 17.2 percent was not covered by KS standard; in addition, the foot length was longer than the KS standard. The correlation analysis of key dimensions showed that foot length and ball circumference were highly correlated with other items; therefore, regression equations were derived to estimate other foot measurements using these two items as independent variables.

Individual customized insole model (개인 맞춤형 자동 변형 인솔 모델)

  • Song, Eungyeol;Kim, Kyoungtae;Kim, Sang-hoon;Lee, Sangyoun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.4
    • /
    • pp.323-329
    • /
    • 2016
  • This paper describes an insole FFO(Functional Foot Orthosis) model for comfortable walking by considering weight distribution. There are many ways to make an insole FFO model such as using 3D computer graphics, or plaster manually. Thus, we proposed a standardized way to make an insole model, specifically called, robust and automatically personalized deformable insole model. Our proposed method showed 0.8cm average error compared between our proposed auto-deformable insole model and the other insole model manually deformed by experts. Therefore, our proposed method can be an efficient way to make a customized insole model with small error compared to the manually customized insole model.

A Study of Elementary School Students' Feet Growth by 3D Scan Data (3차원 스캔 데이터에 의한 초등학생의 발 성장에 관한 연구)

  • Lee, Jeong-Eun;Do, Wol-Hee
    • Fashion & Textile Research Journal
    • /
    • v.16 no.6
    • /
    • pp.935-944
    • /
    • 2014
  • This study was about to investigate the characteristics of elementary school students' feet growth, comparing and analyzed the measured values and the index values of 3D scan data. As the results from analyzing the measured values, the all measurement items excluding 'Toe 5 angle' showed some significant differences among the age classes, knowing that the elementary school students' feet were continually grown. Although, the items of length, thickness, width, height and circumference indicate some rapid growth of feet at 11 years old, but it appears slowing growth of 'Foot width' after the age of 11 years old. The angle item didn't show any sequential differences according to ages. As the results from analyzing the index values, the children in higher grades have longer 'Toe 5', thicker ankles, wider and thicker the superior part of feet than the children in lower grades. For the superior and the middle part of feet were lowly raised, their Arch height was low and thick. The inferior part of feet showed narrow width and higher height. Giving that the Medial ball width was wide and the Toe 1 angle is high for the children in higher grades, it is expected that the Metatarsophalangeal I might be more projected than that of children in lower grades. Likewise, knowing that the male students' feet shape was bigger than female students' feet from the result that the male students' index values were higher.

Last Design for Men's Shoes using 3D Foot Scanner and 3D Printer (3D 발 스캐너와 3D 프린터를 이용한 남성화 라스트 설계)

  • Oh, Seol-Young;Suh, Dong-Ae;Kim, Hyung-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.186-199
    • /
    • 2016
  • The shoe last which is the framework for the shoemaking is intensively combined with the 3D data and technologies. International shoe companies have already commercialized 3D printing technology in producing the shoe, but domestic shoe companies are still in their early stages. This study used the 3D scanning, 3D modeling and 3D printing of the high-technology to make the shoe last. This 3D producing processes should be helpful in building competitiveness in domestic shoe industry. The 3D foot scanning data of men in 30s(n=200) were collected in SizeKorea(2010). The basic statistics, factor and cluster analysis were performed. They were categorized in 3 groups by 3D foot measurement data, and the standard models were selected in each group. The cross sections in XY, YZ and XZ planes sliced from 3D scan data of the standard model were used in the sketches of the 3D shoe last modeling. The 3D shoe last was modeled by Solidworks CAD and printed by MakerBot Replicator2; a desktop 3D printer. This research showed the potential for utilization of 3D printing technology in the domestic shoe industry. The 3D producing process; 3D scanning, 3D modeling and 3D printing is expected to utilized widely in the fashion industry within the nearest future.

Classification of foot shapes of young and middle-aged/elderly men (청년층과 중노년층 남성의 발 형태 분류)

  • Lim, Ho Sun
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.5
    • /
    • pp.894-905
    • /
    • 2015
  • The present study analyzed data from the 3D measurement of the feet of men aged over 20 years residing in the capital region as part of the 6th Anthropometry of Size Korea. To analyze the characteristics of the foot shapes of young men aged 20~39 years and middle-aged/elderly men aged 40~69 years by age and by type, a cluster analysis was conducted using the factors derived through the factor analysis as independent variables. The results of the study that analyzed the characteristics of foot shapes by type according to differences in age were as follows. First, through the analysis of the characteristics of the foot shapes of young men by type, five factors were extracted, and the foot shapes were classified into three types: Type 1 (short and flat), Type 2 (thick), and Type 3 (long and wide). Second, through the analysis of the characteristics of the foot shapes of middle-aged/elderly men by type, six factors were extracted, and the foot shapes were classified into four types: Type 1 (short and regular), Type 2 (flat), Type 3 (thick), and Type 4 (long and regular). The results of the present study are expected to serve as basic data for the design of shoes by age and foot type.

Usefulness of Three-phasic Bone Scan in Young Male Patients Suspected of Post-traumatic Reflex Sympathetic Dystrophy Syndrome (외상후 교감신경 이영양증이 의심되는 젊은 남자 환자들에서 삼상 골스캔의 유용성)

  • Lee, Won-Woo;Kim, Tae-Uk;Kim, Tae-Hoon;Jung, Cheoul-Yun;Moon, Jin-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.52-60
    • /
    • 2001
  • Purpose: In young male patients who suffered several kinds of trauma with subsequent suspicious reflex sympathetic dystrophy syndrome, we performed three-phasic bone scan in order to investigate its usefulness. Materials and Methods: Patients with narrow range of age (21-25. mean $22.8{\pm}1.3$, all male) were included with suspicious reflex sympathetic dystrophy syndrome of 12 feet and 5 hands. Only one was bilateral feet case and 16 were ipsilateral (Rt:13, Lt:3). The etiologic traumas were 4 fractures, 4 sprains, 3 blunt trauma, 2 cellulitis, 1 tendon tear, 1 crush injury, 1 overexercise, and 1 unknown. Radiologically 3 showed osteoporotic changes. Three-phasic bone scans were performed $21.2{\pm}7.3wks$ after trauma. Results: According to symptom complex, confirmatory reflex sympathetic dystrophy syndrome 4 cases and suspicious 13 were analyzed. All confirmatory cases (100%) showed increased uptake at delay phase with periarticular accentuation. Of confirmatory 4 cases, 2 showed increased uptake in all three phases (perfusion: P, blood pool: B, and delay: D), and other 2 revealed decreased P but, both increased B and D. Of suspicious 13 cases, 9(69.2%) had increased D (4 periarticular and 5 focal), 2 decreased D, and 2 symmetric D. In 12 foot cases, so-called weight hearing patterns - increased contralateral sole at P and B - were revealed in 7(58.3%). Conclusion: Diffuse periarticular increased uptake at delay phase of three-phasic bone scan was a compatible finding to reflex sympathetic dystrophy syndrome in young male patients whose symptom complex strongly designated post traumatic reflex sympathetic dystrophy syndrome.

  • PDF

Classification of Elderly Men's Foot Side Type from 3D Scan Data (3차원 스캔 데이터에 의한 노년 남성의 발 측면유형 분류)

  • Kim, Nam-Soon;Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.4
    • /
    • pp.427-439
    • /
    • 2014
  • This study identifies the foot side shapes of elderly men by classifying foot types according to 3D foot shapes and analyzing individual characteristics. The subjects were 284 elderly men over 60 years of age who lived in Gwangju and did not have foot related diseases. They were measured with a scanner (Nexcan$^{(R)}$ of K&I Technology) to obtain three dimensional feet shapes. Anthropometric measuring items consisted of 28 items estimated on the right foot of each subject. 3D scan data were analyzed by various statistical methods such as factor analysis, ANOVA and cluster analysis using the statistical program SPSS 19.0. A total of 7 factors were extracted through a factor analysis and these factors represent 77.56% of total variance. The 8 factors were: inside height and side gradient, ankle thickness, size from foot center to ankle, lateral malleolus height, forefoot height, instep and heel height and gradient. A total of 3 clusters (as foot type) were categorized using 7 factor scores by cluster analysis. Type 1 was classified as high forefoot and low midfoot compared to the length. Type 2 was classified as low forefoot and high midfoot, and type 3 was classified as low forefoot and low midfoot.

Producing the insoles for flat feet of senior men using 3D systems based on 3D scanning, 3D modeling, and 3D printing (3D 스캐닝, 3D 모델링, 3D 프린팅 기반의 3D 시스템에 의한 시니어 평발용 인솔 제작)

  • Oh, Seol Young;Suh, Dongae
    • The Research Journal of the Costume Culture
    • /
    • v.25 no.3
    • /
    • pp.270-284
    • /
    • 2017
  • This study aimed to create 3D-printed insoles for flat-footed senior men using 3D systems. 3D systems are product-manufacturing systems that use 3-dimensional technologies like 3D scanning, 3D modeling, and 3D printing. This study used a 3D scanner (NexScan2), 3D CAD programs including Rapidform, AutoCAD, SolidWorks, Nauta+ compiling program, and a 3D printer. In order to create insoles for flat-footed senior men, we analyzed horizontal sections of 3D foot scans We selected 20 flat-footed and 20 normal-footed subjects. To make the 3D insole models, we sliced nine lines on the surface of the subjects' 3D foot scans, and plotted 144 points on the lines. We calculated the average of these 3D coordinates, then located this average within the 3D space of the AutoCAD program and created 3D sole models using the loft surface tools of the SolidWorks program. The sole models for flat feet differed from those of normal feet in the depth of the arch at the inner sideline and the big toe line. We placed the normal-footed sole model on a flat-footed sole model, and the combination of the two models resulted in the 3D insole for flat feet. We printed the 3D modeled insole using a 3D printer. The 3D printing material was an acrylic resin similar to rubber. This made the insole model flexible and wearable. This study utilized 3D systems to create 3D insoles for flat-footed seniors and this process can be applied to manufacture other items in the fashion industry as well.

The treatment of an edentulous patient with DENTCA$^{TM}$ CAD/CAM Denture (CAD/CAM Denture를 이용한 완전 무치악 환자 수복 증례)

  • Park, Joon-Ho;Cho, In-Ho;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.19-25
    • /
    • 2015
  • Nowadays, CAD/CAM is broadly used in dentistry for inlays, crowns, implant abutments and its spectrum is expanding to complete dentures. Utilizing CAD/CAM to fabricate complete dentures is expected to decrease chair time and the number of visits, thus decreasing total fabrication time, expenses and errors caused during fabrication processes. One of the systems using CAD/CAM, DENTCA$^{TM}$ CAD/CAM denture (DENTCA Inc. Los Angeles, USA) scans edentulous impressions, designs dentures digitally, fabricates try-in dentures by 3D printing and converts them into final dentures. Patients can wear final dentures after only 2 - 3 visits with satisfying adaptation. This case report introduces a 71-year-old male patient who visited to consult remaking of existing old dentures. Residual teeth with bad prognosis and root remnants were extracted and the patient used reformed existing mandibular denture for 2 months. And then DENTCA system started. One-step border molding was done using conventional tray of adequate size provided by DENTCA system and wash impression was taken. Gothic arch tracing was completed based on the vertical dimension of existing dentures. Both maxillary and mandibular trays were placed to the resultant centric relation and bite registration was taken. Then DENTCA scanned the bite registration, arranged the teeth, completed the festooning and fabricated the try-in dentures by 3D printing. The try-in dentures were positioned, occlusal plane and occlusal relations were evaluated. The try-in dentures were converted to final dentures. To create bilateral balanced occlusion, occlusal adjustment was done after clinical remounting using facebow transfer. The result was satisfactory and it was confirmed by patient and operator.