• Title/Summary/Keyword: 3D/0D coupling

Search Result 379, Processing Time 0.028 seconds

Piezoelectric and Dielectric Properties of PMN-PNN-PZT with the Sintering Temperature (소결온도에 따른 PMN-PNN-PZT 세라믹스의 압전 및 유전 특성)

  • Lee, Yu-Hyong;Yoo, Ju-Hyun;Lee, Sang-Ho;Yoon, Hyun-Sang;Ryu, Sung-Lim
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.290-291
    • /
    • 2007
  • In this study, in order to develop low temperature sintering ceramics for multilayer piezoelectric actuator, sensers, transducers, PMN-PNN-PZT ceramics were manufacrtured with the sintering temperature, and their piezoelectric and dielectric properties were investigated. At the composition ceramics sintered at $900^{\circ}C$, desity, dielectric constant$({\varepsilon}_r)$, electromechanical coupling factor(kp), piezoelectric constant$(d_{33})$ and mechanical quality factor(Qm) showed the optimal value of $7.86g/cm^3$, 1417, 0.634, 410pC/N and 1138, respectively.

  • PDF

Piezoelectric and Dielectric Characteristics of Lead Free [Li0.04(NayK1-y)0.96](Nb0.86Ta0.1Sb0.04)O3 Ceramics with the Variations of Na/K Ratio (Na/K 비 변화에 따른 무연 [Li0.04(NayK1-y)0.96](Nb0.86Ta0.1Sb0.04)O3 세라믹스의 압전 및 유전특성)

  • Lee, Kab-Soo;Yoo, Ju-Hyun;Hong, Jae-Il;Lee, Seok-Tae;Kim, Yong-Woon;Jeong, Hoy-Seung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.1
    • /
    • pp.25-30
    • /
    • 2007
  • In this paper, lead-free [$Li_{0.04}(Na_{y}K_{1-y})_{0.96}](Nb_{0.86}Ta_{0.1}Sb_{0.04})O_{3}$ (y=0.4 - 0.58) ceramics were manufactured using conventional miked oxide method for acoustic emission(AE) sensor application and their dielectric and piezoelectric properties were investigated with the variations of Na/K ratio. The samples in the composition Na/K=54/46 exhibited excellent electrical properties of $d_{33}=300$ PC/N and kp=0.49. Taking into consideration above piezoelectric properties, it can be concluded that the [$Li_{0.04}(Na_{y}K_{1-y})_{0.96}](Nb_{0.86}Ta_{0.1}Sb_{0.04})O_{3}$ system ceramics are the promising lead-free materials capable of substituting PZT system ceramics.

Effects of High Energy Ball Milling on the Piezoelectric Properties of Lead-free (K0.44Na0.52)(Nb0.86Ta0.10)-0.04LiSbO3 Ceramics (고에너지 볼 밀링을 이용한 (K0.44Na0.52)(Nb0.86Ta0.10)-0.04LiSbO3 무연 압전 세라믹스의 특성)

  • Kim, Young-Hyeok;Heo, Dae-Young;Tai, Weon-Pil;Lee, Jae-Shin
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.6
    • /
    • pp.363-367
    • /
    • 2008
  • Lead-free $(K_{0.44}Na_{0.52})(Nb_{0.86}Ta_{0.10})-0.04LiSbO_3$ piezoelectric ceramics have been synthesized by conventional sintering process and then investigated on the sintering and piezoelectric properties by high energy ball milling (HEBM) treatment. The powders milled for different time are characterized by XRD, FE-SEM. The powders are pressed into a pellet and sintered. It is found that the piezoelectric properties of sintered specimens are strongly dependent on the milling time. The piezoelectric properties are enhanced by high energy ball milling treatment. The planer electromechanical coupling factor ($k_p$) and piezoelectric constant ($d_{33}$) of a specimen sintered at $1050^{\circ}C$ are 0.44 and 267 pC/N, respectively.

Dielectric and Piezoelectric Characteristics of PMN-PNN-PZT Ceramics with the methods of $MnO_2$ additon ($MnO_2$ 첨가방법에 따른 PMN-PNN-PZT 세라믹스의 유전 및 압전특성)

  • Kim, Do-Hyung;Kim, Kook-Jin;Yoo, Ju-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.255-256
    • /
    • 2007
  • In the study, in order to develop low temperature sintering ceramics for multilayer piezoelectric actuator, PMN-PNN-PZT ceramics were fabricated using $Na_2CO_3,\;Li_2CO_3$ as sintering aids and their dielectric and piezoelectric properties were investigated according to the variations of $MnO_2$ as additives and sintering aids. At the sintering temperature of $900^{\circ}C$ and 0.1wt% $MnO_2$ as sintering aids, density, electromechanical coupling factor$(k_p)$, mechanical quality factor$(Q_m)$, piezoelectric constant$(d_{33})$, and dielectric constant $({\varepsilon}_r)$ showed the optimum value of $7.87[g/cm^3]$, 0.61, 1131, 1127 and 376, respectively, for multilayer piezoelectric actuator application.

  • PDF

Crossover from weak anti-localization to weak localization in inkjet-printed Ti3C2Tx MXene thin-film

  • Jin, Mi-Jin;Um, Doo-Seung;Ogbeide, Osarenkhoe;Kim, Chang-Il;Yoo, Jung-Woo;Robinson, J. W. A.
    • Advances in nano research
    • /
    • v.13 no.3
    • /
    • pp.259-267
    • /
    • 2022
  • Two-dimensional (2D) transition metal carbides/nitrides or "MXenes" belong to a diverse-class of layered compounds, which offer composition- and electric-field-tunable electrical and physical properties. Although the majority of the MXenes, including Ti3C2Tx, are metallic, they typically show semiconductor-like behaviour in their percolated thin-film structure; this is also the most common structure used for fundamental studies and prototype device development of MXene. Magnetoconductance studies of thin-film MXenes are central to understanding their electronic transport properties and charge carrier dynamics, and also to evaluate their potential for spin-tronics and magnetoelectronics. Since MXenes are produced through solution processing, it is desirable to develop deposition strategies such as inkjet-printing to enable scale-up production with intricate structures/networks. Here, we systematically investigate the extrinsic negative magnetoconductance of inkjetprinted Ti3C2Tx MXene thin-films and report a crossover from weak anti-localization (WAL) to weak localization (WL) near 2.5K. The crossover from WAL to WL is consistent with strong, extrinsic, spin-orbit coupling, a key property for active control of spin currents in spin-orbitronic devices. From WAL/WL magnetoconductance analysis, we estimate that the printed MXene thin-film has a spin orbit coupling field of up to 0.84 T at 1.9 K. Our results and analyses offer a deeper understanding into microscopic charge carrier transport in Ti3C2Tx, revealing promising properties for printed, flexible, electronic and spinorbitronic device applications.

Piezoelectric Properties of Lead-Free (K0.5Na0.5)NbO3 Ceramics Added with ZnO and MnO2 (ZnO와 MnO2를 동시에 첨가한 (K0.5Na0.5)NbO3 세라믹스의 압전 특성에 대한 연구)

  • Hong, Young Hwan;Park, Young-Seok;Jeong, Gwang-Hwi;Cho, Sung Youl;Lee, Jae-Shin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.4
    • /
    • pp.210-214
    • /
    • 2016
  • We investigated the sintering behavior and piezoelectric properties of lead-free $(K_{0.5}Na_{0.5})NbO_3$ ceramics co-doped with excess 0.01 mol ZnO and x mol $MnO_2$, where x was varied from 0 to 0.03. Excess $MnO_2$ addition was found to retard the grain growth and densification during sintering. However, 0.005 mol $MnO_2$ addition improved the piezoelectric properties of 0.01 mol ZnO added $(K_{0.5}Na_{0.5})NbO_3$ ceramics. The planar mode piezoelectric coupling coefficient, electromechanical quality factor, and piezoelectric constant $d_{33}$ of 0.01 mol ZnO and 0.005 mol $MnO_2$ added specimen were 0.40, 304, and 214 pC/N, respectively.

Broadband MIMO Antenna Using the Metal Cover Radiator (메탈 커버를 방사소자로 이용한 광대역 MIMO 안테나)

  • Kim, ByungChul;Park, Minkil;Son, Taeho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.9
    • /
    • pp.769-776
    • /
    • 2015
  • In this paper, a broadband MIMO antenna using the metal cover that is one of the antenna radiators is designed and implemented on the PCB. The proposed antenna consists of a monopole and an IFA fed by the coupling structure and a metal cover radiator. Therefore, a monopole and an IFA with a metal cover radiator operate simultaneously through a hybrid form of operation. The antenna satisfies VSWR 3:1 at the bands of LTE class 13, class 14, CDMA, GSM900, DCS, PCS, WCDMA, LTE class 40 and WiFi. The maximum ECC of diagonally fed MIMO antenna is 0.186. The measured average gain and efficiency were -5.14~-1.28 dBi and 30.87~74.48 % over the desire bands, respectively.

Design of a 900 MHz RFID Compact LTCC Package Reader Antenna Using Faraday Cage (Faraday Cage를 이용한 900 MHz RFID 소형 LTCC 패키지 리더 안테나의 설계)

  • Kim, Ho-Yong;Mun, Byung-In;Lim, Hyung-Jun;Lee, Hong-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.5 s.120
    • /
    • pp.563-568
    • /
    • 2007
  • In this paper, the proposed package antenna, which is meander line structure with short pin, is miniaturized to realize RF-SoP at 900 MHz RFID band. The RFID BGA(Ball Grid Array) chip is put in a cavity of LTCC Layers. The coupling and cross talk, which are happen between BGA chip and proposed package antenna, are reduced by faraday cage, which consists of ground and via fences, is realized to enhance the isolation between BGA chip and antenna. The proposed antenna structure is focused on the package level antenna realization at low frequency band. The novel proposed package antenna size is $13mm{\times}9mm{\times}3.51mm$. The measured resonance frequency is 0.893 GHz. The impedance bandwidth is 9 MHz. The maximum gain of radiation pattern is -2.36 dBi.

Optimum Compositions for Piezoelectric Properties of Pb-free (Bi0.5Na0.5)(1-x)BaxTiO3 Ceramics (비납계 (Bi0.5Na0.5)(1-x)BaxTiO3 압전 세라믹 재료의 최적 조성)

  • Sung, Yeon-Soo;Yeo, Hong-Goo;Cho, Jong-Ho;Song, Tae-Kwon;Jeong, Soon-Jong;Song, Jae-Sung;Kim, Myong-Ho
    • Korean Journal of Materials Research
    • /
    • v.17 no.2
    • /
    • pp.68-72
    • /
    • 2007
  • Optimum compositions for piezoelectric properties of $(Bi_{0.5}Na_{0.5})_{(1-x)}Ba_xTiO_3$ ceramics were investigated in the range of $x=0{\sim}0.1$ covering rhombohedral to tetragonal phase regions. No impurity phases other than a perovskite phase were found and the grain size decreased with increasing x. A two-phase coexisting morphotropic phase area rather than boundary dividing rhombohedral and tetragonal phase regions appeared to exist at $x=0.05{\sim}0.08$. As for piezoelectric properties within morphotropic phase compositions, the piezoelectric constant ($d_{33}$) and the electromechanical coupling factor ($K_p$) showed peak values at x=0.065, 192 pC/N and 34%, respectively, indicating x=0.065 as an optimum composition for piezoelectric $(Bi_{0.5}Na_{0.5})_{(1-x)}Ba_xTiO_3$ ceramics.

Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture (손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스)

  • Jang, Ik-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.